Data Acquisition and Control Systems Laboratory

The Data Acquisition and Control Systems (DACS) Laboratory is a facility at Stennis Space Center that provides an off test-stand capability to develop data-acquisition and control systems for rocket-engine test stands. It is also used to train new employees in state-of-the-art systems, and provides a controlled environment for troubleshooting existing systems, as well as the ability to evaluate the application of new technologies and process improvements. With the SSC propulsion testing schedules, without the DACS Laboratory, it would have been necessary to perform most of the development work on actual test systems, thereby subjecting both the rocket-engine testing and development programs to substantial interference in the form of delays, restrictions on modifications of equipment, and potentially compromising software configuration control. The DACS Laboratory contains a versatile assortment of computer hardware and software, digital and analog electronic control and data-acquisition equipment, and standard electronic bench test equipment and tools. Recently completed Control System development and software verification projects include support to the joint NASA/Air Force Integrated Powerhead Demonstration (IPD) LOX & LH2 PreBurner and Turbopump ground testing programs. In other recent activities, the DACS Laboratory equipment and expertise have supported the off-stand operation of high-pressure control valves to correct valve leak problems prior to installation on the test stand. Future plans include expanding the Laboratory's capabilities to provide cryogenic control valve characterization prior to installation, thereby reducing test stand activation time.

Holland, Randy↗

Vehicle-Level Oxygen/Methane Propulsion System Hotfire Testing at Thermal Vacuum Conditions

A prototype integrated liquid oxygen/liquid methane propulsion system was hot-fire tested at a variety of simulated altitude and thermal conditions in the NASA Glenn Research Center Plum Brook Station In-Space Propulsion Thermal Vacuum Chamber (formerly B2). This test campaign served two purposes: 1) Characterize the performance of the Plum Brook facility in vacuum accumulator mode and 2) Collect the unique data set of an integrated LOX/Methane propulsion system operating in high altitude and thermal vacuum environments (a first). Data from this propulsion system prototype could inform the design of future spacecraft in-space propulsion systems, including landers. The test vehicle for this campaign was the Integrated Cryogenic Propulsion Test Article (ICPTA), which was constructed for this project using assets from the former Morpheus Project rebuilt and outfitted with additional new hardware. The ICPTA utilizes one 2,800 lbf main engine, two 28 lbf and two 7 lbf reaction control engines mounted in two pods, four 48-inch propellant tanks (two each for liquid oxygen and liquid methane), and a cold helium system for propellant tank pressurization. Several hundred sensors on the ICPTA and many more in the test cell collected data to characterize the operation of the vehicle and facility. Multiple notable experiments were performed during this test campaign, many for the first time, including pressure-fed cryogenic reaction control system characterization over a wide range of conditions, coil-on-plug ignition system demonstration at the vehicle level, integrated main engine/RCS operation, and a non-intrusive propellant mass gauging system. The test data includes water-hammer and thermal heat leak data critical to validating models for use in future vehicle design activities. This successful test campaign demonstrated the performance of the updated Plum Brook In-Space Propulsion thermal vacuum chamber and incrementally advanced the state of LOX/Methane propulsion technology through numerous system-level and subsystem experiments.

Morehead, Robert L.↗

Structural Dynamic Testing Results for Air-Independent Proton Exchange Membrane (PEM) Fuel Cell Technologies for Space Applications

In 2016, the NASA Advanced Exploration Systems (AES) project office funded research at the NASA Glenn Research Center to evaluate the maturity of the Proton Exchange Membrane (PEM) fuel cell technology and its viability for supporting launch vehicle and space applications. This technology evaluation included vibration, reactant purity, and vacuum exposure sensitivity testing. The evaluation process did not include microgravity testing. This paper discusses the vibration sensitivity testing of two air-independent fuel cell stacks provided by different vendors to assess the ability of currently available fuel cell stack hardware to survive the projected random vibrational environment that would be encountered in an upper stage launch vehicle. Baseline performance testing was utilized to quantify stack performance and overboard leak rate at standard atmospheric conditions in order to provide a reference for post-test comparison. Both fuel cell stacks were tested at a random vibration qualification level of 10.4 grms for five minutes in each axis. Low-level sinusoidal sweeps were conducted before and after each random vibration level run to see if any significant change in resonances were detected. Following vibration facility testing, the baseline performance testing was repeated. Test results demonstrated no measurable change in fuel cell electrochemical or mechanical performance, indicating that the two evaluated PEM fuel cell stacks may be suitable for space applications pending microgravity testing.

Gilligan, Ryan P.↗

A ground test measurement system for the shuttle entry air data system

The Ground Test Measurement System (GTMS) for determining vacuum decay leak rate within the orifice tubing assembly of SEADS is described. The system can also monitor the absolute pressure in the tubing assembly under certain conditions. The GTMS determines leak rate by measuring vacuum-pressure decay which can be converted into leakage flow rate. Results of performance testing and operation of the GTMS are given.

Schutte, P. C.↗

Exploration Extravehicular Mobility Unit (xEMU) Chamber B Thermal Vacuum “Suit 2” Pressure Garment System Test Article Results

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation spacesuit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test results from the “Suit 2” Pressure Garment System (PGS) test article. The primary objective of the “Suit 2” PGS test article was to evaluate system-level suit heat leak and Environmental Protection Garment (EPG) thermal performance. Eleven unique thermal profiles were tested including both cold and hot environmental cases over the course of five continuous days of testing. The radiative thermal environment was controlled through exposure to liquid-nitrogen shrouds on the chamber walls and a heater cage surrounding the test article. This paper will principally focus on system-level thermal results from the “Suit 2” PGS test article. This paper will examine data collected from one-hundred and seventy thermocouples located in critical locations inside and outside of the suit, as well as seven resistance thermometers (RTDs) for calorimetry to determine total heat flux in and out of the suit. The test data will be compared against the system-level PGS thermal models for model validation. To conclude, this paper will address knowledge gaps presented by unmanned xPGS thermal vacuum testing and the current state of lunar xPGS thermal modeling and testing.

xEMU↗

Testing and modeling of diffusion bonded prototype optical windows under ITER conditions

Glass-metal joints are a part of ITER optical diagnostics windows. These joints must be leak tight for the safety (presence of tritium in ITER) and to preserve the vacuum. They must also withstand the ITER environment: temperatures up to 220 deg.C and fast neutron fluxes of {approx}3.10{sup 9} n/cm{sup 2}.s. At the moment, little information is available about glass-metal joints suitable for ITER. Therefore, we performed mechanical and thermal tests on some prototypes of an aluminium diffusion bonded optical window. Finite element modeling with Abaqus code was used to understand the experimental results. The prototypes were helium leaking probably due to very tiny cracks in the interaction layer between the steel and the aluminium. However, they were all able to withstand a thermal cycling test up to 200 deg. C; no damage could be seen after the tests by visual inspection. The prototypes successfully passed push-out test with a 500 N load. During the destructive push-out tests the prototypes broke at a 6-12 kN load between the aluminium layer and the steel or the glass, depending on the surface quality of the glass. The microanalysis of the joints has also been performed. The finite element modeling of the push-out tests is in a reasonable agreement with the experiments. According to the model, the highest thermal stress is created in the aluminium layer. Thus, the aluminium joint seems to be the weakest part of the prototypes. If this layer is improved, it will probably make the prototype helium leak tight and as such, a good ITER window candidate. (authors)

42 ENGINEERING↗

Study of multilayered insulation pipe penetration. Thermal acoustic oscillation

Tests were conducted to determine the net heat leak to a source of liquid nitrogen caused by a metal penetration through the blanket of multilayer insulation. The conditions under which the tests were conducted are described. A graph of the theoretical and experimental temperature distribution is developed for comparison. The variables involved in the computer program to process the data are defined. A study was conducted to develop analytical methods for predicting the effect and magnitudes of thermoacoustic oscillations on the penetration heat leak to cryogens. The oscillations develop as a result of large thermal gradients imposed on a compressible fluid. The predominant amplitudes and frequencies of the thermal acoustic oscillations were investigated.

Lovin, J. K.↗

Energy Efficient High-Pressure Turbine Leakage Technology Report

The leakage test program was one of such supporting technology programs structured to provide guidance to the Energy Efficient Engine High Pressure Turbine Component Design Effort. Leakage reduction techniques were identified and evaluated. Test models were used to simulate component leak paths and to evaluate leakage reduction techniques. These models simulated the blade/disk attachment, the vane inner platform attachment, and the vane outer platform attachment combined with the blade outer airseal. Disk blade attachment testing indicated that leakage in this area could be reduced to very low levels by paying careful attention to the tolerances along the contact surface between the blade vibration damper and the blade platform contact surface. The aim of feather seal testing was to achieve a goal for an effective leakage gap of one mil (.001 inch) per inch of feather seal length. Results indicated that effective gaps even below the goal level were achievable by (1) maintaining close tolerances between feather seals and their slots to minimize end gaps and limit seal rotation, (2) avoiding feather seal overlap, and (3) minimizing feather seal intersections. W seals were shown to be effective leakage control devices. Wire rope, in its present state of development, was shown not to be an effective sealing concept for application to the component design.

Gardner, W. B.↗

Hydrogen leak detection in the Space Shuttle

This study focuses on a helium gas jet flowing into room air. Measurements of helium concentration and velocity in the jet-air mixture are reported. The objective is to learn about jet characteristics so that dynamically similar hydrogen leaks may be located in the Space Shuttle. The hazardous gas detection system (HGDS) in the mobile launch pad uses mass spectrometers to monitor the shuttle environment for leaks. The mass spectrometers are fed by long sample tubes which draw gas from the payload bay, mid body, aft engine compartment and external tank. The overall purpose of this study is to improve the HGDS especially in its potential for locating hydrogen leaks. A rapid-response leak detection experiment was designed, built, and tested, following on the work done in this program last summer. The apparatus included a Perkin Elmer MGA-1200 mass spectrometer and air velocity transducer, both monitored by a Macintosh IIFX computer using LabVIEW software. A jet of helium flowing into the lab air simulated a gas leak. Steady helium or hydrogen-nitrogen jets were logged for concentration and velocity, and the power spectral density of each was computed. Last year, large eddies and vortices were visually seen with Schlieren imaging, and they were detected in the time plots of the various instruments. The response time of the MGA-1200 was found in the range of 0.05 to 0.1 sec. Pulsed concentration waves were clearly detected at 25 cycles per sec by spectral analysis of MGA data. No peaks were detected in the power spectrum, so in the present study, 10 Hz bandwidth-averaged power levels were examined at regular frequency intervals. The practical consequences of last year's study are as follows: sampling frequency should be increased above the present rate of 1 sample per second so that transients could be observed and analyzed with frequency response methods. Many more experiments and conditions were observed in this second summer, including the effects of orifice diameter, jet velocity, sample tube design, radial effects, vertical flow, and low hydrogen concentrations (1 percent). A frequent observation was that the power spectrum, calculated from the Fourier transform of concentration fluctuations, gives a separate piece of information from concentration. Many of the tests suggest that power is high where mixing occurs at the helium-air interface. This fact is apparently independent of the concentration level, which could be high or low, but depends on the sample location relative to the jet (leak) origin, whereas high concentration may be due to a strong leak far away or a small leak close to the sample tube. If the power is low for any concentration level, this would signify helium is arriving at the sample tube by diffusion, not chaotic mixing caused by the jet interaction with air. The practical result is to propose a modification of the HGDL mass spectrometer data sampling and software so that sampling rates could be capable of observing at least 25 Hz fluctuations.

Barile, Ronald G↗

Evaluation of a Brayton cycle recuperator after 21,000 hours of ground testing

A metallographic examination was conducted on a Brayton cycle recuperator and associated ducting after 21,000 hours of ground testing in air. At the hot (turbine) end, the recuperator operated at a nominal temperature of 675 C. The type 347 stainless-steel recuperator performed satisfactorily in the ground test even though the primary working fluid leaked to the atmosphere periodically. The leakage path was located at plate-bar braze joints which cracked as a result of thermal stresses. The welded type 347 stainless steel ducting a type 347/Hastelloy X bellows survived the ground test with no apparent loss of ductility or integrity. Some apparent aging embrittlement was observed in the Hastelloy X ducting but the serviceability was not affected.

Moore, T. J.↗

SULI Report - Development of a Molten Salt Circulation Loop for in-situ Spectroscopy

This project supports the development of real time optical monitoring capabilities for molten salt reactor (MSR) environments by designing, testing, and refining a molten salt circulation loop suitable for combined laser induced breakdown spectroscopy (LIBS) and ultraviolet visible (UV Vis) absorption measurements. Online spectroscopic monitoring is increasingly important for nuclear safeguards, corrosion tracking, and material accountancy, yet MSR process fluids present substantial challenges due to their chemical complexity and hazards such as high temperatures and radiation. To address these needs, this work focuses on Phase I, the development of a room temperature aqueous circulation loop that serves as a surrogate platform for evaluating flow behavior, optical access, and component performance prior to high temperature salt operation. Initial testing identified several practical issues—including leaks, obstructions, and two-phase flow through the absorption cell—that were systematically resolved through hardware replacement, flow path redesign, and venturi pressure optimization. Relocating the flow cell upstream of the primary venturi enabled periods of stable single-phase flow, demonstrating the feasibility of integrating optical diagnostics into a circulation system. The results of Phase I provide essential design insight for Phase II, which will incorporate furnace compatible materials and LiCl KCl eutectic salt. Completion of the molten salt system will deliver a reusable testbed for evaluating multimodal spectroscopic techniques, advancing nondestructive, real time monitoring tools for future MSR and nuclear fuel cycle applications.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Onsite testing of pressure sampling

Portable test instrument containing controller, pressure port identification, 5-V power source for transducer excitation, and digital voltmeter to test pressure sampling valves completely, including leak and plug check before, during, or after installation in any location or environment. Controller comprises 117/24-Vac 100-watt transformer, bridge rectifier, capacitive-discharge stepper, and constant voltage source for homing sampling valve. It also includes 5-V regulated power supply and bipolar digital voltmeter having 10-uV resolution.

Mallory, R.↗

Technology for robotic surface inspection in space

This paper presents on-going research in robotic inspection of space platforms. Three main areas of investigation are discussed: machine vision inspection techniques, an integrated sensor end-effector, and an orbital environment laboratory simulation. Machine vision inspection utilizes automatic comparison of new and reference images to detect on-orbit induced damage such as micrometeorite impacts. The cameras and lighting used for this inspection are housed in a multisensor end-effector, which also contains a suite of sensors for detection of temperature, gas leaks, proximity, and forces. To fully test all of these sensors, a realistic space platform mock-up has been created, complete with visual, temperature, and gas anomalies. Further, changing orbital lighting conditions are effectively mimicked by a robotic solar simulator. In the paper, each of these technology components will be discussed, and experimental results are provided.

Volpe, Richard↗

Real-Time Model-Based Leak-Through Detection within Cryogenic Flow Systems

The timely detection of leaks within cryogenic fuel replenishment systems is of significant importance to operators on account of the safety and economic impacts associated with material loss and operational inefficiencies. Associated loss in control of pressure also effects the stability and ability to control the phase of cryogenic fluids during replenishment operations. Current research dedicated to providing Prognostics and Health Management (PHM) coverage of such cryogenic replenishment systems has focused on the detection of leaks to atmosphere involving relatively simple model-based diagnostic approaches that, while effective, are unable to isolate the fault to specific piping system components. The authors have extended this research to focus on the detection of leaks through closed valves that are intended to isolate sections of the piping system from the flow and pressurization of cryogenic fluids. The described approach employs model-based detection of leak-through conditions based on correlations of pressure changes across isolation valves and attempts to isolate the faults to specific valves. Implementation of this capability is enabled by knowledge and information embedded in the domain model of the system. The approach has been used effectively to detect such leak-through faults during cryogenic operational testing at the Cryogenic Testbed at NASA's Kennedy Space Center.

Walker, M.↗

Simulating the Lunar Thermal Environment for the Surface-Deployed LEMS Artemis III TVAC Test

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. Presented is the system thermal vacuum test plan and configuration to validate the thermal control system performance in a flight-like environment. The test will measure the nighttime heat leaks for the bus and 18 seismometers to ensure lunar night survival and operability.

Thermal↗

Investigation of Lunar-Inspired Geopolymer Concrete Formulations Mixed and Cured in Microgravity on the International Space Station (ISS)

The research outlined in this presentation investigates the use of various lunar regolith simulants in geopolymer lunar concrete mixes mixed and cured on the International Space Station (ISS). The motivation for this work is to study the effects of gravity on the microstructure of alkali-activated materials cured with heat, and to develop materials for the construction of long-term infrastructure on the lunar surface with in-situ resource utilization (ISRU). ISRU for construction materials reduces the cost and mass of payloads related to lunar construction. The advantage of geopolymer concrete as opposed to traditional portland cement concrete is that water acts as a medium for the polymerization reaction and leaves the system throughout the process, reducing its demand. Twelve samples of lunar regolith simulant and a solution composed of sodium hydroxide and sodium silicate were sent to the ISS. The three simulants were OPRH2N, OPRL2N, and JSC-1AF, using only particles less than 53 µm in diameter to increase reactivity of the simulant. Simulant to solution ratios were determined by workability while mixing. The simulant and solution were sealed Burst Pouches® along with 2 other sealed bags to prevent material from leaking. Crew member F-14 conducted testing on the ISS by introducing the solution to the simulant in the Burst Pouch®, mixing the sample with a spatula, and then clamping the specimen in the fresh state to prevent flow inside the Burst Pouch®. These specimens were then put in a thermos heated to 80C via sealed drinking water bags to cure for 24 hours with a temperature logger. The cured specimens remained in microgravity for at least 28 days and were returned from the ISS in February 2025. The specimens were then brought to the NASA Marshall Space Flight Center (MSFC) to analyze. Material characterization consisted of conducting Micro-CT tests of entire samples in their sealed apparatus to a resolution of 25µm. 2D image slices were saved in each orthogonal direction of each specimen at a 0.03 mm step size from the 3D model to conduct analytical porosity calculations. Representative samples from each specimen were sampled to perform helium gas pycnometery and were then mounted in resin for SEM imaging, EDS, and nanoindentation. Porosity was analyzed analytically using micromechanics modelling with the assistance of the NASA Multiscale Analysis Tool (NASMAT), as well as the NASA Advanced Supercomputing (NAS) servers (V. Saseendran & N. Yamamoto, 2024). Density was measured using helium gas pycnometery and was then compared to the theoretical density for experimental porosity calculation. Due to the samples’ non-uniform shape being cured in a pouch, traditional compression and tensile strength testing could not be performed. Nanoindentation was conducted at Clarkson University to determine the microhardness and reduced modulus of elasticity. Results from flight samples can be compared to ground samples currently in DLR’s possession to determine the effect on microstructure from being mixed and cured in microgravity. This study gives further insight and understanding of geopolymer lunar concrete and its viability as a lunar construction material with ISRU.

Adam Johnson↗

Simulating the Lunar Thermal Environment for the Surface-Deployed LEMS Artemis III TVAC Test

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. Presented is the system thermal vacuum test plan and configuration to validate the thermal control system performance in a flight-like environment. The test will measure the nighttime heat leaks for the bus and 18 seismometers to ensure lunar night survival and operability.

Thermal↗

Simulating the Lunar Thermal Environment for the Surface-Deployed LEMS Artemis III TVAC Test

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. Presented is the system thermal vacuum test plan and configuration to validate the thermal control system performance in a flight-like environment. The test will measure the nighttime heat leaks for the bus and 18 seismometers to ensure lunar night survival and operability.

TVAC↗