Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Detecting Vascular-Targeting Effects of the Hypoxic Cytotoxin Tirapazamine in Tumor Xenografts Using Magnetic Resonance Imaging

Purpose: To determine whether vascular-targeting effects can be detected in vivo using magnetic resonance imaging (MRI). Methods and Materials: MR images of HCT-116 xenograft-bearing mice were acquired at 7 Tesla before and 24 hours after intraperitoneal injections of tirapazamine. Quantitative dynamic contrast-enhanced MRI analyses were performed to evaluate changes in tumor perfusion using two biomarkers: the volume transfer constant (K{sup trans}) and the initial area under the concentration-time curve (IAUC). We used novel implanted fiducial markers to obtain cryosections that corresponded to MR image planes from excised tumors; quantitative immunohistochemical mapping of tumor vasculature, perfusion, and necrosis enabled correlative analysis between these and MR images. Results: Conventional histological analysis showed lower vascular perfusion or greater amounts of necrosis in the central regions of five of eight tirapazamine-treated tumors, with three treated tumors showing no vascular dysfunction response. MRI data reflected this result, and a striking decrease in both K{sup trans} and IAUC values was seen with the responsive tumors. Retrospective evaluation of pretreatment MRI parameters revealed that those tumors that did not respond to the vascular-targeting effects of tirapazamine had significantly higher pretreatment K{sup trans} and IAUC values. Conclusions: MRI-derived parameter maps showed good agreement with histological tumor mapping. MRI was found to be an effective tool for noninvasively monitoring and predicting tirapazamine-mediated central vascular dysfunction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Prospective Study of the Utility of Magnetic Resonance Imaging in Determining Candidacy for Partial Breast Irradiation

Purpose: Retrospective data have demonstrated that breast magnetic resonance imaging (MRI) may change a patient's eligibility for partial breast irradiation (PBI) by identifying multicentric, multifocal, or contralateral disease. The objective of the current study was to prospectively determine the frequency with which MRI identifies occult disease and to establish clinical factors associated with a higher likelihood of MRI prompting changes in PBI eligibility. Methods and Materials: At The University of Chicago, women with breast cancer uniformly undergo MRI in addition to mammography and ultrasonography. From June 2009 through May 2011, all patients were screened prospectively in a multidisciplinary conference for PBI eligibility based on standard imaging, and the impact of MRI on PBI eligibility according to National Surgical Adjuvant Breast and Bowel Project protocol B-39/Radiation Therapy Oncology Group protocol 0413 entry criteria was recorded. Univariable analysis was performed using clinical characteristics in both the prospective cohort and in a separate cohort of retrospectively identified patients. Pooled analysis was used to derive a scoring index predictive of the risk that MRI would identify additional disease. Results: A total of 521 patients were screened for PBI eligibility, and 124 (23.8%) patients were deemed eligible for PBI based on standard imaging. MRI findings changed PBI eligibility in 12.9% of patients. In the pooled univariable analysis, tumor size ≥2 cm on mammography or ultrasonography (P=.02), age <50 years (P=.01), invasive lobular histology (P=.01), and HER-2/neu amplification (P=.01) were associated with a higher likelihood of MRI changing PBI eligibility. A predictive score was generated by summing the number of significant risk factors. Patients with a score of 0, 1, 2, and 3 had changes to eligibility based on MRI findings in 2.8%, 13.2%, 38.1%, and 100%, respectively (P<.0001). Conclusions: MRI identified additional disease in a significant number of patients eligible for PBI, based on standard imaging. Clinical characteristics may be useful in directing implementation of MRI in the staging of PBI candidates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of screening of resonant magnetic perturbations in three dimensional edge plasma transport simulations for DIII-D

The impact of resonant magnetic perturbations (RMPs) on the plasma edge can be analyzed in detail by three dimensional computer simulations, which take the underlying magnetic field structure as input. Previously, the 'vacuum approximation' has been used to calculate the magnetic field structure although plasma response effects may result in a screening (or even an amplification) of the external perturbations. Simulation results for an ITER similar shape plasma at the DIII-D tokamak are presented for the full vacuum perturbation field and an ad hoc screening case in comparison to the unperturbed configuration. It is shown that the RMP induced helical patterns in the plasma edge and on the divertor target shrink once screening is taken into account. However, a flat temperature profile is still found in the 'open field line domain' inside the separatrix, while the 'density pump out effect' found in the vacuum RMP case is considerably weakened.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear magnetic resonance studies of pseudospin fluctuations in URu 2 Si 2

Here, we report 29 Si nuclear magnetic resonance measurements in single crystals and aligned powders of URu 2 Si 2 in the hidden order and paramagnetic phases. The spin-lattice relaxation data reveal evidence of pseudospin fluctuations of U moments in the paramagnetic phase. We find evidence for partial suppression of the density of states below 30 K and analyze the data in terms of a two-component spin-fermion model. We propose that this behavior is a realization of a pseudogap between the hidden-order transition T HO and 30 K. This behavior is then compared to other materials that demonstrate precursor fluctuations in a pseudogap regime above a ground state with long-range order.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sealed magic angle spinning nuclear magnetic resonance probe and process for spectroscopy of hazardous samples

A magic-angle-spinning (MAS) nuclear magnetic resonance (NMR) probe is described that includes double containment enclosures configured to seal and contain hazardous samples for analysis. The probe is of a modular design that ensures containment of hazardous samples during sample analysis while preserving spin speeds for superior NMR performance and convenience of operation.

36 MATERIALS SCIENCE↗

Effects of edge-localized electron cyclotron current drive on edge-localized mode suppression by resonant magnetic perturbations in DIII-D

Abstract According to recent DIII-D experiments (Logan et al 2024 Nucl. Fusion 64 014003), injecting edge localized electron cyclotron current drive (ECCD) in the counter-plasma-current (counter- I p ) direction reduces the n = 3 resonant magnetic perturbation (RMP) current threshold for edge-localized mode (ELM) suppression, while co- I p ECCD during the suppressed ELM phase causes a back transition to ELMing. This paper presents nonlinear two-fluid simulations on the ECCD manipulation of edge magnetic islands induced by RMP using the TM1 code. In the presence of a magnetic island chain at the pedestal-top, co- I p ECCD is found to decrease the island width and restore the initially degraded pedestal pressure when its radial deposition location is close to the rational surface of the island. With a sufficiently strong co- I p ECCD current, the RMP-driven magnetic island can be healed, and the pedestal pressure fully recovers to its initial ELMing state. On the contrary, counter- I p ECCD is found to increase the island width and further reduce the pedestal pressure to levels significantly below the peeling-ballooning-mode limited height, leading to even stationary ELM suppression. These simulations align with the results from DIII-D experiments. However, when multiple magnetic island chains are present at the pedestal-top, the ECCD current experiences substantial broadening, and its effects on the island width and pedestal pressure become negligible. Further simulations reveal that counter- I p ECCD enhances RMP penetration by lowering the penetration threshold, with the degree of reduction proportional to the amplitude of ECCD current. For the ∼1 MW ECCD in DIII-D, the predicted decrease in the RMP penetration threshold for ELM suppression is approximately 20%, consistent with experimental observations. These simulations indicate that edge-localized ECCD can be used to either facilitate RMP-driven ELM suppression or optimize the confinement degradation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gyrokinetic study of collisional resonant magnetic perturbation (RMP)-driven plasma density and heat transport in tokamak edge plasma using a magnetohydrodynamic screened RMP field

The total-f gyrokinetic particle-in-cell code XGC is applied to study various aspects of collisional transport in the tokamak edge pedestal in the presence of resonant magnetic perturbations (RMPs) calculated with M3D-C1. Simulations including the separatrix and scrape-off layer are exercised for a model DIII-D H-mode plasma. Neutral particle recycling is modeled by means of ionization and charge exchange with the plasma. A fully nonlinear Fokker–Planck collision operator is utilized to account for non-Maxwellian edge plasma. Here, the study yields kinetic evidence that (i) neglecting the non-axisymmetric component of the RMP-generated electrostatic potential perturbation could yield a fictitiously high particle pump-out rate in the edge pedestal; that (ii) the experimental level of particle pump-out from the pedestal cannot be provided by collisional transport across Kolmogorov–Arnold–Moser surfaces except across the magnetic separatrix where stochastic magnetic field lines exist; that (iii) the H-mode type electron heat barrier is retained in the steep slope area under the M3D-C1 calculated RMPs; and that (iv) the stochastic electron heat-transport rate around the magnetic separatrix surface is much lower than the prediction by Rechester–Rosenbluth (1978 Phys. Rev. Lett. 40 38–41) and is qualitatively consistent with the experimentally observed rate. Detailed kinetic physics analysis on how the transport fluxes, electrostatic potential perturbation, and -well structure respond to onset of RMPs is also reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proton Dynamics in ZnO Nanorods Quantified by In Situ Solid-State 1H Nuclear Magnetic Resonance

Zinc oxide (ZnO) adopts wurtzite structure and possesses a direct wide band gap (Eg ~ 3.3 eV at 300 K), similar to that of GaN (Eg ~ 3.4 eV at 300 K), which enables ZnO as an alternative candidate to replace GaN for use in optoelectronic devices. The present controversy is centered at the microscopic origin of the “native donors”, particularly after ab initio calculations by Van de Walle, which indicate that hydrogen is soluble in ZnO at the interstitial sites, effectively forming a donor level just below the conduction band in ZnO. Hence, the origin of n type conductivity in ZnO is proposed due to the presence of hydrogen. Electron paramagnetic resonance and spectroscopic observations of muons provide experimental evidence of hydrogen presence in ZnO. Whereas, Look et al. suggests that the complex of zinc interstitial and nitrogen defect is a stronger candidate for donor than hydrogen interstitials under N ambient. Hydrogen-oxygen complex is claimed to be stable even at T > 1000°C in the hydrothermally synthesized ZnO. Therefore, the thermodynamic nature of hydrogen characteristics remains controversial, particularly its role on resident defects. In this letter, in situ temperature dependent solid state 1H magic angle spinning (MAS) nuclear magnetic resonance (NMR) spectroscopy is employed to probe the local chemical environments of hydrogen in ZnO nanorods. To best knowledge of ours, this is the first time that the presence of hydrogen, its concentration, and local transport dynamics are directly chemically determined. Moreover, in situ NMR allows a new approach to investigate the absorption and desorption of protons from different sites on the ZnO nanorods, thus study of site-specific proton dynamics in ZnO becomes feasible.

08 HYDROGEN↗

Characterization of dangling bond defects at the crystalline Si/SiO x interface in a polycrystalline Si passivating contact solar cell at room temperature with electrically detected magnetic resonance spectroscopy

Monocrystalline silicon solar cells can achieve photoconversion efficiencies exceeding 26%; however, performance-limiting defects that trap carriers continue to be a challenge. In this work, we have characterized Si solar cells with tunneling SiO x /polycrystalline-Si (poly-Si) passivating contacts (TOPCon) on As-doped Czochralski Si wafers with electrically detected magnetic resonance (EDMR) spectroscopy. We fabricated 2 × 20 mm 2 TOPCon-like mini solar cells with edge passivation alongside larger 4 cm 2 sister cells and obtained similar device characteristics. We performed EDMR spectroscopy at 300 K on two minicells with different degrees of surface passivation based on the recombination parameter, J o , values of 40 and 310 fA/cm2. We optimized the resolution and the signal-to-noise ratio of the EDMR response of the minicells by varying the forward bias voltage and the magnetic field modulation amplitude. We detect two distinct signals with EDMR spectroscopy, an axial-like signal at g = 2.009, 2.0087, and 2.0015, and an isotropic signal at g = 2.0024, which we attribute to Si dangling bonds (P b0 and P b centers) and boron–oxygen related defects, respectively, at or near the c-Si/SiO x interface. The EDMR signals were lower for the cell with a lower value of J o , while the ratio of the two defect populations was very similar. The EDMR signal increases with forward bias but drops to zero at bias voltages >0.5 V, consistent with interface defects within or near the boron-doped emitter depletion region. Our study demonstrates a method to fabricate minicells that can be characterized with EDMR spectroscopy to detect industrially relevant defects in TOPCon cells.

14 SOLAR ENERGY↗

Micro-coil detection of nuclear magnetic resonance for nanofluidic samples

We have developed a novel dc SQUID system with a micro-coil input circuit to act as a local probe of quantum matter and nanosystems. The planar niobium micro-coil pickup loop is located remotely from the SQUID, coupled through a superconducting twisted pair. A high degree of coupling between the coil and the region of interest of similar dimensions (up to ∼ 100 microns) can be achieved. We report nuclear magnetic resonance (NMR) measurements to characterise the sensitivity of these coils to {sup 3}He in the gas phase at 4.2 K in a 30 mT magnetic field.

36 MATERIALS SCIENCE↗

Monodispersed Spherical Nanoparticles Gd{sub x}Si{sub y}O{sub z}:Eu{sup 3+} for Magnetic Resonance Tomography and Optical Imaging

The melt method is used for synthesizing monodispersed spherical silica nanoparticles Gd{sub x}-Si{sub y}O{sub z}:Eu{sup 3+}. The particle diameter is 450 nm, and the standard deviation does not exceed 5%. The nanoparticles have a line luminescence spectrum with a dominant band at 614 nm. The effect of a constant magnetic field up to 15 T on the intensity and shape of the luminescence spectra of Eu{sup 3+} ions is studied. It is shown that the obtained material has a stable photoluminescence, the intensity of which does not depend on the magnetic field in the entire studied range. The synthesized nanoparticles Gd{sub x}Si{sub y}O{sub z} : Eu{sup 3+} are promising for use as a contrast agent for magnetic resonance tomography and luminescent marker.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Advancements in Orthopedic Intervention: Retrograde Drilling and Bone Grafting of Osteochondral Lesions of the Knee Using Magnetic Resonance Imaging Guidance

Computer-assisted surgery is currently a novel challenge for surgeons and interventional radiologists. Magnetic resonance imaging (MRI)-guided procedures are still evolving. In this experimental study, we describe and assess an innovative passive-navigation method for MRI-guided treatment of osteochondritis dissecans of the knee. A navigation principle using a passive-navigation device was evaluated in six cadaveric knee joint specimens for potential applicability in retrograde drilling and bone grafting of osteochondral lesions using MRI guidance. Feasibility and accuracy were evaluated in an open MRI scanner (1.0 T Philips Panorama HFO MRI System). Interactive MRI navigation allowed precise drilling and bone grafting of osteochondral lesions of the knee. All lesions were hit with an accuracy of 1.86 mm in the coronal plane and 1.4 mm the sagittal plane. Targeting of all lesions was possible with a single drilling. MRI allowed excellent assessment of correct positioning of the cancellous bone cylinder during bone grafting. The navigation device and anatomic structures could be clearly identified and distinguished throughout the entire drilling procedure. MRI-assisted navigation method using a passive navigation device is feasible for the treatment of osteochondral lesions of the knee under MRI guidance and allows precise and safe drilling without exposure to ionizing radiation. This method may be a viable alternative to other navigation principles, especially for pediatric and adolescent patients. This MRI-navigated method is also potentially applicable in many other MRI-guided interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Volume Differences for Computed Tomography and Magnetic Resonance Imaging Segmentation and Planning for Proton Prostate Cancer Therapy

Purpose: To determine the influence of magnetic-resonance-imaging (MRI)-vs. computed-tomography (CT)-based prostate and normal structure delineation on the dose to the target and organs at risk during proton therapy. Methods and Materials: Fourteen patients were simulated in the supine position using both CT and T2 MRI. The prostate, rectum, and bladder were delineated on both imaging modalities. The planning target volume (PTV) was generated from the delineated prostates with a 5-mm axial and 8-mm superior and inferior margin. Two plans were generated and analyzed for each patient: an MRI plan based on the MRI-delineated PTV, and a CT plan based on the CT-delineated PTV. Doses of 78 Gy equivalents (GE) were prescribed to the PTV. Results: Doses to normal structures were lower when MRI was used to delineate the rectum and bladder compared with CT: bladder V50 was 15.3% lower (p = 0.04), and rectum V50 was 23.9% lower (p = 0.003). Poor agreement on the definition of the prostate apex was seen between CT and MRI (p = 0.007). The CT-defined prostate apex was within 2 mm of the apex on MRI only 35.7% of the time. Coverage of the MRI-delineated PTV was significantly decreased with the CT-based plan: the minimum dose to the PTV was reduced by 43% (p < 0.001), and the PTV V99% was reduced by 11% (p < 0.001). Conclusions: Using MRI to delineate the prostate results in more accurate target definition and a smaller target volume compared with CT, allowing for improved target coverage and decreased doses to critical normal structures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Clinical Implementation of a Novel Magnetic Resonance Tracking Device for Real-Time Brachytherapy Catheter Positioning

Purpose: We designed and built dedicated active magnetic resonance (MR)-tracked (MRTR) stylets. We explored the role of MRTR in a prospective clinical trial. Methods and Materials: Eleven gynecologic cancer patients underwent MRTR to rapidly optimize interstitial catheter placement. MRTR catheter tip location and orientation were computed and overlaid on images displayed on in-room monitors at rates of 6 to 16 frames per second. Three modes of actively tracked navigation were analyzed: coarse navigation to the approximate region around the tumor; fine-tuning, bringing the stylets to the desired location; and pullback, with MRTR stylets rapidly withdrawn from within the catheters, providing catheter trajectories for radiation treatment planning (RTP). Catheters with conventional stylets were inserted, forming baseline locations. MRTR stylets were substituted, and catheter navigation was performed by a clinician working inside the MRI bore, using monitor feedback. Results: Coarse navigation allowed repositioning of the MRTR catheters tips by 16 mm (mean), relative to baseline, in 14 ± 5 s/catheter (mean ± standard deviation [SD]). The fine-tuning mode repositioned the catheter tips by a further 12 mm, in 24 ± 17 s/catheter. Pullback mode provided catheter trajectories with RTP point resolution of ∼1.5 mm, in 1 to 9 s/catheter. Conclusions: MRTR-based navigation resulted in rapid and optimal placement of interstitial brachytherapy catheters. Catheters were repositioned compared with the initial insertion without tracking. In pullback mode, catheter trajectories matched computed tomographic precision, enabling their use for RTP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Paramagnetic Mn 8 Fe 4 -co-Polystyrene Nanobeads as a Potential T 1 –T 2 Multimodal Magnetic Resonance Imaging Contrast Agent with In Vivo Studies

In developing a cluster-nanocarrier design, as a magnetic resonance imaging contrast agent, we have investigated the enhanced relaxivity of a manganese and iron-oxo cluster grafted within a porous polystyrene nanobead with increased relaxivity due to a higher surface area. The synthesis of the cluster-nanocarrier for the cluster Mn 8 Fe 4 O 12 (O 2 CC 6 H 4 CH=CH 2 ) 16 (H 2 O) 4 , cross-linked with polystyrene (the nano-carrier), under miniemulsion conditions is described. By including a branched hydrophobe, iso-octane, the resulting nanobeads are porous and similar to 70 nm in diameter. The increased surface area of the nanobeads compared to nonporous nanobeads leads to an enhancement in relaxivity; r 1 increases from 3.8 to 5.2 ± 0.1 mM -1 s -1 , and r 2 increases from 11.9 to 50.1 ± 4.8 mM -1 s -1 , at 9.4 teslas, strengthening the potential for T 1 and T 2 imaging. Several metrics were used to assess stability, and the porosity produced no reduction in metal stability. Synchrotron X-ray fluorescence microscopy was used to demonstrate that the nanobeads remain intact in vivo . In depth, physicochemical characteristics were determined, including extensive pharmacokinetics, in vivo imaging, and systemic biodistribution analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spin transport, magnetoresistance, and electrically detected magnetic resonance in amorphous hydrogenated silicon nitride

We report on a study of spin transport via electrically detected magnetic resonance (EDMR) and near-zero field magnetoresistance (MR) in silicon nitride films. Silicon nitrides have long been important materials in solid state electronics. Although electronic transport in these materials is not well understood, electron paramagnetic resonance studies have identified a single dominating paramagnetic defect and have also provided physical and chemical descriptions of the defects, called K centers. Our EDMR and MR measurements clearly link the near-zero field MR response to the K centers and also indicate that K center energy levels are approximately 3.1 eV above the a-SiN:H valence band edge. In addition, our results suggest an approach for the study of defect mediated spin-transport in inorganic amorphous insulators via variable electric field and variable frequency EDMR and MR which may be widely applicable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Computational study of runaway electrons in MST tokamak discharges with applied resonant magnetic perturbation

A numerical study of magnetohydrodynamics (MHD) and tracer-particle evolution investigates the effects of resonant magnetic perturbations (RMPs) on the confinement of runaway electrons (REs) in tokamak discharges conducted in the Madison Symmetric Torus. In computational results of applying RMPs having a broad toroidal spectrum but a single poloidal harmonic, m = 1 RMP does not suppress REs, whereas m = 3 RMP achieves significant deconfinement but not the complete suppression obtained in the experiment. MHD simulations with the NIMROD code produce sawtooth oscillations, and the associated magnetic reconnection can affect the trajectory of REs starting in the core region. Simulations with m = 3 RMP produce chaotic magnetic topology over the outer region, but the m = 1 RMP produces negligible changes in field topology, relative to applying no RMP. Using snapshots of the MHD simulation fields, full-orbit relativistic electron test particle computations with KORC show ≈50% loss from the m = 3 RMP compared to the 10%–15% loss from the m = 1 RMP. Here, test particle computations of the m = 3 RMP in the time-evolving MHD simulation fields show correlation between MHD activity and late-time particle losses, but total electron confinement is similar to computations using magnetic-field snapshots.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Resonance Frequency Shifts of Spin-Polarized Cesium Atoms in a Cs–Rb Mixture

The interaction of spin-polarized cesium atoms with cesium and rubidium atoms under conditions of optical orientation of atoms is considered. On the basis of data on spin-exchange complex cross sections in the Cs–Cs and Cs–Rb systems, a calculation of a magnetic resonance frequency shift of cesium atoms in a Cs–Rb mixture, as well as comparison of the calculated values of the frequency shift with experimental data, is performed.

74 ATOMIC AND MOLECULAR PHYSICS↗