Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEASURING METHODS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Introducing a Markov chain-based time calibration procedure for multi-channel particle detectors: application to the SuperFGD and ToF detectors of the T2K experiment

Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability.

calibration and fitting methods↗

A new approach to study adsorption on shales and other microporous solids via the thermogravimetric analysis (TGA) technique

Measuring the adsorption of gases in microporous solids like the shales requires accurate knowledge of the solid’s skeletal volume. Helium (He) is commonly used to determine the sample’s skeletal volume based on the assumption that it does not adsorb in these porous media. The validity of such an assumption for microporous solids has been questioned in recent years, and in this study, we show that it is not applicable for the shale sample studied. We present a new method to measure the adsorption of shale-gas components in shales, which does not require the use of He to measure the solid’s skeletal volume. Since the proposed analysis method relies on the use of dynamic adsorption data, we also propose here a new zero-point correction method for the magnetic suspension balance, which is better suited for the analysis of such data. Here, we employ the new technique to the study of Argon adsorption in Marcellus Shales.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Establishing the accuracy of position–specific carbon isotope analysis of propane by GC–pyrolysis–GC–IRMS

Rationale: Position-specific (PS) δ 13 C values of propane have proven their ability to provide valuable information on the evolution history of natural gases. Two major approaches to measure PS δ 13 C values of propane are isotopic 13 C nuclear magnetic resonance (NMR) and gas chromatography-pyrolysis-gas chromatography-isotope ratio mass spectrometry (GC-Py-GC-IRMS). Measurement accuracy of the isotopic 13 C NMR has been verified, but the requirements of large sample size and long experimental time limit its applications. GC-Py-GC-IRMS is a more versatile method with a small sample size, but its accuracy has not been demonstrated. Methods: We measured the PS δ 13 C values of propane from nine natural gases using both 13 C NMR and GC-Py-GC-IRMS, then evaluated the accuracy of the GC-Py-GC-IRMS method. Results: The results show that large carbon isotope fractionations occurred for both terminal and central carbons within propane during pyrolysis. The isotope fractionations during the pyrolysis are reproducible at optimum conditions, but vary between the two GC-Py-GC-IRMS systems tested, affected by experimental conditions (e.g., pyrolysis temperature, flow rate, and reactor conditions). Conclusions: It is necessary to evaluate and calibrate each GC-Py-GC-IRMS system using propane gases with accurately determined PS δ 13 C values. Finally, this study also highlights a need for PS isotope standards for propane and other molecules (e.g., butane and acetic acid).

03 NATURAL GAS↗

A Measurement-Based Adaptive Voltage Regulation Method Considering Topology Changes

This paper proposes an online adaptive data-driven distributed energy resource (DER) dispatch optimization method for voltage control considering topology changes. By using a local sensitivity factor (LSF)-enabled voltage control, traditional DER control can be reformulated into a linear programming (LP) problem, leading to faster computation speeds. Power injection alteration and topology changes are two common operational changes in the distribution network that can affect the LSF and voltage control performance. To address this issue, a robust estimation method is developed to adjust the sensitivity matrix at each time step for the time-varying power injection changes. When topology changes occur, only the allocated predominant LSF submatrices are updated based on measurement data, allowing for a fast adaptation to the system reconfiguration. Results obtained from a real distribution feeder in Southern California demonstrate its robustness as compared to traditional volt-var control and constant LSF matrix dispatch control methods.

DERs↗

Triton Field Trials (TFiT) underwater noise - University of New Hampshire Living Bridge turbine Processed Data

In July 2021, a commercial-off-the-shelf hydrophone was deployed in a free-drifting configuration to measure underwater acoustic emissions and characterize a 25 kW-rated tidal turbine at the University of New Hampshire's Living Bridge Project in Portsmouth, New Hampshire. Sampling methods and analysis were performed in alignment with the recently published IEC 62600-40 Technical Specification for acoustic characterization of marine energy converters. Results from this study indicate acoustic emissions from the turbine were below ambient sound levels and therefore did not have a significant impact on the underwater noise levels of the project site. As a component of Pacific Northwest National Laboratory's Triton Field Trials (TFiT) described in a paper published in a Special Issue of Journal of Marine Energy Science and Engineering, this study provides a valuable use case for the IEC 62600-40 Technical Specification framework and further recommendations for cost-effective technologies and methods for measuring underwater noise at future current energy converter project sites. The paper can be accessed in the link bellow.

16 TIDAL AND WAVE POWER↗

Underwater Noise Measurements around a Tidal Turbine in a Busy Port Setting

Acoustic emissions from current energy converters remain an environmental concern for regulators because of their potential effects on marine life and uncertainties about their effects stemming from a lack of sufficient observational data. Several recent opportunities to characterize tidal turbine sound emissions have begun to fill knowledge gaps and provide a context for future device deployments. In July 2021, a commercial-off-the-shelf hydrophone was deployed in a free-drifting configuration to measure underwater acoustic emissions and characterize a 25 kW-rated tidal turbine at the University of New Hampshire’s Living Bridge Project in Portsmouth, New Hampshire. Sampling methods and analysis were performed in alignment with the recently published IEC 62600-40 Technical Specification for acoustic characterization of marine energy converters. Results from this study indicate acoustic emissions from the turbine were below ambient sound levels and therefore did not have a significant impact on the underwater noise levels of the project site. As a component of Pacific Northwest National Laboratory’s Triton Field Trials (TFiT) described in this Special Issue, this effort provides a valuable use case for the IEC 62600-40 Technical Specification framework and further recommendations for cost-effective technologies and methods for measuring underwater noise at future current energy converter project sites.

tidal turbine↗

Simultaneous determination of electrical conductivity and thickness of nonmagnetic metallic foils using two-sided multifrequency eddy current techniques

Here, in this paper, we describe a simple method for performing multifrequency eddy current characterization of free-standing uniform-thickness metallic foils using a forked inductive coil arrangement. The method involves measuring the mutual inductance between two coils when a foil is present between the coils, and when it is not present; the ratio of these mutual inductances is compared with an analytical solution, and foil conductivity, thickness, and sheet resistance are simultaneously estimated using numerical inversion and least-squares fitting. This method was used to characterize 34 non-ferrous metallic samples with thicknesses between 50 and 640 μm and with conductivities between 0.8 × 10 7 and 5.8 × 10 7 S/m. The estimated thicknesses from eddy current characterization agreed well with those measured using confocal optical techniques; the two approaches agreed to within 1 μm for samples that were thinner than 200 μm, and to within 0.5% for samples that had a thickness of 200 μm or greater. The estimated conductivities from eddy current characterization were in close agreement with expected values, given knowledge of the materials used. A particular strength of this approach is that the instrumentation needed is broadly available in research and development laboratories and the associated fixturing is easy to manufacture and assemble. A calibration procedure is described that can be used to reduce errors from geometric uncertainties. This calibration requires a sample that has only a known conductivity or thickness; both do not need to be known. The method described herein is likely extensible to conductivities and thickness well outside the ranges measured as part of this work.

47 OTHER INSTRUMENTATION↗

Dynamical structure factors of warm dense matter from time-dependent orbital-free and mixed-stochastic-deterministic density functional theory

Abstract We present the first calculations of the inelastic part of the dynamical structure factor (DSF) for warm dense matter (WDM) using time-dependent orbital-free density functional theory (TD-OF-DFT) and mixed-stochastic-deterministic (mixed) Kohn Sham TD-DFT (KS TD-DFT). WDM is an intermediate phase of matter found in planetary cores and laser-driven experiments, where the accurate calculation of the DSF is critical for interpreting x-ray Thomson scattering measurements. Traditional TD-DFT methods, while highly accurate, are computationally expensive, motivating the exploration of TD-OF-DFT and mixed TD-KS-DFT as more efficient alternatives. We applied these methods to experimentally measured WDM systems, including solid-density aluminum and beryllium, compressed beryllium, and carbon–hydrogen mixtures. Our results show that TD-OF-DFT requires a dynamical kinetic energy potential in order to qualitatively capture the plasmon response. Additionally, it struggles with capturing bound electron contributions. In contrast, mixed TD-KS-DFT offers greater accuracy in distinguishing bound and free electron effects, aligning well with experimental data, though at a higher computational cost. This study highlights the trade-offs between computational efficiency and accuracy, demonstrating that TD-OF-DFT remains a valuable tool for rapid scans of parameter space, while mixed TD-KS-DFT should be preferred for high-fidelity simulations. Our findings provide insight into the future development of DFT methods for WDM and suggest potential improvements for TD-OF-DFT.

36 MATERIALS SCIENCE↗

BACCHUS Analysis of Weak Lines in APOGEE Spectra (BAWLAS)

Elements with weak and blended spectral features in stellar spectra are challenging to measure and require specialized analysis methods to precisely measure their chemical abundances. In this work, we have created a catalog of approximately 120,000 giants with high signal-to-noise Apache Point Observatory Galactic Evolution Experiment (APOGEE) Data Release 17 (DR17) spectra, for which we explore weak and blended species to measure Na, P, S, V, Cu, Ce, and Nd abundances and 12 C/ 13 C isotopic ratios. We employ an updated version of the Brussels Automatic Code for Characterizing High-accuracy Spectra (BACCHUS) code to derive these abundances using the stellar parameters measured by APOGEE's DR17 Stellar Parameters and Chemical Abundances Pipeline, quality flagging to identify suspect spectral lines, and a prescription for upper limits. Combined, these allow us to provide our BACCHUS Analysis of Weak Lines in APOGEE Spectra catalog of precise chemical abundances for these weak and blended species, which agrees well with the literature and improves upon APOGEE abundances for these elements, some of which are unable to be measured with APOGEE's current, grid-based approach without computationally expensive expansions. This new catalog can be used alongside APOGEE and provides measurements for many scientific applications ranging from nuclear physics to Galactic chemical evolution and Milky Way population studies. To illustrate this we show some examples of uses for this catalog, such as showing that we observe stars with enhanced s-process abundances or that we can use the 12 C/ 13 C ratios to explore extra mixing along the red giant branch.

79 ASTRONOMY AND ASTROPHYSICS↗

The completed SDSS-IV extended baryon oscillation spectroscopic survey: pairwise-inverse probability and angular correction for fibre collisions in clustering measurements

ABSTRACT The completed extended Baryon Oscillation Spectroscopic Survey (eBOSS) catalogues contain redshifts of 344 080 quasars at 0.8 < z < 2.2, 174 816 luminous red galaxies between 0.6 < z < 1.0, and 173 736 emission-line galaxies over 0.6 < z < 1.1 in order to constrain the expansion history of the Universe and the growth rate of structure through clustering measurements. Mechanical limitations of the fibre-fed spectrograph on the Sloan telescope prevent two fibres being placed closer than 62 arcsec in a single pass of the instrument. These ‘fibre collisions’ strongly correlate with the intrinsic clustering of targets and can bias measurements of the two-point correlation function resulting in a systematic error on the inferred values of the cosmological parameters. We combine the new techniques of pairwise-inverse probability and the angular upweighting (PIP+ANG) to correct the clustering measurements for the effect of fibre collisions. Using mock catalogues, we show that our corrections provide unbiased measurements, within data precision, of both the projected $\rm {\mathit{ w}_p}\left(\mathit{ r}_p\right)$ and the redshift-space multipole ξ(ℓ = 0, 2, 4)(s) correlation functions down to $0.1\, h^{-1}{\rm Mpc}$, regardless of the tracer type. We apply the corrections to the eBOSS DR16 catalogues. We find that, on scales $s\gtrsim 20\, h^{-1}{\rm Mpc}$ for ξℓ, as used to make baryon acoustic oscillation and large-scale redshift-space distortion measurements, approximate methods such as nearest-neighbour upweighting are sufficiently accurate given the statistical errors of the data. Using the PIP method, for the first time for a spectroscopic program of the Sloan Digital Sky Survey, we are able to successfully access the one-halo term in the clustering measurements down to $\sim 0.1\, h^{-1}{\rm Mpc}$ scales. Our results will therefore allow studies that use the small-scale clustering to strengthen the constraints on both cosmological parameters and the halo occupation distribution models.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal Conductivity Measurement of Microstructure in Irradiated Materials

Argonne National Laboratory is establishing additional capabilities for advanced techniques for accelerated experiment-based fuel material screening. A key supporting element is expanded capabilities for the characterization of irradiated samples, including establishment of the capability to measure irradiated fuel thermal conductivity at the micro-scale level. Argonne is collaborating with the University of Illinois at Urbana-Champaign (UIUC) to adopt the suspended bridge method to measure thermal conductivity of radiation-induced microstructures in nuclear materials directly. The initial phase of work to support thermal conductivity measurements of microstructure in irradiated materials at Argonne has been executed, and is summarized here. This report is intended to serve as a status update for this activity, summarizing work completed in FY20.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Operando Temperature Measurements of Photovoltaic Laser Power Converter Devices Under Continuous High-Intensity Illumination

Photovoltaic devices that operate under extremely high irradiances, such as laser power converters (LPCs), may also operate at elevated temperatures, even under active cooling, as the result of large temperature gradients. We demonstrate the operation of GaAs LPC devices under orders of magnitude of irradiances up to 150 W/cm 2 in a monochromatic laser simulator with an active cooling stage. The steady-state open-circuit voltage (V OC ) as a function of irradiance is known to droop at high irradiance as the result of junction heating, but the junction temperature can be difficult to measure by conventional methods. Fast, transient V OC measurements under these extreme operating conditions are used here to determine the junction temperature. Empirical V OC temperature coefficients of the devices at each irradiance of interest are determined and used as an integral part of this technique. We show that the thermal design of different LPC devices strongly affects the operating temperature of the junctions. Knowledge of the operating temperature can be a strong tool for understanding the nature of loss mechanisms and improving the design for the operation of photovoltaic LPCs at high irradiances. Furthermore, this technique can be used for laboratory devices during initial design as well as to characterize mass-produced and packaged devices for quality control.

14 SOLAR ENERGY↗

Microbial potentiometric sensor array measurements in unsaturated soils

The overarching goal of this study is to demonstrate a novel technology for monitoring changes in electrical potential of unsaturated soils using biofilm-populated electrodes. The novelty of the study stems from the fact that it demonstrates a method for measuring open-circuit potentials (OCP) in environments without the presence of an electrolyte solution. This study also reveals that using a biofilm-populated electrode as a reference in stable environments could successfully be employed to assess and monitor the electrochemical potential generated by plants and microorganisms. The findings imply that long-term (months to years) and real-time measurements of the open-circuit potential in unsaturated soils are possible. Because MPS arrays can directly measure open-circuit potential from the biofilm, the challenges related to locally induced electrochemical changes caused by microorganisms in the soil to achieve optimum physiological levels are eliminated. The simplicity of the technology, which allows for multiple indicator electrodes to be referenced against an “internal” reference electrode, enables spatial-temporal monitoring of the changes in the soil and the generation of 2D- or 3D-signal patterns. Once a signal pattern, generated by an array of sensors, develops (usually after 30 to 90 days), it does not significantly change unless the soil is exposed to external stimuli. The observed OCP phenomena, however, suggests that the change in OCP signal is independent of changes in soil conductivity resulting from the addition of water. In brief, findings suggest that the proposed technology can enable multidimensional profiling and long-term monitoring of changes occurring in unsaturated soils without direct implications of presence of water. The changes in the 2D or 3-D signal patterns, however, can be correlated to other important parameters that characterize soil health.

54 ENVIRONMENTAL SCIENCES↗

Measuring Light Yield with Isolated Protons in MicroBooNE

Liquid Argon Time Projection Chambers (LArTPCs) are precision detectors used extensively in neutrino physics. The MicroBooNE experiment at Fermilab is one of the experiments employing this technique and has collected 5 years of data from 2015-2021. The primary signal in LArTPCs is ionisation, but argon also emits large quantities of scintillation light, which can be used for calorimetry, timing and background rejection. Prompt scintillation light in MicroBooNE is recorded with an array of 32 PhotoMultiplier Tubes (PMTs). To enable the full use of scintillation light in the experiment, it is important to characterize the efficiency of light collection in the detector, i.e. the light yield. We present a new method of measuring the light yield using isolated proton interactions, which enables a position-dependent light yield measurement to map the response of the detector across its volume. This method can be used to calibrate the light response in large-scale LArTPC detectors as well as to test assumptions used in simulating scintillation light.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gas Permeability Test Protocol for Ion-Exchange Membranes

The membrane-based electrolysis of water is a growing topic of interest due to the advantages of employing membranes in hydrogen production efficiency and system safety over the traditional alkaline water electrolysis. Ion-exchange membranes with low gas permeability are highly desirable for stable and safe operation of membrane-based water-splitting technologies, hence gas permeability through ion-exchange membranes needs to be properly assessed with standardized methods. We addressed three methods to measure gas permeability of ion-exchange membranes, a pressure permeation cell, chronoamperometry microelectrodes, and in situ testing of the membrane electrode assembly, and provide a guideline for choosing the appropriate method for the targeted operating conditions of the water electrolyzers.

08 HYDROGEN↗

Uncertainty analysis of Raman spectra for measuring ortho-parahydrogen compositions

Determining ortho-parahydrogen compositions at cryogenic temperatures is an important quality control for liquid hydrogen custody exchange. High orthohydrogen compositions lead to an exothermic reaction resulting in increased boil off and increased venting losses of liquid hydrogen product by either the supplier or consumer. Traditional methods for measuring ortho-parahydrogen compositions such as hot-wire anemometry, nuclear magnetic resonance, and infrared spectroscopy are typically inconvenient at best. As the number of cryogenic hydrogen systems continue to increase, there is an increased need for flexible, standardized techniques for post processing composition measurements. A Raman spectrometer implemented in the Cryo-Catalysis Hydrogen Experimental Facility (CHEF) has demonstrated incredible flexibility for composition measurements of cryogenic hydrogen flows through a wide range of temperatures and pressures with the Raman probe in-situ at cryogenic temperatures. This article analyzes the uncertainty of Raman spectroscopy data of cryogenic hydrogen equilibrated at temperatures in IONEX catalyst. Spectra from hydrogen catalyzed to the equilibrium ortho-parahydrogen composition are processed and compared to expected statistical distributions for method verification.

08 HYDROGEN↗

Measuring Q₀ in LCLS-II Cryomodules Using Helium Liquid Level

The nitrogen-doped cavities used in the Linac Coherent Light Source II (LCLS-II) cryomodules have shown an unprecedented high Q₀ in vertical and cryomodule testing compared with cavities prepared with standard methods. While demonstration of high Q₀ in the test stand has been achieved, maintaining that performance in the linac is critical to the success of LCLS-II and future accelerator projects. The LCLS-II cryomodules required a novel method of measuring Q₀, due to hardware incompatibilities with existing procedures. Initially developed at Jefferson Lab during cryomodule acceptance testing before being used in the tunnel at SLAC, we use helium liquid level data to estimate the heat generated by cavities. We first establish the relationship between the rate of helium evaporation from known heat loads using electric heaters, and then use that relationship to determine heat from an RF load. Here we present the full procedure along with the development process, lessons learned, and reproducibility while demonstrating for the first time that world record Q₀ can be maintained within the real accelerator environment.

43 PARTICLE ACCELERATORS↗

Integral Heat Transfer Test Method for Determining Thermal Resistance of Silicon Carbide Cladding and Liquid Tin System at Elevated Temperatures - Master's Thesis Presentation University of Idaho

Presentation for master's work at University of Idaho discussing Integral Heat Transfer Test Method for Determining Thermal Resistance of Silicon Carbide Cladding and Liquid Tin System at Elevated Temperatures. Presentation covers slight literature review results/previous work, discussions on system design and approach for thermal property measurement of SiC composite and Tin system, modeling efforts, and results.

36 - MATERIALS SCIENCE↗