Search NASA⌕ Search

SEARCH · Search NASA

Results for “Materials Test Module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Design, Modeling, and Testing of a Novel Inductor for Electric Vehicles: Iron Nitride Soft Magnetic Composites

New technology for electric vehicles (EVs) must meet the requirements of higher energy usage, lower costs, and more sustainable source materials. One promising material for EV power system components is iron nitride (IN) soft magnetic composites (SMCs) because of their competitive magnetic properties and high abundance of the source materials. As part of an ongoing program at Sandia National Laboratories, this project focused on using computer modeling to optimize the prototyping process for an iron nitride SMC toroidal inductor to reach a target inductance of 600 μH. Four inductors with different combinations of wiring (26 AWG and 20 AWG) and vol% loading of iron nitride (65 vol% and 50 vol%) were fabricated at Cal Poly and characterized using an LCR meter. These inductors were also modeled using COMSOL Multiphysics™ with the Magnetic Fields module. The inductance data from the experiment and the model show that the 65 vol% IN prototypes and models agree with about 8% difference, while the 50 vol% IN samples show about a 9% difference between the prototype and the model. These results suggest that the model can predict inductance with both accuracy and precision with low confidence for the given sample size of four. An additional parameter of AC resistance is studied but the AC resistance results from the inductors and from the model generally do not agree closely, suggesting that the current model used in the project does not fully capture the mechanisms behind AC resistance of the inductor. With the focus of the project on inductance, the percent difference results of less than 9% across the four inductors that were tested increases confidence in the model’s predictive capabilities for inductance only. Using the inductance results from both the model and experiment, the final suggested inductor design is a 65 vol% core with 150 windings of 20 AWG wire that is 8 cm across and 1.5 cm tall to reach the inductance goal of 600 μH based on analysis using the optimized COMSOLTM model.

33 ADVANCED PROPULSION SYSTEMS↗

Predictors of Radiation Pneumonitis in Patients Receiving Intensity Modulated Radiation Therapy for Hodgkin and Non-Hodgkin Lymphoma

Purpose: Few studies to date have evaluated factors associated with the development of radiation pneumonitis (RP) in patients with Hodgkin lymphoma (HL) and non-Hodgkin lymphoma (NHL), especially in patients treated with contemporary radiation techniques. These patients represent a unique group owing to the often large radiation target volumes within the mediastinum and to the potential to receive several lines of chemotherapy that add to pulmonary toxicity for relapsed or refractory disease. Our objective was to determine the incidence and clinical and dosimetric risk factors associated with RP in lymphoma patients treated with intensity modulated radiation therapy (IMRT) at a single institution. Methods and Materials: We retrospectively reviewed clinical charts and radiation records of 150 consecutive patients who received mediastinal IMRT for HL and NHL from 2009 through 2013. Clinical and dosimetric predictors associated with RP according to Radiation Therapy Oncology Group (RTOG) acute toxicity criteria were identified in univariate analysis using the Pearson χ{sup 2} test and logistic multivariate regression. Results: Mediastinal radiation was administered as consolidation therapy in 110 patients with newly diagnosed HL or NHL and in 40 patients with relapsed or refractory disease. The overall incidence of RP (RTOG grades 1-3) was 14% in the entire cohort. Risk of RP was increased for patients who received radiation for relapsed or refractory disease (25%) versus those who received consolidation therapy (10%, P=.019). Several dosimetric parameters predicted RP, including mean lung dose of >13.5 Gy, V{sub 20} of >30%, V{sub 15} of >35%, V{sub 10} of >40%, and V{sub 5} of >55%. The likelihood ratio χ{sup 2} value was highest for V{sub 5} >55% (χ{sup 2} = 19.37). Conclusions: In using IMRT to treat mediastinal lymphoma, all dosimetric parameters predicted RP, although small doses to large volumes of lung had the greatest influence. Patients with relapsed or refractory lymphoma who received salvage chemotherapy and hematopoietic stem cell transplantation were at higher risk for symptomatic RP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prototype muon detectors for the AMIGA component of the Pierre Auger Observatory

AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to extend its range of detection and to directly measure the muon content of the particle showers. It consists of an infill of surface water-Cherenkov detectors accompanied by buried scintillator detectors used for muon counting. The main objectives of the AMIGA engineering array, referred to as the Unitary Cell, are to identify and resolve all engineering issues as well as to understand the muon-number counting uncertainties related to the design of the detector. The mechanical design, fabrication and deployment processes of the muon counters of the Unitary Cell are described in this document. These muon counters modules comprise sealed PVC casings containing plastic scintillation bars, wavelength-shifter optical fibers, 64 pixel photomultiplier tubes, and acquisition electronics. The modules are buried approximately 2.25 m below ground level in order to minimize contamination from electromagnetic shower particles. The mechanical setup, which allows access to the electronics for maintenance, is also described in addition to tests of the modules' response and integrity. As a result, the completed Unitary Cell has measured a number of air showers of which a first analysis of a sample event is included here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Development of Compact HTS Coil Modules for Large Bore High Field Superconducting Magnets

Lower cost, high current density superconducting coil modules producing higher magnetic fields and cooled affordably are crucial for obtaining cost-effective, compact commercial fusion reactors. Accessibility to low cost, higher field magnets (>30 T) is also critical for the discovery of new quantum phenomena in materials, cosmic frontier and other topics in basic science research. The Princeton Plasma Physics Laboratory (PPPL) is working with Princeton University to develop unique large bore, compact superconducting magnets to support science experiments including the development of new instrumentation for condensed matter physics and Axion dark matter search in the cosmic frontier. Core elements of these experiments are unique for access to lower cost, simple fabrication of compact superconducting magnets that can be cooled affordably, while integrated with dedicated science instruments. Conductor qualification and coil design concepts are discussed in support of needs for these experiments. PPPL has the unique expertise and experimental facilities to design, construct and test subscale coil modules for these projects. Compact high field coil modules were fabricated and tested to validate coil design concepts and coil performance. Finally, the design and model coil integration challenges are discussed to identify performance risks and demonstrate feasibility for deploying full scale large bore compact superconducting magnets for cost effective operations of multiple laboratory experiments.

axion dark matter↗

Adding Erlotinib to Chemoradiation Improves Overall Survival but Not Progression-Free Survival in Stage III Non-Small Cell Lung Cancer

Purpose: To test, in a single-arm, prospective, phase 2 trial, whether adding the epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor erlotinib to concurrent chemoradiotherapy for previously untreated, locally advanced, inoperable non-small cell lung cancer would improve survival and disease control without increasing toxicity. Methods and Materials: Forty-eight patients with previously untreated non-small cell lung cancer received intensity modulated radiation therapy (63 Gy/35 fractions) on Monday through Friday, with chemotherapy (paclitaxel 45 mg/m², carboplatin area under the curve [AUC] = 2) on Mondays, for 7 weeks. All patients also received the EGFR tyrosine kinase inhibitor erlotinib (150 mg orally 1/d) on Tuesday-Sunday for 7 weeks, followed by consolidation paclitaxel–carboplatin. The primary endpoint was time to progression; secondary endpoints were overall survival (OS), toxicity, response, and disease control and whether any endpoint differed by EGFR mutation status. Results: Of 46 patients evaluable for response, 40 were former or never-smokers, and 41 were evaluable for EGFR mutations (37 wild-type [WT] and 4 mutated [all adenocarcinoma]). Median time to progression was 14.0 months and did not differ by EGFR status. Toxicity was acceptable (no grade 5, 1 grade 4, 11 grade 3). Twelve patients (26%) had complete responses (10 WT, 2 mutated), 27 (59%) partial (21 WT, 2 mutated, 4 unknown), and 7 (15%) none (6 WT, 2 mutated, 1 unknown) (P=.610). At 37.0 months' follow-up (range, 3.6-76.5 months) for all patients, median OS time was 36.5 months, and 1-, 2-, and 5-year OS rates were 82.6%, 67.4%, and 35.9%, respectively; none differed by mutation status. Twelve patients had no progression, and 34 had local and/or distant failure. Eleven of 27 distant failures were in the brain (7 WT, 3 mutated, 1 unknown). Conclusions: Toxicity and OS were promising, but time to progression did not meet expectations. The prevalence of distant failures underscores the need for effective systemic therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity Modulated Radiation Therapy for Early-Stage Primary Gastric Diffuse Large B-Cell Lymphoma: Dosimetric Analysis, Clinical Outcome, and Quality of Life

Purpose: To evaluate the dosimetric superiority, efficacy, toxicity, and quality of life (QOL) data of intensity modulated radiation therapy (IMRT) in patients with primary gastric diffuse large B-cell lymphoma (PG-DLBCL). Methods and Materials: Forty-six consecutive patients with early-stage PG-DLBCL underwent IMRT after chemotherapy. The majority of patients (61.5%) were subclassified as the non-germinal center B cell–like subtype. Dosimetric parameters of the planning target volume (PTV) and organs at risk were assessed. Survival rates were depicted with the Kaplan-Meier method and compared with the log-rank test. Quality of life was evaluated using the QLQ-C30-STO22 questionnaires at the last follow-up contact. Results: The median PTV mean dose was 41.6 Gy. Only 0.73% of the PTV received <95% of the prescribed dose, indicating excellent target coverage. The median kidney V20 and liver V30 were 14.1% and 16.1%, respectively. The 5-year overall survival (OS), progression-free survival, and locoregional control rates for all patients were 80.4%, 75.0%, and 93.2%, respectively. Stage, lactate dehydrogenase level, and immunophenotype were significant prognostic factors for OS, and only stage was a significant factor for locoregional control. Consolidation IMRT in patients with complete response after chemotherapy resulted in significantly better OS and progression-free survival than salvage IMRT in patients with non-complete response. Two of 8 patients who had chronic liver disease experienced grade 4 or grade 5 acute hepatic failure after 4 to 5 cycles of rituximab-based chemotherapy and IMRT (40 Gy). No other serious acute or late toxicity was observed. The long-term global and functional QOL scales were excellent, with negligible symptom scales. Conclusions: Intensity modulated radiation therapy yielded excellent target coverage and critical tissue sparing and achieved favorable outcomes with acceptable toxicity and good long-term QOL in early-stage PG-DLBCL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Failure Analysis of a New Polyamide-Based Fluoropolymer-Free Backsheet After Combined-Accelerated Stress Testing

The viability of novel coextruded, fluoropolymer-free backsheets for photovoltaic (PV) modules has been questioned as a result of a large number of early-life backsheet failures in PV installations containing one of the earliest co-extruded polyamide (PA)-based backsheet to reach the market, “AAA.” New PV reliability testing protocols have been recently developed and applied to backsheets to reproduce failures observed in the field and evaluate the durability of novel backsheet materials and designs prior to commercialization. A new co-extruded PA-based backsheet was tested using combined-accelerated stress testing (C-AST) and demonstrated a greater lifetime than AAA, and some other fluoropolymer-based backsheets such as polyvinylidene fluoride. The improved PA-based backsheet also eventually failed by through-thickness cracking. Using surface and bulk material characterization techniques, we performed a comprehensive study of material properties before and after the stress testing. Aging of the backsheet resulted in an increase of surface roughness by erosion of the outer PA layer. However the failure is more likely related to an increase in crystallinity of the polyolefin core layer reducing the backsheet tearing energy. The analysis can ultimately inform on the specific weaknesses of the materials so that the manufacturer can improve the backsheet design to extend its lifetime.

14 SOLAR ENERGY↗

Evaluation of the PID-s Susceptibility of Modules Encapsulated in Materials of Varying Resistivity

A common mechanism of potential-induced degradation is by shunting (PID-s) in PV modules, usually associated with the transport of sodium ions (Na+) through the encapsulant and penetrating the front junction of solar cells under voltage stress. Encapsulants with high volume resistivity have been suggested as a potentially cost-effective solution to this degradation mechanism. In this work, we examine three polyolefin elastomer (POE) encapsulants with volume resistivity varying over two orders of magnitude (ranging from 9 x 10^13 to 1 x 10^16 ..omega.. cm) that show equivalent and complete resistance to PID at the damp heat stress test level of 85 degrees C and 85% relative humidity and -1000 V system voltage stress. Performance is compared with a PID-susceptible ethylene vinyl acetate (EVA) encapsulant with resistivity 1 x 10^13 ..omega.. cm. The independence of PID susceptibility with respect to the resistivity of the polyolefin is attributed to the impermeability of POEs to Na + ions. Specific ions (i.e. Na + ), rather than charge-carrying species in general, are responsible for this degradation mechanism.

14 SOLAR ENERGY↗

Optimization of concentrator photovoltaic solar cell performance through photonic engineering

The goal of this program was to incorporate two new and innovative design concepts into the design and production of CPV cells that have near zero added cost, yet significantly increase the operational efficiency of CPV modules. The program focused developing luminescent coupling effects and radiative cooling layers to increase efficiency and suppress CPV module power losses due to spectral variations and heating. The major results of the program were: 1) The optics of three commercial refractive (Fresnel) concentrators were characterized and prevent application of radiative cooling concepts due to strong mid-IR absorption (4-12µm) required to effectively radiate blackbody radiation from the cells and provide cooling. Investigation of alternative materials for the concentrator lenses produced only undesirable options—materials with reasonable mid-IR transmission for cooling only had about 30-40 visible transmission, thus reducing incident sunlight by >50%. While our investigation was somewhat limited, our work suggests that the only viable concentrator system that can incorporate radiative cooling utilizes reflective optics. 2) With limited ability to test high concentration CPV cells (requires outdoor testing), we acquired both semi-crystalline and crystalline Si cells and tested them in our outdoor facility and demonstrated 4°C cooling using a simple silica layer coating on the cells. 3) Characterizing Si cells in the IR associated with radiative cooling, we observed very significant near-IR absorption that increases the cell operating temperature by a similar amount, 4-5°C. By appropriate surface layer design, one can produce a layer that is highly reflective in the near-IR (1.5-4µm) and highly emissive in the mid-IR (5-15µm), thus reducing cell operational temperature by 10°C and increasing efficiency by ~1% absolute. The radiative cooling effect in c-Si solar cells might be further improved by providing a higher thermal conductive elastomer for securing the cover glass on top of the AR-coating. Since it was never imagined that the front surface would provide any cooling for solar cells, thermal conductivity of this elastomer was never a design consideration, but, improving the conductivity could decrease cell temperature by another 3-4°C. The combined effect could be an ~1.5% absolute increase in cell and module efficiency, a very significant improvement. 4) Developed a numerical model to explore dependence of luminescent coupling efficiency over a broad range of operating conditions. We developed a novel method and facility to experimentally measure the luminescent coupling that can be used to confirm the dependence of luminescent coupling on multi-junction cell design parameters.

14 SOLAR ENERGY↗

Benchmark of Advanced Burner Test Reactor Model Using MCNPX 2.6.0 and ERANOS 2.1

Significant research is currently being performed whereby fast reactor cores have been designed to burn transuranic materials reducing the volume and long-term radiotoxicity of spent nuclear fuel. These core and depletion models depend on various computer codes. This research used MCNPX 2.6.0 and ERANOS 2.1 to model a standard 250MWt Advanced Burner Test Reactor (ABTR) core. The intent was to benchmark criticality and burnup results from a stochastic Monte Carlo code and a deterministic depletion code using a standard ABTR model created by Argonne National Laboratory. Because each of these codes solve the transport and burnup problem differently, there is a need to benchmark the core models in order to verify results and identify root causes for significant differences in results between codes. Flux calculations in ERANOS were performed using diffusion theory, Legendre polynomial approximations (using the VARIANT module) and discrete ordinates methods. The k-effective for the higher-order transport models remained within 1000 pcm of the MCNPX model. The difference between the total heavy nuclide mass balance in ERANOS using the various flux calculations and the MCNPX depletion model was less than 0.4% out to a burnup of 1095 days (67.45 GWd/MTHM). For individual heavy nuclides, the depletion models closely matched (< 5.0 % difference) throughout the depletion for isotopes of Uranium, Neptunium and Plutonium and most of the higher transuranics. Notable exceptions were 242Am, 242Cm, 243Cm and 246Cm where differences ranged from 0.1 – 0.2% after 26 days and increased to 11 - 136% at 1095 days.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Unacceptable Cosmesis in a Protocol Investigating Intensity-Modulated Radiotherapy With Active Breathing Control for Accelerated Partial-Breast Irradiation

Purpose: To report interim cosmetic results and toxicity from a prospective study evaluating accelerated partial-breast irradiation (APBI) administered using a highly conformal external beam approach. Methods and Materials: We enrolled breast cancer patients in an institutional review board-approved prospective study of APBI using beamlet intensity-modulated radiotherapy (IMRT) at deep-inspiration breath-hold. Patients received 38.5 Gy in 3.85 Gy fractions twice daily. Dosimetric parameters in patients who maintained acceptable cosmesis were compared with those in patients developing unacceptable cosmesis in follow-up, using t-tests. Results: Thirty-four patients were enrolled; 2 were excluded from analysis because of fair baseline cosmesis. With a median follow-up of 2.5 years, new unacceptable cosmesis developed in 7 patients, leading to early study closure. We compared patients with new unacceptable cosmesis with those with consistently acceptable cosmesis. Retrospective analysis demonstrated that all but one plan adhered to the dosimetric requirements of the national APBI trial. The mean proportion of a whole-breast reference volume receiving 19.25 Gy (V50) was lower in patients with acceptable cosmesis than in those with unacceptable cosmesis (34.6% vs. 46.1%; p = 0.02). The mean percentage of this reference volume receiving 38.5 Gy (V100) was also lower in patients with acceptable cosmesis (15.5% vs. 23.0%; p = 0.02). Conclusions: The hypofractionated schedule and parameters commonly used for external beam APBI and prescribed by the ongoing national trial may be suboptimal, at least when highly conformal techniques such as IMRT with management of breathing motion are used. The V50 and V100 of the breast reference volume seem correlated with cosmetic outcome, and stricter limits may be appropriate in this setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Prolonged Fraction Delivery Times Simulating IMRT on Cultured Nasopharyngeal Carcinoma Cell Killing

Purpose: To determine the impact of prolonged fraction delivery times (FDTs) simulating intensity-modulated radiotherapy (IMRT) on cultured nasopharyngeal carcinoma (NPC) cell killing. Methods and Material: Cultured NPC cell lines CNE1 and CNE2 were used in this study. The biological effectiveness of fractionated irradiation protocols simulating conventional external beam radiotherapy and IMRT (FDT of 15, 36, and 50 minutes) was estimated with standard colony assay, and the differences in cell surviving fractions after irradiation with different protocols were tested by use of the paired t test. The impact degree of prolonged FDTs (from 8 to 50 minutes) on cell killing was also assessed by the dose-modifying factors, which were estimated by comparing the effectiveness of intermittently delivered 2 Gy with that of continuously delivered 1.5 to 2 Gy. Results: The cell surviving fractions of both CNE1 and CNE2 after fractionated irradiation simulating IMRT were higher than those simulating conventional external beam radiotherapy (p < 0.05). The dose-modifying factors for a fraction dose of 2 Gy increased from 1.05 to 1.18 for CNE1 and from 1.05 to 1.11 for CNE2 with the FDT being prolonged from 15 to 50 minutes. Conclusions: This study showed that the prolonged FDTs simulating IMRT significantly decreased the cell killing in both CNE1 and CNE2 cell lines, and these negative effects increased with the FDT being prolonged from 15 to 50 minutes. These effects, if confirmed by in vivo and clinical studies, need to be considered in designing IMRT treatments for NPC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Setup Accuracy of the Novalis ExacTrac 6DOF System for Frameless Radiosurgery

Purpose: Stereotactic radiosurgery using frame-based positioning is a well-established technique for the treatment of benign and malignant lesions. By contrast, a new trend toward frameless systems using image-guided positioning techniques is gaining mainstream acceptance. This study was designed to measure the detection and positioning accuracy of the ExacTrac/Novalis Body (ET/NB) for rotations and to compare the accuracy of the frameless with the frame-based radiosurgery technique. Methods and Materials: A program was developed in house to rotate reference computed tomography images. The angles measured by the system were compared with the known rotations. The accuracy of ET/NB was evaluated with a head phantom with seven lead beads inserted, mounted on a treatment couch equipped with a robotic tilt module, and was measured with a digital water level and portal films. Multiple hidden target tests (HTT) were performed to measure the overall accuracy of the different positioning techniques for radiosurgery (i.e., frameless and frame-based with relocatable mask or invasive ring, respectively). Results: The ET/NB system can detect rotational setup errors with an average accuracy of 0.09 Degree-Sign (standard deviation [SD] 0.06 Degree-Sign ), 0.02 Degree-Sign (SD 0.07 Degree-Sign ), and 0.06 Degree-Sign (SD 0.14 Degree-Sign ) for longitudinal, lateral, and vertical rotations, respectively. The average positioning accuracy was 0.06 Degree-Sign (SD 0.04 Degree-Sign ), 0.08 Degree-Sign (SD 0.06 Degree-Sign ), and 0.08 Degree-Sign (SD 0.07 Degree-Sign ) for longitudinal, lateral and vertical rotations, respectively. The results of the HTT showed an overall three-dimensional accuracy of 0.76 mm (SD 0.46 mm) for the frameless technique, 0.87 mm (SD 0.44 mm) for the relocatable mask, and 1.19 mm (SD 0.45 mm) for the frame-based technique. Conclusions: The study showed high detection accuracy and a subdegree positioning accuracy. On the basis of phantom studies, the frameless technique showed comparable accuracy to the frame-based approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hematologic Toxicity in RTOG 0418: A Phase 2 Study of Postoperative IMRT for Gynecologic Cancer

Purpose: Intensity modulated radiation therapy (IMRT), compared with conventional 4-field treatment, can reduce the volume of bone marrow irradiated. Pelvic bone marrow sparing has produced a clinically significant reduction in hematologic toxicity (HT). This analysis investigated HT in Radiation Therapy Oncology Group (RTOG) 0418, a prospective study to test the feasibility of delivering postoperative IMRT for cervical and endometrial cancer in a multiinstitutional setting. Methods and Materials: Patients in the RTOG 0418 study were treated with postoperative IMRT to 50.4 Gy to the pelvic lymphatics and vagina. Endometrial cancer patients received IMRT alone, whereas patients with cervical cancer received IMRT and weekly cisplatin (40 mg/m{sup 2}). Pelvic bone marrow was defined within the treatment field by using a computed tomography density-based autocontouring algorithm. The volume of bone marrow receiving 10, 20, 30, and 40 Gy and the median dose to bone marrow were correlated with HT, graded by Common Terminology Criteria for Adverse Events, version 3.0, criteria. Results: Eighty-three patients were eligible for analysis (43 with endometrial cancer and 40 with cervical cancer). Patients with cervical cancer treated with weekly cisplatin and pelvic IMRT had grades 1-5 HT (23%, 33%, 25%, 0%, and 0% of patients, respectively). Among patients with cervical cancer, 83% received 5 or more cycles of cisplatin, and 90% received at least 4 cycles of cisplatin. The median percentage volume of bone marrow receiving 10, 20, 30, and 40 Gy in all 83 patients, respectively, was 96%, 84%, 61%, and 37%. Among cervical cancer patients with a V40 >37%, 75% had grade 2 or higher HT compared with 40% of patients with a V40 less than or equal to 37% (P =.025). Cervical cancer patients with a median bone marrow dose of >34.2 Gy also had higher rates of grade ≥2 HT than did those with a dose of ≤34.2 Gy (74% vs 43%, P=.049). Conclusions: Pelvic IMRT with weekly cisplatin is associated with low rates of HT and high rates of weekly cisplatin use. The volume of bone marrow receiving 40 Gy and the median dose to bone marrow correlated with higher rates of grade ≥2 toxicity among patients receiving weekly cisplatin (cervical cancer patients). Evaluation and limitation of the volume of bone marrow treated with pelvic IMRT is warranted in patients receiving concurrent chemotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment Planning System Calculation Errors Are Present in Most Imaging and Radiation Oncology Core-Houston Phantom Failures

Purpose: The anthropomorphic phantom program at the Houston branch of the Imaging and Radiation Oncology Core (IROC-Houston) is an end-to-end test that can be used to determine whether an institution can accurately model, calculate, and deliver an intensity modulated radiation therapy dose distribution. Currently, institutions that do not meet IROC-Houston's criteria have no specific information with which to identify and correct problems. In the present study, an independent recalculation system was developed to identify treatment planning system (TPS) calculation errors. Methods and Materials: A recalculation system was commissioned and customized using IROC-Houston measurement reference dosimetry data for common linear accelerator classes. Using this system, 259 head and neck phantom irradiations were recalculated. Both the recalculation and the institution's TPS calculation were compared with the delivered dose that was measured. In cases in which the recalculation was statistically more accurate by 2% on average or 3% at a single measurement location than was the institution's TPS, the irradiation was flagged as having a “considerable” institutional calculation error. The error rates were also examined according to the linear accelerator vendor and delivery technique. Results: Surprisingly, on average, the reference recalculation system had better accuracy than the institution's TPS. Considerable TPS errors were found in 17% (n=45) of the head and neck irradiations. Also, 68% (n=13) of the irradiations that failed to meet the IROC-Houston criteria were found to have calculation errors. Conclusions: Nearly 1 in 5 institutions were found to have TPS errors in their intensity modulated radiation therapy calculations, highlighting the need for careful beam modeling and calculation in the TPS. An independent recalculation system can help identify the presence of TPS errors and pass on the knowledge to the institution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical-Electrochemical-Thermal Simulation of Lithium-Ion Cells

Models capture the force response for single-cell and cell-string levels to within 15%-20% accuracy and predict the location for the origin of failure based on the deformation data from the experiments. At the module level, there is some discrepancy due to poor mechanical characterization of the packaging material between the cells. The thermal response (location and value of maximum temperature) agrees qualitatively with experimental data. In general, the X-plane results agree with model predictions to within 20% (pending faulty thermocouples, etc.); the Z-plane results show a bigger variability both between the models and test-results, as well as among multiple repeats of the tests. The models are able to capture the timing and sequence in voltage drop observed in the multi-cell experiments; the shapes of the current and temperature profiles need more work to better characterize propagation. The cells within packaging experience about 60% less force under identical impact test conditions, so the packaging on the test articles is robust. However, under slow-crush simulations, the maximum deformation of the cell strings with packaging is about twice that of cell strings without packaging.

25 ENERGY STORAGE↗

Quarterly Research Performance Progress Report (Q8)

As part of Task 1, we have started by testing our modeling capabilities by reproducing isothermal DFIT simulations presented in the literature. Once satisfied with the results we have started by targeting the modeling of the DFITs at conducted at well 58-32. We have a identified a specific test (cycle 4 in zone 2) as the most interesting to be model with GEOS hydraulic fracturing module. Thus, we have first produced results with an isothermal model and adjusted model parameters to get a satisfying match with field pressure data. The, we have added thermal effects and compared the modeling results with and without thermal effects to estimate how thermal effects may influence test interpretation. Models seem to suggest that, for small volumes of fluid, thermal effects are moderate. In Task 2, we have adapted GEOS phase-field formulation to be able to simulate near-wellbore hydraulic fracture nucleation and propagation. We have devised a novel formulation that, compared to other existing ones, incorporates rock strengths. We have submitted a journal publication about our work. We are currently employing this phase-field formulation to model the experiments taking place at U Pitt and help us understand the effect of various parameters. In Task 3, we have built a model of the region surround well 16A and have started modeling stage 3 stimulation because of its simpler planar geometry. After calibrating simulation parameters using known analytical solutions, we have simulated the stage 3 stimulation using our isothermal hydraulic fracturing module, varying the permeability field, the stress conditions including different physics to get a better understanding of the numerical challenges and of the effects of varying these parameters on the simulation results. In Task 4 laboratory experimentation, a set of specialized drilling and injection tools has been customized and constructed to accommodate an inclined well with an orientation of up to 30 degrees relative to material anisotropy or principal stress axes. These inclined samples have also undergone thermal stress and hydraulic fracturing at a temperature of 190 degrees Celsius. Furthermore, both vertical and deviated sampling testing setups enable an extended analysis of post-peak pressure behaviors, facilitating post-test pressure analyses such as the G-function, step rate, and fracture reopening measurements. Thus, the key components of in-situ stress estimation can be extracted and validated through our experiment, providing a solid foundation for validating existing in-situ stress estimation theories or proposing new ones. Simultaneously, we are integrating computer vision techniques with traditional experimental fracture observation methods such as multi-overcore/slicing and water-penetration fracture observation. This combination will prove beneficial in populating the hydraulic fracture patterns database, generated under challenging EGS conditions. This approach aims to deepen our understanding of the complexities in EGS reservoirs and pave the way for future data-driven investigations. Additionally, PITT has also equipped the ELE International compression machine, which is now prepared for conducting indirect tensile and fracture toughness tests. These tests will aid in characterizing how rock fabrics influence the resulting fracture patterns. Additionally, we have completed the required personnel training and gained access to Scanning Electron Microscopy (SEM) and Energy Dispersive Spectroscopy (EDS) for conducting more detailed characterization and analysis of rock fabrics, as well as the examination of thermal and hydraulically induced fracture patterns. Thus, the PITT team has effectively demonstrated the capabilities of our experimental apparatuses in exploring the thermal effects, well deviation angles, material anisotropy, and operational choices (such as circulation rate, injection fluid viscosity, and injection rate) and their impact on pressure responses and fracture trajectories under the Utah FORGE conditions.

15 GEOTHERMAL ENERGY↗

Preparation and Characterization of a Hydrophobic Metal-Organic Framework Membrane Supported on Thin Porous Metal Sheet

A hydrophobic metal-organic framework (MOF) UiO-66-CH3 is prepared and its solvothermal stability is investigated in comparison to UiO-66. It is confirmed that the MOF stability is enhanced by introduction of the two methyl groups, while the water adsorption is reduced. Given its hydrophobicity and stability, UiO-66-CH3 is proposed as an attractive membrane material for gas separation under moisture conditions. The UiO-66-CH3 membrane is prepared on a 50µm-thin porous Ni support sheet for the first time by use of a secondary growth method. It is found that uniform seed coating on the support is necessary to form a continuous membrane. In addition to growth time and temperature, presence of a modulator in the growth solution is found to be useful for controlling hydrothermal membrane growth on the seeded support. A dense, inter-grown membrane layer is formed by 24-h growth over a temperature range from 120 oC to 160 oC. The membrane surface comprises 500 nm octahedral crystals, which are supposed to grow out of the original 100 nm spherical seeding crystals. The separation characteristics of resulting membranes are tested with pure CO2, air, CO2/air mixture, and humid CO2/air mixture. CO2 permeance as high as 1.9E-06 mol/m2/s/Pa at 31oC is obtained. Unlike the hydrophilic zeolite membranes, CO2 permeation through this membrane is not blocked by the presence of water vapor in the feed gas. The results suggest that this MOF framework is a promising membrane material worth to be further investigated for separation of CO2 and other small molecules from humid gas mixtures.

Liu, Jian↗