Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Thermal Conductivity and Diffusivity for SiC Fibers for Use in ATF Cladding Composites

As part of the accident tolerant fuels (ATF) initiative, there is a need to understand the thermophysical properties of cladding for these fuels. One potential cladding material is silicon carbide (SiC) ceramic matrix composite reinforced with SiC fibers because of the corrosion resistance, resistance to hydrogen formation, high bulk thermal conductivity, and favorable mechanical properties of SiC. However, data about the thermal properties of individual SiC fibers in these composites is absent in the literature. This paper presents the measured axial thermal conductivity and thermal diffusivity of a leading SiC fiber (HiNicalon Type S) via a thermal measurement technique (transient electrothermal technique, TET) optimized for thin fibers. The results show that the measured properties are significantly lower than bulk values for SiC. Because of the low neutron absorption, as well as excellent thermal and mechanical properties, zircaloy has primarily been used for the fuel cladding in many nuclear reactors. A major drawback of the zircaloy is its hydrogen generation vulnerability. This issue has been known for some time, but the explosion of hydrogen accident in the Fukushima Daiichi nuclear disaster has motivated efforts for accident tolerant fuels (ATF) and their cladding as suitable substitutes for zircaloy. Fuel cladding made of silicon carbide (SiC) ceramic matrix composite (CMC) is an attractive alternative to the zircaloy. Investigation on the tubular monolithic a-SiC polytropes indicates that it has superior oxidation (hydrogen production) resistance (three orders of magnitude slower) than zircaloy. Additionally, it has well-documented, favorable mechanical properties, along with high temperature corrosion resistance. However, its bulk thermal properties can vary significantly depending on polytrope, the grain size, grain boundary, or impurities. At room temperature, SiC has a thermal conductivity as high as 490 Wm{sup -1}K{sup -1}, where the {sup 6}H polytrope has the highest conductivity. Thermal measurements of the SiC CMC are usually accomplished by laser flash method for thermal diffusivity (a) and thermal conductivity is indirectly calculated through the relationship k=aρcp. Depending on the manufacturing method and the reinforced fiber, the composite thermal conductivity varies from <10 Wm{sup -1}K{sup -1} to ∼70 Wm{sup -1}K{sup -1}. While the flash method is convenient for the measurement of the composite, it is difficult to apply to the measurement of individual fibers. Because of this, the thermal properties of individual SiC fibers is not present in the literature. Because the SiC fiber manufacturing process is different than that of the SiC matrix in the CMC, the properties of the bulk material might be erroneous when applied to the fiber. Being able to measure the fiber properties independently and directly allows for an understanding of the effect of the manufacturing process on the fiber and the opportunity to potentially improve or control the thermal properties of the composite. This improved accuracy can be achieved by measuring the fiber with a technique optimized for individual fiber measurement, known as the Transient Electrothermal Technique or TET. This paper presents the thermal conductivity and diffusivity of a leading SiC fiber (HiNicalon Type S). Measurements are performed with the TET, with the resulting properties being significantly lower than the bulk values of SiC, which is one possible explanation for relatively low CMC values. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of current density measurement methods for high-current, low-beta electron beams

Recent current density measurements with a low-beta electron beam (β=0.5-0.75) are strongly affected by electron scatter and Cherenkov limits. These invasive measurements are heavily influenced by the electron energy and the intercepting material properties: density, index of refraction, and atomic number. We evaluate various measurement methods, including x-ray scintillation and Cherenkov emission. To optimize the x-ray scintillation technique for this energy regime, metal foils of differing atomic number (Z) and thickness were placed upstream of a scintillation screen. We have selected Cherenkov emitters, based on a material refractive index, in order to differentiate the contributions from electron scatter and produced fluorescence, Cherenkov emission, and total internal reflection. The observed distributions for both approaches are verified through MCNP6®. Additionally, the simulations provide insight as to what physical processes dominate the measured distribution. We conclude by determining the limits and optimal measurement range for each measurement technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data-Driven Performance Optimization of Gamma Spectrometers With Many Channels

In gamma spectrometers with variable spectroscopic performance across many channels (e.g., many pixels or voxels), a tradeoff exists between including data from successively worse-performing readout channels and increasing efficiency. Brute-force calculation of the optimal set of included channels is exponentially infeasible as the number of channels grows, and approximate methods are required. In this work, we present a data-driven framework for attempting to find near-optimal sets of included detector channels. The framework leverages non-negative matrix factorization (NMF) to learn the behavior of gamma spectra across the detector and clusters similarly-performing detector channels together. Performance comparisons are then made between spectra with channel clusters removed, which is more feasible than brute force. The framework is general and can be applied to arbitrary, user-defined performance metrics depending on the application. We apply this framework to optimizing gamma spectra measured by H3D M400 CdZnTe (CZT) spectrometers, which exhibit variable performance across their crystal volumes. In particular, we show several examples optimizing various performance metrics for uranium and plutonium gamma spectra in non-destructive assay (NDA) for nuclear safeguards, and explore trends in performance versus parameters such as clustering algorithm type. We also compare the NMF + clustering pipeline to several non-machine-learning (ML) algorithms, including several greedy algorithms. Although, we find that the NMF + clustering pipeline tends to find the best-performing set of detector voxels, significantly improving over the unoptimized spectra, but that a greedy accumulation of spectra segmented by detector depth can, in some cases, give similar performance improvements in much less computation time.

Energy resolution↗

SU-F-T-620: Development of a Convolution/Superposition Dose Engine for CyberKnife System

Purpose: Current CyberKnife treatment planning system (TPS) provided two dose calculation algorithms: Ray-tracing and Monte Carlo. Ray-tracing algorithm is fast, but less accurate, and also can’t handle irregular fields since a multi-leaf collimator system was recently introduced to CyberKnife M6 system. Monte Carlo method has well-known accuracy, but the current version still takes a long time to finish dose calculations. The purpose of this paper is to develop a GPU-based fast C/S dose engine for CyberKnife system to achieve both accuracy and efficiency. Methods: The TERMA distribution from a poly-energetic source was calculated based on beam’s eye view coordinate system, which is GPU friendly and has linear complexity. The dose distribution was then computed by inversely collecting the energy depositions from all TERMA points along 192 collapsed-cone directions. EGSnrc user code was used to pre-calculate energy deposition kernels (EDKs) for a series of mono-energy photons The energy spectrum was reconstructed based on measured tissue maximum ratio (TMR) curve, the TERMA averaged cumulative kernels was then calculated. Beam hardening parameters and intensity profiles were optimized based on measurement data from CyberKnife system. Results: The difference between measured and calculated TMR are less than 1% for all collimators except in the build-up regions. The calculated profiles also showed good agreements with the measured doses within 1% except in the penumbra regions. The developed C/S dose engine was also used to evaluate four clinical CyberKnife treatment plans, the results showed a better dose calculation accuracy than Ray-tracing algorithm compared with Monte Carlo method for heterogeneous cases. For the dose calculation time, it takes about several seconds for one beam depends on collimator size and dose calculation grids. Conclusion: A GPU-based C/S dose engine has been developed for CyberKnife system, which was proven to be efficient and accurate for clinical purpose, and can be easily implemented in TPS.

60 APPLIED LIFE SCIENCES↗

Quantum state tomography with fully symmetric measurements and product measurements

We introduce random-matrix theory to study the tomographic efficiency of a wide class of measurements constructed out of weighted 2-designs, including symmetric informationally complete (SIC) probability operator measurements (POMs). In particular, we derive analytic formulas for the mean Hilbert-Schmidt distance and the mean trace distance between the estimator and the true state, which clearly show the difference between the scaling behaviors of the two error measures with the dimension of the Hilbert space. We then prove that the product SIC POMs, the multipartite analog of the SIC POMs, are optimal among all product measurements in the same sense as the SIC POMs are optimal among all joint measurements. We further show that, for bipartite systems, there is only a marginal efficiency advantage of the joint SIC POMs over the product SIC POMs. In marked contrast, for multipartite systems, the efficiency advantage of the joint SIC POMs increases exponentially with the number of parties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stochastic Waveform Estimation at the Fundamental Quantum Limit

Although measuring the deterministic waveform of a weak classical force is a well-studied problem, estimating a random waveform, such as the spectral density of a stochastic signal field, is much less well understood despite it being a widespread task at the frontier of experimental physics. State-of-the-art precision sensors of random forces must account for the underlying quantum nature of the measurement but the optimal quantum protocol for interrogating such linear sensors is not known. We derive the fundamental precision limit: the extended-channel quantum Cramér-Rao bound. In the experimentally relevant regime in which losses dominate, we prove that non-Gaussian-state preparation and measurement are required to achieve this fundamental limit and we determine numerically the optimal non-Gaussian protocol. We discuss how this scheme could accelerate searches for signatures of quantum gravity, stochastic gravitational waves, and axionic dark matter.

Axions↗

High-throughput feedback-enabled optogenetic stimulation and spectroscopy in microwell plates

Abstract The ability to perform sophisticated, high-throughput optogenetic experiments has been greatly enhanced by recent open-source illumination devices that allow independent programming of light patterns in single wells of microwell plates. However, there is currently a lack of instrumentation to monitor such experiments in real time, necessitating repeated transfers of the samples to stand-alone analytical instruments, thus limiting the types of experiments that could be performed. Here we address this gap with the development of the optoPlateReader (oPR), an open-source, solid-state, compact device that allows automated optogenetic stimulation and spectroscopy in each well of a 96-well plate. The oPR integrates an optoPlate illumination module with a module called the optoReader, an array of 96 photodiodes and LEDs that allows 96 parallel light measurements. The oPR was optimized for stimulation with blue light and for measurements of optical density and fluorescence. After calibration of all device components, we used the oPR to measure growth and to induce and measure fluorescent protein expression in E. coli . We further demonstrated how the optical read/write capabilities of the oPR permit computer-in-the-loop feedback control, where the current state of the sample can be used to adjust the optical stimulation parameters of the sample according to pre-defined feedback algorithms. The oPR will thus help realize an untapped potential for optogenetic experiments by enabling automated reading, writing, and feedback in microwell plates through open-source hardware that is accessible, customizable, and inexpensive.

59 BASIC BIOLOGICAL SCIENCES↗

Direct Measurement of Plutonium in Spent Fuel with X-ray Fluoresence

Currently, the only NDA technique that directly measures Pu in SNF involves XRF measurements. Measurements and simulations were used to demonstrate that with a properly - 15 - configured detector system, it is feasible to measure the Pu/U atom ratio at the surface of a fuel pin using measurements of the 103.7 keV K X-ray from Pu. Since the Pu/U atom ratio at the surface of the pin is directly related to the average Pu/U concentration for the pin, the technique might be applicable to measuring the Pu/U concentration in an LWR spent fuel pin. However, the technique requires knowledge of the fuel pin design and operating history to properly correlate surface Pu to average Pu for a pin. Fuel history information is available from operator declarations and can be verified by complementary measurements including gamma spectroscopy and passive gross neutron counts. While the count times of 4 to 12 hours used in these measurements were longer than would be acceptable in most applications, efforts are being made to improve counting time. These include the use of a segmented HPGe detector and reduction of Compton scattering background. These measurements are useful for individual fuel pins and provide a complementary, validating measurement for full assembly techniques. For future work, optimized detector systems and measurement approaches will be explored with the goal of measuring the Pu/U X-ray ratio with shorter count times. Measurements will be compared with the results of destructive analysis, which is to be completed this year, to provide a correlation between the measured Pu/U ratio and the total Pu/U ratio in the fuel. In addition, the sensitivity of this method to variations in system parameters will be studied to determine the expected accuracy of the technique.

Romano, Catherine E.↗

Constraints on Nuclear Symmetry Energy Parameters

A review is made of constraints on the nuclear symmetry energy parameters arising from nuclear binding energy measurements, theoretical chiral effective field predictions of neutron matter properties, the unitary gas conjecture, and measurements of neutron skin thicknesses and dipole polarizabilities. While most studies have been confined to the parameters 𝑆 𝑉 and L, the important roles played by, and constraints on 𝐾 sym , or, equivalently, the neutron matter incompressibility 𝐾 𝑁 , are discussed. Strong correlations among 𝑆 𝑉 ,𝐿, and 𝐾 𝑁 are found from both nuclear binding energies and neutron matter theory. However, these correlations somewhat differ in the two cases, and those from neutron matter theory have smaller uncertainties. To 68% confidence, it is found from neutron matter theory that 𝑆 𝑉 = 32.0 ± 1.1 MeV, 𝐿 = 51.9 ± 7.9 MeV and 𝐾 𝑁 = 152.2 ± 38.1 MeV. Theoretical predictions for neutron skin thickness and dipole polarizability measurements of the neutron-rich nuclei 48 Ca, 120 Sn, and 208 Pb are compared to recent experimental measurements, most notably the CREX and PREX neutron skin experiments from Jefferson Laboratory. By themselves, PREX I+II measurements of 208 Pb and CREX measurement of 48 Ca suggest 𝐿 = 121 ± 47 MeV and 𝐿 = −5 ± 40 MeV, respectively, to 68% confidence. However, we show that nuclear interactions optimally satisfying both measurements imply 𝐿 = 53 ± 13 MeV, nearly the range suggested by either nuclear mass measurements or neutron matter theory, and is also consistent with nuclear dipole polarizability measurements. This small parameter range implies 𝑅 1.4 = 11.6 ± 1.0 km and Λ 1.4 = 228$^{+148}_{−90}$, which are consistent with NICER X-ray and LIGO/Virgo gravitational wave observations of neutron stars.

neutron skins↗

Optimising the measurement of relativistic distortions in large-scale structure

It has been shown recently that relativistic distortions generate a dipolar modulation in the two-point correlation function of galaxies. To measure this relativistic dipole it is necessary to cross-correlate different populations of galaxies with for example different luminosities or colours. In this paper, we construct an optimal estimator to measure the dipole with multiple populations. We show that this estimator increases the signal-to-noise of the dipole by up to 35 percent. Using 6 populations of galaxies, in a survey with halos and number densities similar to those of the millennium simulation, we forecast a cumulative signal-to-noise of 4.4. For the main galaxy sample of SDSS at low redshift z ≤ 0.2 our optimal estimator predicts a cumulative signal-to-noise of 2.4. Finally we forecast a cumulative signal-to-noise of 7.4 in the upcoming DESI survey. These forecasts indicate that with the appropriate choice of estimator the relativistic dipole should be detectable in current and future surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Model Quality and Measurement Density Impact on Volt/Volt Ampere Reactive Optimization Performance

The operation of the utility grid is being reshaped by the continuous addition of distributed energy resources and advanced metering infrastructure, which challenge existing grid control strategies. Some utilities deploy advanced distribution management systems (ADMS) to assist with the consolidation of various applications and to augment situational awareness in response to the new power delivery dynamics. An ADMS is an integrated software platform that provides utilities with a way to enhance their reliability, control, and optimization with advanced applications, such as volt/VAR optimization (VVO). A VVO application could serve as a vehicle to deliver cost savings by providing the utility with a method to reduce rates by controlling the voltage and decreasing the energy usage in their service territory. Some utilities are reluctant to integrate an ADMS, because it is a significant investment that requires approval from the public regulatory commission and/or their customers. This paper evaluates the impact on VVO performance when using a lower-quality network model supplemented with additional measurements, which could provide an implementation for cost savings. The results show that a better model quality would provide the highest energy savings; however, some level of telemetry is necessary in all scenarios to prevent voltage exceedances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reducing Dose Uncertainty for Spot-Scanning Proton Beam Therapy of Moving Tumors by Optimizing the Spot Delivery Sequence

Purpose: To develop and validate a novel delivery strategy for reducing the respiratory motion–induced dose uncertainty of spot-scanning proton therapy. Methods and Materials: The spot delivery sequence was optimized to reduce dose uncertainty. The effectiveness of the delivery sequence optimization was evaluated using measurements and patient simulation. One hundred ninety-one 2-dimensional measurements using different delivery sequences of a single-layer uniform pattern were obtained with a detector array on a 1-dimensional moving platform. Intensity modulated proton therapy plans were generated for 10 lung cancer patients, and dose uncertainties for different delivery sequences were evaluated by simulation. Results: Without delivery sequence optimization, the maximum absolute dose error can be up to 97.2% in a single measurement, whereas the optimized delivery sequence results in a maximum absolute dose error of ≤11.8%. In patient simulation, the optimized delivery sequence reduces the mean of fractional maximum absolute dose error compared with the regular delivery sequence by 3.3% to 10.6% (32.5-68.0% relative reduction) for different patients. Conclusions: Optimizing the delivery sequence can reduce dose uncertainty due to respiratory motion in spot-scanning proton therapy, assuming the 4-dimensional CT is a true representation of the patients' breathing patterns.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantumness of noisy quantum walks: A comparison between measurement-induced disturbance and quantum discord

Noisy quantum walks are studied from the perspective of comparing their quantumness as defined by two popular measures, measurement-induced disturbance (MID) and quantum discord (QD). While the former has an operational definition, unlike the latter, it also tends to overestimate nonclassicality because of a lack of optimization over local measurements. Applied to quantum walks, we find that MID, while acting as a loose upper bound on QD, still tends to reflect correctly trends in the behavior of the latter. However, there are regimes where its behavior is not indicative of nonclassicality: in particular, we find an instance where MID increases with the application of noise, where we expect a reduction of quantumness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterizing and Optimizing Photocathode Laser Distributions for Ultra-low Emittance Electron Beam Operations

Photocathode RF gun has been widely used for generation of high-brightness electron beams for many different applications. We found that the drive laser distributions in such RF guns play important roles in minimizing the electron beam emittance. Characterizing the laser distributions with measurable parameters and optimizing beam emittance versus the laser distribution parameters in both spatial and temporal directions are highly desired for high-brightness electron beam operation. In this paper, we report systematic measurements and simulations of emittance dependence on the measurable parameters represented for spatial and temporal laser distributions at the photocathode RF gun systems of Linac Coherent Light Source. The tolerable parameter ranges for photocathode drive laser distributions in both directions are presented for ultra-low emittance beam operations.

ACCPHY↗

Development of an underground HPGe array facility for ultra low radioactivity measurements

Low Level Counting techniques using low background facilities are continuously under development to increase the possible sensitivity needed for rare physics events experiments. The CUP (Center for Underground Physics) group of IBS is developing, in collaboration with Canberra, a ultra low background instrument composed of two arrays facing each other with 7 HPGe detectors each. The low radioactive background of each detector has been evaluated and improved by the material selection of the detector components. Samples of all the building materials have been provided by the manufacturer and the contaminations had been measured using an optimized low background 100% HPGe with a dedicated shielding. The evaluation of the intrinsic background has been performed using MonteCarlo simulations and considering the contribution of each material with the measured contamination. To further reduce the background, the instrument will be placed in the new underground laboratory at YangYang exploiting the 700m mountain coverage and radon-free air supplying system. The array has been designed to perform various Ultra Low background measurements; the sensitivity we are expecting will allow not only low level measurements of Ra and Th contaminations in Copper or other usually pure materials, but also the search for rare decays. In particular some possible candidates and configurations to detect the 0νECEC (for example {sup 106}Cd and {sup 156}Dy) and rare β decays ({sup 96}Zr, {sup 180m}Ta , etc ) are under study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of Lyβ auto-correlations and Lyα-Lyβ cross-correlations in BOSS Data Release 9

The Lyman-β forest refers to a region in the spectra of distant quasars that lies between the rest-frame Lyman-β and Lyman-γ emissions. The forest in this region is dominated by a combination of absorption due to resonant Lyα and Lyβ scattering. When considering the 1D Lyβ forest in addition to the 1D Lyα forest, the full statistical description of the data requires four 1D power spectra: Lyα and Lyβ auto-power spectra and the Lyα-Lyβ real and imaginary cross-power spectra. We describe how these can be measured using an optimal quadratic estimator that naturally disentangles Lyα and Lyβ contributions. Using a sample of approximately 60,000 quasar sight-lines from the BOSS Data Release 9, we make the measurement of the one-dimensional power spectrum of fluctuations due to the Lyβ resonant scattering. While we have not corrected our measurements for resolution damping of the power and other systematic effects carefully enough to use them for cosmological constraints, we can robustly conclude the following: i) Lyβ power spectrum and Lyα-Lyβ cross spectra are detected with high statistical significance; ii) the cross-correlation coefficient is ≈ 1 on large scales; iii) the Lyβ measurements are contaminated by the associated OVI absorption, which is analogous to the SiIII contamination of the Lyα forest. Measurements of the Lyβ forest will allow extension of the usable path-length for the Lyα measurements while allowing a better understanding of the physics of intergalactic medium and thus more robust cosmological constraints.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of a Low Activity Beta-Sensitive SR{sup 90} Water Monitor for Fukushima

There are large volumes of contaminated water from the stabilization efforts at the damaged Fukushima Nuclear Power Plants. This water is being processed to remove radioactivity for eventual release to the environment. An on-line continuously operating system to confirm that the clean-up system is working properly, and to provide prompt feedback of the results is required by the system operator. While gamma emitting nuclides allow for the straight forward approach of gamma spectroscopy to identify and quantify radioactivity in water, pure beta emitting nuclides such as Sr{sup 90} pose a challenging problem. The relatively short range of beta radiation in water requires optimization of the measurement geometry in terms of the source-detector distance and source-detector interface while retaining a background sensitivity low enough to meet the Minimum Detectable Concentration (MDC) of 10 Bq/kg in 180 minutes. This issue is complicated by the continuum nature of the beta spectrum which does not allow for simple nuclide identification. The use of the Monte-Carlo code MCNP to estimate system performance before prototyping vastly increases the success of the end product. Various parameters such as detector size and thickness, water chamber size, water chamber construction materials were evaluated to help choose the optimum geometry. The final design was a system consisting of two large-area (16 x 35 cm) and thin (0.15 mm) plastic scintillators placed very close to a sealed a water chamber. The size of the chamber was optimized to obtain the maximum efficiency for the nuclide being measured (Sr/Y{sup 90}) but to minimize the efficiency for possible interferences (Ru/Rh{sup 106}, Cs{sup 137}). A thin carbon fiber window was selected with adequate material and thickness to contain the water under pressure, but also thin enough (0.5 mm) to allow enough beta radiation to pass through to the active detector volume. The entire measurement geometry is then housed in a thick lead shield to reduce contributions from external sources to an acceptable level. Data acquisition is accomplished through customized application-specific software that allows for long counting times to attain a low MDC, but also simultaneously provides alarms on short averaging times to achieve a fast response to sudden changes in activity concentration. Multiple monitors are then linked to supervisory software where real time data and alarms are available for analysis in remote locations. The system also allows for remote operation of the unit; check sources, background checks, systems settings and more may be accessed remotely. Testing of the production devices has shown that we can achieve the 10 Bk/kg MDC requirement for Sr{sup 90} in equilibrium with Y{sup 90} with a count time of approximately 20 minutes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of the Branching Ratio of the charmless decay B s → φφ at CDFII

We present a study of the charmless B s → φφ decay performed with the CDFII detector at the Fermilab Tevatron Collider. Charmless B0 decays currently can be studied only at the Tevatron and represent a field still to be fully explored that offers additional ways to test our present theoretical understanding. The B s → φφ belongs to a particular class of these decays: the B s meson decays into a pair of vector particle and the fi al state is self- conjugate. It can be used to measure the B s decay width difference (ΓΔs), to improve our understanding about the Cabibbo Kobayashi Maskawa matrix, and to perform tests of decay polarization predictions. The B s → φφ decay proceeds through a b → sss transition and in the Standard Model the dominant process is the b → s “penguin” diagram. The same penguin amplitude is involved in several processes which have shown several discrepancies with the Standard Model predictions, raising considerable attention on the theoretical side and new physics interpretations have been considered to explain the experimental data. To shed light on this experimental and theoretical rather complex scenario, new and more precise measurements are clearly needed in as many interesting channels as possible. The study of B s → φφ channel is an important player in this experimental effort. The B s → φφ decay has been observed for the first time by CDF in 2005 [1] in a data sample of 180 pb -1 ; eight events have been seen and a first measurement of the Branching Ratio (BR) has been performed. In this thesis we present an update of this measurement with an integrated luminosity of 2.9fb -1 . An improvement of a factor 5 compared to the previous Branching Ratio measurement is achieved. In Chap.2 a short introduction on the Standard Model with special emphasis on the electroweak sector is presented. In Chap.3 the Fermilab accelerator complex and the CDFII detector is described. The trigger strategy to select events relevant to B physics is explained in some detail. In Chap.4 we present the data sample used for this analysis and some informations concerning the offline reconstruction program. In Chap.5 the Monte Carlo program and its validation procedure are explained. In Chap.6 the strategy of the Branching Ratio measurement and the optimization procedure used to define the analysis selection criteria both for the B s → φφ and the B s → J/ψφ decays are presented. In Chap.7 all the steps needed to perform the measurement of the BR are reported. Signal yields of the B s → φφ and the B s → J/ψφ decays are presented. The trigger and selection efficiencies and the muon efficiency are evaluated. The ratio of the BR(B s → φφ) to the BR(B s → J/ψφ) is measured and is used to compute the Branching Ratio of B s → φφ. The systematic errors on the BR are estimated. In Chap.8 we present the summary of our results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗