Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microwave heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Obscuration of Flare Emission by an Eruptive Prominence

We report on the eclipsing of microwave flare emission by an eruptive prominence from a neighboring region as observed by the Nobeyama Radioheliograph at 17 GHz. The obscuration of the flare emission appears as a dimming feature in the microwave flare light curve. We use the dimming feature to derive the temperature of the prominence and the distribution of heating along the length of the filament. We find that the prominence is heated to a temperature above the quiet Sun temperature at 17 GHz. The duration of the dimming is the time taken by the eruptive prominence in passing over the flaring region. We also find evidence for the obscuration in EUV images obtained by the Solar and Heliospheric Observatory (SOHO) mission.

coronal mass ejections↗

Structure of proton centers and associated nonthermal bursts at microwave frequencies

A very broad band of electromagnetic radiation is emitted during solar flares, especially at the explosive phase. The existence of a large variety of plasmas with various densities and a wide range of temperatures or energies is proposed as the initiating agent. The manner in which the plasmas are heated and accelerated to subrelativistic and relativistic energies is discussed. Observational evidence on the characteristics of active regions which produced proton flares and on the structure of the associated nonthermal microwave bursts of the sun is presented. The behavior of subrelativistic electrons on the sun is described.

Enome, S.↗

Magnetic Microspheres for Therapeutical Applications

Hyperthermia is a well known cancer therapy and consists of heating a tumor region to the elevated temperatures in the range of 40-45 C for an extended period of time (2-8 hours). This leads to thermal inactivation of cell regulatory and growth processes with resulting widespread necrosis, carbonization and coagulation. Moreover, heat boosts the tumor response to other treatments such as radiation, chemotherapy or immunotherapy. Of particular importance is careful control of generated heat in the treated region and keeping it localized. Higher heating, to about 56 C can lead to tissue thermo-ablation. With accurate temperature control, hyperthermia has the advantage of having minimal side effects. Several heating techniques are utilized for this purpose, such as whole body hyperthermia, radio-frequency (RF) hyperthermia, ultrasound technique, inductive microwave antenna hyperthermia, inductive needles (thermoseeds), and magnetic fluid hyperthermia (MFH).MFH offers many advantages as targeting capability by applying magnets. However, this technology still suffers significant inefficiencies due to lack of thermal control. This paper will provide a review of the topic and outline the ongoing work in this area. The main emphasis is in devising ways to overcome the technical difficulty in hyperthermia therapy of achieving a uniform therapeutic temperature over the required region of the body and holding it steady. The basic obstacle of the present heating methods are non-uniform thermal properties of the tissue. Our approach is to develop a novel class of magnetic fluids which have inherent thermoregulating properties. We have identified a few magnetic alloys which can serve as a suitable nano-particle material. The objective is to synthesize, characterize and evaluate the efficacy of TRMF for hyperthermia therapy.

Mazuruk, K.↗

Phase 2: Array automated assembly task low cost silicon solar array project

Several microwave systems for use in solar cell fabrication were developed and experimentally tested. The first system used a standing wave rectangular waveguide horn applicator. Satisfactory results were achieved with this system for impedance matching and wafer surface heating uniformity. The second system utilized a resonant TM sub 011 mode cylindrical cavity but could not be employed due to its poor energy coupling efficiency. The third and fourth microwave systems utilized a circular waveguide operating in the TM sub 01 and TM sub 11 but had problems with impedance matching, efficiency, and field uniformity.

Jones, G. T.↗

Magnetic Microspheres and Tissue Model Studies for Therapeutical Applications

Hyperthermia is a well known cancer therapy and consists of heating a tumor region to the elevated temperatures in the range of 40-45 C for an extended period of time (2-8 hours). This leads to thermal inactivation of cell regulatory and growth processes with resulting widespread necrosis, carbonization and coagulation. Moreover, heat boosts the tumor response to other treatments such as radiation, chemotherapy or immunotherapy. Of particular importance is careful control of generated heat in the treated region and keeping it localized. Higher heating, to about 56 C can lead to tissue thermo-ablation. With accurate temperature control, hyperthermia has the advantage of having minimal side effects. Several heating techniques are utilized for this purpose, such as whole body hyperthermia, radio-frequency (RF) hyperthermia, ultrasound technique, inductive microwave antenna hyperthermia, inductive needles (thermoseeds), and magnetic fluid hyperthermia (MFH).MFH offers many advantages as targeting capability by applying magnets. However, this technology still suffers significant inefficiencies due to lack of thermal control. This paper will provide a review of the topic and outline the ongoing work in this area. The main emphasis is in devising ways to overcome the technical difficulty in hyperthermia breast therapy of achieving a uniform therapeutic temperature over the required region of the body and holding it steady for an extended period (2-3 hours). The basic shortcomings of the presently utilized heating methods stem from the non-uniform thermal properties of the tissue and the point heating characteristics of the techniques without any thermal control. Our approach is to develop a novel class of magnetic fluids, which have inherent thermoregulating properties. We have identified a few magnetic alloys which can serve as suitable nano to micron-size particle material. The objective is to synthesize, characterize and evaluate the efficacy of Thermo Regulating Magnetic Fluids (TRMF) for hyperthermia therapy. The development of a tissue model and testing the fluid dynamics of particle motion, settling, distribution in the tissue matrix and heat generation will be discussed.

Ramachandran, N.↗

A thermal/nonthermal model for solar microwave bursts

A theoretical framework is developed for modeling high-resolution spectra of microwave bursts from the Owens Valley Radio Observatory which can account for departures from expectations based on simple thermal or nonthermal models. Specifically, 80 percent of the events show more than one spectral peak; many bursts have a low-side spectral index steeper than the maximum expected slope; and the peak frequency stays relatively constant and changes intensity in concert with the secondary peaks throughout a given event's solution. It is shown that the observed spectral features can be explained through gyrosynchrotron radiation. The 'secondary' components seen on the LF side of many spectra are nonthermal enhancements superposed upon thermal radiation, occurring between the thermal harmonics. A steep optically thick slope is accounted for by the thermal absorption of nonthermal radiation. If the coexistence of thermal and nonthermal particles is interpreted in terms of electron heating and acceleration in current sheets, a changing electric field strength can account for the gross evolution of the microwave spectra.

Benka, Stephen G.↗

Microwave and Millimeter Wave Nondestructive Evaluation of the Space Shuttle External Tank Insulating Foam

The Space Shuttle Columbia s catastrophic failure has been attributed to a piece of external fuel tank insulating SOFI (Spray On Foam Insulation) foam striking the leading edge of the left wing of the orbiter causing significant damage to some of the protecting heat tiles. The accident emphasizes the growing need to develop effective, robust and life-cycle oriented methods of nondestructive testing and evaluation (NDT&E) of complex conductor-backed insulating foam and protective acreage heat tiles used in the space shuttle fleet and in future multi-launch space vehicles. The insulating SOFI foam is constructed from closed-cell foam. In the microwave regime this foam is in the family of low permittivity and low loss dielectric materials. Near-field microwave and millimeter wave NDT methods were one of the techniques chosen for this purpose. To this end several flat and thick SOFI foam panels, two structurally complex panels similar to the external fuel tank and a "blind" panel were used in this investigation. Several anomalies such as voids and disbonds were embedded in these panels at various locations. The location and properties of the embedded anomalies in the "blind" panel were not disclosed to the investigating team prior to the investigation. Three frequency bands were used in this investigation covering a frequency range of 8-75 GHz. Moreover, the influence of signal polarization was also investigated. Overall the results of this investigation were very promising for detecting the presence of anomalies in different panels covered with relatively thick insulating SOFI foam. Different types of anomalies were detected in foam up to 9 in thick. Many of the anomalies in the more complex panels were also detected. When investigating the blind panel no false positives were detected. Anomalies in between and underneath bolt heads were not easily detected. This paper presents the results of this investigation along with a discussion of the capabilities of the method used.

Shrestha, S.↗

Microwave evidence for large-scale changes associated with a filament eruption

VLA observations at 6 and 20 cm wavelengths taken on August 3, 1985 are presented, showing an eruptive filament event in which microwave emission originated in two widely separated regions during the disintegration of the filament. The amount of heat required for the enhancement is estimated. Near-simultaneous changes in intensity and polarization were observed in the western components of the northern and southern regions. It is suggested that large-scale magnetic interconnections permitted the two regions to respond similarly to an external energy or mass source involved in the disruption of the filament.

Kundu, M. R.↗

High-Temperature Probe Station Developed to Characterize Microwave Devices Through 500 C

A photograph and a block diagram of the high-temperature probe station are shown. The system consists of the ceramic heater mounted on a NASA shuttle tile insulator, a direct current power supply, a personal-computer-based data acquisition and temperature controller, microwave probes, a microscope, and a network analyzer. The ability to perform microwave tests at high temperatures is becoming necessary. There is now a need for sensors and communication circuits that can operate at 500 C and above for aircraft engine development and monitoring during flight. To address this need, researchers have fabricated devices using wide bandgap semiconductors such as SiC with targeted operating temperatures of 500 to 600 C. However, the microwave properties of these devices often change drastically with temperature, so any designs that are intended to be used in such an environment must be characterized at high temperatures. For some reliability, lifetime, and direct-current testing, the device under test can be packaged and characterized in an oven. However, for RF and microwave measurements, it is usually not possible to establish a calibrated reference plane at the device terminals within a package. In addition, the characteristics of the package would vary over a 500 C temperature range, and this would have to be accounted for when the data were analyzed. A high temperature probe station allows circuits and devices to be characterized through on wafer measurements across a broad temperature range with known reference plane. The conventional, commercially available thermal wafer-probe stations that are used to evaluate microwave devices across a controlled temperature range have a typical upper limit of 200 C. Standalone thermal heating chucks are available with an extended upper temperature range of 300 to 400 C. To effectively characterize devices at temperatures up to and surpassing 500 C, Glenn researchers developed a custom probe station. In the past, custom probe stations have been developed to test devices under other extreme environments, such as cryogenic temperatures as low as 37 K. Similarly, this custom probe station was specifically modified for high-temperature use. It allows devices to be measured quickly and flexibly, without the use of wire bonds and test fixtures. The probe station is shown making scattering parameter measurements from 1 to 50 GHz with a Hewlett-Packard 8510C Network Analyzer. There is a half-wafer of silicon directly on top of the heater to provide a uniform heated platform for our sample. A quarter wafer of silicon carbide forms the substrate for our test circuit of several transmission lines.

Downey, Alan N.↗

Methods and apparatus for microwave tissue welding for wound closure

Methods and apparatus for joining biological tissue together are provided. In at least one specific embodiment, a method for joining biological tissue together can include applying a biological solder on a wound. A barrier layer can be disposed on the biological solder. An antenna can be located in proximate spatial relationship to the barrier layer. An impedance of the antenna can be matched to an impedance of the wound. Microwaves from a signal generator can be transmitted through the antenna to weld two or more biological tissue pieces of the wound together. A power of the microwaves can be adjusted by a control circuit disposed between the antenna and the signal generator. The heating profile within the tissue may be adjusted and controlled by the placement of metallic microspheres in or around the wound.

Arndt, G. Dickey↗

Preparation of acid-deficient uranyl nitrate solutions

A solution of acid deficient uranyl nitrate has a formula of UO2(OH)y(NO3)2-y, where y ranges from 0.1 to 0.5. The solution is prepared by placing UxOz in aqueous nitric acid to produce a uranium solution, wherein x is 1 to 3 and z is 2 to 8; placing the uranium solution under a pressure greater than atmospheric pressure in a sealed reaction chamber; and heating the uranium solution to a desired temperature of between 150° C. and 250° C. by applying microwave energy to the uranium solution. The uranium solution is maintained at the desired temperature under a pressure of from 5 atmospheres to 40 atmospheres for a hold time of 15 minutes to 6 hours to produce the desired acid deficient uranyl nitrate.

Brown, Daniel↗

Improvements in the estimates of ice thickness and production in the Chukchi Sea polynyas derived from AMSR-E

For January-March 2003, we use 12.5-km resolution Advanced Microwave Scanning Radiometer (AMSR) data for the first time in a comparison with Synthetic Aperture Radar (SAR) and Special Sensor Microwave/Imager (SSM/I) data to study two Chukchi coast polynyas, one consisting of many, the other of only a few 25-km SSM/I pixels. Within these polynyas, the ice thicknesses are derived separately from the SMM/I 37-GHz and AMSR 36-GHz channels; the heat fluxes are derived by combining thicknesses with meteorological data. Comparison with ScanSAR data shows that for the large polynya, because AMSR provides better resolution of the surrounding coastline and first-year ice, the AMSR heat losses are greater than the SSM/I; for the small polynya, AMSR measures its variability even when its area is order of a single SSM/I pixel. This means that AMSR permits more accurate calculation of polynya heat losses, yielding the potential of improved estimates of Arctic polynya productivity.

ice thicknesses↗

Development of a high power microwave thruster, with a magnetic nozzle, for space applications

This paper describes the current development of a high-power microwave electrothermal thruster (MET) concept at the NASA Lewis Research Center. Such a thruster would be employed in space for applications such as orbit raining, orbit maneuvering, station change, and possibly trans-lunar or trans-planetary propulsion of spacecraft. The MET concept employs low frequency continuous wave (CW) microwave power to create and continuously pump energy into a flowing propellant gas at relative high pressure via a plasma discharge. The propellant is heated to very high bulk temperatures while passing through the plasma discharge region and then is expanded through a throat-nozzle assembly to produce thrust, as in a conventional rocket engine. Apparatus, which is described, is being assembled at NASA Lewis to test the MET concept to CW power levels of 30 kW at a frequency of 915 MHz. The microwave energy is applied in a resonant cavity applicator and is absorbed by a plasma discharge in the flowing propellant. The ignited plasma acts as a lossy load, and with optimal tuning, energy absorption efficiencies over 95 percent (based on the applied microwave power) are expected. Nitrogen, helium, and hydrogen will be tested as propellants in the MET, at discharge chamber pressures to 10 atm.

Power, John L.↗

Microwave Synthetic Routes for Shape-Controlled Catalyst Nanoparticles and Nanocomposites

The use of microwave irradiation for the synthesis of inorganic nanomaterials has recently become a widespread area of research that continues to expand in scope and specialization. The growing demand for nanoscale materials with composition and morphology tailored to specific applications requires the development of facile, repeatable, and scalable synthetic routes that offer a high degree of control over the reaction environment. Microwave irradiation provides unique advantages for developing such routes through its direct interaction with active reaction species, which promotes homogeneous heat distribution, increased reaction rates, greater product quality and yield, and use of mild reaction conditions. Many catalytic nanomaterials such as noble metal nanoparticles and intricate nanocomposites have very limited synthetic routes due to their extreme temperature sensitivity and difficulty achieving homogeneous growth. This work presents recent advances in the use of MW irradiation methods to produce high-quality nanoscale composites with controlled size, morphology, and architecture.

59 BASIC BIOLOGICAL SCIENCES↗

Superconducting Qubits above 20 GHz Operating over 200 mK

Current state-of-the-art superconducting microwave qubits are cooled to extremely low temperatures to avoid sources of decoherence. Higher qubit operating temperatures would significantly increase the cooling power available, which is desirable for scaling up the number of qubits in quantum computing architectures and integrating qubits in experiments requiring increased heat dissipation. To operate superconducting qubits at higher temperatures, it is necessary to address both quasiparticle decoherence (which becomes significant for aluminum junctions above 160 mK) and dephasing from thermal microwave photons (which are problematic above 50 mK). Using low-loss niobium-trilayer junctions, which have reduced sensitivity to quasiparticles due to the higher superconducting transition temperature of niobium, we fabricate transmons with higher frequencies than previously studied, up to 24 GHz. We measure decoherence and dephasing times of about 1 μs, corresponding to average qubit quality factors of approximately 10 5 , and find that decoherence is unaffected by quasiparticles up to 1 K. Without relaxation from quasiparticles, we are able to explore dephasing from purely thermal sources, finding that our qubits can operate up to approximately 250 mK while maintaining similar performance. The thermal resilience of these qubits creates new options for scaling up quantum processors, enables hybrid quantum experiments with high heat-dissipation budgets, and introduces a material platform for even-higher-frequency qubits.

Josephson junctions↗

Two-dimensional thermal modeling of power monolithic microwave integrated circuits (MMIC's)

Numerical simulations of the two-dimensional temperature distributions for a typical GaAs MMIC circuit are conducted, aiming at understanding the heat conduction process of the circuit chip and providing temperature information for device reliability analysis. The method used is to solve the two-dimensional heat conduction equation with a control-volume-based finite difference scheme. In particular, the effects of the power dissipation and the ambient temperature are examined, and the criterion for the worst operating environment is discussed in terms of the allowed highest device junction temperature.

Fan, Mark S.↗

Optimizing the combustion synthesis of FeAlxOy catalysts for microwave-assisted thermocatalytic dehydrogenation of fossil fuels

The growing demand for hydrogen requires the development of clean and energy-efficient technologies for its synthesis. Microwave-assisted thermocatalytic dehydrogenation of fossil fuels has demonstrated the potential to produce H2 with high yield and selectivity, and simultaneously generate valuable nanostructured carbon byproducts. In prior work, iron-based alumina (FeAlxOy) catalysts for this process were made via solution combustion synthesis (SCS). However, the effect of SCS parameters on the dehydrogenation performance is not well understood. The present study investigates this by varying the SCS fuel, Fe:Al molar ratio, and heating mode. The results show subtle changes of these parameters can result in significant differences in the phase composition, specific surface area, and microwave absorbing properties of FeAlxOy, which all affect microwave-assisted dehydrogenation. Notably, H2 selectivity can be increased from 30% to 74%. Statistical testing determined that the SCS fuel used was the most significant SCS parameter affecting dehydrogenation performance.

Chanoi, Zachary A.↗

Endothelium Preserving Microwave Treatment for Atherosclerosis

Method and apparatus are provided to treat atherosclerosis wherein the artery is partially closed by dilating the artery while preserving the vital and sensitive endothelial layer thereof Microwave energy having a frequency from 3 GHz to 300 GHz is propagated into the arterial wall to produce a desired temperature profile therein at tissue depths sufficient for thermally necrosing connective tissue and softening fatty and waxy plaque while limiting heating of surrounding tissues including the endothelial laser and/or other healthy tissue, organs, and blood. The heating period for raising the temperature a potentially desired amount, about 20 C., within the atherosclerotic lesion may be less than about one second. In one embodiment of the invention, a radically beveled waveguide antenna is used to deliver microwave energy at frequencies from 25 GHz or 30 GHz to about 300 GHz and is focused towards a particular radial sector of the artery. Because the atherosclerotic lesions are often asymmetrically disposed, directable of focussed heating preserves healthy sectors of the artery and applies energy to the asymmetrically positioned lesion faster than a non-directed beam. A computer simulation predicts isothermic temperature profiles for the given conditions and man be used in selecting power, pulse duration, beam width, and frequency of operation to maximize energy deposition and control heat rise within the atherosclerotic lesion without harming healthy tissues or the sensitive endothelium cells.

Carl, James R.↗