Search NASA⌕ Search

SEARCH · Search NASA

Results for “Model Counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Improved Time-Stepping Methods in Global to Regional Ocean Modeling

Improvements in time-stepping schemes can provide substantial improvements in the throughput of global ocean-climate models, but is challenging due to large variations in time scales in the dynamics and spatial scales in the global, variable resolution mesh. Two funded projects aim to speed up the Model for Prediction Across Scales-Ocean (MPAS-Ocean). The first will add a variable-timestepping formulation to MPAS-Ocean, which is a critical step towards running efficiently on global variable-resolution meshes with regional and coastal refinement. The second optimizes the barotropic (depth-integrated) mode, which is currently a performance bottleneck at high core counts. The proposed compute time will be used for extensive model validation and parameter studies for both methods.

54 ENVIRONMENTAL SCIENCES↗

Cosmic shear cosmology beyond two-point statistics: a combined peak count and correlation function analysis of DES-Y1

ABSTRACT We constrain cosmological parameters from a joint cosmic shear analysis of peak-counts and the two-point shear correlation functions, as measured from the Dark Energy Survey (DES-Y1). We find the structure growth parameter $S_8\equiv \sigma _8\sqrt{\Omega _{\rm m}/0.3} = 0.766^{+0.033}_{-0.038}$ which, at 4.8 per cent precision, provides one of the tightest constraints on S8 from the DES-Y1 weak lensing data. In our simulation-based method we determine the expected DES-Y1 peak-count signal for a range of cosmologies sampled in four w cold dark matter parameters (Ωm, σ8, h, w0). We also determine the joint covariance matrix with over 1000 realizations at our fiducial cosmology. With mock DES-Y1 data we calibrate the impact of photometric redshift and shear calibration uncertainty on the peak-count, marginalizing over these uncertainties in our cosmological analysis. Using dedicated training samples we show that our measurements are unaffected by mass resolution limits in the simulation, and that our constraints are robust against uncertainty in the effect of baryon feedback. Accurate modelling for the impact of intrinsic alignments on the tomographic peak-count remains a challenge, currently limiting our exploitation of cross-correlated peak counts between high and low redshift bins. We demonstrate that once calibrated, a fully tomographic joint peak-count and correlation functions analysis has the potential to reach a 3 per cent precision on S8 for DES-Y1. Our methodology can be adopted to model any statistic that is sensitive to the non-Gaussian information encoded in the shear field. In order to accelerate the development of these beyond-two-point cosmic shear studies, our simulations are made available to the community upon request.

Harnois-Déraps, Joachim↗

Comprehensive Physical Activity Assessment During U.S. Army Basic Combat Training

Abstract Alemany, JA, Pierce, JR, Bornstein, DB, Grier, TL, Jones, BH, and Glover, SH. Comprehensive physical activity assessment during U.S. Army Basic Combat Training. J Strength Cond Res 36(12): 3505–3512, 2022—Physical activity (PA) volume, intensity, and qualitative contextual information regarding activity type and loads carried are limited during U.S. Army Basic Combat Training (BCT). The purpose of this study was to characterize daily (05:00–20:00 hours) PA during BCT using a comprehensive approach. During 2 10-week BCT cycles ( n = 40 trainees per cycle), pedometers, accelerometers, and direct observation were used to estimate daily step count, PA volume, and intensity. Physical activity intensity was categorized by metabolic equivalents (METs) such as “sedentary” (1–2 METs), “light” (2–3 METs), “moderate” (3–6 METs), or “vigorous” (≥6 METs). Daily PA data were analyzed longitudinally using linear mixed models, with significance set at p ≤ 0.05. The mean daily step count was 13,459 ± 4,376 steps, and the mean daily accelerometer-assessed PA volume and intensity were as follows: sedentary: 505 ± 98 minutes, light: 190 ± 78 minutes, moderate: 168 ± 51 minutes, and vigorous: 14 ± 14 minutes, with no differences between cycles for all measures ( p > 0.50). Cumulative time on feet (∼50%) and sitting (20–25%) accounted for most daily activity types during both cycles. Trainees, on average, carried between 3 and 9 kg, and ≥9 kg, for 60% and 10% of the monitored day, respectively. Basic Combat Training's physical demands are high, where trainees achieved 1.7 to 2.7 times greater daily ambulation and 6 times the recommended weekly moderate-to-vigorous PA compared with civilian counterparts and performed weight-bearing load carriage for nearly half of the day. Basic Combat Training-associated PA may increase injury risk among trainees unaccustomed to arduous PA and exercise. Implementing national PA policies to improve physical fitness and facilitate acclimatization to BCT's high physical demands could reduce public health burdens and military nonreadiness.

Sport Sciences↗

Sensitivity analysis towards trace-uranium detection with γ-γ coincidence NAA

An improved approach for detection of trace amounts of 238 U by means of neutron activation analysis (NAA) is presented. The analysis enhancement is obtained by utilizing γ-γ coincidence counting. An empirical method for evaluating the sensitivity gain in the presence of a large source-related background is presented. A comparison of detection limits is made between two counting schemes; namely, counting single gammas using one HPGe detector versus counting coincident gammas using two HPGe detectors placed face-to-face. Furthermore, a data-validated radiation transport model, created in GEANT4 for a single HPGe detector, is extended to handle the two detector setup. In this counting scheme, a 238 U-detection sensitivity enhancement of about a factor of 8 is predicted for a sample of Saint-Gobain G3 Sapphire when compared to the simpler singles counting approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy-saving potential evaluation for primary schools with occupant-centric controls

Recent studies demonstrated that there is significant energy-saving potential for primary schools, which heating, ventilation, and air-conditioning (HVAC) systems with occupant-centric control (OCC) is an excellent candidate to save energy. However, such an energy impact has yet to be evaluated for different climate zones as well as different energy code versions, but is critical for technology transfer and deployment. Therefore, this paper conducts comprehensive evaluation on the energy-saving potentials for the primary schools with two advanced OCC strategies: presence-based and counting-based. In this work, ninety-six building energy models with stochastic behavior of occupants are developed and simulated, which consist of two building energy code versions, 16 climate zones, and baseline case (without OCC) and two advanced cases (with OCC). To evaluate the energy saving potentials for OCC, primary schools in the U.S. are used as an example. The results show that there is significant energy-saving potential for primary schools by considering OCC strategies, especially the counting-based case. The energy-saving potential is up to 10.2% for presence-based OCC and 12.41% for counting-based OCC. Furthermore, both climate and code version have a significant impact on energy savings from OCC strategies. The energy-saving potentials vary from 1.79% to 12.41% for different climates and code versions. This evaluation can also contribute to quantify the nationwide energy saving potential for other countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-E-I-88: The Effect of System Dead Time On Real-Time Plastic and GOS Based Fiber-Optic Dosimetry Systems

Purpose: A methodology is presented to correct for measurement inaccuracies at high detector count rates using a plastic and GOS scintillation fibers coupled to a photomultiplier tube with digital readout. This system allows temporal acquisition and manipulation of measured data. Methods: The detection system used was a plastic scintillator and a separate gadolinium scintillator, both (0.5 diameter) coupled to an optical fiber with a Hamamatsu photon counter with a built-in microcontroller and digital interface. Count rate performance of the system was evaluated using the nonparalzable detector model. Detector response was investigated across multiple radiation sources including: orthovoltage x-ray system, colbat-60 gamma rays, proton therapy beam, and a diagnostic radiography x-ray tube. The dead time parameter was calculated by measuring the count rate of the system at different exposure rates using a reference detector. Results: The system dead time was evaluated for the following sources of radiation used clinically: diagnostic energy x-rays, cobalt-60 gamma rays, orthovoltage xrays, particle proton accelerator, and megavoltage x-rays. It was found that dead time increased significantly when exposing the detector to sources capable of generating Cerenkov radiation, all of the sources sans the diagnostic x-rays, with increasing prominence at higher photon energies. Percent depth dose curves generated by a dedicated ionization chamber and compared to the detection system demonstrated that correcting for dead time improves accuracy. On most sources, nonparalzable model fit provided an improved system response. Conclusion: Overall, the system dead time was variable across the investigated radiation particles and energies. It was demonstrated that the system response accuracy was greatly improved by correcting for dead time effects. Cerenkov radiation plays a significant role in the increase in the system dead time through transient absorption effects attributed to electron hole-pair creations within the optical waveguide.

07 ISOTOPE AND RADIATION SOURCES↗

Flagella-Mediated Differences in Deposition Dynamics for Azotobacter vinelandii in Porous Media

A multi-scale approach was designed to investigate deposition of flagellated and non-flagellated strains of Azotobacter vinelandii in porous media. In a radial stagnation point flow cell (RSPF), the deposition rate of the flagellated strain (DJ77) on quartz was higher than that of the non-flagellated (Fla-) strain. In contrast, deposition of the Fla- strain exceeded that of DJ77 in two-dimensional silicon microfluidic models (micromodels) and in columns packed with glass beads. Direct cell counts in micromodel experiments showed decreasing values of clean collector removal efficiencies over time, suggesting that approaching cells were blocked from deposition by cells already attached to the collector surface. Column breakthrough curves for both strains also showed a decrease in deposition rates with time. Modeling results showed that blocking becomes effective for DJ77 strain at lower ionic strengths (1mM and 10mM), while for Fla- strain blocking was similar at all ionic strengths. In later stages of micromodel experiments, a ripening effect was also observed, where cells preferentially attached to already attached cells. Ripening happened earlier with the Fla- strain, which suggested that flagella interfered with ripening. Different mechanisms dominate at different stages of bacteria transport in porous media.

bacteria transport, porous media, flagella, microm↗

Verification of Special Nuclear Material (SNM) using Active Well Coincidence Counter (AWCC) and a High Purity Germanium (HPGe) Detector

SNM verification can be accomplished via two methods i.e. destructive analysis (DA) or nondestructive analysis (NDA). The DA modes are much more accurate compared to NDA modes; nevertheless, the sample's physical integrity is destroyed in the process. Techniques such as ICP-MS, ID-ICP-MS, TI-MS are few examples of DA, where a bulk material is ground and mixed with a solution (some form of acid) to acquire a homogenous sample. In contrast, NDA modes utilize signals emitted by the sample such as gamma, neutrons, light, or heat to analyze samples under investigation. HPGe detectors are some of the most frequently used gamma detectors to assay SNM. However, in a high activity scenario it provides a large uncertainty and sometimes becomes unfeasible to measure low energy gamma rays. Meanwhile, neutron detectors are not affected by the gamma background, therefore they can be used in addition to the gamma detectors to verify total fissile mass ({sup 235}U + {sup 239}Pu) of SNM. The AWCC is one of the thermal neutron NDA systems developed at the Los Alamos National Laboratory (LANL). It consists of 42 {sup 3}He detectors to measure gross neutrons (singles), coincidence neutrons (doubles), higher order multiplicity counting (triples, quadruples, etc.). It can effectively operate in both active and passive neutron interrogation modes. It can utilize AmLi, AmBe, or {sup 252}Cf active interrogation neutron sources. It is used to verify declared fissile mass ({sup 235}U or {sup 239}Pu) present in SNM. Objectives: Calibrate HPGe and AWCC for lightly irradiated (with enough {sup 137}Cs gamma background) ∼93% enriched HEU fuels; Verify fissile mass ({sup 235}U +{sup 239}Pu) content using AWCC and HPGe; Model and benchmark AWCC in MCNP6. Neutron coincidence and multiplicity counting: Two or more neutrons are coincident if they are detected by the system within the specified gate window; In AWCC: Gate window is 128 μsec; Induced fission in fissile material such as {sup 235}U and {sup 239}Pu - emission of time correlated neutrons - Singles, Doubles, Triples, or Quadruples; No induced fission in non-fissile materials- no correlated neutrons - only singles. SNM can be verified with high accuracy and precision using gamma and neutron NDA instruments such as HPGe and AWCC. Interaction with thermal neutrons. Non-fissile atoms - do not emit correlated neutrons. Fissile atoms - emit correlated neutrons during induced fission events. The time correlated neutrons can be detected by using coincidence or multiplicity counters such as AWCC. Likewise, {sup 235}U produces 186 keV gamma peak that can be measured by a HPGe gamma detector. Counts under 186 keV gamma peak provide information about {sup 235}U content. Combining AWCC and HPGe results can provide better understanding of special nuclear material under investigation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neutron Multiplicity Counting Moments for Fissile Mass Estimation in Scatter-Based Neutron Detection Systems

Neutron multiplicity counting (NMC) techniques are widely used for nuclear materials accountability and international safeguards applications to quantitatively evaluate characteristic properties pertaining to fissile material. Mathematical models for NMC moments have been previously derived for systems that use capture-based detectors; however, these models are not applicable when scatter-based detectors are used because of “neutron cross talk.” Neutron cross talk occurs when a single neutron scatters and deposits energy above threshold into multiple detectors causing spurious increase in multiplicity counts; this, in turn, has caused fissile mass to be overestimated when not treated. In this paper, we propose new mathematical models derived from point kinetics to correct for neutron cross-talk effects up to any arbitrary order N, where N denotes the maximum number of counts a single neutron can cause. The new models were used to estimate the fissile mass of plutonium metal and oxide samples with effective 240 Pu mass ranging from 2.5 to 250 g. The adequacy of the models was confirmed using simulations of a conceptual scatter-based neutron multiplicity counter (e.g., organic scintillators) using MCNPX v2.7e with the PoliMi fission event generating extension. The fissile mass estimates with no correction for neutron cross-talk events yielded an average relative deviation from the true 240 Pu eff mass of 55.94% and 84.56% for metal and oxide samples, respectively. When neutron cross-talk events of order N = 2 are included in the model, the fissile mass estimates yielded an average relative deviation of 11.89% for metal and 13.21% for oxide samples. Accounting for neutron cross-talk events of order N = 3 resulted in fissile mass estimates with an average relative deviation of 9.58% and 10.51% for metal and oxide samples, respectively. These mass estimates were compared to a reference case (i.e., no neutron crosstalk effects) that yielded an average relative deviation of 6.81% and 4.77% for metal and oxide samples, respectively. In conclusion, the discrepancy between the estimates from the proposed model and the reference case is attributed to the assumed value of N, which sets a finite upper bound on the order of cross-talk events the model treats (i.e., the model for N = 3 assumes that a neutron will never cause more than three counts).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE NORTHERN WRAPS OF THE SAGITTARIUS STREAM AS TRACED BY RED CLUMP STARS: DISTANCES, INTRINSIC WIDTHS, AND STELLAR DENSITIES

We trace the tidal Stream of the Sagittarius dwarf spheroidal galaxy (Sgr dSph) using Red Clump (RC) stars from the catalog of the Sloan Digital Sky Survey-Data Release 6, in the range 150{sup 0} {approx}< R.A. {approx}< 220{sup 0}, corresponding to the range of orbital azimuth 220{sup 0} {approx}< {Lambda} {approx}< 290{sup 0}. Substructures along the line of sight (los) are identified as significant peaks in the differential star count profiles (SCPs) of candidate RC stars. A proper modeling of the SCPs allows us to obtain (1) {<=}10% accurate, purely differential distances with respect to the main body of Sgr, (2) estimates of the FWHM along the los, and (3) estimates of the local density, for each detected substructure. In the range 255{sup 0} {approx}< {Lambda} {approx}< 290{sup 0} we cleanly and continuously trace various coherent structures that can be ascribed to the Stream, in particular: the well-known northern portion of the leading arm, running from d {approx_equal} 43 kpc at {Lambda} {approx_equal} 290{sup 0} to d {approx_equal} 30 kpc at {Lambda} {approx_equal} 255{sup 0}, and a more nearby coherent series of detections lying at a constant distance d {approx_equal} 25 kpc, that can be identified with a wrap of the trailing arm. The latter structure, predicted by several models of the disruption of Sgr dSph, was never traced before; comparison with existing models indicates that the difference in distance between these portions of the leading and trailing arms may provide a powerful tool to discriminate between theoretical models assuming different shapes of the Galactic potential. A further, more distant wrap in the same portion of the sky is detected only along a couple of los. For {Lambda} {approx}< 255{sup 0} the detected structures are more complex and less easily interpreted. We are confident of being able to trace the continuation of the leading arm down to {Lambda} {approx_equal} 220{sup 0} and d {approx_equal} 20 kpc; the trailing arm is seen up to {Lambda} {approx_equal} 240{sup 0} where it is replaced by more distant structures. Possible detections of more nearby wraps and of the Virgo Stellar Stream are also discussed. These measured properties provide a coherent set of observational constraints for the next generation of theoretical models of the disruption of Sgr.

79 ASTRONOMY AND ASTROPHYSICS↗

INFORMATION ON THE MILKY WAY FROM THE TWO MICRON ALL SKY SURVEY WHOLE SKY STAR COUNT: THE STRUCTURE PARAMETERS

The K{sub s} -band differential star count of the Two Micron All Sky Survey (2MASS) is used to derive the global structure parameters of the smooth components of the Milky Way. To avoid complication introduced by other fine structures and significant extinction near and at the Galactic plane, we only consider Galactic latitude |b| > 30{sup 0} data. The star count data are fitted with a three-component model: double exponential thin disk and thick disk, and a power-law decay oblate halo. Using maximum likelihood, the best-fit local density of the thin disk is n{sub 0} = 0.030 {+-} 0.002 stars pc{sup -3}. The best-fit scale height and length of the thin disk are H{sub z1} = 360 {+-} 10 pc and H{sub r1} = 3.7 {+-} 1.0 kpc, and those of the thick disk are H{sub z2} = 1020 {+-} 30 pc and H{sub r2} = 5.0 {+-} 1.0 kpc, the local thick-to-thin disk density ratio is f{sub 2} = 7% {+-} 1%. The best-fit axis ratio, power-law index, and local density ratio of the oblate halo are {kappa} = 0.55 {+-} 0.15, p = 2.6 {+-} 0.6, and f{sub h} = 0.20% {+-} 0.10%, respectively. Moreover, we find some degeneracy among the key parameters (e.g., n{sub 0}, H{sub z1}, f{sub 2}, and H{sub z2}). Any pair of these parameters are anti-correlated to each other. The 2MASS data can be well fitted by several possible combinations of these parameters. This is probably the reason why there is a wide range of values for the structure parameters in literature similar to this study. Since only medium and high Galactic latitude data are analyzed, the fitting is insensitive to the scale lengths of the disks.

79 ASTRONOMY AND ASTROPHYSICS↗

The WFPC2 ultraviolet survey: The blue straggler population in NGC 5824

We have used a combination of high-resolution Hubble Space Telescope Wide Field Planetary Camera 2 and wide-field ground-based observations, in ultraviolet and optical bands, to study the blue straggler star population of the massive outer halo globular cluster NGC 5824 over its entire radial extent. We have computed the center of the cluster and constructed the radial density profile from detailed star counts. The profile is well reproduced by a Wilson model with a small core (r{sub c} ≅ 4.''4) and a concentration parameter c ≅ 2.74. We also present the first age determination for this cluster. From a comparison with isochrones, we find t = 13 ± 0.5 Gyr. We discuss this result in the context of the observed age-metallicity relation of Galactic globular clusters. A total of 60 bright blue stragglers has been identified. Their radial distribution is found to be bimodal, with a central peak, a well-defined minimum at r ∼ 20'', and an upturn at large radii. In the framework of the dynamical clock recently defined by Ferraro et al., this feature suggests that NGC 5824 is a cluster of intermediate dynamical age.

79 ASTRONOMY AND ASTROPHYSICS↗

A Spitzer survey of Deep Drilling Fields to be targeted by the Vera C. Rubin Observatory Legacy Survey of Space and Time

The Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) will observe several Deep Drilling Fields (DDFs) to a greater depth and with a more rapid cadence than the main survey. In this paper, we describe the ‘DeepDrill’ survey, which used the Spitzer Space Telescope Infrared Array Camera (IRAC) to observe three of the four currently defined DDFs in two bands, centred on 3.6 and 4.5 μm. Furthermore, these observations expand the area that was covered by an earlier set of observations in these three fields by the Spitzer Extragalactic Representative Volume Survey (SERVS). The combined DeepDrill and SERVS data cover the footprints of the LSST DDFs in the Extended Chandra Deep Field–South (ECDFS) field, the ELAIS-S1 field (ES1), and the XMM-Large-Scale Structure Survey field (XMM-LSS). The observations reach an approximate 5σ point-source depth of 2 μJy (corresponding to an AB magnitude of 23.1; sufficient to detect a 10$^{11} \, \mathrm{M}_{\odot}$ galaxy out to z ≈ 5) in each of the two bands over a total area of $\approx 29\,$ deg2. The dual-band catalogues contain a total of 2.35 million sources. In this paper, we describe the observations and data products from the survey, and an overview of the properties of galaxies in the survey. We compare the source counts to predictions from the Shark semi-analytic model of galaxy formation. We also identify a population of sources with extremely red ([3.6]-[4.5] >1.2) colours which we show mostly consists of highly obscured active galactic nuclei.

79 ASTRONOMY AND ASTROPHYSICS↗

Self-calibrating optical galaxy cluster selection bias using cluster, galaxy, and shear cross-correlations

ABSTRACT The clustering signals of galaxy clusters are powerful tools for self-calibrating the mass–observable relation and are complementary to cluster abundance and lensing. In this work, we explore the possibility of combining three correlation functions – cluster lensing, the cluster–galaxy cross-correlation function, and the galaxy autocorrelation function – to self-calibrate optical cluster selection bias, the boosted clustering and lensing signals in a richness-selected sample mainly caused by projection effects. We develop mock catalogues of redMaGiC-like galaxies and redMaPPer-like clusters by applying halo occupation distribution models to N-body simulations and using counts-in-cylinders around massive haloes as a richness proxy. In addition to the previously known small-scale boost in projected correlation functions, we find that the projection effects also significantly boost three-dimensional correlation functions to scales of 100 $h^{-1} \, \rm Mpc$. We perform a likelihood analysis assuming survey conditions similar to the Dark Energy Survey and show that the selection bias can be self-consistently constrained at the 10 per cent level. We discuss strategies for applying this approach to real data. We expect that expanding the analysis to smaller scales and using deeper lensing data would further improve the constraints on cluster selection bias.

Astronomy & Astrophysics↗

Beta function in the non-Abelian Nambu-Jona-Lasinio model in four dimensions

In this paper we present the structure of the renormalization group in non-Abelian Nambu-Jona-Lasinio model up to 1-loop order. The model is not perturbatively renormalizable in the usual power counting sense, but it is treated as an effective theory, valid in a scale of energy in which p<<{lambda}, where p is the external momenta of the loop and {lambda} is a massive parameter that characterizes the couplings of the nonrenormalizable vertex. We clarify the tensorial structure of the interaction vertices and calculate the functions of the renormalization group. The analysis of the fixed points of the theory is also presented using Zimmermann's procedure for reducing the coupling constants. We find that the origin is an infrared-stable fixed point at low energies and also there is a nontrivial ultraviolet stable fixed point, indicating that the theory could be perturbatively investigated in the low momentum regime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hybrid Quantum-Classical Neural Networks

Deep learning is one of the most successful and far-reaching strategies used in machine learning today. However, the scale and utility of neural networks is still greatly limited by the current hardware used to train them. These concerns have become increasingly pressing as conventional computers are soon expected to approach the physical limitations that will slow their performance improvements in the near future. For these reasons, scientists have begun to explore alternative computing platforms, like quantum computers, for training neural networks. In recent years, variational quantum circuits have emerged as one of the most successful approaches to quantum deep learning on noisy intermediate scale quantum devices. We propose a hybrid quantum-classical neural network architecture where each neuron is a variational quantum circuit. We empirically analyze the performance of this hybrid neural network on a series of binary classification data sets using a simulated IBM universal quantum computer and a state-of-the-art IBM universal quantum computer. On the simulated hardware, we observe that the hybrid neural network achieves around 10% higher classification accuracy and 20% better minimization of the cost function than an individual variational quantum circuit. On the quantum hardware, we observe that each model only performs well when the qubit and gate count is sufficiently small.

Arthur, Davis↗

AMAROK: A Radio Frequency Development Platform for High-Power, Full-Scale Positive Ion Sources for DIII-D Neutral Beam Injectors

Next-generation neutral beam injection (NBI) systems demand RF ion sources capable of efficiently coupling >120 kW at 2–4-MHz frequencies, yet existing designs face voltage standoff and impedance-matching challenges. To address this, the advanced multicoil antenna for RF operations at kilowatts (AMAROK) was developed as a high-power RF inductively coupled plasma (ICP) source delivering up to 200 kW in the 2–4-MHz range via four phase-controlled generators for flexible power sharing. Two antenna designs—a single-strap multiturn (MT) and a multistrap single-turn (ST) design—were evaluated to optimize resonance, impedance matching, and power coupling across plasma loads. Here, a semi-analytical self-resonant frequency (SRF) model, validated experimentally, predicts resonance trends for arbitrary turn counts and tubing diameters, enabling rapid antenna optimization. Strap-to-strap mutual inductance in the ST configuration showed strong spatial dependence, guiding generator operation and total load inductance. These insights informed a custom π -topology matching network, achieving stable impedance matching over a wide range of plasma-driven loads. Collectively, these results position AMAROK as a versatile testbed for advancing high-power RF source technology in fusion NBI applications.

DIII-D↗

Safeguards Technology Development Program 1st Quarter FY 2018 Report

LLNL will evaluate the performance of a stilbene-based scintillation detector array for IAEA neutron multiplicity counting (NMC) applications. This effort will combine newly developed modeling methodologies and recently acquired high-efficiency stilbene detector units to quantitatively compare the prototype system performance with the conventional He-3 counters and liquid scintillator alternatives.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗