Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Direct simulation Monte Carlo technique for modeling of the environment in the vicinity of the Space Shuttle Orbiter

A program for analyzing the flowfield parameters in the neighborhood of the Space Shuttle Orbiter has been developed. The program uses the direct simulation Monte Carlo method, which is a completely probabilistic Monte Carlo technique capable of analyzing 3-dimensional steady or unsteady flow with prescribed internal and external boundary conditions. The freestream flux densities incident on the external flowfield boundaries are calculated from the drifting Maxwellian gas properties of the freestream. The flux entering the flowfield from the internal boundary is calculated from the outgassing flux density distribution over the Shuttle external surface and the prescribed discrete source fluxes. This technique produces a numerical flowfield solution which is the probabilistic equivalent of a complete solution of the time-dependent, 3-dimensional Boltzmann equation. Flowfield results are presented for the following configurations: (1) Shuttle angles of attack of 0 and 90 deg, (2) freestream density 10 to the 9th - 10 to the 11th per cu cm, (3) Shuttle outgassing flux density, and (4) operation of the aft downfiring vernier Reaction Control System (RCS) engine. Results are presented for column density distribution of outgassed and engine species and for the flux density of outgassed and engine species incident on the Shuttle bay and the windshield.

Melfi, L. T., Jr.↗

Three-dimensional Monte Carlo simulation of gamma-ray scattering and production in the atmosphere

Results are reported from Monte Carlo numerical simulations of atmospheric gamma-ray scattering and production. The basic physical principles involved in the construction of the models are reviewed, and results are presented in extensive graphs for low-energy gamma rays with the spectra of gamma-ray bursts, solar flares, the Crab pulsar, and 511-keV line radiation. It is shown that the model accurately reproduces the characteristics of atmospheric albedo radiation, including details of the angular distribution. The potential applicability of the Monte Carlo technique to studies of the near-earth radiation environment is indicated.

Morris, Daniel J.↗

Study of the effective point of measurement for ion chambers in electron beams by Monte Carlo simulation

In current dosimetry protocols for electron beams, for plane-parallel chambers, the effective point of measurement is at the front face of the cavity, and, for cylindrical chambers, it is at a point shifted 0.5r upstream from the cavity center. In this study, Monte Carlo simulations are employed to study the issue of effective point of measurement for both plane-parallel chambers and cylindrical thimble chambers in electron beams. It is found that there are two ways of determining the position of the effective point of measurement: One is to match the calculated depth-ionization curve obtained from a modeled chamber to a calculated depth-dose curve; the other is to match the electron fluence spectrum in the chamber cavity to that in the phantom. For plane-parallel chambers, the effective point of measurement determined by the first method is generally not at the front face of the chamber cavity, which is obtained by the second method, but shifted downstream toward the cavity center by an amount that could be larger than one-half a millimeter. This should not be ignored when measuring depth-dose curves in electron beams. For cylindrical chambers, these two methods also give different positions of the effective point of measurement: The first gives a shift of 0.5r, which is in agreement with measurements for high-energy beams and is the same as the value currently used in major dosimetry protocols; the latter gives a shift of 0.8r, which is closer to the value predicted by a theoretical calculation assuming no-scatter conditions. The results also show that the shift of 0.8r is more appropriate if the cylindrical chamber is to be considered as a Spencer-Attix cavity. In electron beams, since the water/air stopping-power ratio changes with depth in a water phantom, the difference of the two shifts (0.3r) will lead to an incorrect evaluation of the water/air stopping-power ratio at the point of measurement, thus resulting in a systematic error in determining the absorbed dose by cylindrical chambers. It is suggested that a shift of 0.8r be used for electron beam calibrations with cylindrical chambers and a shift of 0.4r-0.5r be used for depth-dose measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-84: Measurement and Monte-Carlo Simulation of Electron Phase Spaces Using a Wide Angle Magnetic Electron Spectrometer

Purpose: To measure and simulate well-defined electron spectra using a linear accelerator and a permanent-magnetic wide-angle spectrometer to test the performance of a novel reconstruction algorithm for retrieval of unknown electron-sources, in view of application to diagnostics of laser-driven particle acceleration. Methods: Six electron energies (6, 9, 12, 15, 18 and 21 MeV, 40cm × 40cm field-size) delivered by a Siemens Oncor linear accelerator were recorded using a permanent-magnetic wide-angle electron spectrometer (150mT) with a one dimensional slit (0.2mm × 5cm). Two dimensional maps representing beam-energy and entrance-position along the slit were measured using different scintillating screens, read by an online CMOS detector of high resolution (0.048mm × 0.048mm pixels) and large field of view (5cm × 10cm). Measured energy-slit position maps were compared to forward FLUKA simulations of electron transport through the spectrometer, starting from IAEA phase-spaces of the accelerator. The latter ones were validated against measured depth-dose and lateral profiles in water. Agreement of forward simulation and measurement was quantified in terms of position and shape of the signal distribution on the detector. Results: Measured depth-dose distributions and lateral profiles in the water phantom showed good agreement with forward simulations of IAEA phase-spaces, thus supporting usage of this simulation source in the study. Measured energy-slit position maps and those obtained by forward Monte-Carlo simulations showed satisfactory agreement in shape and position. Conclusion: Well-defined electron beams of known energy and shape will provide an ideal scenario to study the performance of a novel reconstruction algorithm using measured and simulated signal. Future work will increase the stability and convergence of the reconstruction-algorithm for unknown electron sources, towards final application to the electrons which drive the interaction of TW-class laser pulses with nanometer thin target foils to accelerate protons and ions to multi-MeV kinetic energy. Cluster of Excellence of the German Research Foundation (DFG) “Munich-Centre for Advanced Photonics”.

07 ISOTOPE AND RADIATION SOURCES↗

Validation of Monte Carlo simulation of neutron production in a spallation experiment

A renewed interest in experimental research on Accelerator-Driven Systems (ADS) has been initiated by the global attempt to produce energy from thorium as a safe(r), clean(er) and (more) proliferation-resistant alternative to the uranium-fuelled thermal nuclear reactors. The ADS research has been actively pursued at the Joint Institute for Nuclear Research (JINR), Dubna, since decades. Most recently, the emission of fast neutrons was experimentally investigated at the massive (m = 512 kg) natural uranium spallation target QUINTA. The target has been irradiated with the relativistic deuteron beams of energy from 0.5 AGeV up to 4 AGeV at the JINR Nuclotron accelerator in numerous experiments since 2011. Neutron production inside the target was studied through the gamma-ray spectrometry measurement of natural uranium activation detectors. Experimental reaction rates for (n,γ), (n,f) and (n,2n) reactions in uranium have provided valuable information about the neutron distribution over a wide range of energies up to some GeV. The experimental data were compared to the predictions of Monte Carlo simulations using the MCNPX 2.7.0 code. In conclusion, the results are presented and potential sources of partial disagreement are discussed later in this work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo simulation of energy deposition by low-energy electrons in molecular hydrogen

A set of detailed atomic cross sections has been used to obtain the spatial deposition of energy by 1-20-eV electrons in molecular hydrogen by a Monte Carlo simulation of the actual trajectories. The energy deposition curve (energy per distance traversed) is quite peaked in the forward direction about the entry point for electrons with energies above the threshold of the electronic states, but the peak decreases and broadens noticeably as the electron energy decreases below 10 eV (threshold for the lowest excitable electronic state of H2). The curve also assumes a very symmetrical shape for energies below 10 eV, indicating the increasing importance of elastic collisions in determining the shape of the curve, although not the mode of energy deposition.

Heaps, M. G.↗

Application of proton boron fusion reaction to radiation therapy: A Monte Carlo simulation study

Three alpha particles are emitted from the point of reaction between a proton and boron. The alpha particles are effective in inducing the death of a tumor cell. After boron is accumulated in the tumor region, the emitted from outside the body proton can react with the boron in the tumor region. An increase of the proton's maximum dose level is caused by the boron and only the tumor cell is damaged more critically. In addition, a prompt gamma ray is emitted from the proton boron reaction point. Here, we show that the effectiveness of the proton boron fusion therapy was verified using Monte Carlo simulations. We found that a dramatic increase by more than half of the proton's maximum dose level was induced by the boron in the tumor region. This increase occurred only when the proton's maximum dose point was located within the boron uptake region. In addition, the 719 keV prompt gamma ray peak produced by the proton boron fusion reaction was positively detected. This therapy method features the advantages such as the application of Bragg-peak to the therapy, the accurate targeting of tumor, improved therapy effects, and the monitoring of the therapy region during treatment.

07 ISOTOPE AND RADIATION SOURCES↗

Monte Carlo simulation of PET and SPECT imaging of {sup 90}Y

Purpose: Yittrium-90 ({sup 90}Y) is traditionally thought of as a pure beta emitter, and is used in targeted radionuclide therapy, with imaging performed using bremsstrahlung single-photon emission computed tomography (SPECT). However, because {sup 90}Y also emits positrons through internal pair production with a very small branching ratio, positron emission tomography (PET) imaging is also available. Because of the insufficient image quality of {sup 90}Y bremsstrahlung SPECT, PET imaging has been suggested as an alternative. In this paper, the authors present the Monte Carlo-based simulation–reconstruction framework for {sup 90}Y to comprehensively analyze the PET and SPECT imaging techniques and to quantitatively consider the disadvantages associated with them. Methods: Our PET and SPECT simulation modules were developed using Monte Carlo simulation of Electrons and Photons (MCEP), developed by Dr. S. Uehara. PET code (MCEP-PET) generates a sinogram, and reconstructs the tomography image using a time-of-flight ordered subset expectation maximization (TOF-OSEM) algorithm with attenuation compensation. To evaluate MCEP-PET, simulated results of {sup 18}F PET imaging were compared with the experimental results. The results confirmed that MCEP-PET can simulate the experimental results very well. The SPECT code (MCEP-SPECT) models the collimator and NaI detector system, and generates the projection images and projection data. To save the computational time, the authors adopt the prerecorded {sup 90}Y bremsstrahlung photon data calculated by MCEP. The projection data are also reconstructed using the OSEM algorithm. The authors simulated PET and SPECT images of a water phantom containing six hot spheres filled with different concentrations of {sup 90}Y without background activity. The amount of activity was 163 MBq, with an acquisition time of 40 min. Results: The simulated {sup 90}Y-PET image accurately simulated the experimental results. PET image is visually superior to SPECT image because of the low background noise. The simulation reveals that the detected photon number in SPECT is comparable to that of PET, but the large fraction (approximately 75%) of scattered and penetration photons contaminates SPECT image. The lower limit of {sup 90}Y detection in SPECT image was approximately 200 kBq/ml, while that in PET image was approximately 100 kBq/ml. Conclusions: By comparing the background noise level and the image concentration profile of both the techniques, PET image quality was determined to be superior to that of bremsstrahlung SPECT. The developed simulation codes will be very useful in the future investigations of PET and bremsstrahlung SPECT imaging of {sup 90}Y.

07 ISOTOPE AND RADIATION SOURCES↗

Monte-Carlo simulation of noise in hard X-ray Transmission Crystal Spectrometers: Identification of contributors to the background noise and shielding optimization

Transmission crystal spectrometers (TCS) are used on many laser facilities to record hard X-ray spectra. During experiments, signal recorded on imaging plates is often degraded by a background noise. Monte-Carlo simulations made with the code GEANT4 show that this background noise is mainly generated by diffusion of MeV electrons and very hard X-rays. An experiment, carried out at LULI2000, confirmed that the use of magnets in front of the diagnostic, that bent the electron trajectories, reduces significantly this background. The new spectrometer SPECTIX (Spectromètre PETAL à Cristal en TransmIssion X), built for the LMJ/PETAL facility, will include this optimized shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulation of turnover processes in the lunar regolith

A Monte Carlo model for the gardening of the lunar surface by meteoritic impact is described, and some representative results are given. The model accounts with reasonable success for a wide variety of properties of the regolith. The smoothness of the lunar surface on a scale of centimeters to meters, which was not reproduced in an earlier version of the model, is accounted for by the preferential downward movement of low-energy secondary particles. The time scale for filling lunar grooves and craters by this process is also derived. The experimental bombardment ages (about 4 x 10 to the 8th yr for spallogenic rare gases, about 10 to the 9th yr for neutron capture Gd and Sm isotopes) are not reproduced by the model. The explanation is not obvious.

Arnold, J. R.↗

Adaptive kinetic Monte Carlo simulation of methanol decomposition on Cu(100)

The adaptive kinetic Monte Carlo method was used to calculate the dynamics of methanol decomposition on Cu(100) at room temperature over a time scale of minutes. Mechanisms of reaction were found using min-mode following saddle point searches based upon forces and energies from density functional theory. Rates of reaction were calculated with harmonic transition state theory. The dynamics followed a pathway from CH3-OH, CH3-O, CH2-O, CH-O and finally C-O. Our calculations confirm that methanol decomposition starts with breaking the O-H bond followed by breaking C-H bonds in the dehydrogenated intermediates until CO is produced. The bridge site on the Cu(100) surface is the active site for scissoring chemical bonds. Reaction intermediates are mobile on the surface which allows them to find this active reaction site. This study illustrates how the adaptive kinetic Monte Carlo method can model the dynamics of surface chemistry from first principles.

10 SYNTHETIC FUELS↗

Monte Carlo Simulation with CAD Interface for Calculation of 3D Maps of Residual Dose (CRADA)

Objective: To develop an easy-to-use software application to predict and mitigate radiation effects in research environment, space instruments, nuclear plants and medical facilities and help nonproliferation and national security efforts. Tech-X will develop standalone software libraries and command-line tools for ( 1) translating CAD into tessellated surfaces and tetrahedral meshes in GDML (for Geant4 and MARS 15), ROOT (for MARS 15) and HDF5 (for compact representation and for the visualization) formats, (2) healing CAD geometries to make them suitable for Monte Carlo simulations; (3) creating uniform and variable Cartesian and cylindrical meshes for detailed scoring; and ( 4) efficient Monte Carlo navigation in CAD geometries. JLAB will finish automation of simulations of residual dose in CAD geometries and integrate Tech-X software into Geant4 and MARS15. Finally, Tech-X will develop a Graphical User Interface to set up and heal CAD geometries, create input files, run and visualize simulations for residual dose. This application will run on local desktops, local and remote clusters and supercomputers and will be made available through public clouds, such as Amazon Web Services.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulation of backscatter from lead for clinical electron beams using EGSnrc

In electron radiotherapy of superficial lesions in the eyelid, lip, buccal mucosa, ear, and nose, backscattered electrons are produced from the lead shield used to protect the critical tissue underneath the tumor. In this study, the backscattered electrons, produced by clinical electron beams using a Varian 21 EX linear accelerator, were studied using Monte Carlo simulations. The electron backscatter factor (EBF), defined as the ratio of dose at the tissue-lead interface to the dose at the same point without the presence of backscatter, was calculated using the Monte Carlo EGSnrc-based code. The calculated EBFs were verified with measurements using metal-oxide-semiconductor field effect transistor detectors. The effect of the (1) initial electron beam energy, (2) thickness of bolus over the lead shield, (3) beam's angle of incidence, and (4) presence of an aluminum sheet used to absorb backscattered electrons, on the EBF, were studied. It is found that for lead shielding positioned at any fixed depth, the EBF decreases with an increase in initial electron beam energy (4-16 MeV). In addition, for depths within the electron practical range, R{sub p}, and at a particular beam energy, the EBF increases with depth (or thickness of the treatment volume). When the electron beam angle increases from 0 deg. to 5 deg., the EBF only decreases slightly (<4%) for all energies. The influence of the beam obliquity on the EBF is important when the treatment surface is not flat and perpendicular to the central beam axis. The use of an aluminum sheet to reduce backscattered electrons was also investigated. For a relatively low electron beam energy (4 MeV), a 2 mm aluminum sheet can reduce backscattering by 31%. While the electron beam energy increased, less backscattered electrons were produced and therefore removed by the same thickness of aluminum (only about 6% for 16 MeV). The Monte Carlo calculated EBFs from this study, characterized by the electron beam energy, depth of bolus above the lead shield, beam obliquity, and presence of an aluminum sheet, may provide important clinical information for radiation oncology staff when considering the effect of electron backscatter on radiotherapy using internal shielding.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Comparison of Monte-Carlo Simulations and Data from MicroBooNE

This note presents a first comparison of data and Monte-Carlo (MC) simulation at the MicroBooNE experiment, a surface-level liquid argon time projection chamber (LArTPC) located in the Booster Neutrino Beam (BNB) at Fermi National Accelerator Laboratory. Before any analysis can be validated, it is important to ensure understanding of both the performance of the detector and the reconstruction algorithms. Comparing data with simulation can contribute to this effort.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulation of an x-ray luminescence optical tomography scanner prototype

In this work we report the calculation of the deposited energy distribution produced by an x-ray luminescence optical tomography (XLOT) system in a phantom containing different concentrations of Gd{sub 2}O{sub 2}S:Eu nanoparticles. The calculations were performed via Monte Carlo simulation considering spectra from a W target x-ray tube operating between 30 and 90 kVp, with 1.0 mm Al added filtration. CT and XLOT tomographic images were reconstructed from the same data. The results show that XLOT has better detectability than CT alone, that the dose scales linearly with kVp for a fixed concentration of Gd{sub 2}O{sub 2}S:Eu and air-kerma rate, the scattered radiation contribution to the total dose and signal is about 20% and that the dose ratio for a 3 mm diameter insert containing 10 mg/ml Gd{sub 2}O{sub 2}S embedded in a 30 mm diameter water phantom is 6:1. This ratio drops to less than 2:1 for a 1 mg/ml concentration. Finally we show that the method of conjugate images can be used to correct for artifacts due to attenuation effects in XLOT images.

60 APPLIED LIFE SCIENCES↗

SU-E-J-65: Evaluation of a Radiation-Induced Cell Proliferation Probability Formula Using Monte Carlo Simulation

Purpose: To evaluate the analytic formula of the cell death probability after single fraction dose. Methods: Cancer cells endlessly divide, but radiation causes the cancer cells to die. Not all cells die right away after irradiation. Instead, they continue dividing for next few cell cycles before they stop dividing and die. At the end of every cell cycle, the cell decides if it undertakes the mitotic process with a certain probability, Pdiv, which is altered by the radiation. Previously, by using a simple analytic model of radiobiology experiments, we obtained a formula of Pdeath (= 1 − Pdiv). A question is if the proposed probability can reproduce the well-known survival data of the LQ model. In this study, we evaluated the formula by doing a Monte Carlo simulation of the cell proliferation process. Starting with Ns seed cells, the cell proliferation process was simulated for N generations or until all cells die. We counted the number of living cells at the end. Assuming that the cell colony survived when more than Nc cells were still alive, the surviving fraction S was estimated. We compared the S vs. dose, or S-D curve, with the LQ model. Results: The results indicated that our formula does not reproduce the experimentally observed S-D curve without selecting appropriate α and α/β. With parameter optimization, there was a fair agreement between the MC result and the LQ curve of dose lower than 20Gy. However, the survival fraction of MC decreased much faster in comparison to the LQ data for doses higher than 20 Gy. Conclusion: This study showed that the previously derived probability of cell death per cell cycle is not sufficiently accurate to replicate common radiobiological experiments. The formula must be modified by considering its cell cycle dependence and some other unknown effects.

60 APPLIED LIFE SCIENCES↗

Direct Simulation Monte Carlo Studies of the Gas Sampling for the VATMOS-SR Mission Concept

VATMOS-SR (Venus ATMOSpheric - Sample Return) is a small spacecraft mission concept which would return a gas sample from the upper atmosphere of Venus to Earth for scientific analysis. This could be the first sample return mission for an extra-terrestrial atmosphere, and potentially the first sample return from an Earth-sized planet. The VATMOS-SR mission concept consists of a SmallSat atmospheric sampling probe (45 deg. sphere/cone geometry, <1 m diameter) that is designed to skim through the Venus upper atmosphere and acquire gas samples below the homopause altitude (around ~110 km altitude), where the different atmospheric gases are mixed. The velocity of the spacecraft where sampling would occur is expected to be between ~10.5 km/s and ~13.1 km/s, depending on the trajectory chosen. This presentation will discuss hypervelocity sampling in the upper atmosphere of Venus, with respect to the VATMOS-SR mission concept. VATMOS-SR would enable critical atmospheric measurements to form a full picture of how, why, and when Venus evolved to be so different from Earth and Mars. The abundances and isotopic compositions of volatile elements (such as N, C, S, O and the noble gases) in planetary atmospheres record volatile delivery during accretion, outgassing from planetary interiors, and atmospheric loss to space. Precise and accurate determinations of atmospheric volatile signatures are the key to understanding the origins and geodynamical evolution of Venus compared to the other terrestrial planets. Hypersonic sampling poses unique technical and scientific challenges. To ensure it is possible to relate the composition of the sampled gases to the free stream atmospheric composition, large-scale numerical simulations are employed to model the flow through the VATMOS-SR sampling system. In particular, an emphasis is placed on quantifying noble gas isotopic fractionation that occurs during the sample acquisition and transfer process in order to determine how measured isotopic ratios of noble gases in the sample compare to actual isotopic ratios in the Venusian atmosphere. The Direct Simulation Monte Carlo (DSMC) code SPARTA, an open source software package developed by Sandia National Laboratories, is used in this work. SPARTA, based on Bird’s DSMC method, is a molecular-level gas-kinetic technique. As SPARTA is able to model hypervelocity reacting flows in strong chemical and thermal non-equilibrium, this software package is well suited to determine relevant flow properties for the VATMOS-SR mission concept, and to numerically quantify the expected level of elemental and/or isotopic fractionation in the sample acquired by VATMOS-SR. This presentation will show results from 3D simulations correlating the noble gas isotopic fractionation in the gas acquired at hypervelocity speeds to its ambient atmosphere value. In particular, emphasis will be placed at Xenon isotopes of masses 128 and 130, as precise measurements of that ratio would yield a comparison to Earth’s atmosphere. Additionally, sensitivity studies that quantify the uncertainties due to the freestream parameters as well as the modeling parameters will be performed.

direct simulation Monte Carlo↗

TU-H-CAMPUS-IeP1-03: Comparison of Monte Carlo Simulation and Conversion Factor Based Method On Estimation of Effective Dose in Pediatric Patients Undergoing Interventional Cardiac Procedures

Purpose: Interventional cardiac procedures utilize frequent fluoroscopy and cineangiography, which impose considerable radiation risk to patients, especially pediatric patients. Accurate calculation of effective dose is important in order to estimate cancer risk over the rest of their lifetime. This study evaluates the difference in effective dose calculated by Monte Carlo simulation with those estimated by locally-derived conversion factors (CF-local) and by commonly quoted conversion factors from Karambatsakidou et al (CF-K). Methods: Effective dose (E),of 12 pediatric patients, age between 2.5–19 years old, who had undergone interventional cardiac procedures, were calculated using PCXMC-2.0 software. Tube spectrum, irradiation geometry, exposure parameters and dose-area product (DAP) of each projection were included in the software calculation. Effective doses for each patient were also estimated by two Methods: 1) CF-local: conversion factor derived locally by generalizing results of 12 patients, multiplied by DAP of each patient gives E-local. 2) CF-K: selected factor from above-mentioned literature, multiplied by DAP of each patient gives E-K. Results: Mean of E, E-local and E-K were 16.01 mSv, 16.80 mSv and 22.25 mSv respectively. A deviation of −29.35% to +34.85% between E and E-local, while a greater deviation of −28.96% to +60.86% between E and EK were observed. E-K overestimated the effective dose for patients at age 7.5–19. Conclusion: Effective dose obtained by conversion factors is simple and quick to estimate radiation risk of pediatric patients. This study showed that estimation by CF-local may bear an error of 35% when compared with Monte Carlo calculation. If using conversion factors derived by other studies may result in an even greater error, of up to 60%, due to factors that are not catered for in the estimation, including patient size, projection angles, exposure parameters, tube filtration, etc. Users must be aware of these potential inaccuracies when simple conversion method is employed.

60 APPLIED LIFE SCIENCES↗