Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optimized Configurations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

THE HYDROGEN EPOCH OF REIONIZATION ARRAY DISH. I. BEAM PATTERN MEASUREMENTS AND SCIENCE IMPLICATIONS

The Hydrogen Epoch of Reionization Array (HERA) is a radio interferometer aiming to detect the power spectrum of 21 cm fluctuations from neutral hydrogen from the epoch of reionization (EOR). Drawing on lessons from the Murchison Widefield Array and the Precision Array for Probing the EOR, HERA is a hexagonal array of large (14 m diameter) dishes with suspended dipole feeds. The dish not only determines overall sensitivity, but also affects the observed frequency structure of foregrounds in the interferometer. This is the first of a series of four papers characterizing the frequency and angular response of the dish with simulations and measurements. In this paper, we focus on the angular response (i.e., power pattern), which sets the relative weighting between sky regions of high and low delay and thus apparent source frequency structure. We measure the angular response at 137 MHz using the ORBCOMM beam mapping system of Neben et al. We measure a collecting area of 93 m{sup 2} in the optimal dish/feed configuration, implying that HERA-320 should detect the EOR power spectrum at z ∼ 9 with a signal-to-noise ratio of 12.7 using a foreground avoidance approach with a single season of observations and 74.3 using a foreground subtraction approach. Finally, we study the impact of these beam measurements on the distribution of foregrounds in Fourier space.

79 ASTRONOMY AND ASTROPHYSICS↗

An Approach to Enhance pnetCDF Performance in Environmental Modeling Applications

I/O has been considered as a bottleneck in parallel applications. The software package, pnetCDF which works with parallel file systems, was developed to address this issue and provide parallel I/O capability. This study examines the performance of a novel approach which performs data aggregation along either row or column dimension of the spatial domain, and then applies the pnetCDF parallel I/O paradigm. The test was done with three different domain sizes which represents small, moderately large and large data domains, using a small scale Community Multi-scale Air Quality model (CMAQ) mocked up code. The examination includes comparing I/O performance with traditional serial I/O technique, straight application of pnetCDF, and the data aggregation along row and column dimension before applying pnetCDF. After the comparison, “optimal” I/O configurations for this new novel approach were quantified. Data aggregation along the row dimension (pnetCDFcr) works better than along the column dimension (pnetCDFcc) although it may perform slightly worse than straight the pnetCDF method with a small number of processors. When the number of processors becomes larger, pnetCDFcr out performs pnetCDF significantly. If the number of processors keeps increasing, pnetCDF reaches a point that the performance is even worse than the serial I/O technique. This new approach has also been tested on a real application where it performs two times better than the straight pnetCDF paradigm.

I/O↗

High-Resolution WRF-Based Downscaling of Earth System Model Projections for Energy Applications across CONUS

Evaluating energy resources under future scenarios requires meteorological information that adequately resolves regional-scale variability and is suitable for regional energy system studies. Although Earth system model (ESM) outputs provide essential large-scale context, their coarse resolution and inherent biases limit direct use in energy system applications. This work presents a high-resolution dynamical downscaling framework using the Weather Research and Forecasting (WRF) model to generate energy-relevant regional fields for future scenarios over the contiguous United States (CONUS). The framework first identifies an optimal WRF configuration through sensitivity experiments, then evaluates raw and bias-corrected ESM initial and boundary conditions, with soil moisture and soil temperature bias correction implemented as an integral component of the bias-corrected ESM atmospheric forcing prior to WRF dynamical downscaling to improve land-atmosphere interactions. Simulations performed at 4-km resolution show that uncorrected ESM forcing leads to systematically dry and cold soil states, which propagate into elevated near-surface air temperature and solar irradiance biases, particularly during summer for the period 2000-2014. Incorporating bias-corrected atmospheric forcing together with soil state bias correction substantially reduces these errors and improves the representation of surface energy processes in WRF simulations. The results highlight the importance of bias-aware initialization strategies in high-resolution dynamical downscaling for future energy system analysis and planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Computational Tools for Accelerating Carbon Capture Process Development

This presentation reports development of advanced computational tools to accelerate next generation technology development. These tools are to develop an optimized process using rigorous models. They include: Process Models; Simulation-Based Optimization; Optimized Process; Uncertainty Quantification; Algebraic Surrogate Models; and Superstructure Optimization (Determine Configuration).

20 FOSSIL-FUELED POWER PLANTS↗

Minimum Detectable Activity for Tomographic Gamma Scanning System

For any radiation measurement system, it is useful to explore and establish the detection limits and a minimum detectable activity (MDA) for the radionuclides of interest, even if the system is to be used at far higher values. The MDA serves as an important figure of merit, and often a system is optimized and configured so that it can meet the MDA requirements of a measurement campaign. The non-destructive assay (NDA) systems based on gamma ray analysis are no exception and well established conventions, such the Currie method, exist for estimating the detection limits and the MDA. However, the Tomographic Gamma Scanning (TGS) technique poses some challenges for the estimation of detection limits and MDAs. The TGS combines high resolution gamma ray spectrometry (HRGS) with low spatial resolution image reconstruction techniques. In non-imaging gamma ray based NDA techniques measured counts in a full energy peak can be used to estimate the activity of a radionuclide, independently of other counting trials. However, in the case of the TGS each “view” is a full spectral grab (each a counting trial), and each scan consists of 150 spectral grabs in the transmission and emission scans per vertical layer of the item. The set of views in a complete scan are then used to solve for the radionuclide activities on a voxel by voxel basis, over 16 layers of a 10x10 voxel grid. Thus, the raw count data are not independent trials any more, but rather constitute input to a matrix solution for the emission image values at the various locations inside the item volume used in the reconstruction. So, the validity of the methods used to estimate MDA for an imaging technique such as TGS warrant a close scrutiny, because the pair-counting concept of Currie is not directly applicable. One can also raise questions as to whether the TGS, along with other image reconstruction techniques which heavily intertwine data, is a suitable method if one expects to measure samples whose activities are at or just above MDA levels. The paper examines methods used to estimate MDAs for a TGS system, and explores possible solutions that can be rigorously defended.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulating the Effects of Stellarator Geometry on Gyrokinetic Drift-Wave Turbulence

Nuclear fusion is a clean, safe form of energy with abundant fuel. In magnetic fusion energy (MFE) experiments, the plasma fuel is confined by magnetic fields at very high temperatures and densities. One fusion reactor design is the non-axisymmetric, torus-shaped stellarator. Its fully-3D fields have advantages over the simpler, better-understood axisymmetric tokamak, including the ability to optimize magnetic configurations for desired properties, such as lower transport (longer confinement time). Turbulence in the plasma can break MFE confinement. While turbulent transport is known to cause a significant amount of heat loss in tokamaks, it is a new area of research in stellarators. Gyrokinetics is a good mathematical model of the drift-wave instabilities that cause turbulence. Multiple gyrokinetic turbulence codes that had great success comparing to tokamak experiments are being converted for use with stellarator geometry. This thesis describes such adaptations of the gyrokinetic turbulence code, GS2. Herein a new computational grid generator and upgrades to GS2 itself are described, tested, and benchmarked against three other gyrokinetic codes. Using GS2, detailed linear studies using the National Compact Stellarator Experiment (NCSX) geometry were conducted. The first compares stability in two equilibria with different beta=(plasma pressure)/(magnetic pressure). Overall, the higher beta case was more stable than the lower beta case. As high beta is important for MFE experiments, this is encouraging. The second compares NCSX linear stability to a tokamak case. NCSX was more stable with a 20% higher critical temperature gradient normalized by the minor radius, suggesting that the fusion power might be enhanced by about 50%. In addition, the first nonlinear, non-axisymmetric GS2 simulations are presented. Finally, linear stability of two locations in a W7-AS plasma were compared. The experimentally-measured parameters used were from a W7-AS shot in which measured heat fluxes match neoclassical theory predictions at inner radii, but are too large for neoclassical predictions at outer radii. Results from GS2 linear simulations show that the outer location has higher gyrokinetic instability growth rates than at the inner one. Mixing-length estimates of the heat flux are within a factor of 3 of the experimental measurements, indicating that gyrokinetic turbulence may be responsible for the higher transport measured by the experiment in the outer regions. Future nonlinear simulations can explore this question in more detail.

Gyrokinetics↗

ASSESSMENT OF MULTIPHASE CFD WITH ZERO CLOSURE MODEL FOR BOILING WATER REACTOR FUEL ASSEMBLIES

Extension of existing boiling closures to the high void fraction conditions of BWRs is one of challenges for M-CFD applications. This paper presents the assessment of an Eulerian M-CFD model with Zero closure model that has been specifically designed for two-phase flow and heat transfer applications in BWR fuel assemblies. The baseline Zero closure aims at including the simplest and most robust representation of the key physical mechanisms, rather than aiming at absolute accuracy of the predictions. The capabilities of M-CFD with Zero were evaluated against the international OECD/NRC BFBT benchmark data through the comparative analyses of local void fraction, sub-channel void fraction error and exit quality. INL high performance computing system has been employed to demonstrate the scalability of the M-CFD application to nuclear reactor fuel assemblies. The M-CFD simulation results show a good agreement with the experimental data for both quantitative and qualitative results, with the highest uncertainty being observed in the prediction of the local void fraction profile at low void fraction condition. This paper presents a recent view of the best practices for M-CFD of BWR fuel assemblies to provide a useful reference to identify and overcome common challenges in the applications of M-CFD tools. We provide recommendations for geometric modeling, mesh generation and solver configurations to optimize the methodology application.

97 MATHEMATICS AND COMPUTING↗

Thermal Desalination as Cooling for a Supercritical Carbon Dioxide Brayton Cycle

Multi-effect distillation (MED) is commonly used for seawater desalination. MED offers numerous advantages over other existing thermal desalination systems. MED systems are commonly integrated with a steam-Rankine power cycle, for simultaneous production of power and freshwater. Low-pressure steam is extracted from the power cycle to act as a heat source for the MED. The operating temperature of the low-pressure steam must be high enough to drive the MED system. This necessitates an increase in the operating pressure on the power-cycle condenser, resulting in a decrease in power production. Hence, integration of MED with the steam-Rankine cycle is a parasitic load for the power plant. The supercritical carbon dioxide (sCO2) Brayton cycle is being pursued as a new power cycle because of its potential for higher energy efficiency and compact turbomachinery. The sCO2 exiting the low-temperature recuperator is quite hot and is cooled as a sensible-heat fluid before flowing back to the compressor. This heat is sufficiently hot to drive an MED system, rather than being rejected to the environment. Such a thermal integration could lead to simultaneous production of power and potable water without affecting the sCO2 Brayton cycle efficiency. The objective of the present study is to maximize the distillate production from MED without acting as a parasitic load. Optimal feed configuration for the MED is identified for maximizing the distillate concentration. Techno-economic analysis showed the cost of distillate for MED is about 30% lower than distillate produced by reverse osmosis (RO).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Balanced light detector

A system and method with AC coupling that reserves photodiode bandwidth in a biased configuration, allows optimal transimpedance amplifier performance, retains DC signal measurement capability, and does not introduce noise into the balanced detection signal.

Williams, Brian P.↗

Multi-Objective Cycle Optimization of an Integrally Geared Waste Heat Recovery Unit for a Combined Cycle Power System

This paper has presented the cycle design and optimization details for a sCO2-based WHRS targeting the Solar Turbines Titan 130. The PreheatSR cycle layout was chosen to effectively address the issue of acid dew point corrosion and ensure high system performance is not significantly impacted by use of alternative fuels. The optimization process discussed uses a multi-objective optimization to discover a series of optimal cycle configurations given ambient temperature variability for a chosen site location while considering the initial capital cost of the cycle components. Cycle models built that incorporated off-design methods for the heat exchangers and turbomachinery allowed for the investigation of cycle operation that maximizes power output for individual cycle conditions. The resulting Pareto front serves as a guide for how to configure the WHRS cycle for the highest yearly energy extracted for a given investment.

20 FOSSIL-FUELED POWER PLANTS↗

Balanced light detector

A system and method with AC coupling that reserves photodiode bandwidth in a biased configuration, allows optimal transimpedance amplifier performance, retains DC signal measurement capability, and does not introduce noise into the balanced detection signal.

Williams, Brian P.↗

A simple flow analysis of diffuser-getter-diffuser systems

Tritium clean-up systems typically deploy gas processing technologies between stages of palladium-silver (Pd/Ag) diffusers/permeators. The number of diffusers positioned before and after a gas clean-up process to obtain optimal system performance will vary with feed gas inert composition. A simple method to analyze optimal diffuser configuration is presented. The method assumes equilibrium across the Pd/Ag tubes and system flows are limited by diffuser vacuum pump speeds preceding or following the clean-up process. A plot of system feed as a function of inert feed gas composition for various diffuser configuration allows selection of a diffuser configuration for maximum throughput based on feed gas composition. (authors)

42 ENGINEERING↗

Expected count rate for the Self- Interrogation Neutron Resonance Densitometry measurements of spent nuclear fuel

The Self-Interrogation Neutron Resonance Densitometry (SINRD) is a passive neutron technique that aims at a direct quantification of {sup 239}Pu in the fuel assemblies by measuring the attenuation of the neutron flux in the energy region close to the 0.3 eV resonance of {sup 239}Pu. The {sup 239}Pu mass is estimated by calculating the SINRD signature, that is the ratio between the neutron flux integrated over the fast energy region and around the 0.3 eV resonance region. The SINRD measurement approach considered in this study consists in introducing a small neutron detector in the central guide tube of a PWR 17x17 fuel assembly. In order to measure the neutron flux in the energy regions defined in the SINRD signature, different detector types are used. The response of a bare {sup 238}U fission chamber is considered for the determination of the fast neutron flux, while other thermal-epithermal detectors wrapped in neutron absorbers are envisaged to measure the neutron flux around the resonance region. This paper provides an estimation of the count rate that can be achieved with the detector types proposed for the SINRD measurement. In the first section a set of detectors are evaluated in terms of count rate and sensitivity to the {sup 239}Pu content, in order to identify the optimal measurement configuration for each detector type. Then a study is performed to increase the count rate by increasing the detector size. The study shows that the highest count rate is achieved by using either {sup 3}He or {sup 10}B proportional counters because of the high neutron efficiency of these detectors. However, the calculations indicate that the biggest contribution to the measurement uncertainty is due to the measurement of the fast neutron flux. Finally, similar sensitivity to the {sup 239}Pu content is obtained by using the different detector types for the measurement of the neutron flux close to the resonance region. Therefore, the count rate associated to each detector type will play a major role in the selection of the detector types used for the SINRD measurement. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Minimum detectable activity for tomographic gamma scanning system - 15648

For any radiation measurement system, it is useful to explore and establish the detection limits and a minimum detectable activity (MDA) for the radionuclides of interest, even if the system is to be used at far higher values. The MDA serves as an important figure of merit, and often a system is optimized and configured so that it can meet the MDA requirements of a measurement campaign. The non-destructive assay (NDA) systems based on gamma ray analysis are no exception and well established conventions, such the Currie method, exist for estimating the detection limits and the MDA. However, the Tomographic Gamma Scanning (TGS) technique poses some challenges for the estimation of detection limits and MDAs. The TGS combines high resolution gamma ray spectrometry (HRGS) with low spatial resolution image reconstruction techniques. In non-imaging gamma ray based NDA techniques measured counts in a full energy peak can be used to estimate the activity of a radionuclide, independently of other counting trials. However, in the case of the TGS each 'view' is a full spectral grab (each a counting trial), and each scan consists of 150 spectral grabs in the transmission and emission scans per vertical layer of the item. The set of views in a complete scan are then used to solve for the radionuclide activities on a voxel by voxel basis, over 16 layers of a 10x10 voxel grid. Thus, the raw count data are not independent trials any more, but rather constitute input to a matrix solution for the emission image values at the various locations inside the item volume used in the reconstruction. So, the validity of the methods used to estimate MDA for an imaging technique such as TGS warrant a close scrutiny, because the pair-counting concept of Currie is not directly applicable. One can also raise questions as to whether the TGS, along with other image reconstruction techniques which heavily intertwine data, is a suitable method if one expects to measure samples whose activities are at or just above MDA levels. The paper examines methods used to estimate MDAs for a TGS system, and explores possible solutions that can be rigorously defended. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Challenges Conducting a Radiological Site Assessment at a Remote Uranium Mine - 16259

A radiological site assessment was performed as part of an environmental site assessment at a former uranium mine located in the Northwest Territories of Canada. The only access to the site was by helicopter, so the field program was a limited to only a few days. Radiological surveys were conducted to assess conditions for safety of the field crew as well as to provide overland survey of uranium at the site. Limited radiological data existed for this site and the objective was to collect as much data as possible during the short field program. ScanPlot{sup SM} gamma spectroscopy land survey system was utilized for the overland survey utilizing a backpack system. ScanPlotSM platform utilized spectroscopy grade sodium iodide detectors configured for optimal spatial coverage and radiation detection. Survey locations were recorded using an on-board global positioning system (GPS). The radiological spectral data from the radiation detectors is automatically logged and linked with the GPS coordinates to an on-board computer to create iso-contour figures using a color scale to represent radioactivity levels (ground concentration by radionuclide). The advantage of utilizing the ScanPlotSM system for this assessment is that the nature and extent of uranium is provided without having to collect and assay a large number of samples during a short period of time. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Intelligent driving passive pedal control

A method for assignment of vehicle control includes receiving route data indicating a route between a starting location of a vehicle and a destination location, and determining an optimal vehicle configuration for the route based on a target vehicle speed and a hybrid torque split. The method further includes receiving a driver requested torque value and determining a passive pedal torque value based on the route data and vehicle powertrain data. The method further includes selectively assigning control of the vehicle to a vehicle system or to a driver of the vehicle based on the driver requested torque value and the passive pedal torque value.

Aggoune, Karim↗

Reducing Cost of Chlorinated Volatile Organic Compound Remediation by Transitioning from Active to Passive Soil Vapor Extraction - 20157

Areas of high chlorinated volatile organic compound (cVOC) contamination at the Savannah River Site (SRS) have been undergoing remediation via soil vapor extraction, sometimes coupled with thermal treatments to enhance extraction rates. These active systems are effective in removing large amounts of contaminant mass from the subsurface and mitigating the impacts to groundwater. However, as extraction rates decline, costs must be evaluated with respect to the benefit of continued active operation. A decision framework for identifying conditions when a transition to a more passive remediation is appropriate has been developed with state and federal regulatory agencies. Two remediation areas have recently been transitioned from active soil vapor extraction (ASVE) to passive soil vapor extraction (PSVE) at the SRS. Performance evaluation goals including plume stabilization, overall mass removal trends, environmental sustainability and costs were considered in transitioning from active remediation to passive technologies at both sites. At the Dynamic Underground Stripping (DUS) project at the M-Area Settling Basin, ASVE was combined with steam injection to extract cVOCs during active operations. Steam injection occurred from September 2005 to September 2009. DUS utilized 63 steam injection wells, 34 active vapor extraction wells, and 3 active soil vapor extraction units (SVEUs). Two active SVEUs had 60 horsepower blowers; the third had a 25-horsepower blower. Mass removal was closely tracked during DUS operations; over 181,437 kilograms (400,000 pounds) of cVOCs were removed while active steam injection occurred. After steaming was stopped, ASVE continued. The 34 active wells were evaluated in 2012. The ASVE wells were grouped into categories of high, medium, and low extraction rates. High producing wells remained connected to a single active SVEU. Low producing wells were abandoned, and the medium producing wells were transitioned to PSVE (Microblowers{sup TM}). Microblowers{sup TM} utilize a dedicated blower per well and are solar powered. This passive technology provides energy, maintenance, and operation costs savings while still providing an efficient reduction in cVOC migration to groundwater. In 2018, the remaining ASVE wells were evaluated again. The purpose of this testing was to identify which wells removed the most mass. An optimal well configuration was determined. The criteria to discontinue ASVE was removal of less than 18 kilograms (40 pounds) per week of cVOCs. After 3 months of shutdown (rebound conditions), 2.7 kilograms (5.9 pounds) of cVOCs per week were being removed. Data from the rebound test justified ending ASVE and transitioning wells with higher extraction rates to PSVE. Wells that had depleted the cVOC mass within their zone of influence were abandoned. Performance data from existing PSVE wells justified ending PSVE at wells with depleted extraction rates. Currently the system has 16 PSVE wells operating. Another ASVE system was being used to treat cVOC contaminated soil at the A-Area Miscellaneous Rubble Pile (AMRP) at SRS. System operation began in 2004, with 7 ASVE wells connected to a 60- horsepower blower. Mass removal rates and contaminant concentrations remained consistently low over the ASVE lifespan at AMRP. This indicated that mass removal was diffusion limited. With this data, the 7 ASVE wells were transitioned to PSVE in 2017. Twelve pressure monitoring points were also transitioned to PSVE wells. AMRP currently has 19 PSVE wells operating. Both transitions from active to passive remediation had concurrence from the United States Environmental Protection Agency and the South Carolina Department of Health and Environmental Control. These transitions ensure that only the necessary amount of energy is being exerted to remediate the environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗