Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASMA FLUX MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Equatorially trapped plasma populations

The SCATHA observations of the equatorially trapped plasmas are presented in order to emphasize the importance of making measurements at the equator. The UCSD plasma detector and the GSFC electric field experiment are described, as are the pertinent characteristics of the magnetometer and mass spectrometers. The electron distribution reveals a width of 20 deg to 60 deg, narrowing with increasing energy. The 20- to 100-eV ion fluxes typically exhibit temperatures in the 20to 50-eV range and densities of 1-10 per cu cm. The electron population typically ranges from 50 to 500 eV, with temperatures of 100-200 eV and densities also in the 1-10 per cu cm range. Field-aligned populations of lower energy are occasionally found in both ions and electrons at the same location.

Olsen, R. C.↗

Auroral emissions and particle precipitation in the noon sector.

Comparison of airborne optical measurements during December 1969 with satellite particle measurements made earlier in 1969. The latitudinal distributions of H beta, 4278-A and 6300-A emissions during quiet periods are observed to agree with what would be expected from the latitudinal distribution of particle precipitation during similar conditions. In particular, there is a belt 200 to 500 km wide (at ionospheric heights) in which the magnetosheath plasma penetrates down to low altitudes through the cusps in the dayside magnetosphere and in which both H beta and 6300-A emissions are observed. There are brighter red arcs with green lower borders within this belt. It is suggested that these are produced by narrow regions of precipitation of slightly more energetic electrons embedded in the cusp fluxes. Poleward of this belt the flux of particles is low, and the atmospheric emissions are very weak, except for occasional narrow regions of electron precipitation (without measurable protons) and the corresponding polar-cap aurora (without the H beta emission).

Heikkila, W. J.↗

Glucose metabolism in different regions of the rat brain under hypokinetic stress influence

Glucose metabolism in rats kept under long term hypokinetic stress was studied in 7 brain regions. Determination was made of the regional levels of glucose, lactate, glutamate, glutamine, aspartate, gamma-aminobutyrate and the incorporation of C-14 from plasma glucose into these metabolites, in glycogen and protein. From the content and activity data the regional glucose flux was approximated quantitatively. Under normal conditions the activity gradient cortex and frontal pole cerebellum, thalamus and mesencephalon, hypothalamus and pons and medulla is identical with that of the regional blood supply (measured with I131 serum albumin as the blood marker). Within the first days of immobilization a functional hypoxia occurred in all brain regions and the utilization of cycle amino acids for protein synthesis was strongly diminished. After the first week of stress the capillary volumes of all regions increased, aerobic glucose metabolism was enhanced (factors 1.3 - 2.0) and the incorporation of glucose C-14 via cycle amino acids into protein was considerably potentiated. The metabolic parameters normalized between the 7th and 11th week of stress. Blood supply and metabolic rate increased most in the hypothalamus.

Konitzer, K.↗

Thermal He(+) in the plasmasphere - Comparison of observations with numerical calculations

Observations made by the retarding ion mass spectrometer on the Dynamics Explorer-1 satellite are used to study the relationship between He(+) and H(+). The observations are compared to theoretical values obtained using the field line interhemispheric plasma model (Richards and Torr, 1988). The observations are presented in the form of statistical L shell distributions and density versus L shell profiles. To obtain agreement between the measured and predicted ion temperature, it must be assumed that approximaterly 55 pct of the energy of the ionospheric photoelectron escape flux is deposited in the plasmasphere.

Newberry, I. T.↗

Subresolution Fibrillation in X-Ray Microflares Observed by Yohkoh SXT

We analyze the cooling of the X-ray plasma in microflares observed in active regions by the Yohkoh Soft X-ray Telescope (SXT). A typical microflare appears to be a transient brightening of an entire small magnetic loop, often having a diameter near the limit of resolution (approx. 2 x 10(exp 8) cm). The plasma heated to X-ray temperatures in the body of the loop cools by emission of XUV radiation and by heat conduction to the cooler plasma at the feet of the loop. The cooling rate is determined by the plasma temperature and density and the loop length. The plasma density is determined from the observed X-ray brightness of the loop in combination with the temperature, the loop diameter, and the filling factor. The filling factor is the volume fraction of the loop occupied by the subset of magnetic tubes that is fluid by the X-ray plasma and that contains practically all of the X-ray plasma present in the microflare loop. Taking typical values from the hundreds of microflares measured by Shimizu (X-ray brightness through the thin aluminum filter - 4 x 10(exp 3) DN/s/pixeL lifetime approx. 5 min, temperature approx. 6 x 10(exp 6) K, loop length approx. 10(exp 9) cm, loop diameter approx. 3 x 10(exp 8) cm), we find that for filling factors greater than approx. 1%: (1) the cooling time is much shorter than the duration of the microflare, and (2) conductive cooling strongly dominates over radiative cooling. Because the cooling time is so short and because the conductive heat flux goes mainly into increasing the plasma density via chromospheric evaporation, we are compelled to conclude that: (1) heating to X-ray temperatures continues through nearly the entire lifetime of the microflare, (2) die heating keeps changing to different field lines, so that any one magnetic tube in the sequence of heated tubes emits X-rays only briefly in the life of the microflare, and (3) at any instant during the microflare the tubes filled with X-ray plasma occupy only a small fraction (approx. 10%) of the microflare loop. Hence, we expect that coronal X-ray images with spatial resolution 2-3 times better than from the Yohkoh SXT will show plenty of rapidly changing filamentary substructure in microflares. Our results also suggest that the heating in microflares may result from progressive reconnection similar to that inferred in many larger flares.

Moore, Ron↗

Photoelectron energy loss and spectral features deduced by the plasma line technique

Plasma line data gathered at the Arecibo Observatory are used to examine relative variations in topside F region differential photoelectron fluxes in the 5- to 20-eV range. A spectral feature not found in present theoretically calculated spectra is noted near 15 eV. A new approach to the interpretation of the measured spectra is taken, which allows a qualitative estimate of the relative importance of different energy loss mechanisms. The altitude variation of the observed photoelectron flux energy spectra at the higher altitudes (above 350 km) and the lower energies (less than 10 eV) agrees quantitatively with the expected variation of the spectrum.

Abreu, V. J.↗

Heat flux at the thermionic collector

Heat flux arriving at the thermionic collector is theoretically considered to be composed of an electron heating term, proportional to the output current, plus the radiation and conduction terms. However, the measured electron heating term is always larger than what one would expect from the accepted theory. In this paper, the electron heating term at the collector is theoretically calculated as a sum of the conventional electron heating term and the heat flux which is carried into the collector by the random plasma current. The arriving random electrons and ions are considered to recombine nonradiatively at the collector surface after imparting their kinetic energies to the collector, in addition to the ionization potential energy. In this process, random electrons do not lose their potential energy equal to the collector work function, since they do not contribute to the output current.

Shimada, K.↗

Discovery of an Afterglow Extension of the Prompt Phase of Two Gamma Ray Bursts Observed by Swift

Contemporaneous BAT and XRT observations of two recent well-covered GRBs observed by Swift, GRB 050315 and GRB 050319, show clearly a prompt component of the afterglow emission. The rapid slewing capability of the spacecraft enables X-ray observations immediately after the burst, typically approximately 100 s following the initiation of the prompt gamma-ray phase. By fitting a power law form to the gamma-ray spectrum, we extrapolate the time dependent fluxes measured by the BAT, in the energy band 15 - 350 keV, into the spectral regime observed by the XRT, 0.2 - 10 keV, and examine the functional form of the rate of decay of the two light curves. We find that the BAT and XRT light curves merge to form a unified curve. There is a period of steep decay up to approximately 300 s, followed by a flatter decay. The duration of the steep decay, approximately 100 s in the source frame after correcting for cosmological time dilation, agrees with a theoretical estimate for the deceleration time of the relativistic ejecta as it interacts with circumstellar material. For GRB 050315, the steep decay can be characterized by an exponential form, where T(sub e),(BAT)approximately equal to 24 plus or minus 2 s, and T(sub e)(XRT) approximately equal to 35 plus or minus 2 s. For GRB 050319 a power law decay -d lnf/d lnt = n, where n approximately equal to 3, provides a reasonable fit. The early time X-ray fluxes are consistent with representing the lower energy tail of the prompt emission, and provide our first quantitative measure of the decay of the prompt gamma-ray emission over a large dynamic range. The initial steep decay is expected from the high latitude emission from a curved shell of relativistic plasma illuminated only for a short interval. The overall conclusion is that the prompt phase of GRBs lasts for hundreds of seconds longer than previously thought.

Barthelmy, S. D.↗

The Vector Electric Field Instrument on the C/NOFS Satellite

We provide an overview of the Vector Electric Field Instrument (VEFI) on the Air Force Communication/Navigation Outage Forecasting System (C/NOFS) satellite, a mission designed to understand, model, and forecast the presence of equatorial ionospheric irregularities. VEFI is a NASA GSFC instrument designed 1) to investigate the role of the ambient electric fields in initiating nighttime ionospheric density depletions and turbulence; 2) to determine the electric fields associated with abrupt, large amplitude, density depletions and 3) to quantify the spectrum of the wave electric fields and plasma densities (irregularities) associated with density depletions or Equatorial Spread-F. The VEFI instrument includes a vector electric field double probe detector, a Langmuir trigger probe, a flux gate magnetometer, a lightning detector and associated electronics. The heart of the instrument is the set of double probe detectors designed to measure DC and AC electric fields using 6 identical, mutually orthogonal, deployable 9.5 m booms tipped with 10 cm diameter spheres containing embedded preamplifiers. A description of the instrument and its sensors will be presented. If available, representative measurements will be provided.

Pfaff, R.↗

Making AlN(x) Tunnel Barriers Using a Low-Energy Nitrogen-Ion Beam

A technique based on accelerating positive nitrogen ions onto an aluminum layer has been demonstrated to be effective in forming thin (<2 nm thick) layers of aluminum nitride (AlN(x)) for use as tunnel barriers in Nb/Al-AlN(x)/Nb superconductor/insulator/ superconductor (SIS) Josephson junctions. AlN(x) is the present material of choice for tunnel barriers because, to a degree greater than that of any other suitable material, it offers the required combination of low leakage current at high current density and greater thermal stability. While ultra-thin AlN films with good thickness and stoichiometry control are easily formed using techniques such as reactive molecular beam epitaxy and chemical vapor deposition, growth temperatures of 900 C are necessary for the dissociative adsorption of nitrogen from either nitrogen (N2) or ammonia (NH3). These growth temperatures are prohibitively high for the formation of tunnel barriers on Nb films because interfacial reactions at temperatures as low as 200 to 300 C degrade device properties. Heretofore, deposition by reactive sputtering and nitridation of thin Al layers with DC and RF nitrogen plasmas have been successfully used to form AlN barriers in SIS junctions. However, precise control over critical current density Jc has proven to be a challenge, as is attaining adequate process reproducibility from system to system. The present ion-beam technique is an alternative to the plasma or reactive sputtering techniques as it provides a highly controlled arrival of reactive species, independent of the electrical conditions of the substrate or vacuum chamber. Independent and accurate control of parameters such as ion energy, flux, species, and direction promises more precise control of film characteristics such as stoichiometry and thickness than is the case with typical plasma processes. In particular, the background pressure during ion-beam nitride growth is 2 or 3 orders of magnitude lower, minimizing the formation of compounds with contaminants, which is critical in devices the performance of which is dictated by interfacial characteristics. In addition, the flux of incoming species can be measured in situ using ion probes so that the dose can be controlled accurately. The apparatus used in the present ion-beam technique includes a vacuum chamber containing a commercial collimated- ion-beam source, a supply of nitrogen and argon, and an ion probe for measuring the ion dose. Either argon or nitrogen can be used as the feed gases for the ion source, depending on whether cleaning of the substrate or growth of the nitride, respectively, is desired. Once the Nb base electrode and Al proximity layer have been deposited, the N2 gas line to the ion beam is vented and purged, and the ion-source is turned on until a stable discharge is obtained. The substrate is moved over the ion-beam source to expose the Al surface layer to the ion beam (see figure) for a specified duration for the formation of the nitride tunnel barrier. Next, the Nb counter-electrode layer is deposited on the nitride surface layer. The Nb/Al- AlN(x)/Nb-trilayer-covered substrate is then patterned into individual devices by use of conventional integrated-circuit processing techniques.

Kaul, Anupama↗

Evidence that the X-Ray Plasma in Microflares is in a Sequence of Subresolution Magnetic Tubes

We analyze the cooling of the X-ray emitting thermal plasma in microflares observed in active regions by the Yohkoh Soft X-ray Telescope. A typical microflare appears to be a transient brightening of an entire small magnetic loop, often having a diameter near the limit of resolution (approximately 2 x 10(exp 8) cm) (Shimizu 1995, PASJ, 47, 251). The X-ray plasma in the loop cools by emission of XUV radiation and by heat conduction to the cooler plasma at the feet of the loop. The cooling rate is determined by the plasma temperature and density and the loop length. The plasma density is determined from the observed X-ray brightness of the loop in combination with the temperature, the loop diameter, and the filling factor. The filling factor is the volume fraction of the loop occupied by the subset of magnetic tubes that is filled by the X-ray plasma and that contains practically all of the X-ray plasma present in the microflare loop. Taking typical values from the hundreds of microflares measured by Shimizu (1995) (X-ray brightness through the thin aluminum filter approximately 4 x 10(exp 3) DN/s/pixel, lifetime approximately 5 min, temperature approximately 6 x 10(exp 6) K, loop length approximately 10(exp 9) cm, loop diameter approximately 3 x 10(exp 8) cm), we find that for filling factors greater than approximately 1% (1) the cooling time is much shorter than the duration of the microflare, and (2) conductive cooling strongly dominates over radiative cooling. Because the cooling time is so short and because the conductive heat flux goes mainly into increasing the plasma density via chromospheric evaporation, we are compelled to conclude that (1) heating to X-ray temperatures continues through nearly the entire life of a microflare, (2) the heating keeps changing to different field lines, so that any one magnetic tube in the sequence of heated tubes emits X-rays only briefly in the life of the microflare, and (3) at any instant during the microflare the tubes filled with X-ray plasma occupy only a small fraction (less than approximately 10%) of the microflare loop. Hence, we expect that coronal X-ray images with spatial resolution 2-3 times better than from Yohkoh will show plenty of rapidly changing filamentary substructure in microflares.

Moore, Ronald L.↗

Kinetic and thermodynamic properties of a convecting plasma in a two-dimensional dipole field

Charged particle guiding center motion is considered in the magnetic field of a two-dimensional ('line') dipole on which is superimposed a small, static, perpendicular electric field. The parallel equation of motion is that of a simple harmonic oscillator for cos theta, the cosine of magnetic colatitude theta. Equations for the perpendicular electric and magnetic drifts are derived as well as their bounce-averaged forms. The latter are solved to yield a bounce-averaged guiding center trajectory, which is the same as that obtained from conversation of magnetic moment mu, longitudinal invariant J, and total (kinetic plus electrostatic) energy K. The algebraic simplicity of the trajectory equations is also manifest in the forms of the invariants. An interesting result is that guiding centers drift in such a way that they preserve the values of their equatorial pitch angles and (equivalently) mirror latitudes. The most general Maxwellian form of the equilibrium one-particle distribution function f is constructed from the invariants, and spatially varying density and pressure moments, parallel and perpendicular to the magnetic field, are identified. Much of the paper deals with the more restricted problem in which f is specified as a bi-Maxwellian over a straight line of finite length in the equatorial plane of the dipole and perpendicular to field lines. This might be thought of as specifying a cross-tail ion injection source; our formalism then describes the subsequent spatial development. The distribution away from the source is a scaled bi-Maxwellian but one that is cut off at large and small kinetic energies, which depend on position. Density and pressure components are reduced from the values they would have if the total content of individual flux tubes convected intact. The equatorial and meridional variations of density and pressure components are examined and compared systematically for the isotropic and highly anisotropic situations. There appears to be little qualitative difference due to anisotropy. An anisotropy measure is defined, and its spatial variation determined as a signature of possible MHD instability. Extreme values are found, larger than at the source, but the plasma beta in such regions is probably so low as to render the effect inconsequential energetically. Finally, the possible consequence of 'nonadia- batic' pressure profiles on electrostatic interchanges is considered, and a boundary delineating stabilizing and destabilizing regions determined.

Huang, T. S.↗

Isis 1 observations of the high-latitude ionosphere during a geomagnetic storm.

The Isis 1 satellite has made measurements of several ionospheric and related parameters, and the results of the various measurements have been compared in detail for two north transpolar passes during the geomagnetic storm of February 3, 1969. Simultaneous measurements were made of local electron and ion densities and temperatures, electron density between the satellite and the peak of the F layer, radio noise, and particle fluxes over a wide energy range extending down to 10 eV. Several features of the ionosphere (in particular, enhancements of radio noise, scale height, and plasma temperatures) appear to be due to soft-particle (100 eV to 1 keV) precipitation, which is related to magnetospheric structure as delineated by the observation of more energetic particles. The magnetosheath particles precipitating on the dayside of the polar cap are particularly effective.

Whitteker, J. H.↗

Measurements of particle emission from discharge sites in Teflon irradiated by high energy electron beams

Anomalous behavior of synchronous orbit satellites manifested by overall degradation of system performance and reduced operating life is associated with electrical discharges resulting from differential charging of the spacecraft surface by fluxes of high energy electrons. During a laboratory simulation silver-backed Teflon samples have been irradiated by electron beams having energies in the range 16-26 keV. Charged particles emitted from the resultant electrical discharges have been measured with a biased Faraday cup and retarding potential analyser. Measurements indicate the presence of two distinct fluxes of particles, the first being an early pulse (0-600ns) of high energy (about 7keV) electrons, while the second is a late pulse (1-5 microseconds) of low energy electrons (less than 1eV) and ions (70eV) leaving the discharge site as a quasi plasma. Calculations indicate an electrostatic field as the dominant accelerating mechanism for charged particles.

Hazelton, R. C.↗

Mirroring of fast solar flare electrons on a downstream corotating interaction region

We discuss an example of confinement of fast solar electrons by a discrete solar wind-interplanetary magnetic field structure on February 22, 1991. The structure is about 190,000 km in width and is clearly defined by changes in the direction of the magnetic field at the Ulysses spacecraft. This structure carries electrons moving toward the Sun as well as away from the Sun. A loss cone in the angular distribution of the fast electrons shows that mirroring, presumably magnetic, takes place downstream from the spacecraft. Following passage of this narrow structure, the return flux vanishes for 21 min after which time the mirroring resumes and persists for several hours. We identify the enhanced magnetic field region lying downstream from the Ulysses spacecraft that is responsible for the mirroring to be a corotating stream interaction region. Backstreaming suprathermal electron measurements by the Los Alamos National Laboratory plasma experiment on the Ulysses spacecraft support this interpretation.

Anderson, K. A.↗

Universal Heliophysical Processes

The physical processes in the heliospace are a direct consequence of the Sun s mass and electromagnetic emissions. There has been enormous progress in studying these processes since the dawn of the space age half a century ago. The heliospace serves as a great laboratory to study numerous physical processes, using the vast array of ground and spacebased measurements of various physical quantities. The observational capabilities collectively form the Great Observatory to make scientific investigations not envisioned by individual instrument teams. The International Heliophysical Year (IHY) program has been promoting scientific investigations on the universality of physical processes such as shocks, particle acceleration, dynamo, magnetic reconnection, magnetic flux ropes, plasma-neutral matter interactions, turbulence, and several other topics. This chapter highlights scientific deliberations on these and related topics that took place during the IAGA session on "Universal Heliophysical Processes" in Sopron, Hungary. The session featured several invited and contributed papers that focused on observations, theory and modeling of the universal heliophysical processes.

Gopalswamy, Natchimuthuk↗

Experiment S026: Ion wake measurement

Measurements of the ion-wake and electron-wake structure and other perturbations of the ambient medium produced by the Gemini spacecraft in orbit are reported. Thruster firings in the TDA-south configuration produced a decrease in the observed ion flux to the outboard ion sensor, an apparent increase in the ion flux to the inboard ion sensor, and an enhanced electron concentration to the outboard electron sensor. Visual inspection of strip-chart data was indicative that definitive wake-cone angles could be determined. It also was apparent for many cases that the electron distribution followed the ion depletion effects; this was indicative that the wake was a plasma, not an ion wake. Analysis of the data from the GATV orbits was indicative that electron and ion temperatures were higher than was estimated. The high electron temperature accounted for the sensor saturation observed during the mission. This temperature measurement was 0.3 electron volt at a 200-n. mi. altitude during daytime conditions. Spacecraft wake structure has been observed as far as 100 feet from the vehicle.

Medved, D. B.↗

Charge exchange in a planetary corona - Its effect on the distribution and escape of hydrogen

The theory for a spherical collisionless planetary corona is extended to include charge-exchange collisions between H(+) and H, which are assumed to constitute intermingled gases with different kinetic temperatures. The treatment is based on the conventional concept of a critical level (or exobase) above which the only collisions considered in the Boltzmann equation are those that resonantly exchange charge. Although the geometry treated is an oversimplification for a real planet, numerical examples are given for an idealized earth and Venus. For earth, an ion temperature of 4 times the neutral temperature, an ion density at the exobase of 14,000 per cu cm, and a plasmapause at 1.5 earth radii will raise the escape flux of H by a factor of 6. The total H above the exobase is changed by less than 1%. For Venus, conditions are examined that would account for the peculiar H distribution observed from Mariner 5. The plasma conditions required are not obviously outrageous by terrestrial standards, but the Mariner 5 ionosphere measurements did not show a high plasmapause at, say, 1.25 or 1.5 planetary radii, a fact that might argue against a charge-exchange model.

Chamberlain, J. W.↗