At least 433 records · Page 24

Graph Convolutional Network-Based Topology Embedded Deep Reinforcement Learning for Voltage Stability Control

Topological variations in power system is a common phenomenon and can impose significant challenges to traditional controllers of power system. Recent study revealed the strength of deep reinforcement learning (DRL) based approaches in power system preventive and corrective control. But topological variations are difficult to capture using classical fully connected neural network (FCN) model and has not been explicitly modeled in previous work. Hence, we develop a Graph Convolutional Network (GCN) based DRL framework to tackle topology changes in control design of power system. The GCN model exploits the graph structure of the power network and helps the DRL agent to embed the topology information during learning process. Our GCN based approach is evaluated using the IEEE-39 bus system and it outperforms the FCN-based DRL scheme in terms of training convergence and control performance considering grid topology changes.

Hossain, Ramij Raja↗

Consensus-Based Approach for Active Power Control and Reserve Estimation in Distributed PV Systems: Preprint

With the increased adoption of distributed energy resources (DER), they are expected to contribute to power system reliability services and enhance power system stability. This paper presents a distributed consensus control approach for the real-time active power reserve estimation and power management in distributed PV (photovoltaic) systems. The proposed method estimates the cumulative active power reserve from numerous PV generators using only the sparse communication network for a DER aggregator to provide active power regulation services. The real-time active power reserve estimation using the proposed approach can be used by DER aggregators to manage curtailment in distributed PV systems to maintain stipulated reserves and further to provide power system frequency regulation. Using the proposed approach, the DER aggregator only requires measurements at the feeder substation and it does not require information from individual DER units, thereby improving system resiliency. The proposed distributed consensus control method is validated on IEEE 123 testbed using PSCAD simulations.

active power reserve↗

Cyber Resilient Flexible Alternating Current Transmission Systems (XFACTS)

This report summarizes the activities conducted under the DOE-OE funded project DEOE0000897, Cyber Attack Resilient Flexible AC Systems – XFACTS. Hitachi Energy (HE), in collaboration with ABB Inc. (ABB), Bonneville Power Administration (BPA), University of Illinois at Urbana-Champaign (UIUC), Iowa State University (ISU), and University of Idaho (UI) pursued the development of a system of defense for Flexible Alternating current Transmission Systems against cyber-attacks (XFACTS). A FACTS substation enhanced with XFACTS defense mechanisms will be capable of mitigating cyberattacks especially those that seek to control electrical parameters like voltage or current and interrupt the power flow in AC lines. It empowers existing FACTS controllers and associated intelligent electronic devices to detect and mitigate malicious intents to depress system voltages, destabilize power flows, trip AC circuit breakers, corrupt currents, and voltages, even if the malicious commands and the measurements have correct syntax. The XFACTS functions utilize the physics of active power electronic systems, control and protection, electric power engineering principles, and state estimation to bring more in-depth cyber defense closer to the protected FACTS substation devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Method for controlling fiber growth in a laser heated pedestal growth system by controlling a laser power output, a pedestal feedstock rate of motion, and a draw rate

One or more embodiments relate to a method for controlling fiber growth and fiber diameter in a laser heated pedestal growth (LHPG) system so as to provide long, continuous single-crystal optical fibers of uniform diameter. The method generally provides three independent parameter feedback controls to control the molten zone height, laser power, and fiber drawing rates simultaneously in order to reduce the mismatch between instantaneous diameter changes and current diameter. The method permits the growth of fibers with non-uniform diameters along the fiber's length. The method also provides the capability to stop the LHPG system, remove the exhausted pedestal feedstock with a second pedestal feedstock, and restart the LHPG system to provide a continuous fiber.

Buric, Michael P.↗

Power System Frequency Dynamics Modeling, State Estimation, and Control using Neural Ordinary Differential Equations (NODEs) and Soft Actor-Critic (SAC) Machine Learning Approaches

With the global energy transition of the electric power system, grid control, supervision, and protection is becoming more challenging. With the increasing integration of renewable energy sources (RES), the system dynamics are changing, causing traditional power system dynamic modeling with swing equation-based modeling approaches to fail. Additionally, the converter-dominated power grid is decreasing the system inertia, making the power system more fragile to the frequency swings. This paper first investigates and compares the application of a model-based Kalman filter state estimation approach with (i) a model-free machine learning approach --- neural ordinary differential equations (NODEs) --- and (ii) a data-driven system identification (SysId) approach to model and infer critical state values of the power system frequency dynamics. Then a model predictive control (MPC) framework is compared to a model-free Soft Actor-Critic (SAC) reinforcement learning (RL) control algorithm in providing efficient fast frequency response (FFR) to the power system frequency dynamics. The approaches are compared in terms of their performance goals as well as their per-timestep computational efficiency. Furthermore, the comparative study for state estimation shows that for the model-free requirement, both NODEs and SysId can provide accurate state estimates; however, with increasing model complexity, NODEs can be a better choice for model identification. Similarly, the results from the FFR comparative study show that the SAC RL-based FFR, once trained, outperforms MPC with better control signals and faster computation time, making the SAC RL-based FFR better option for providing FFR to the power system.

97 MATHEMATICS AND COMPUTING↗

MPC4CLR (Model-Predictive-Control-for-Critical-Load-Restoration-in-Power-Distribution-Systems) [SWR-22-24]

Model predictive control (MPC) is a system or process control technique for making decisions under uncertainty via rolling look-ahead optimizations at each control step where only the current step decisions are applied, and the rest are discarded. In this work, we developed an MPC for a critical load restoration (CLR) in power distribution systems to recover system service (electricity delivery) following an extreme event-triggered substation outage. The method considers the problem of controlling distributed energy resources (DERs) of the distribution system with the objective of achieving maximum load pick up while satisfying distribution network flow and voltage constraints. A linearized optimal power flow (OPF) model is employed to represent the physics of the network. The problem formulation is augmented with a ramping (up) reserve product for the DERs to ensure improved and upward monotonic load restoration as time evolves. Simulation analysis and performance tests are performed using a modified IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage battery. The software is developed using various software packages in Julia and Python. The MPC model is implemented using the JuMP optimization language in Julia while the data analytics including renewable generation and load demand forecasts, running the MPC simulation and visualizations is performed in Python.

Eseye, Abinet Tesfaye↗

Real Power and Reactive Power Control of a Three-Phase Single-Stage-PV System and PV voltage Stability

Grid-connected photovoltaic (PV) systems with power electronic interfaces can provide both real and reactive power to meet power system needs with appropriate control algorithms. This paper presents the control algorithm design for a three-phase single-stage grid-connected PV inverter to achieve either maximum power point tracking (MPPT) or a certain amount of real power injection, as well as the voltage/var control. The switching between MPPT control mode and a certain amount of real power control mode is automatic and seamless. Without the DC-to-DC booster stage, PV DC voltage stability is an important issue in the control design especially when the PV inverter is operating at maximum power point (MPP) with voltage/var control. The PV DC voltage collapse phenomenon and its reason are discussed. The method based on dynamic correction of the PV inverter output is proposed to ensure PV DC voltage stability. Simulation results of the single-stage PV system during system disturbances and fast solar irradiation changes confirm that the proposed control algorithm for single-stage PV inverters can provide appropriate real and reactive power services and ensure PV DC voltage stability during dynamic system operation and atmospheric conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Emergency Voltage Regulation in Power Systems via Ripple-Type Control

With increasing penetrations of volatile renewable generation and cyber-physical disruptions, ensuring the safe operation of bulk power systems has become unprecedentedly challenging. Because communication and computational costs restrict centralized system dispatch to being called upon every few minutes, and because purely local schemes are shown to be insufficient, distributed controls have been advocated for handling unanticipated system conditions in real time. The applicability of distributed control schemes, however, is fundamentally limited by their need for widespread communication and model cognizance. In this context, we put forth a hybrid, low-communication, saturation-driven protocol for the coordination of control agents that are distributed over a physical system and are allowed to communicate with peers over a "hotline" communication network. Under this protocol, when agents observe a constraint violation based on local measurements, they respond locally until their control resources saturate, in which case they send a beacon for assistance to peer agents. The scheme ensures that minor violations are efficiently mitigated via fast local controls, whereas severe violations can be handled by collaboration among a relatively small set of agents. We evaluate the performance of this scheme via numerical tests on the IEEE 14-bus test feeder, where agents act upon noisy measurements under diverse scenarios of load variations and severe low-/high-voltage events.

collaboration↗

Ripple-Type Control for Enhancing Resilience of Networked Physical Systems

Distributed control agents have been advocated as an effective means for improving the resiliency of our physical infrastructures under unexpected events. Purely local control has been shown to be insufficient, centralized optimal resource allocation approaches can be slow. In this context, we put forth a hybrid low-communication saturation-driven protocol for the coordination of control agents that are distributed over a physical system and are allowed to communicate with peers over a “hotline” communication network. According to this protocol, agents act on local readings unless their control resources have been depleted, in which case they send a beacon for assistance to peer agents. Our ripple-type scheme triggers communication locally only for the agents with saturated resources and it is proved to converge. Moreover, under a monotonicity assumption on the underlying physical law coupling control outputs to inputs, the devised control is proved to converge to a configuration satisfying safe operational constraints. The assumption is shown to hold for voltage control in electric power systems and pressure control in water distribution networks. Numerical tests corroborate the efficacy of the novel scheme.

distributed control↗

Ripple-Type Control for Enhancing Resilience of Networked Physical Systems: Preprint

Distributed control agents have been advocated as an effective means for improving the resiliency of our physical in-frastructures under unexpected events. While purely local control has been shown to be insufficient, centralized optimal resource allocation approaches can be slow. In this context, we put forth a hybrid low-communication saturation-driven protocol for the coordination of control agents that are distributed over a physicalsystem and are allowed to communicate with peers over a 'hot-line' communication network. According to this protocol, agents act upon on local readings unless their control resources have been depleted, in which case they send a beacon for assistance to peer agents. Our ripple-type scheme triggers communication locally only for the agents with saturated resources, and is proved to converge. Moreover, under a monotonicity assumption on the underlying physical law coupling control outputs to inputs, the devised control is proved to converge to a configuration satisfying safe operational constraints. The assumption is shown to hold for voltage control in electric power systems and pressure control in water distribution networks. Numerical tests on both networks corroborate the efficacy of the novel scheme.

distributed control↗

Duty-Cycle Predictive Control of Quasi-Z-Source Modular Cascaded Converter Based Photovoltaic Power System

A duty-cycle predictive control is proposed for dc grid integration of front-end isolated quasi-Z-source modular cascaded converter (qZS-MCC) photovoltaic (PV) power system. The post-stage qZS half-bridge dc-dc converter deals with PV maximum power point tracking, dc grid integration, and dc-link voltage balance; whereas, the front-end isolation converters operate at a constant duty cycle of 50%. Thus, it saves control hardware resources while overcoming challenges from PV-panel voltage variations and dc-bus voltage limit. The proposed control uses the derived circuit model to predict the global active-state duty cycle for grid-connected current control and predict the shoot-through duty cycles for dc-link voltage balance, achieving a fast and accurate tracking target. The proposed control method has advantages of: i) eliminating weighting factors that exist in conventional model predictive control (MPC), ii) no sophisticated loop parameters design that exists in proportional-integral (PI) control, iii) operating at constant switching frequency that is different from the conventional MPC with variable switching frequency. Simulation and experimental tests are carried out to verify the effectiveness of the proposed control method and compare with the PI-based control system.

42 ENGINEERING↗

A Lyapunov Function Based Remedial Action Screening Tool Using Real-Time Data

This report summarizes the outcome of a research project that comprised the development of a Lyapunov function based remedial action screening tool using real-time data (L-RAS). The L-RAS is an advanced computational tool that is intended to assist system operators in making real-time redispatch decisions to preserve power grid stability. The tool relies on screening contingencies using a homotopy method based on Lyapunov functions to avoid, to the extent possible, the use of time domain simulations. This enables transient stability evaluation at real-time speed without the use of massively parallel computational resources. The project combined the following components. 1. Development of a methodology for contingency screening using a homotopy method based on Lyapunov functions and real-time data. 2. Development of a methodology for recommending remedial actions based on the screening results. 3. Development of a visualization and operator interaction interface. 4. Testing of screening tool, validation of control actions, and demonstration of project outcomes on a representative real system simulated on a Real-Time Digital Simulator (RTDS) cluster. The project was led by Michigan State University (MSU), where the theoretical models including homotopy-based screening, trajectory correction using real-time data, and remedial action were developed and implemented in the form of research-grade software. Los Alamos National Laboratory (LANL) contributed to the development of energy margin sensitivity dynamics, which constituted a part of the remedial action portfolio. Florida State University (FSU) and Southern California Edison (SCE) developed a model of the SCE system that was implemented on FSU's RTDS cluster to simulate real-time data that was streamed over the internet to MSU where the L-RAS tool was executed and remedial actions were communicated back to FSU to execute stabilizing controls on the simulated system. LCG Consulting developed the visualization and operator interaction interface, based on specifications provided by MSU. The project was performed from October 2012 to December 2016, at the end of which the L-RAS tool, as described above, was completed and demonstrated. The project resulted in the following innovations and contributions: (a) the L-RAS software prototype, tested on a simulated system, vetted by utility personnel, and potentially ready for wider testing and commercialization; (b) an RTDS-based test bed that can be used for future research in the field; (c) a suite of breakthrough theoretical contributions to the field of power system stability and control; and (d) a new tool for visualization of power system stability margins. While detailed descriptions of the development and implementation of the various project components have been provided in the quarterly reports, this final report provides an overview of the complete project, and is demonstrated using public domain test systems commonly used in the literature. The SCE system, and demonstrations thereon, are not included in this report due to Critical Energy Infrastructure Information (CEII) restrictions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Forming Frequency Shaping Control for Low-Inertia Power Systems

As power systems transit to a state of high renewable penetration, little or no presence of synchronous generators makes the prerequisite of well-regulated frequency for grid-following inverters unrealistic. Thus, there is a trend to resort to grid-forming inverters which set frequency directly. We propose a novel grid-forming frequency shaping control that is able to shape the aggregate system frequency dynamics into a first-order one with the desired steady-state frequency deviation and Rate of Change of Frequency (RoCoF) after a sudden power imbalance. The no overshoot property resulting from the first-order dynamics allows the system frequency to monotonically move towards its new steady-state without experiencing frequency Nadir, which largely improves frequency security. We prove that our grid-forming frequency-shaping control renders the system internally stable under mild assumptions. The performance of the proposed control is verified via numerical simulations on a modified Icelandic Power Network test case.

control systems↗

Control of wind turbine generators connected to power systems

A unique simulation model based on a Mode-O wind turbine is developed for simulating both speed and power control. An analytical representation for a wind turbine that employs blade pitch angle feedback control is presented, and a mathematical model is formulated. For Mode-O serving as a practical case study, results of a computer simulation of the model as applied to the problems of synchronization and dynamic stability are provided. It is shown that the speed and output of a wind turbine can be satisfactorily controlled within reasonable limits by employing the existing blade pitch control system under specified conditions. For power control, an additional excitation control is required so that the terminal voltage, output power factor, and armature current can be held within narrow limits. As a result, the variation of torque angle is limited even if speed control is not implemented simultaneously with power control. Design features of the ERDA/NASA 100-kW Mode-O wind turbine are included.

Hwang, H. H.↗

Emergency Voltage Regulation in Power Systems via Ripple-Type Control: Preprint

With increasing penetration of volatile renewable generation and cyber-physical disruptions, ensuring safe operation of bulk power systems has become unprecedentedly challenging. Since communication and computational costs restrict centralized system dispatch to be called upon every few minutes; and purely local schemes are shown to be insufficient, distributed controls have been advocated for handling unanticipated system conditions in real time. However, the applicability of distributed control schemes is fundamentally limited by their need for widespread communication and model cognizance. In this con-text, we put forth a hybrid low-communication saturation-driven protocol for the coordination of control agents that are distributed over a physical system and are allowed to communicate with peers over a ‘hotline’ communication network. Under this protocol, when agents observe a constraint violation based on local measurements, they respond locally until their control resources saturate, in which case they send a beacon for assistance to peer agents. The scheme ensures that minor violations are efficiently mitigated via fast local controls, while severe violations may be handled by a collaboration of a relatively small set of agents. We evaluate the performance of this scheme via extensive numerical tests on the IEEE 14-bus test feeder, where agents act upon noisy measurements under diverse scenarios of random load variations and severe low/high voltage events.

distributed control↗