Search NASA⌕ Search

SEARCH · Search NASA

Results for “Proton facilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Intrinsic energy and time resolution of the Jefferson Lab Hall C Neutral Particle Spectrometer

The Neutral Particle Spectrometer (NPS) is an advanced calorimeter designed to measure neutral electro- magnetic particles with high precision in energy, time, and position, under conditions of high luminosity and significant background. Integrated into the experimental setup of Hall C at Thomas Jefferson National Accelerator Facility, the NPS plays a critical role in studies of nucleon structure through exclusive and semi- inclusive reaction channels. Here, this paper presents an assessment of the detector’s performance characteristics, specifically its energy and timing resolution, derived from elastic electron–proton scattering data. We report an energy resolution between 1.2% and 1.3% in the 4.5–7.3 GeV range, and an intrinsic timing resolution better than 200 ps for energies above 500 MeV. These results serve as a reference for current and future precision measurements in hadronic physics.

Detector performance↗

Radiation Hardening – Test Capabilities (LANSCE) [Slides]

The Los Alamos Neutron Science Center (LANSCE) has exceptional facilities for research and testing of radiation effects in electronics. We have the best terrestrial neutron source for sea-level and airplane-altitude environments. We have a thermal neutron test capability at the Lujan Center and a proton beam test capability at the “Blue Room”. LANL has the programmatic mission to develop this radiation-effects program, namely space and satellite environments, high-performance computing (silent data corruption), and weapons delivery systems. We have a strong connection to industry which continues to grow.

42 ENGINEERING↗

Archway for Radiation and Micrometeorite Occurrence Resistance

The environmental conditions of the Moon require mitigation if a long-term human presence is to be achieved for extended periods of time. Radiation, micrometeoroid impacts, high-velocity debris, and thermal cycling represent threats to crew, equipment, and facilities. For decades, local regolith has been suggested as a candidate material to use in the construction of protective barriers. A thickness of roughly 3m is sufficient protection from both direct and secondary radiation from cosmic rays and solar protons; this thickness is sufficient to reduce radiation exposure even during solar flares. NASA has previously identified a need for innovations that will support lunar habitats using lightweight structures because the reduction of structural mass translates directly into additional up and down mass capability that would facilitate additional logistics capacity and increased science return for all mission phases. The development of non-pressurized primary structures that have synergy with the development of pressurized structures is also of interest. The use of indigenous or in situ materials is also a well-known and active area of research that could drastically improve the practicality of human exploration beyond low-Earth orbit. The Archway for Radiation and Micrometeorite Occurrence Resistance (ARMOR) concept is a new, multifunctional structure that acts as radiation shielding and micrometeorite impact shielding for long-duration lunar surface protection of humans and equipment. ARMOR uses a combination of native regolith and a deployed membrane jacket to yield a multifunctional structure. ARMOR is a robust and modular system that can be autonomously assembled on-site prior to the first human surface arrival. The system provides protection by holding a sufficiently thick (3 m) archshaped shell of local regolith around a central cavity. The regolith is held in shape by an arch-shaped jacket made of strong but deployable material. No regolith processing is required. During the regolith filling process, an inflatable structure under the arch supports the mass of the regolith, but once regolith filling is complete the catenary arch formed by the regolith and the jacket becomes self-supporting and the inflatable can be deflated and removed. When complete, habitat modules and equipment can be moved into the protected cavity under the arch. ARMOR is a nearterm system that would provide a reliable and robust lightweight structure technology to support large lunar habitats, drastically lower launch mass, and improve efficient volume use, reducing launch costs.

Giersch, Louis R.↗

The Need for Earth-Based Experiments to Inform Microbial Evolution on Planetary Surfaces

Introduction: Historically, the focus of planetary protection at NASA has been on unmanned, robotic missions. Such missions have paved the way for understanding how to implement planetary protection in a feasible and cost-sensitive way. However, with the introduction of crewed missions to Mars in the not-sodistant future, there is a need to better define and understand how to implement planetary protection under new circumstances, as well as understand the risk of contaminating Mars. One unavoidable fact is that microbes will go where humans go. Therefore, it is critical to understand how these microbes may (and will) impact our ability to conduct meaningful, reliable astrobiological science. Microorganisms have spent millions of years evolving to survive in extreme environments here on Earth. Already there are indications that microbes aboard the International Space Station evolve and adapt to life in low earth orbit. The microbes that are eventually taken to Mars with humans will also adapt, potentially causing harmful effects to crew and/or the planetary or astrobiological science conducted. Therefore, it is of critical interest that we evaluate and characterize the potential risks of microbial evolution on Mars. It is expected that microbes carried by humans will begin to evolve to new environments even before landing on Mars, during the several month cruise phase. Once landed, microbes will encounter different stressors within the crew habitats on Mars. During extravehicular activities, venting, or other release events, microbes will find their way out onto the Martian surface. The induced environments around crewed systems will create potentially-favorable conditions for microbes to continue evolving on Mars. Eventually, microbes may find their way beyond the close confines of the crewed area and continue evolving so as to fill new or distant niches on the Martian surface. It is challenging to replicate Martian environments here on Earth, making it nearly impossible to predict the evolutionary changes that microbes would undergo on Mars. But this work is critical. Serial passaging experiments performed by Richard Lenski on E. coli show the dramatic changes microbes can undergo even within a laboratory setting. Furthermore, experiments performed by Michael Baym also demonstrate the power of single mutations in microbial development of antibiotic resistance [3]. Long duration experiments should be performed on a suite of microbes exposed to environments likely to be experienced on the Martian surface. While simulating space environments can be challenging, facilities exist that can achieve individual and combinatorial environmental conditions to simulate space and planetary conditions. Such chambers should be employed for microbial studies. Currently, at the Marshall Space Flight Center, we have used various stressors like drying, vacuum, proton radiation, and ultraviolet light both separately and in combination, to evaluate the survival of cleanroom microbes. Shockingly, several non-spore forming isolates have demonstrated the ability to survive many extreme conditions (manuscript in preparation). These short duration exposures must be augmented with larger and more gradual studies to replicate what microbes might experience in the transition from cruise, to surface habitats, to induced surface environments, and finally true Martian environments. While no Earth-based experiment can perfectly replicate the Martian environment, nor could we test every possible microbe in simulation experimental regimes, efforts should be made to examine the evolutionary potential of the “usual suspects” seen on the ISS or in other crewed environments to begin to fill this important knowledge gap.

Chelsi D. Cassilly↗

Combined analysis of HPK 3.1 LGADs using a proton beam, beta source, and probe station towards establishing high volume quality control

The upgrades of the CMS and ATLAS experiments for the high luminosity phase of the Large Hadron Collider will employ precision timing detectors based on Low Gain Avalanche Detectors (LGADs). We present a suite of results combining measurements from the Fermilab Test Beam Facility, a beta source telescope, and a probe station, allowing full characterization of the HPK type 3.1 production of LGAD prototypes developed for these detectors. We demonstrate that the LGAD response to high energy test beam particles is accurately reproduced with a beta source. Finally, we further establish that probe station measurements of the gain implant accurately predict the particle response and operating parameters of each sensor, and conclude that the uniformity of the gain implant in this production is sufficient to produce full-sized sensors for the ATLAS and CMS timing detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Nucleon Resonance Electroexcitations at Jefferson Lab

Nucleons are the most fundamental three-body systems in Nature. During the last decade crucial progress has been achieved in the exploration of the spectrum and the structure of nucleon resonances. Studies of exclusive ?N, ?+??p, K?, and K? electroproduction off protons on the evolution of the electrocouplings with photon virtuality Q2 using the CLAS spectrometer has revealed a complex interplay between an inner core of three dressed quarks surrounded by an external meson-baryon cloud. CLAS12 is the only facility capable of extending these results on the electrocouplings into the unexplored Q2 range, spanning the domain of quark momenta where ? 50% of hadron mass is generated. The increase of the CEBAF energy and the upgrade of the CLAS12 spectrometer to measure exclusive electroproduction channels at higher luminosity and photon virtualities will offer a unique opportunity to explore how the dominant part of hadron mass and the bound three-quark structure of the resonant states emerge from QCD.

Achenbach, Patrick↗

Analysis and Grading of the Test Performance of PS Modules for the CMS Phase-2 Outer Tracker Upgrade

The Outer Tracker of the CMS experiment provides information about the trajectory of charged particles produced in proton-proton collisions at the LHC. During the High Luminosity LHC upgrade, scheduled for the late 2020s, the Outer Tracker will be replaced with new modules capable of transmitting data to the L1 Trigger. These modules are being assembled at several facilities around the world, including Fermilab, necessitating coordinated standards of module quality. Here I discuss the development of POTATO (Phase-2 Outer Tracker Analyzer of Test Outputs), a C++ software which provides a standardized procedure for analyzing and grading test results of the Outer Tracker modules. The particular focus of this poster is on the analysis and grading of the PS (pixel-strip) modules in POTATO.

Riggall, Caroline↗

Real time heat load calculation software based on EPICS for Fermilab PIP-II CM tests

Fermilab has a project to improve the proton beam energy which is called PIP-II (the 2nd Proton Improvement Plan). There is a superconducting linear accelerator, LINAC, to improve the proton beam power and the LINAC consists of 5 types of cryomodules (CM), 1 HWR CM, 2 SSR1 CM, 4 SSR2 CM, LB650 CM, and HB650 CM. The prototypes of these cryomodules are being tested at Fermilab’s CryoModule Test Facility (CMTF). Heat load measurements are an important part of the prototype CM testing. The CMTF cryogenic control system was developed based on the ACNET (Accelerator Control NETwork) for CM testing for other projects, but the PIP-II cryogenic control system will be implemented using the Experimental Physics and Industrial Control System (EPICS). As part of the prototype CM testing campaign an EPICS based control system has been implemented at CMTF. This EPICS cryogenic control system includes real time heat load calculation software utilizing the Fortran implementation of Hepak. This paper details the real time heat load calculation software developed for the prototype CM testing including the first results from the HB 650 CM.

Yoon, S. [Fermilab]↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

Wijethunga, Sajini A.K. [Fermilab] (ORCID:00000002↗

Longitudinal Solid P Longitudinal Solid Polarized Target for CL get for CLAS12 and Study of Spin AS12 and Study of Spin Structure of Nucleons

A suite of experiments measuring target-spin observables in electron-nucleon scattering (dubbed Run Group C) was conducted at Jefferson Lab's Hall B in Newport News, VA with a new polarized nuclear target known as 'APOLLO' (Ammonia POLarized LOngitudinally). This innovative target is engineered to seamlessly integrate with the advanced 12GeV CEBAF (Continuous Electron Beam Accelerator Facility) accelerator and the Hall B CLAS12 (12 GeV CEBAF Large Acceptance Spectrometer) detector array. The 'APOLLO' target harnesses the power of Dynamic Nuclear Polarization (DNP) to achieve longitudinal polarization of solid ammonia, thereby creating a net polarization in both protons (NH3) and deuterons (ND3). These samples are subjected to a 5 Tesla magnetic field produced by the CLAS12 spectrometer central solenoid, cooled to 1 K using helium evaporation, and subsequently exposed to microwave radiation at a frequency of 140 GHz. This project was made possible through a collaborative partnership between the Jefferson Lab Target Group, Old Dominion University, University of Virginia, Christopher Newport University, and the CLAS Collaboration. Integrating the APOLLO target into CLAS12 presented unique challenges because of its specific spatial and dimensional constraints. This dissertation will highlight the innovative solutions developed to address these challenges, including the creation of a new target material transport system, the incorporation of superconducting magnetic correction coils, and the development of a customized Nuclear Magnetic Resonance (NMR) system. In addition to a detailed description of the development and operation of APOLLO, and an overview of RGC, this document also describes the global data fitting of proton asymmetries in the Deep Inelastic scattering (DIS) and the Resonance regions, and it offers insights into the comprehensive analysis of target polarization data.

Pandey, Pushpa↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in super-conducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

Wijethunga, S. A.K. [Fermilab] (ORCID:000000028765↗

Real time heat load calculation software based on EPICS for Fermilab PIP-II CM tests

Fermilab has a project to improve the proton beam energy which is called PIP-II (the 2nd Proton Improvement Plan). There is a superconducting linear accelerator, LINAC, to improve the proton beam power and the LINAC consists of 5 types of cryomodules (CM), 1 HWR CM, 2 SSR1 CM, 4 SSR2 CM, LB650 CM, and HB650 CM. The prototypes of these cryomodules are being tested at Fermilab’s CryoModule Test Facility (CMTF). Heat load measurements are an important part of the prototype CM testing. The CMTF cryogenic control system was developed based on the ACNET (Accelerator Control NETwork) for CM testing for other projects, but the PIP-II cryogenic control system will be implemented using the Experimental Physics and Industrial Control System (EPICS). As part of the prototype CM testing campaign, an EPICS based control system has been implemented at CMTF. This EPICS cryogenic control system includes real-time heat load calculation software utilizing the Fortran implementation of Hepak. This paper details the real time heat load calculation software developed for the prototype CM testing including the first results from the HB650 CM.

Yoon, S. [Fermilab]↗

Quench Simulation and Validation for EIC Direct Wind Magnets

The Electron-Ion Collider (EIC), a new facility to be built in the United States at the U.S. Department of Energy’s Brookhaven National Laboratory in collaboration with Thomas Jefferson National Accelerator Facility-will be the only new particle collider in the U.S. for the next 10∼20 years. The EIC project will investigate the origin of mass and building blocks of the Universe. It will accelerate and collide beams of electrons with protons and nuclei. Unlike any collider that has ever existed before, both EIC’s particle beams will be polarized, meaning their spins will be aligned in a controlled way to allow for precision measurements. Different types of new superconducting magnets will be required near the interaction region (IR) of EIC. A 6-around-1 NbTi cable will be used for some of those new superconducting magnets. Given the relatively smaller conductors used for those direct wind magnets, the overall engineering current density will be 2–3 times higher in comparison to traditional collared superconducting magnets in other accelerator magnets. This is technically challenging and potentially represents high risks for quench protection. Here, in this paper we use different tools and methods for quench simulation for several EIC direct wind magnets. We also present results of a sensitivity study, exploring different material properties and Jc curves. This paper also discusses and validates the quench simulation results with measurement results from a small-scale serpentine magnet tested at BNL in October 2024.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hadron-argon cross-section measurements in ProtoDUNE-SP

The single-phase liquid argon ProtoDUNE detector (ProtoDUNE-SP) is located at CERN’s neutrino platform facility and serves as a prototype to validate the technology for the 10-kton fiducial mass liquid argon detectors for the DUNE experiment. ProtoDUNE-SP was exposed to a variety of test-beam particles (electrons, muons, pions, kaons, and protons) towards the end of 2018 collecting data in a broad range of momenta, from 0.3 - 7 GeV/c. The results will improve the understanding of final-state interactions in neutrino-argon cross-sections. The progress of the analyses towards the cross-section measurements on argon from the test-beam data collected at protoDUNE-SP will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multidimensional measurements of beam single-spin asymmetries in semi-inclusive deep-inelastic charged-kaon electroproduction off protons in the valence region

Measurements of beam single-spin asymmetries in semi-inclusive deep-inelastic electron scattering (SIDIS) with positively charged kaons off protons have been performed with 10.6 and 10.2 GeV incident electron beams using the CLAS12 spectrometer at Jefferson Lab. We report an analysis of the electroproduction of positively charged kaons over a large kinematic range of fractional energy, Bjorken 𝑥, transverse momentum, and photon virtualities 𝑄 2 ranging from 1 GeV 2 up to 6 GeV 2 . This is the first published multidimensionally binned CLAS12 measurement of a kaon SIDIS single-spin asymmetry in the valence quark regime. The data provide constraints on the structure function ratio $𝐹^{sin \space𝜙}_{𝐿⁢𝑈}$⁡/$𝐹_{𝑈⁢𝑈}$, where $𝐹^{sin \space𝜙}_{𝐿⁢𝑈}$ is a quantity with a leading twist of twist-3 that can reveal novel aspects of the quark-gluon correlations within the nucleon. The impact of the data on understanding the underlying reaction mechanisms and their kinematic variation is explored using theoretical models for the different contributing twist-3 parton-distribution functions (PDFs) and fragmentation functions (FFs).

form factors↗

Proton nuclear magnetic resonance (1H NMR) of flammable organic chemicals in radioactive high–level supernatant waste at the Savannah River Site (SRS)

The Savannah River Site stores approximately 36 million gallons of radioactive and hazardous waste that contains approximately 245 million curies. The waste is sent through various chemical processes to reduce its volume and to separate various components. The facility plans to replace formic acid (a chemical used to reduce soluble mercury) with glycolic acid. Recycle solution with glycolate may flow back to the tank farm, where the glycolate can generate hydrogen gas by thermal and radiolytic mechanisms. The current analytical method for detecting glycolate (ion chromatography) in supernatant requires a large dilution to reduce interference from the nitrate anions. Hydrogen nuclear magnetic resonance is an analytical method that requires less sample dilution. It takes advantage of the CH 2 group in glycolate. Liquid samples were spiked with four different levels of glycolate to build a calibration line, as it is recommended in the standard addition method. The detection and quantitation limits determined were 1 and 5 ppm, respectively, for 32 scans, which is well below the process limit of 10 ppm. In one test, 800 scans of a supernatant spiked with 1 ppm glycolate resulted in a -CH 2 peak with a signal-to-noise ratio of 36.

1H↗

LAMP Low-Energy Region Options: Workshop Report and Ranking Assessment

The LANSCE accelerator complex at Los Alamos National Laboratory provides beam to five user facilities: IPF, pRad, UCN, WNR and the Lujan Center. Each user facility receives a beam tailored to its specific requirements, including species (H+ or H- ) and beam pulse format. The capabilities and beam requirements of the LANSCE user facilities are documented elsewhere. The core components of the LANSCE accelerator complex – the beam source area, drift-tube and cavity-coupled linear accelerators – are more than 50 years old; a critical subsystem for beam delivery to the Lujan Center, the proton storage ring (PSR), is approximately 40 years old, with its last major refresh being completed in the late 1990s. The LAMP project is intended to begin a revitalization and update of the LANSCE accelerator complex, starting with the beam source region, drift-tube linac, and PSR.

43 PARTICLE ACCELERATORS↗

Heat load measurements for the PIP-II pHB650 cryomodule

This study presents a brief overview of the 1st and 2nd phases and an in-depth analysis of the 3rd phase heat load testing performed on the pHB650 (prototype High Beta 650 MHz) cryomodule at PIP2IT (PIP-II Injector Test Facility), with a focus on both the results and the methodological advancements that have improved testing efficiency and accuracy. A key challenge identified in the testing campaign is the higher-than-expected heat loads observed in the first PIP-II (Proton Improvement Plan II) prototype cryomodules (pSSR1 and pHB650) tested at PIP2IT. Elevated heat loads are concerning given the fixed capacity of the PIP-II cryoplant that is currently being installed at Fermilab. However, understanding the sources of these elevated heat loads offers a critical opportunity to implement effective heat load mitigations on upcoming PIP-II cryomodules to stay within the available capacity of the PIP-II cryoplant. The study includes a summary of test results, descriptions of measurement procedures, and key observations on parameters directly and indirectly related to heat load measurements. Direct observations include measured heat loads and the effectiveness of JT heat exchanger under varying conditions, while indirect observation analyze factors such as the temperature distribution on the two-phase pipe and relief piping under varying conditions. Thermal acoustic oscillations (TAO) were identified during testing, which was mitigated by replacing the original G10 stem with a stainless steel stem equipped with wipers for the cryomodule cooldown valve. A major innovation during pHB650 Phase 3 testing was the development of an automated Python script to streamline data acquisition, analysis, and reporting of heat load results. This script automatically retrieved data from ACNET (Accelerator Control Network), performed heat load calculations, and generated detailed reports featuring plots and tables. This advancement significantly reduced manual labor and enhanced the thoroughness of data analysis compared to earlier campaigns. The heat load test reports were promptly uploaded to the electronic logbook shortly after each test, enabling rapid feedback and collaboration between the SRF and cryogenic teams. The heat load measurements included various components: HTTS (high-temperature thermal shield), LTTS (low-temperature thermal shield), 2K isothermal and non-isothermal heat loads. Results were recorded both within the cryomodule and between the bayonet can supply and return. Measurements were conducted under different operating conditions such as "standard", "linac", and "simulated dynamic". Additionally, HTTS and LTTS heat loads were calculated in real time, allowing for the tracking of thermal stability and identification of changes during testing, both in steady-state and transient conditions. The results of this testing campaign not only provide valuable insights into the performance of the pHB650 cryomodule but also highlight best practices and lessons learned that will inform future cryomodule testing at PIP2IT. These include adopting automated tools for data analysis, refining real-time measurement capabilities, and emphasizing detailed pre-test planning. The framework established in this campaign aims to set an improved standard for cryomodule testing and heat load reporting in future cryomodule test campaigns.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗