Search NASA⌕ Search

SEARCH · Search NASA

Results for “RAMAN SCATTERING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Velocity profiles in a hot jet by simplified RELIEF

Raman Excitation + Laser Induced Electronic Fluorescence (RELIEF) is a double resonance velocimetry technique in which oxygen molecules are vibrationally excited via stimulated Raman scattering at a specific location within a flow field. After suitable time delay, typically 1-10 microseconds, the displacement of the tagged molecules is determined by laser induced fluorescence imaging. Providing support for the installation of simplified RELIEF flow tagging instrumentation at NASA LaRC was the principal goal of this research.

Source record↗

Laser-spectroscopic measurement techniques for hypersonic, turbulent wind tunnel flows

A review is given of the nature, present status, and capabilities of two laser spectroscopic methods for the simultaneous measurement of temperature, density, and their fluctuations owing to turbulence in high speed wind tunnel flows. One method is based on the two frequency excitation of nitric oxide seeded into a nitrogen flow, using tunable dye lasers. The second, more recent method relies on the excitation of oxygen in air flows using a tunable, ArF excimer laser. Signal are obtained from both the laser induced fluorescence and from Raman scattering of the same laser pulse. Measurements are demonstrated in the turbulent boundary layer of a Mach-2 channel flow.

Mckenzie, Robert L.↗

Observation of Stratospheric Ozone with NIES Lidar System in Tsukuba, Japan

Lidars are expected to play important roles in an international monitoring network of the stratosphere such as the Network for the Detection of Stratospheric Change (NDSC). The National Institute for Environmental Studies (NIES) in Tsukuba constructed an ozone lidar system in March 1988 and started observation in August 1988. The lidar system has a 2-m telescope and injection locked XeCl and XeF excimer lasers which can measure ozone profiles (15-45 km) and temperature profiles (30-80 km). From December 1991, lidar observations have been carried out in which the second Stokes line of the stimulated Raman scattering of a KrF laser has been used. Ozone profiles obtained with the NIES lidar system are compared with the data provided by the SAGE II satellite sensor. Results showed good agreement for the individual and the zonal mean profiles. Variations of ozone with various time scales at each altitude can be studied using the data obtained with the NIES ozone lidar system. Seasonal variations are easily found at 20 km, 30 km, and 35 km, which are qualitatively understood as a result of dynamical and photochemical effects. Systematic errors of ozone profiles due to the Pinatubo stratospheric aerosols have been detected using multi-wavelength observation.

Nakane, H.↗

A Comparison Between Raman Lidar and Conventional Contact Measurements of Atmospheric Temperature

Described here are the results of comparison between lidar and conventional contact measurements of the vertical temperature profile of the atmosphere. The lidar measurements are based on the method of temperature dependence of pure rotational Raman scattering of nitrogen and oxygen molecules. The presented results show that, as a whole, the motion of the lidar and conventional profiles coincide in the confidence intervals. Still there are districts in which the differences lay out of the confidence intervals. In analysis and estimation of the coincidence and the distinction in moving the profiles, we must take into account the differences between the methods for measuring the temperature profiles by lidar and contact methods, i.e. the next additional factors. The tied balloon meter gives the momentary values of the temperature in particular points of the profile, as these momentary values are the results of consequent, but not simultaneous measurements. In the case of free flying balloon, the time of measuring the lower several hundred meters is little because of high vertical velocity (about 300 m/min). This leads to an indefinite increase of the measuring error. The complete space coincidence between the lidar's and conventional profiles isn't possible. The contribution of the factors mentioned above about the error of comparison could increase because of nonstable layers in the planetary boundary layer of the atmosphere as well as by the influence of the mountains and the city situated nearby.

Mitev, V. M.↗

Efficiencies of Rotational Raman, and Rayleigh Techniques for Laser Remote Sensing of the Atmospheric Temperature

Various lidar methods have been developed for measuring the atmospheric temperature, making use of the temperature dependant characteristics of rotational Raman scattering (RRS) from nitrogen and oxygen, and Rayleigh or Rayleigh-Brillowin scattering (RS or RBS). These methods have various advantages and disadvantages as compared to each other but their potential accuracies are principal characteristics of their efficiency. No systematic attempt has been undertaken so far to compare the efficiences, in the above meaning, of different temperature lidar methods. Two RRS techniques have been compared. Here, we do such a comparison using two methods based on the detection and analysis of RS (RBS) spectra. Four methods are considered here for measuring the atmospheric temperature. One of them (Schwiesow and Lading, 1981) is based on an analysis of the RS linewidth with two Michelson interferometers (MI) in parallel. The second method (Shimisu et al., 1986) employs a high-resolution analysis of the RBS line shape. The third method (Cooney, 1972) employs the temperature dependance of the RRS spectrum envelope. The fourth method (Armstrong, 1974) makes use of a scanning Fabry-Perot interferometer (FPI) as a comb filter for processing the periodic RRS spectrum of the nitrogen. Let us denote the corresponding errors in measuring the temperature by sigma(sub MI), sigma(sub HR), sigma(sub ENV), and sigma(sub FPI). Let us also define the ratios chi(sub 1) = sigma(sub MI)/sigma(sub ENV), chi(sub 2) = sigma(sub HR)/sigma(sub ENV), and chi(sub 3) = sigma(sub FPI)/sigma(sub ENV) interpreted as relative errors with respect to sigma(sub ENV).

Ivanova, I. D.↗

Multiple Stokes wavelength generation in H2, D2, and CH4 for lidar aerosol measurements

Experimental results are reported of multiple Stokes generation of a frequency-doubled Nd:YAG laser in H2, D2, and CH4 in a focusing geometry. The energies at four Stokes orders were measured as functions of pump energy and gas pressure. The characteristics of the Stokes radiation generated in these gases are compared for optical production of multiple wavelengths. The competition between Raman components is analyzed in terms of cascade Raman scattering and four-wave mixing. The results indicate the possibility of using these generation processes for atmospheric aerosol measurements by means of multiwavelength lidar systems. Also, this study distinguishes between the gases, as regards the tendency to produce several wavelengths (H2,D2) versus the preference to produce mainly first Stokes radiation (CH4).

Chu, Zhiping↗

Aerosol-induced laser breakdown thresholds - Effect of resonant particles

Laser intensity thresholds for the onset of stimulated Raman scattering and the breakdown in resonant micron-sized droplets are reduced to below those for nonresonant droplets by a factor of about 3. This reduction is most likely caused by the enhancement of electromagnetic energy (photon) densities within the droplets over and above that in nonresonant droplets. The magnitude of the threshold reduction for breakdown is consistent with the assertion that: (1) input (pump) wavelength resonances that initiate plasma have cavity Qs of about 10 exp 4; and (2) finite regions of high-electromagnetic-energy density within the droplet, with dimensions of the order of the Debye length, are required to initiate plasma.

Pinnick, R. G.↗

A high-pressure van der Waals compound in solid nitrogen-helium mixtures

A detailed diamond anvil-cell study using synchrotron X-ray diffraction, Raman scattering, and optical microscopy has been conducted for the He-N system, with a view to the weakly-bound van der Waals molecule interactions that can be formed in the gas phase. High pressure is found to stabilize the formation of a stoichiometric, solid van der Waals compound of He(N2)11 composition which may exemplify a novel class of compounds found at high pressures in the interiors of the outer planets and their satellites.

Vos, W. L.↗

Raman lidar measurements of Pinatubo aerosols over southeastern Kansas during November-December 1991

Raman lidar measurements over southeastern Kansas of stratospheric aerosols produced by the June 1991 eruptions of Mt. Pinatubo were made on 10 nights during November and December 1991. Both aerosol backscattering and extinction profiles were derived simultaneously from the lidar data since this system detects Raman scattering from nitrogen and oxygen as well as the backscattered light from aerosols and molecules. Aerosols scattering ratios greater than 3(at 351 nm) were measured on several nights. Peak aerosol concentrations were located between 19-22 km and varied significantly from night to night. Aerosol extinction/backscatter ratios computed from the lidar data and averaged over the altitude region of enhanced aerosol scattering between 15-25 km varied between 18-28 sr. Mie computations show these values to be consistent with scattering by aerosol particles with mode radii between 0.3 to 0.5 micron and that the ratios would increase to 40-65 sr at 694 nm. Aerosol optical thicknesses derived from the lidar extinction measurements at 351 nm varied between 0.04 and 0.06.

Ferrare, R. A.↗

An assumed joint-Beta PDF approach for supersonic turbulent combustion

In a recent experiment, Cheng et al. (1991) used ultraviolet spontaneous vibrational Raman scattering and laser-induced predissociative fluorescence techniques for simultaneous measurements of temperature and concentrations of O2, H2, H2O, OH, and N2 (and their rms) in supersonic turbulent reacting shear layers. Because present computational techniques are not suited for prediction of all of the above measurements, a new approach has been developed and is being used to predict all relevant flow properties and their rms (where appropriate). The approach explores the use of a joint-Beta PDF for concentrations. It was found that the general expression of this PDF was impractical because of decoding problems resulting from determining the various parameters of the PDF. Thus, a special case of this general expression was considered. Calculations using this simplified version of the joint-Beta PDF were not consistent with the available data from the experiment.

Baurle, R. A.↗

Measurements of density, temperature, and their fluctuations in turbulent supersonic flow using UV laser spectroscopy

Nonintrusive measurements of density, temperature, and their turbulent fluctuation levels were obtained in the boundary layer of an unseeded, Mach 2 wind tunnel flow. The spectroscopic technique that was used to make the measurements is based on the combination of laser-induced oxygen fluorescence and Raman scattering by oxygen and nitrogen from the same laser pulse. Results from this demonstration experiment are compared with previous measurements obtained in the same facility using conventional probes and an earlier spectroscopic technique. Densities and temperatures measured with the current technique agree with the previous surveys to within 3 percent and 2 percent, respectively. The fluctuation amplitudes for both variables agree with the measurements obtained using the earlier spectroscopic technique and show evidence of an unsteady, weak shock wave that perturbs the boundary layer.

Fletcher, Douglas G.↗

Single-pulse measurement of density and temperature in a turbulent, supersonic flow using UV laser spectroscopy

Nonintrusive measurements of density and temperature and their turbulent fluctuation levels have been obtained in the boundary layer of an unseeded, Mach 2 wind tunnel flow. The spectroscopic technique that was used to make the measurements is based on the combination of laser-induced oxygen fluorescence and Raman scattering by oxygen and nitrogen from the same laser pulse. Results from this demonstration experiment compare favorably with previous measurements obtained in the same facility from conventional probes and an earlier spectroscopic technique.

Fletcher, D. G.↗

Simultaneous temperature and multispecies measurement in a lifted hydrogen diffusion flame

UV spontaneous vibrational Raman scattering and laser-induced predissociative fluorescence (LIPF) techniques are combined and applied to a lifted hydrogen jet diffusion flame. Simultaneous, temporally and spatially resolved point measurements of temperature, major species concentrations (H2, O2, N2, H2O), and absolute hydroxyl radical concentration (OH) are obtained with a 'single' excimer laser for the first time. For OH measurements, the use of LIPF makes quenching corrections unnecessary. Results demonstrate that fuel and oxidizer are in a rich, premixed, and unignited condition in the center core of the lifted flame base. In the lifted zone, combustion occurs in an intermittent annular turbulent flame brush and strong finite-rate chemistry effects result in nonequilibrium values of temperature, major species, and OH radicals. Downstream in the slow three-body recombination zone, the major species concentrations are in partial equilibrium, the OH concentrations are in superequilibrium, and the temperatures are in subequilibrium. Far downstream in the flame, equilibrium values of temperature, OH radical, and major species are found.

Cheng, T. S.↗

Observation of a two-vibron bound-to-unbound transition in solid deuterium at high pressure

We have observed a two-vibron bound-to-unbound transition in solid D2 by Raman scattering at a pressure of 34(2) GPa. We investigated the transition by increasing the vibron bandwidth, through the application of pressure, until it dominated the intramolecular anharmonicity. We present an analysis of a simple Hamiltonian that gives the experimental bivibron binding energy and the critical bandwidth-to-anharmonicity ratio. Our results indicate that while the vibron bandwidth increases markedly with pressure, the anharmonicity remains constant.

Eggert, Jon H.↗

Monte Carlo and experimental studies of nozzle flow in a low-power hydrogen arcjet

The flow in the nozzle of a small hydrogen arcjet intended for low-thrust propulsion is studied without arc ignition using numerical and experimental techniques. The flow conditions in the thruster indicate that low-density nonequilibrium effects will significantly influence the flow. Therefore, the numerical analysis is undertaken using a Monte Carlo approach. The experimental studies employ laser Raman scattering. Comparisons of the measured and computed results are made for total number density, rotational temperature, and for the number density of the first rotational level. The numerical results are found to be quite sensitive to the rotational relaxation rate, and a strong degree of thermal nonequilibrium is observed at the exit plane of the nozzle. Successful comparisons between experiment and analysis permit estimation of the rotational relaxation rate for hydrogen.

Boyd, Iain D.↗

Research activity at the shock tube facility at NASA Ames

The general design and operating conditions of NASA Ames's electric arc drive shock tube facility are described, and the measurements conducted at the facility to support the development of a theoretical model of the effects of chemical nonequilibrium over a hypersonic vehicle are summarized. In particular, attention is given to the results of measurements at a shock velocity of 6.20 km/s in 1 Torr nitrogen and measurements at a shock velocity of 10.2 km/s in 0.1 Torr air. The discussion covers reaction rate measurement, the use of holographic interferometry, and measurements of vibrational populations using Raman scattering.

Sharma, Surendra P.↗

Local measurement of temperatures and concentrations: A review for hypersonic flows

The quality of reentry simulation for Shuttle, HERMES, Sanger, and NASP systematically suffers from the strong non-equilibrium of rotational and vibrational temperature due to the rapid acceleration of the test gas in the nozzle. Therefore the determination of temperatures is necessary and, if possible, preferable by a non-intrusive technique. The specific interests of this review are optical techniques such as electron beam fluorescence, laser-induced fluorescence, and coherent anti-Stokes Raman scattering. The capabilities available for local measurements with temporal resolution and quantitative accuracy are discussed for velocity, temperature, density, species concentrations, and fluctuations due to turbulence. The applicability of these methods of measurement is presented and discussed for the coming topic in aerothermodynamics: experimental techniques of hot gases in high enthalpy flows.

Dankert, C.↗

Feasibility study: Monodisperse polymer particles containing laser-excitable dyes

The optical properties associated with small particles, which include aerosols, hydrosols and solid microspheres have an impact on several areas of science and engineering. Since the advent of high-speed computers and lasers, the interaction of light with matter in the form of small particles with a discontinuous optical boundary relative to the surroundings has been much better understood. Various nonlinear optical effects have been observed involving interaction of a laser beam with both solid microspheres and liquid microdroplets. These include observation of second and third harmonic generation, four wave mixing, optical visibility, two photon absorption, observation of stimulated emission and lasing, and Stimulated Raman Scattering. Many of these effects are observed with laser intensities which are orders of magnitude less than that required by threshold condition for interactions in macroscopic bulk medium. The primary reason for this is twofold. The front surface of the microsphere acts as a thick lens to enhance the internal intensity of the input laser radiation, and the spherical shape of the droplet acts as an optical cavity to provide feedback at specific wavelengths corresponding to the whispering gallery modes or the morphology dependent resonances (MDR's). The most interesting and significant recent finding in this field is undoubtedly the existence of resonance peaks in linear and nonlinear optical spectra. Such resonance peaks are only dependent on the particle morphology, which means the size, shape and refractive index of the particle. Because of the simultaneous presence of these resonances, they have been referred to by many names, including structural resonances, whispering modes or whispering gallery modes, creeping waves, circumferential waves, surfaces modes, and virtual modes. All of these names refer to the same phenomena, i.e. morphology dependent resonances (MDR's) which has already been described and predicted precisely by electromagnetic theory and Loentz-Mie theory since 1908. MDR's can become important when the particle size (radius a) approaches and exceeds the wavelength of the electromagnetic wave (lambda) and the refractive index of the particle is greater than that of the surrounding medium. Such resonances are easiest to observe from a single particle with high symmetry, such as a sphere, spheroid, or cylinder. MDR's correspond to solutions of the characteristic equations of the electromagnetic fields in the presence of a sphere.

Venkateswarlu, Putcha↗