Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Electrode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Charge storage in β-FeSi{sub 2} nanoparticles

We report on the observation of a surprisingly high specific capacitance of β-FeSi{sub 2} nanoparticle layers. Lateral, interdigitated capacitor structures were fabricated on thermally grown silicon dioxide and covered with β-FeSi{sub 2} particles by drop or spin casting. The β-FeSi{sub 2}-nanoparticles, with crystallite sizes in the range of 10–30 nm, were fabricated by gas phase synthesis in a hot wall reactor. Compared to the bare electrodes, the nanoparticle-coated samples exhibit a 3–4 orders of magnitude increased capacitance. Time-resolved current voltage measurements show that for short times (seconds to minutes), the material is capable of storing up to 1 As/g at voltages of around 1 V. The devices are robust and exhibit long-term stability under ambient conditions. The specific capacitance is highest for a saturated relative humidity, while for a relative humidity below 40% the capacitance is almost indistinguishable from a nanoparticle-free reference sample. The devices work without the need of a fluid phase, the charge storing material is abundant and cost effective, and the sample design is easy to fabricate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Best Practices in PEC Water Splitting: How to Reliably Measure Solar-to-Hydrogen Efficiency of Photoelectrodes

Photoelectrochemical (PEC) water splitting, which utilizes sunlight and water to produce hydrogen fuel, is potentially one of the most sustainable routes to clean energy. One challenge to success is that, to date, similar materials and devices measured in different labs or by different operators lead to quantitatively different results, due to the lack of accepted standard operating procedures and established protocols for PEC efficiency testing. With the aim of disseminating good practices within the PEC community, we provide a vetted protocol that describes how to prepare integrated components and accurately measure their solar-to-hydrogen (STH) efficiency (η STH ). This protocol provides details on electrode fabrication, η STH test device assembly, light source calibration, hydrogen evolution measurement, and initial material qualification by photocurrent measurements under monochromatic and broadband illumination. Common pitfalls in translating experimental results from any lab to an accurate STH efficiency under an AM1.5G reference spectrum are discussed. A III–V tandem photocathode is used to exemplify the process, though with small modifications, the protocol can be applied to photoanodes as well. Dissemination of PEC best practices will help those approaching the field and provide guidance for comparing the results obtained at different lab sites by different groups.

08 HYDROGEN↗

Printed Electrochemical Sensor for Quantifying Bone Density Loss in Microgravity

Printed electrochemical biosensors have been developed for astronaut point-of-care testing. Our fabrication approach is complimentary with in-space manufacturing for an on-demand and hands-free fabrication process. These sensors are developed using a combination of thin film materials printing and 3D printing and are comprised of carbon nanotube, gold nanoparticle, silver nanoparticle and dielectric inks to make traditional electrochemical sensor devices. Initial prototyped printed electrochemical sensors demonstrate good electrochemical performance while also displaying low batch to batch variability. Here we report the development of a printed sensor to monitor bone turnover. The absence of load bearing forces experienced in microgravity causes a reduction of overall bone mass and results in the development of space osteopenia/osteoporosis.(1,2) Our approach to identify space osteopenia/osteoporosis is to monitor the change in bone mass indirectly through an excreted biomarker of bone remodeling, amino-terminal collagen crosslinks (NTX). Antibodies specific to NTX are added to the sensor’s electrode ink and applied during the manufacturing process. NTX is measured from a urine sample by changes in voltammetry and electrochemical impedance as it binds to the antibody modified electrode surface. The measurement is rapid, quantitative and requires only small handheld electronics to perform the measurement. By this process, ground and flight physicians will receive frequent and real-time insight into the development of space osteopenia/osteoporosis to guide appropriate countermeasures. REFERENCES [1] Nabavi, N. et al (2011) Bone 49, 965-974. [2] Tamma, R. et al (2009) FASEB J 23, 2549-2554.

in-space manufacturing↗

Redox Potential Measurements of Cr(II)/Cr Ni(II)/Ni and Mg(II)/Mg in Molten MgCl 2 –KCl–NaCl Mixture

The redox potential of Ni(II)/Ni, Cr(II)/Cr, and Mg(II)/Mg in MgCl 2 –KCl–NaCl (Magnak chloride) were studied utilizing chronopotentiometry (CP) method in a three-electrode electrochemical cell. Four different CrCl 2 concentrations from 873 K to 1073 K, three NiCl 2 concentrations from 773 K to 1073 K, and two MgCl 2 concentrations from 823 K to 1073 K have been measured. The activity coefficients were calculated referring to a supercooled potential accordingly. The empirical equation of formal potential will be of great significance for the fundamental thermodynamic prediction in high-temperature Magnak chloride systems where corrosion product impurities are present.

14 SOLAR ENERGY↗

Building High-Energy Silicon-Containing Batteries Using Off-The-Shelf Materials

The technology of silicon anodes appears to be reaching maturity, with high-energy Si cells already in pilot-scale production. However, the performance of these systems can be difficult to replicate in academic settings, making it challenging to translate research findings into solutions that can be implemented by the battery industry. Part of this difficulty arises from the lack of access to engineered Si particles and anodes, as electrode formulations and the materials themselves have become valuable intellectual property for emerging companies. Here, we summarize the efforts by Argonne’s Cell Analysis, Modeling, and Prototyping (CAMP) Facility in developing Si-based prototypes made entirely from commercially available materials. We describe the many challenges we encountered when testing high-loading electrodes (>5 mAh cm −2 ) and discuss strategies to mitigate them. With the right electrode and electrolyte design, we show that our pouch cells containing ≥ 70 wt% SiO x can achieve 600–1,000 cycles at C/3 and meet projected energy targets of 700 Wh L −1 and 350 Wh kg −1 . These results provide a practical reference for research teams seeking to advance silicon-anode development using accessible materials.

25 ENERGY STORAGE↗

Review of the High Performance Antiproton Trap (HiPAT) Experiment at the Marshall Space Flight Center

The significant energy density of matter-antimatter annihilation is attractive to the designers of future space propulsion systems, with the potential to offer a highly compact source of power. Many propulsion concepts exist that could take advantage of matter-antimatter reactions, and current antiproton production rates are sufficient to support basic proof-of-principle evaluation of technology associated with antimatter- derived propulsion. One enabling technology for such experiments is portable storage of low energy antiprotons, allowing antiprotons to be trapped, stored, and transported for use at an experimental facility. To address this need, the Marshall Space Flight Center's Propulsion Research Center is developing a storage system referred to as the High Performance Antiproton Trap (HiPAT) with a design goal of containing 10(exp 12) particles for up to 18 days. The HiPAT makes use of an electromagnetic system (Penning- Malmberg design) consisting of a 4 Telsa superconductor, high voltage electrode structure, radio frequency (RF) network, and ultra high vacuum system. To evaluate the system normal matter sources (both electron guns and ion sources) are used to generate charged particles. The electron beams ionize gas within the trapping region producing ions in situ, whereas the ion sources produce the particles external to the trapping region and required dynamic capture. A wide range of experiments has been performed examining factors such as ion storage lifetimes, effect of RF energy on storage lifetime, and ability to routinely perform dynamic ion capture. Current efforts have been focused on improving the FW rotating wall system to permit longer storage times and non-destructive diagnostics of stored ions. Typical particle detection is performed by extracting trapped ions from HiPAT and destructively colliding them with a micro-channel plate detector (providing number and energy information). This improved RF system has been used to detect various plasma modes for both electron and ion plasmas in the two traps at MSFC, including axial, cyclotron, and diocotron modes. New diagnostics are also being added to HiPAT to measure the axial density distribution of the trapped cloud to match measured RF plasma modes to plasma conditions.

Pearson, J. B.↗

Reduction of surface roughness and Neel coupling in perpendicular magnetic tunnel junctions with L1{sub 0}-FePt electrodes by plasma treatments

The plasma treatment with O{sub 2}/Ar mixture was applied to reduce the surface roughness of the L1{sub 0}-FePt electrode in perpendicular magnetic tunnel junctions. The surface roughness (R{sub rms}) of the L1{sub 0}-FePt layer was decreased from 1.2 nm at the as-deposited state to 0.52 nm after the plasma treatment with the ratio of O{sub 2} to Ar equal to 0.5. The low surface roughness accompanying the formation of an oxide layer led to magnetic decoupling between free and reference layers after the plasma treatment on the surface of FePt layer. The existence of the oxide layer was confirmed by using transmission electron microscopy and x-ray photoelectron spectroscopy. The interfacial Pt-oxide layer plays a significant role in the magnetic decoupling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling particle-induced electron emission in a simplified plasma Test Cell

Particle-induced electron emission (PIE) is modeled in a simplified, well-characterized plasma Test Cell operated at UCLA. In order for PIE to be a useful model in this environment, its governing equations are first reduced to lower-order models which can be implemented in a direct simulation Monte Carlo and Particle-in-Cell framework. These reduced-order models are described in full and presented as semi-empirical models. The models are implemented to analyze the interaction of low- and high-energy ({approx}1-2 keV) xenon ions and atoms with the stainless steel electrodes of the Test Cell in order to gain insight into the emission and transport of secondary electrons. Furthermore, there is a lack of data for xenon-stainless steel atom- and ion-surface interactions for similar environments. Using experimental data as a reference, both total yields and emitted electron energy distribution functions can be deduced by observing sensitivities of current collection results to these numerical models and their parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved Accelerated Stress Tests Based on Fuel Cell Vehicle Data

UTC will led a top-tier team of industry and national laboratory participants to update and improve DOE’s Accelerated Stress Tests (AST’s) for hydrogen fuel cells. This in-depth investigation will focused on critical fuel cell components (e.g. membrane electrode assemblies - MEA) whose durability represented barriers for widespread commercialization of hydrogen fuel cell technology. UTC had access to MEA materials that had accrued significant load time under real-world conditions in PureMotion® 120 power plant used in transit buses. These materials are referred to as end-of-life (EOL) components in the rest of this document. Advanced characterization techniques were used to evaluate degradation mode progress using these critical cell components extracted from both bus power plants and corresponding materials tested using the DOE AST’s. These techniques were applied to samples at beginning-of-life (BOL) to serve as a baseline. These comparisons advised the progress of the various failure modes that these critical components were subjected to, such as membrane degradation, catalyst support corrosion, platinum group metal dissolution, and others. Gaps in the existing ASTs predicted the degradation observed in the field in terms of these modes were outlined. Using the gaps, new AST’s were recommended and tested to better reflect the degradation modes seen in field operation. Also, BOL components were degraded in a test vehicle at UTC designed to accelerate the bus field operation.

08 HYDROGEN↗

Decay curve analysis for data error quantification in time-domain induced polarization imaging

In recent years, the time-domain induced polarization (TDIP) imaging technique has emerged as a suitable method for the characterization and the monitoring of hydrogeologic and biogeochemical processes. However, one of the major challenges refers to the resolution of the electrical images. Hence, various studies have stressed the importance of data processing, error characterization, and the deployment of adequate inversion schemes. A widely accepted method to assess data error in electrical imaging relies on the analysis of the discrepancy between normal and reciprocal measurements. Nevertheless, the collection of reciprocals doubles the acquisition time and is only viable for a limited subset of commonly used electrode configurations (e.g., dipole-dipole [DD]). To overcome these limitations, we have developed a new methodology to quantify the data error in TDIP imaging, which is entirely based on the analysis of the recorded IP decay curve and does not require recollection of data (e.g., reciprocals). The first two steps of the methodology assess the general characteristics of the decay curves and the spatial consistency of the measurements for the detection and removal of outliers. In the third and fourth steps, we quantify the deviation of the measured decay curves from a smooth model for the estimation of random error of the total chargeability and transfer resistance measurement. The error models and imaging results obtained from this methodology - in the following referred to as "decay curve analysis" - are compared with those obtained following a conventional normal-reciprocal analysis revealing consistent results. As a result, we determine the applicability of our methodology with real field data collected at the floodplain scale (approximately 12 ha) using multiple gradient and DD configurations.

58 GEOSCIENCES↗

Wafer-scale quasi-layered tungstate-doped polypyrrole film with high volumetric capacitance

Layered materials are particularly attractive for supercapacitors because of their unique physical, electrical and chemical properties. In this work, we demonstrate a facile and scalable electrochemical deposition method for wafer-scale synthesis of quasi-layered tungstate-doped polypyrrole films (named TALPy) with controllable thickness and size. The as-prepared TALPy film exhibits a high gravimetric density and excellent volumetric capacitance, exceeding many high-performing carbon- and polymer-based film electrodes. Based on combined results of ex-situ X-ray diffraction (XRD), Raman and X-ray photoelectron spectroscopy (XPS), it is determined that TALPy stores charge through an ion intercalation process accompanied by change in oxidation states of polypyrrole backbone, which is referred as intercalation pseudocapacitance. All these results suggest the great promise of electrochemical deposition as a scalable and controllable bottom-up approach for synthesizing quasi-layered conductive organic-inorganic hybrid films for electrochemical energy storage applications with high volumetric performance.

36 MATERIALS SCIENCE↗

SOMAFOAM: An OpenFOAM based solver for continuum simulations of low-temperature plasmas

Here, we report the development of SOMAFOAM, a finite volume framework for performing continuum simulations of low-temperature plasmas. The primary goal of this work is to discuss the features of SOMAFOAM along with representative results provided as examples for a range of operating conditions and geometries. This includes plasma and plasma–dielectric systems operating in direct current, radio frequency, and microwave regimes from pressures as low as 100 mTorr to atmospheric pressure. The code has several useful features including the ability to run massively parallel simulations using arbitrary geometries, structured/unstructured meshes, choice of models such as drift–diffusion/full-momentum at runtime, and species-dependent timesteps to name a few. The verification/validation studies presented include comparison with previously published continuum simulations (low-pressure direct current and radio frequency plasma), with experiments (Gaseous Electronics Conference Reference Cell and microwave microplasma ignited in a split ring resonator), and previously published kinetic simulations (low-pressure radio frequency plasma). Other examples provided include a direct current atmospheric pressure microplasma bounded by dielectric sidewalls and a helium–nitrogen plasma ignited using a needle electrode facing a dielectric. The performance of the code is also discussed with serial and distributed memory parallel runs demonstrated up to 512 cores. The design and implementation of the code in a modular object-oriented framework allows for easy extension and seamless coupling with other codes and can be expected to play an important role in both academia and industry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantifying the Temperature Dependence of the Multi-Species, Multi-Reaction Model. Part 1: Parameterization for a Meso-Carbon Micro-Bead Graphite

In this work, the temperature impact on the Multi-Species, Multi-Reaction (MSMR) model is studied. This is accomplished by acquiring data from slow rate lithiation and delithiation of a meso-carbon micro-bead (MCMB) graphite. The MSMR model is used to simulate linear-sweep voltammetry data of a porous electrode composed of graphite, and because the electrode is close to a state of dynamic equilibrium, the peaks in the differential voltage spectroscopy plot can be analyzed. Through this analysis, the temperature impact on the total fraction of available host sites in a particular MSMR gallery (X j ), the impact on the reference potential (U° j ), and the impact on the parameter detailing the deviation from Nernstian behavior ( ω j ) can be found. This is the first time the temperature dependence of the MSMR parameters have been experimentally analyzed. In Part 2, the impact of the temperature dependence of the MSMR parameters on the entropy coefficient of an intercalation material will be studied.

Paul, Abigail (ORCID:0000000172892069)↗

A simple novel device for air sampling by electrokinetic capture

A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrode assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.

47 OTHER INSTRUMENTATION↗

Using in situ and operando methods to characterize phase changes in charged lithium nickel cobalt aluminum oxide cathode materials

Lithium ion batteries have been extensively explored in recent decades in order to improve their electrochemical performance, address safety concerns, and reduce costs in larger-scale applications. Electrode materials are key components which govern the properties of the battery at the system level. Cathode materials are of particular importance as they are a limiting factor for achieving high energy density. Lithium nickel cobalt aluminum oxide (LiNi 0.8 Co 0.15 Al 0.05 O 2 , referred to subsequently as NCA) is one of successful cathode materials since it can deliver higher capacity than other cathode materials such as lithium cobalt oxide or lithium iron phosphate. However, structural instabilities that occur NCA during charging or at high temperatures is believed to be the primary reason for performance degradation as well as a possible safety threat. Furthermore, understanding the structural evolution that occurs in NCA is of importance to acquire fundamental insights for taking full advantage of the high capacity of NCA materials. Beyond static information, in situ and operando characterization approaches allow us to observe structural changes under external stimulus or in a working condition, providing a deeper understanding of the routes by which structure evolve. In this review, we will describe the use of both in situ and operando characterization performed with both synchrotron X-ray based techniques and advanced electron microscopy, as the combination of these techniques have been shown to be particularly effective at providing structural information at complementary length scales.

25 ENERGY STORAGE↗

SU-F-T-461: Dosimetric Evaluation of Indigenous Farmer Type Chamber FAR65- GB for Reference Dosimetry of FFF MV Photon Beam

Purpose: Indigenous Farmer type chamber FAR 65 GB is a reference class 0.6 cc ion chamber. It can be used for dosimetric evaluation of photon and high energy electron beams. We studied dosimetric characteristics of the chamber for 6MV and 10MV Flattening filter free FFF photon beams available on trueBEAM STx Linac. Methods: The study was carried out on trueBEAM STx Linac having 6 and 10 MV FFF photon beam with maximum dose rate 1400 and 2400 MU per min respectively. The dosimetric device to be evaluated is Rosalina Instruments FAR 65-GB Ion Chamber with active volume 0.65 cc, total active length 23.1cm, inner diameter of cylinder 6.2mm, wall thickness 0.4mm, inner electrode diameter 1mm. Inner and outer electrodes are made from Aluminium 2.7 gm per cc and graphite 1.82 gm per cc respectively. The ion chamber was placed along central axis of beam at 10cm depth and irradiated for 10cm × 10cm field size at SAD of 100 cm in plastic phantom. We studied Precision, Dose Linearity, Dose Rate dependence, directional dependence, Recombination effect. Recombination effect was determined using standard two-voltage method. Results: 1. Measurements were reproducible std deviation of 0.0105 and type A uncertainty 0.003265 under same set of reference conditions 2. Chamber exhibit dose linearity over a wider dose range. 3. Chamber shows dose rate independence for all available dose rate range. 4. Response of chamber with the angle of incidence of radiation is constant. 5. Recombination correction factors were 1.01848 and 1.02537 for dose rate 1400 and 2400 MU per min resp. Conclusion: Our study reveals that the chamber is prone to saturation effect at dose rate of 2400 MU per min. FAR 65-GB can be used for reference dosimetry of FFF MV photon beam with proper calculation of recombination effect.

60 APPLIED LIFE SCIENCES↗

Calculations of the pH-Dependent Onset Potential for CO Electrooxidation on Au(111)

CO electrooxidation on the Au(111) surface exhibits an onset potential that depends strongly on the pH of the electrolyte. In alkaline solution, the onset potential for CO electrooxidation is found, experimentally, to be 0.5 V lower than in acidic media on the reversible hydrogen electrode scale. This phenomenon is explained here with density functional theory which is used to calculate adsorbate binding energies including the electric double layer of the Au(111)/aqueous interface. Our model consists of a charged Au(111) slab and implicit solvation for the electrolyte. The double reference method is used to determine the potential-dependent CO electrooxidation reaction energetics. A microkinetic model, based upon the calculated reaction energetics, confi rms the lower onset potential in alkaline media. Our results show that there are three factors contributing to the lower onset potential in base: (1) stronger CO adsorption, (2) attraction between adsorbed CO and OH - , and (3) the high concentration of OH - in base.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding the Role of Zinc Hydroxide Sulfate and its Analogues in Mildly Acidic Aqueous Zinc Batteries: A Review

Abstract Mildly acidic aqueous zinc batteries (AZBs) have attracted tremendous attention for grid storage applications with the expectation to tackle the issues of Li‐ion batteries on high cost and poor safety. However, the performance, particularly energy density and cycle stability of AZBs are still unsatisfactory when compared with LIBs. To help the development of AZBs, a lot of effort have been made to understand the battery reaction mechanisms and precedent microscopic and spectroscopic analyses have shown flake‐like large particles of zinc hydroxide sulfate (ZHS) and its analogues formed on the surfaces of cathodes and anodes in sulfate and other electrolyte systems during cycling. However, because of the complexity of the thermodynamics and kinetics of aqueous reactions to understand different battery conditions, controversies still exist. This article will review the roles of ZHS discussed in recent representative references aiming to shine light on the fundamental mechanisms of AZBs and pave ways to further improve the battery performance.

25 ENERGY STORAGE↗