Search NASA⌕ Search

SEARCH · Search NASA

Results for “Regression model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Assessment of the Uniqueness of Wind Tunnel Strain-Gage Balance Load Predictions

A new test was developed to assess the uniqueness of wind tunnel strain-gage balance load predictions that are obtained from regression models of calibration data. The test helps balance users to gain confidence in load predictions of non-traditional balance designs. It also makes it possible to better evaluate load predictions of traditional balances that are not used as originally intended. The test works for both the Iterative and Non-Iterative Methods that are used in the aerospace testing community for the prediction of balance loads. It is based on the hypothesis that the total number of independently applied balance load components must always match the total number of independently measured bridge outputs or bridge output combinations. This hypothesis is supported by a control volume analysis of the inputs and outputs of a strain-gage balance. It is concluded from the control volume analysis that the loads and bridge outputs of a balance calibration data set must separately be tested for linear independence because it cannot always be guaranteed that a linearly independent load component set will result in linearly independent bridge output measurements. Simple linear math models for the loads and bridge outputs in combination with the variance inflation factor are used to test for linear independence. A highly unique and reversible mapping between the applied load component set and the measured bridge output set is guaranteed to exist if the maximum variance inflation factor of both sets is less than the literature recommended threshold of five. Data from the calibration of a six{component force balance is used to illustrate the application of the new test to real-world data.

strain-gage balance↗

Relationship Between Carbon Dioxide Levels and Reported Congestion and Headaches on the International Space Station

Congestion is commonly reported during spaceflight, and most crewmembers have reported using medications for congestion during International Space Station (ISS) missions. Although congestion has been attributed to fluid shifts during spaceflight, fluid status reaches equilibrium during the first week after launch while congestion continues to be reported throughout long duration missions. Congestion complaints have anecdotally been reported in relation to ISS CO2 levels; this evaluation was undertaken to determine whether or not an association exists. METHODS: Reported headaches, congestion symptoms, and CO2 levels were obtained for ISS expeditions 2-31, and time-weighted means and single-point maxima were determined for 24-hour (24hr) and 7-day (7d) periods prior to each weekly private medical conference. Multiple imputation addressed missing data, and logistic regression modeled the relationship between probability of reported event of congestion or headache and CO2 levels, adjusted for possible confounding covariates. The first seven days of spaceflight were not included to control for fluid shifts. Data were evaluated to determine the concentration of CO2 required to maintain the risk of congestion below 1% to allow for direct comparison with a previously published evaluation of CO2 concentrations and headache. RESULTS: This study confirmed a previously identified significant association between CO2 and headache and also found a significant association between CO2 and congestion. For each 1-mm Hg increase in CO2, the odds of a crew member reporting congestion doubled. The average 7-day CO2 would need to be maintained below 1.5 mmHg to keep the risk of congestion below 1%. The predicted probability curves of ISS headache and congestion curves appear parallel when plotted against ppCO2 levels with congestion occurring at approximately 1mmHg lower than a headache would be reported. DISCUSSION: While the cause of congestion is multifactorial, this study showed congestion is associated with CO2 levels on ISS. Data from additional expeditions could be incorporated to further assess this finding. CO2 levels are also associated with reports of headaches on ISS. While it may be expected for astronauts with congestion to also complain of headaches, these two symptoms are commonly mutually exclusive. Furthermore, it is unknown if a temporal CO2 relationship exists between congestion and headache on ISS. CO2 levels were time-weighted for 24hr and 7d, and thus the time course of congestion leading to headache was not assessed; however, congestion could be an early CO2-related symptom when compared to headache. Future studies evaluating the association of CO2-related congestion leading to headache would be difficult due to the relatively stable daily CO2 levels on ISS currently, but a systematic study could be implemented on-orbit if desired.

Cole, Robert↗

Wind Tunnel Strain-Gage Balance Calibration Data Analysis Using a Weighted Least Squares Approach

A new approach is presented that uses a weighted least squares fit to analyze wind tunnel strain-gage balance calibration data. The weighted least squares fit is specifically designed to increase the influence of single-component loadings during the regression analysis. The weighted least squares fit also reduces the impact of calibration load schedule asymmetries on the predicted primary sensitivities of the balance gages. A weighting factor between zero and one is assigned to each calibration data point that depends on a simple count of its intentionally loaded load components or gages. The greater the number of a data point's intentionally loaded load components or gages is, the smaller its weighting factor becomes. The proposed approach is applicable to both the Iterative and Non-Iterative Methods that are used for the analysis of strain-gage balance calibration data in the aerospace testing community. The Iterative Method uses a reasonable estimate of the tare corrected load set as input for the determination of the weighting factors. The Non-Iterative Method, on the other hand, uses gage output differences relative to the natural zeros as input for the determination of the weighting factors. Machine calibration data of a six-component force balance is used to illustrate benefits of the proposed weighted least squares fit. In addition, a detailed derivation of the PRESS residuals associated with a weighted least squares fit is given in the appendices of the paper as this information could not be found in the literature. These PRESS residuals may be needed to evaluate the predictive capabilities of the final regression models that result from a weighted least squares fit of the balance calibration data.

calibration analysis↗

Method of Obtaining High Resolution Intrinsic Wire Boom Damping Parameters for Multi-Body Dynamics Simulations

The goal of NASA's Magnetospheric MultiScale (MMS) mission is to understand magnetic reconnection with sensor measurements from four spinning satellites flown in a tight tetrahedron formation. Four of the six electric field sensors on each satellite are located at the end of 60- meter wire booms to increase measurement sensitivity in the spin plane and to minimize motion coupling from perturbations on the main body. A propulsion burn however, might induce boom oscillations that could impact science measurements if oscillations do not damp to values on the order of 0.1 degree in a timely fashion. Large damping time constants could also adversely affect flight dynamics and attitude control performance. In this paper, we will discuss the implementation of a high resolution method for calculating the boom's intrinsic damping, which was used in multi-body dynamics simulations. In summary, experimental data was obtained with a scaled-down boom, which was suspended as a pendulum in vacuum. Optical techniques were designed to accurately measure the natural decay of angular position and subsequently, data processing algorithms resulted in excellent spatial and temporal resolutions. This method was repeated in a parametric study for various lengths, root tensions and vacuum levels. For all data sets, regression models for damping were applied, including: nonlinear viscous, frequency-independent hysteretic, coulomb and some combination of them. Our data analysis and dynamics models have shown that the intrinsic damping for the baseline boom is insufficient, thereby forcing project management to explore mitigation strategies.

Yew, Alvin G.↗

Aerosol Midlatitude Cyclone Indirect Effects in Observations and High-Resolution Simulations

Aerosol-cloud interactions are a major source of uncertainty in inferring the climate sensitivity from the observational record of temperature. The adjustment of clouds to aerosol is a poorly constrained aspect of these aerosol-cloud interactions. Here, we examine the response of midlatitude cyclone cloud properties to a change in cloud droplet number concentration (CDNC). Idealized experiments in high-resolution, convection-permitting global aquaplanet simulations with constant CDNC are compared to 13 years of remote-sensing observations. Observations and idealized aquaplanet simulations agree that increased warm conveyor belt (WCB) moisture flux into cyclones is consistent with higher cyclone liquid water path (CLWP). When CDNC is increased a larger LWP is needed to give the same rain rate. The LWP adjusts to allow the rain rate to be equal to the moisture flux into the cyclone along the WCB. This results in an increased CLWP for higher CDNC at a fixed WCB moisture flux in both observations and simulations. If observed cyclones in the top and bottom tercile of CDNC are contrasted it is found that they have not only higher CLWP but also cloud cover and albedo. The difference in cyclone albedo between the cyclones in the top and bottom third of CDNC is observed by CERES to be between 0.018 and 0.032, which is consistent with a 4.6-8.3 Wm(exp -2) in-cyclone enhancement in upwelling shortwave when scaled by annual-mean insolation. Based on a regression model to observed cyclone properties, roughly 60% of the observed variability in CLWP can be explained by CDNC and WCB moisture flux.

Mccoy, Daniel T.↗

Reliability of the Danish Aerospace Corporation Portable Pulmonary Function System

Metabolic gas analysis is a critical component of investigations that measure cardio-pulmonary exercise responses during and after long-duration spaceflight. The primary purpose of the current study was to determine the reliability and intra-subject repeatability of a metabolic gas analysis device, the Portable Pulmonary Function System (PPFS), designed for use on the International Space Station (ISS). The second objective of this study was to directly compare PPFS measurements of expired oxygen and carbon dioxide (FEO2 and FECO2) to values obtained from a well-validated clinical metabolic gas analysis system (ParvoMedics TrueOne (c) [PM]). Eight subjects performed four peak cycle tests to maximal exertion. The first test was used to prescribe work rates for the subsequent test sessions. Metabolic gas analysis for this test was performed by the PM, but samples of FEO2 and FECO2 also were simultaneously collected for analysis by the PPFS. Subjects then performed three additional peak cycle tests, consisting of three 5-min stages designed to elicit 25%, 50%, and 75% maximal oxygen consumption (VO2max) followed by stepwise increases of 25 W/min until subjects reached volitional exhaustion. Metabolic gas analysis was performed using the PPFS for these tests. Intraclass correlation coefficients (ICC), within-subject standard deviations (WS SD), and coefficients of variation (CV%) were calculated for the repeated exercise tests. Mixed model regression analysis was used to compare paired FEO2 and FECO2 values obtained from the PPFS and the PM during the initial test. The ICC values for oxygen consumption (VO2), carbon dioxide production (VCO2), and ventilation (VE) indicate that the PPFS is highly reliable (0.79 to 0.99) for all exercise levels tested; however, ICCs for respiratory exchange ratio (RER) were low ( 0.11 - 0.51), indicating poor agreement between trials during submaximal and maximal exercise. Overall, CVs ranged from 1.6% to 6.7% for all measurements, a finding consistent with reported values that were obtained using other metabolic gas analysis techniques. The PPFS and PM produced comparable FEO2 data; however, there was less agreement between measures of FECO2 obtained from the two devices, particularly at lower CO2 concentrations. The PPFS appears, in practically all respects, to yield highly reliable metabolic gas analysis data. Lower reliability of RER measurements reported in the literature and likely is not a function of the PPFS device. Further examination of PPFS CO2 data is warranted to better understand the limitations of these PPFS measurements. Overall, the PPFS when used for repeated measures of cardio-pulmonary exercise should provide accurate and reliable data for studies of human adaptation to spaceflight.

Portable Pulmonary Function System (PPFS)↗

Evaluation of the Danish Aerospace Corporation Portable Pulmonary Function System

A research project designed to investigate changes in maximal oxygen consumption (VO2max) during and following long duration flight on the International Space Station (ISS) has recently been completed. The device used to measure VO2 on board ISS, the Portable Pulmonary Function System (PPFS) manufactured by the Danish Aerospace Corporation (DAC), is based on previous-generation devices manufactured by DAC, but the PPFS has not been validated for analyzing metabolic gases or measuring cardiac output (Qc). The purpose of the present evaluation is to compare PPFS metabolic gas analysis measurements to measurements obtained using a clinically-validated system (ParvoMedics TrueOne(c) 2400 system; Parvo). In addition, Qc data collected with the PPFS were compared to Qc measurements from echocardiography. METHODS: Ten subjects completed three cycle exercise tests to maximal exertion. The first test was conducted to determine each subject's VO2max and set the work rates for the second and third (comparison) tests. The protocol for the two comparison tests consisted of three 5-minute stages designed to elicit 25%, 50%, and 75% VO2max (based upon results from the initial test), followed by 1-minute stages of increasing work rate (25 watt/minute) until the subject reached maximal effort. During one of the two comparison tests, metabolic gases and Qc were assessed with the PPFS; metabolic gases and Qc were assessed with the Parvo and by echocardiography, respectively, during the other test. The order of the comparison tests was counterbalanced. VO2max and maximal work rate during the comparison tests were compared using t tests. Mixed-effects regression modeling was used to analyze submaximal data. RESULTS: All of the data were within normal physiological ranges. The PPFS-measured values for VO2max were 6% lower than values obtained with the Parvo (PPFS: 3.11 +/- 0.75 L/min; Parvo: 3.32 +/- 0.87 L/min; mean +/- standard deviation; P = 0.02); this difference is probably due to flow restriction imposed by the PPFS Qc accessories. Submaximal VO2 values were slightly lower when measured with the PPFS, although differences were not physiologically relevant. The PPFS-measured values of submaximal carbon dioxide production (VCO2) were lower than the data obtained from Parvo, which could be attributed to lower fractions of expired carbon dioxide measured by the PPFS. The PPFS Qc values tended to be lower than echocardiography-derived values. CONCLUSIONS: The results of the present study indicate a need to further examine the PPFS and to better quantify its reproducibility; however, none of the findings of the current evaluation indicate that the PPFS needs to be replaced or modified.

Portable Pulmonary Function System (PPFS)↗

Integrating Cloud-Based Workflows in Continental-Scale Cropland Extent Classification

Accurate information on cropland spatial distribution is required for global-scale assessments and agricultural land use policies. Cloud computing platforms such as Google Earth Engine (GEE) provide unprecedented opportunities for large-scale classifications of Landsat data. We developed a novel method to fuse pixel-based random forest classification of continental-scale Landsat data on GEE and an object-based segmentation approach known as recursive hierarchical segmentation (RHSeg). Using our fusion method, we produced a continental-scale cropland extent map for North America at 30m spatial resolution for the nominal year 2010. The total cropland area for North America was estimated at 275.18 million hectares (Mha). The overall accuracies of the map are>90% across the continent. This map also compares well with the United States Department of Agriculture (USDA) cropland data layer (CDL), Agriculture and Agri-food Canada (AAFC) annual crop inventory (ACI), and the Mexican government agency Servicio de Informacion Agroalimentaria y Pesquera (SIAP)'s agricultural boundaries. Furthermore, our map compared well with sub-country statistics including state-wise and county-wise cropland statistics in regression models resulting in R2 > 0.84. This key contribution paves the way for more detailed products such as crop intensity, crop type, and crop irrigation, and provides a method for creating high-resolution cropland extent maps for other countries where spatial information about croplands are not as prevalent.

Massey, Richard↗

Coupling Fractional Thermal Runaway Calorimetry (FTRC) Results with Statistical Analysis Methods

Important factors to consider when optimizing Lithium-ion (Li-ion) battery thermal management systems, from a battery safety perspective, include the total energy released during a single cell thermal runaway (TR) event and the fraction of the total energy that is released through the cell casing versus through the ejecta material. A fractional thermal runaway calorimeter (FTRC) was used to examine the TR behavior of the following 18650-format Li-ion cells: (1) Molicel 18650-J, (2) LG 18650-HG2, (3) Samsung 18650-30Q, (4) 3.35 Ah LG 18650 test cell, (5) Sony 18650-VC7, and (6) LG 18650-MJ1. These cells were intentionally selected to represent a variety of manufacturers, chemistries, capacities, and safety features. Because of the large number of random and non-random variables associated with the FTRC results, a linear regression model, developed using engineering statistical methods, was utilized to provide final interpretation of the TR behavior for each cell type and design variable combination.

Walker, William↗

Operator Trust Function for Predicted Drone Arrival

To realize the full benefit from autonomy, systems will have to react to unknown events and uncertain dynamic environments. The resulting number of behaviors is essentially infinite; thus, the system is effectively non-deterministic but an operator needs to understand and trust the actions of the autonomous vehicles. This research began to tackle non-deterministic systems and trust by beginning to develop a user trust function based on intent information displayed and the prescribed bounds on allowable behaviors/actions of the non-deterministic system. Linear regression shows promise on being able to predict a person’s confidence of the machine’s prediction. Linear regression techniques indicated that subject characteristics, scenario difficulty, the experience with the system, and confidence earlier in the scenario account for approximately 60% of the variation in confidence ratings. This paper details the specifics of the liner regression model – essentially a trust function – for predicting a person’s confidence.

Trujillo, Anna C.↗

Fast-Time Simulation for Evaluating the Impact of Estimated Flight Ready Time Uncertainty on Surface Metering

NASA has been developing and demonstrating new concepts and technologies for Integrated Arrival, Departure, and Surface (IADS) traffic management capabilities under the Airspace Technology Demonstration 2 (ATD-2) project. One of the IADS capabilities in the ATD-2 project is surface metering enabled by a tactical surface scheduler to provide controllers with the pushback advisories for departures at gates. The tactical surface scheduler uses the estimated flight ready times provided by airlines, called Earliest Off-Block Times (EOBTs), as input to calculate the target off-block times for pushback advisories. However, the EOBTs are often inaccurate and deviate from the actual flight ready times, which may reduce the benefits of surface metering. In this paper, a linear regression model is developed to model the EOBT uncertainty distribution over time based on actual EOBT data collected at Charlotte airport. This EOBT model is integrated with a tactical surface scheduler and a fast-time simulation tool. To evaluate the impact of the EOBT accuracy on airport surface operations, fast-time simulations are implemented for selected traffic scenarios under different levels of modelled EOBT accuracy. The simulation results show that the EOBT uncertainty affects several performance metrics related to the surface metering, such as gate hold, taxi time reduction, and target takeoff time predictability, which in turn influences ATD-2's scheduler performance.

tactical surface scheduler↗

Fast-Time Simulation for Evaluating the Impact of Estimated Flight Ready Time Uncertainty on Surface Metering

NASA has been developing and demonstrating new concepts and technologies for Integrated Arrival, Departure, and Surface (IADS) traffic management capabilities under the Airspace Technology Demonstration 2 (ATD-2) project. One of the IADS capabilities in the ATD-2 project is surface metering enabled by a tactical surface scheduler to provide controllers with the pushback advisories for departures at gates. The tactical surface scheduler uses the estimated flight ready times provided by airlines, called Earliest Off-Block Times (EOBTs), as input to calculate the target off-block times for pushback advisories. However, the EOBTs are often inaccurate and deviate from the actual flight ready times, which may reduce the benefits of surface metering. In this paper, a linear regression model is developed to model the EOBT uncertainty distribution over time based on actual EOBT data collected at Charlotte airport. This EOBT model is integrated with a tactical surface scheduler and a fast-time simulation tool. To evaluate the impact of the EOBT accuracy on airport surface operations, fast-time simulations are implemented for selected traffic scenarios under different levels of modelled EOBT accuracy. The simulation results show that the EOBT uncertainty affects several performance metrics related to the surface metering, such as gate hold, taxi time reduction, and target takeoff time predictability, which in turn influences ATD-2's scheduler performance.

tactical surface scheduler↗

Short Data Gap Filling Algorithm Prototype

This design note describes an algorithm to fill short data gaps encountered in pixel or flux time series using auto-regressive modeling techniques.

Chandrasekaran, Hema↗

Exploring the Relationship Between Social Factors and Government Survey Nonresponse

In a previous study, we explored the relationship between economic and political factors and survey refusal, and noted the importance to collect or otherwise obtain measures that will help us understand more about the social aspect of the social-political-economic construct of survey nonresponse. Recently, we had the opportunity to collect such measures as part of the Census Tracking Survey. The Tracking Survey was launched in September 2019 and concluded in June 2020. It was a national survey conducted by the U.S. Census Bureau that tracked public awareness of the 2020 Census. Participants were asked about a variety of questions, including questions about social engagement and empathy, both possible measures of one’s social environment and hence one’s attitude towards participating in a government survey. To our knowledge, empathy has not been considered as factor of survey nonresponse. We propose that social factors such as these play an important role in the decision to participate in a survey. Using the Tracking Survey data, we built a logistic regression model, with plan to participate/participated in the 2020 Census as the dependent variable, and known and suspected factors of survey participation as independent variables. We found that social engagement and empathy were both important factors of participating in the Census.

Luke J. Larsen↗

Effect of aerosols and clouds on the retrieval of infrared sea surface temperatures

Comparisons are performed between spatially averaged sea surface temperatures (ASST2) as derived from the second Along-Track Scanning Radiometer (ATSR-2) on board the second European Remote Sensing Satellite (ERS-2) and the NOAA–NASA Advanced Very High Resolution Radiometer (AVHRR) Oceans Pathfinder dataset (MPFSST). Difference maps, MPFSST 2 ASST2, along with the application of a simple statistical regression model to aerosol and cloud data from the Total Ozone Mapping Spectrometer (TOMS), are used to examine the impact of possible aerosol and cloud contamination. Differences varied regionally, but the largest biases were seen off western Africa. Nighttime and daytime differences off western Africa were reduced from 20.58 to 20.28C and from 20.18 to 08C, respectively. Significant cloud flagging, based on the model, occurred in the Indian Ocean, the equatorial Pacific, and in the vicinity of the Gulf Stream. Comparisons of the MPFSST and the ASST2 with in situ data from the 2002 version of the World Oceanic Database (WOD02) off western Africa show larger mean differences for the MPFSST. The smallest mean differences occurred for nighttime ASST2 2 WOD02 with a value of 0.08 6 0.48C.

Armstrong, Edward M.↗

Midwest Food Security & Agriculture II: Leveraging NASA Earth Observations to Analyze and Display Crop Phenology Data and Weather Conditions to Support Expansion of Small Grain Crops in the Midwest

Agriculture in the Midwest is dominated by monoculture systems that strip the soil of nutrients, decrease yields, and worsen water quality. Crop diversification and cultivating small grains is economically and ecologically advantageous, but limited in practice due to a lack of data about small-grain crop performance as well as monoculture-favoring insurance coverage, economic incentives, and sociocultural traditions. Practical Farmers of Iowa (PFI) strives to create more sustainable agriculture and supports Midwestern farmers in adding small grains into their crop rotations. The DEVELOP team partnered with the USDA Agricultural Research Service and the USA National Phenology Network to assist PFI in applying NASA Earth observation data to track small-grain crop performance. This project developed a Google Earth Engine user interface that enables PFI farmers to compare satellite-assessed vegetation production and climatic conditions of their farm with other PFI farmers. The team assessed the crop performance through Normalized Difference Vegetation Index (NDVI) values derived from Landsat 7 Enhanced Thematic Mapper Plus (ETM+) and Landsat 8 Operational Land Imager (OLI). Additionally, the team created a regression model to analyze the predictive properties of vegetation indices and crop yield, ultimately establishing a relationship with mean NDVI from the early growing season. PFI farmers can utilize these products to make informed decisions about their crop production as well as advocate for more expansive insurance policies to protect small-grain crops.

Sophie Barrowman↗

Peru Health and Air Quality II: Leveraging Earth Observations and Health Data to Map Outbreak Risk and Inform Public Health Interventions for Zoonotic Disease Prevention

Peru's Madre de Dios region is a hotspot for dengue fever and leishmaniasis due to its tropical Amazonian climate. Though treatable, these zoonotic diseases are debilitating for under-resourced communities whose already close proximity to mosquito and sandfly vectors continues to increase via rapid urbanization and deforestation. Peru’s Ministries of Health (MINSA) and Environment (MINAM) are working to better understand the environmental factors amplifying the risk of dengue fever and leishmaniasis transmission. The first term of this project classified the land use and land cover of Madre de Dios’ 11 districts for 2010, 2015, and 2020 and identified a correlation between both diseases and urbanization. Our team expanded this analysis by creating urban-forest edge maps and incorporating climatic and topographic variables with data from Landsat 7 Enhanced Thematic Mapper Plus (ETM+), Landsat 8 Operational Land Imager (OLI), the Global Precipitation Measurement (GPM) Integrated Multi-satellitE Retrievals for GPM (IMERG), and the Shuttle Radar Topography Mission (SRTM). We determined these variables’ impacts on disease incidence by assessing existing literature and running regression models. Dengue fever correlated with urban-forest edge, urban area, slope, temperature, and precipitation. Leishmaniasis primarily correlated with forest-edge area and elevation, but lacking additional statistical significance prevented further work, a decision supported by the literature. Thus, the risk matrix and risk map which we scripted in R to visualize the risk of disease posed to districts alongside health post locations addresses only dengue fever. The results and products will inform MINSA and MINAM in public health interventions, resource distribution, and policy initiatives.

Jennifer Rogers↗

Post-Landing Major Element Quantification Using SuperCam Laser Induced Breakdown Spectroscopy

The SuperCam instrument on the PerseveranceMars 2020 rover uses a pulsed 1064 nm laser to ablate targets at a distance and conduct laser induced breakdown spectroscopy (LIBS) by analyzing the light from the resulting plasma. SuperCam LIBS spectra are preprocessed to remove ambient light, noise, and the continuum signal present in LIBS observations. Prior to quantification, spectra are masked to remove noisier spectrometer regions andspectra are normalized to minimize signal fluctuations and effectsof target distance.In some cases, the spectra are also standardized or binned prior to quantification. To determine quantitative elemental compositionsof diverse geologic materials at Jezero crater, Mars, we use a suite of 1198 laboratory spectra of 334 well-characterized reference samples. The samples were selected to span a wide range of compositions and include typical silicate rocks, pure minerals (e.g.,silicates, sulfates, carbonates, oxides),more unusual compositions (e.g.,Mn oreand sodalite), andreplicates of the sintered SuperCam calibration targets (SCCTs) onboardthe rover. For each major element (SiO2, TiO2, Al2O3, FeOT, MgO, CaO, Na2O, K2O), the database was subdivided into five“folds” with similar distributions of the element of interest. One fold was held out as an independent test set, and the remaining fourfolds were used to optimize multivariate regression models relating the spectrum to the composition. We considered a variety of models, and selected several for further investigation for each element, based primarily on the root mean squared error of prediction (RMSEP) on the test set, when analyzed at 3m. In cases with several models of comparable performance at 3 m, we incorporated the SCCT performance at different distances to choose the preferred model. Shortly after landing on Mars and collecting initial spectra of geologic targets, we selected one model per element. Subsequently, with additional data from geologic targets, some models were revised to ensure results that are more consistent with geochemical constraints. The calibration discussed here is a snapshot of an ongoing effort to deliver the most accurate chemical compositions with SuperCam LIBS.

Mars 2020↗