Search NASA⌕ Search

SEARCH · Search NASA

Results for “Relative Motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Magnetic Resonance Imaging–Guided versus Surrogate-Based Motion Tracking in Liver Radiation Therapy: A Prospective Comparative Study

Purpose: This study applied automatic feature detection on cine–magnetic resonance imaging (MRI) liver images in order to provide a prospective comparison between MRI-guided and surrogate-based tracking methods for motion-compensated liver radiation therapy. Methods and Materials: In a population of 30 subjects (5 volunteers plus 25 patients), 2 oblique sagittal slices were acquired across the liver at high temporal resolution. An algorithm based on scale invariant feature transform (SIFT) was used to extract and track multiple features throughout the image sequence. The position of abdominal markers was also measured directly from the image series, and the internal motion of each feature was quantified through multiparametric analysis. Surrogate-based tumor tracking with a state-of-the-art external/internal correlation model was simulated. The geometrical tracking error was measured, and its correlation with external motion parameters was also investigated. Finally, the potential gain in tracking accuracy relying on MRI guidance was quantified as a function of the maximum allowed tracking error. Results: An average of 45 features was extracted for each subject across the whole liver. The multi-parametric motion analysis reported relevant inter- and intrasubject variability, highlighting the value of patient-specific and spatially-distributed measurements. Surrogate-based tracking errors (relative to the motion amplitude) were were in the range 7% to 23% (1.02-3.57mm) and were significantly influenced by external motion parameters. The gain of MRI guidance compared to surrogate-based motion tracking was larger than 30% in 50% of the subjects when considering a 1.5-mm tracking error tolerance. Conclusions: Automatic feature detection applied to cine-MRI allows detailed liver motion description to be obtained. Such information was used to quantify the performance of surrogate-based tracking methods and to provide a prospective comparison with respect to MRI-guided radiation therapy, which could support the definition of patient-specific optimal treatment strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive vibration control using synchronous demodulation with machine tool controller motor commutation

A control system and method for actively reducing vibration in a spindle housing caused by unbalance forces on a rotating spindle, by measuring the force-induced spindle-housing motion, determining control signals based on synchronous demodulation, and provide compensation for the measured displacement to cancel or otherwise reduce or attenuate the vibration. In particular, the synchronous demodulation technique is performed to recover a measured spindle housing displacement signal related only to the rotation of a machine tool spindle, and consequently rejects measured displacement not related to spindle motion or synchronous to a cycle of revolution. Furthermore, the controller actuates at least one voice-coil (VC) motor, to cancel the original force-induced motion, and adapts the magnitude of voice coil signal until this measured displacement signal is brought to a null. In order to adjust the signal to a null, it must have the correct phase relative to the spindle angle. The feedback phase signal is used to adjust a common (to both outputs) commutation offset register (offset relative to spindle encoder angle) to force the feedback phase signal output to a null. Once both of these feedback signals are null, the system is compensating properly for the spindle-induced motion.

47 OTHER INSTRUMENTATION↗

Post-Newtonian effects on Lagrange's equilateral triangular solution for the three-body problem

Continuing work initiated in earlier publications [Yamada, Asada, Phys. Rev. D 82, 104019 (2010); ibid.83, 024040 (2011)], we investigate the post-Newtonian effects on Lagrange's equilateral triangular solution for the three-body problem. For three finite masses, it is found that the equilateral triangular configuration satisfies the post-Newtonian equation of motion in general relativity, if and only if all three masses are equal. When a test mass is included, the equilateral configuration is possible for two cases: (1) one mass is finite and the other two are zero, or (2) two of the masses are finite and equal, and the third one is zero, namely, a symmetric binary with a test mass. The angular velocity of the post-Newtonian equilateral triangular configuration is always smaller than the Newtonian one, provided that the masses and the side length are the same.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Numerical Study of Forbush Decreases with a 3D Cosmic-Ray Modulation Model Based on an SDE Approach

Based on the reduced diffusion mechanism for producing Forbush decreases (Fds) in the heliosphere, we constructed a three-dimensional (3D) diffusion barrier, and by incorporating it into a stochastic differential equation (SDE) based time-dependent, cosmic-ray transport model, a 3D numerical model for simulating Fds is built and applied to a period of relatively quiet solar activity. This SDE model generally corroborates previous Fd simulations concerning the effects of the solar magnetic polarity, the tilt angle of the heliospheric current sheet (HCS), and cosmic-ray particle energy. Because the modulation processes in this 3D model are multi-directional, the barrier’s geometrical features affect the intensity profiles of Fds differently. We find that both the latitudinal and longitudinal extent of the barrier have relatively fewer effects on these profiles than its radial extent and the level of decreased diffusion inside the disturbance. We find, with the 3D approach, that the HCS rotational motion causes the relative location from the observation point to the HCS to vary, so that a periodic pattern appears in the cosmic-ray intensity at the observing location. Correspondingly, the magnitude and recovery time of an Fd change, and the recovering intensity profile contains oscillation as well. Investigating the Fd magnitude variation with heliocentric radial distance, we find that the magnitude decreases overall and, additionally, that the Fd magnitude exhibits an oscillating pattern as the radial distance increases, which coincides well with the wavy profile of the HCS under quiet solar modulation conditions.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-163: A Biomechanical Lung Model for Respiratory Motion Study

Purpose: This work presents a biomechanical model to investigate the complex respiratory motion for the lung tumor tracking in radiosurgery by computer simulation. Methods: The models include networked massspring-dampers to describe the tumor motion, different types of surrogate signals, and the force generated by the diaphragm. Each mass-springdamper has the same mechanical structure and each model can have different numbers of mass-spring-dampers. Both linear and nonlinear stiffness parameters were considered, and the damping ratio was tuned in a range so that the tumor motion was over-damped (no natural tumor oscillation occurs without force from the diaphragm). The simulation was run by using ODE45 (ordinary differential equations by Runge-Kutta method) in MATLAB, and all time courses of motions and inputs (force) were generated and compared. Results: The curvature of the motion time courses around their peaks was sensitive to the damping ratio. Therefore, the damping ratio can be determined based on the clinical data of a high sampling rate. The peak values of different signals and the time the peaks occurred were compared, and it was found that the diaphragm force had a time lead over the tumor motion, and the lead time (0.1–0.4 seconds) depended on the distance between the tumor and the diaphragm. Conclusion: We reported a model based analysis approach for the spatial and temporal relation between the motion of the lung tumor and the surrogate signals. Due to the phase lead of the diaphragm in comparing with the lung tumor motion, the measurement of diaphragm motion (or its electromyography signal) can be used as a beam gating signal in radiosurgery, and it can also be an additional surrogate signal for better tumor motion tracking. The research is funded by the American Cancer Society (ACS) grant. The grant name is: Frameless SRS Based on Robotic Head Motion Cancellation. The grant number is: RSG-13-313-01-CCE.

60 APPLIED LIFE SCIENCES↗

Complexes of in-phase two-dimensional laser solitons

The structure and motion of complexes of in-phase weakly coupled fundamental solitons in a wide-aperture class A laser with saturable absorption are analysed. The symmetry of the field distribution and its relation to the motion of the complex are studied. Due to the absence of wavefront dislocations in such complexes, the transverse radiation intensity and phase distributions are the symmetry objects, which simplifies analysis compared to the case when wavefront dislocations are present. Four types of the motion of soliton complexes are demonstrated: a motionless complex in the presence of two mirror symmetry axes; linear motion of the complex when only one mirror symmetry axis exists; rotation around a motionless centre of inertia in the absence of the mirror symmetry axis and in the presence of symmetry with respect to rotation through the angle 2{pi}/M (M is an integer); and curvilinear (circular) motion of the centre of inertia and simultaneous rotation of the complex around the instantaneous position of the centre of inertia in the absence of symmetry elements. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine Learning for Daily Forecasts of Arctic Sea Ice Motion: An Attribution Assessment of Model Predictive Skill

Physics-based simulations of Arctic sea ice are highly complex, involving transport between different phases, length scales, and time scales. Resultantly, numerical simulations of sea ice dynamics have a high computational cost and model uncertainty. We employ data-driven machine learning (ML) to make predictions of sea ice motion. The ML models are built to predict present-day sea ice velocity given present-day wind velocity and previous-day sea ice concentration and velocity. Models are trained using reanalysis winds and satellite-derived sea ice properties. We compare the predictions of three different models: persistence (PS), linear regression (LR), and a convolutional neural network (CNN). We quantify the spatiotemporal variability of the correlation between observations and the statistical model predictions. Additionally, we analyze model performance in comparison to variability in properties related to ice motion (wind velocity, ice velocity, ice concentration, distance from coast, bathymetric depth) to understand the processes related to decreases in model performance. Results indicate that a CNN makes skillful predictions of daily sea ice velocity with a correlation up to 0.81 between predicted and observed sea ice velocity, while the LR and PS implementations exhibit correlations of 0.78 and 0.69, respectively. The correlation varies spatially and seasonally: lower values occur in shallow coastal regions and during times of minimum sea ice extent. LR parameter analysis indicates that wind velocity plays the largest role in predicting sea ice velocity on 1-day time scales, particularly in the central Arctic. Regions where wind velocity has the largest LR parameter are regions where the CNN has higher predictive skill than the LR.

54 ENVIRONMENTAL SCIENCES↗

Passive magnetic bearing systems stabilizer/bearing utilizing time-averaging of a periodic magnetic field

A high-stiffness stabilizer/bearings for passive magnetic bearing systems is provide where the key to its operation resides in the fact that when the frequency of variation of the repelling forces of the periodic magnet array is large compared to the reciprocal of the growth time of the unstable motion, the rotating system will feel only the time-averaged value of the force. When the time-averaged value of the force is radially repelling by the choice of the geometry of the periodic magnet array, the Earnshaw-related unstable hit motion that would occur at zero rotational speed is suppressed when the system is rotating at operating speeds.

42 ENGINEERING↗

A FIRST MEASUREMENT OF THE PROPER MOTION OF THE LEO II DWARF SPHEROIDAL GALAXY

We use 14 year baseline images obtained with the Wide Field and Planetary Camera 2 on board the Hubble Space Telescope (HST) to derive a proper motion for one of the Milky Way's most distant dwarf spheroidal companions, Leo II, relative to an extragalactic background reference frame. Astrometric measurements are performed in the effective point-spread function formalism using our own developed code. An astrometric reference grid is defined using 3224 stars that are members of Leo II and brighter than a magnitude of 25 in the F814W band. We identify 17 compact extragalactic sources, for which we measure a systemic proper motion relative to this stellar reference grid. We derive a proper motion [{mu}{sub {alpha},{mu}{delta}}] = [+104 {+-}113,-33 {+-} 151] {mu}as yr{sup -1} for Leo II in the heliocentric reference frame. Though marginally detected, the proper motion yields constraints on the orbit of Leo II. Given a distance of d {approx_equal} 230 kpc and a heliocentric radial velocity v{sub r} = +79 km s{sup -1}, and after subtraction of the solar motion, our measurement indicates a total orbital motion v{sub G} = 266.1 {+-} 128.7 km s{sup -1} in the Galactocentric reference frame, with a radial component v{sub r{sub G}}=21.5{+-}4.3 km s{sup -1} and tangential component v{sub t{sub G}} = 265.2 {+-} 129.4 km s{sup -1}. The small radial component indicates that Leo II either has a low-eccentricity orbit or is currently close to perigalacticon or apogalacticon distance. We see evidence for systematic errors in the astrometry of the extragalactic sources which, while close to being point sources, are slightly resolved in the HST images. We argue that more extensive observations at later epochs will be necessary to better constrain the proper motion of Leo II. We provide a detailed catalog of the stellar and extragalactic sources identified in the HST data which should provide a solid early-epoch reference for future astrometric measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

The Structure of the Iron Binding Protein, FutA1, from Synechocystis 6803*

Cyanobacteria account for a significant percentage of aquatic primary productivity even in areas where the concentrations of essential micronutrients are extremely low. To better understand the mechanism of iron selectivity and transport, the structure of the solute-binding domain of an ABC iron transporter, FutA1, was determined in the presence and absence of iron. The iron ion is bound within the ‘C-clamp’ structure via four tyrosine and one histidine residues. There are extensive interactions between these ligating residues and the rest of the protein such that the conformations of the side chains remain relatively unchanged as the iron is released by the opening of the metal binding cleft. This is in stark contrast to the zinc binding protein, ZnuA, where the domains of the metal binding protein remain relatively fixed while the ligating residues rotate out of the binding pocket upon metal release. The rotation of the domains in FutA1 is facilitated by two flexible β-strands running along the back of the protein that act like a hinge during domain motion. This motion may require relatively little energy since total contact area between the domains is the same whether the protein is in the open or closed conformation. Consistent with the pH dependency of iron binding, the main trigger for iron release is likely the histidine in the iron-binding site. Finally, neither FutA1 nor FutA2 binds iron as a siderophore complex or in the presence of anions and both preferentially bind ferrous over ferric ions.

59 BASIC BIOLOGICAL SCIENCES↗

The mass formula for an exotic BTZ black hole

An exotic Bañados–Teitelboim–Zanelli (BTZ) black hole has an angular momentum larger than its mass in three dimension (3D), which suggests the possibility that cosmic censorship could be violated if angular momentum is extracted by the Penrose process. In this paper, we propose a mass formula for the exotic BTZ black hole and show no violation of weak cosmic censorship in the gedanken process above by understanding properly its mass formula. Unlike the other black holes, the total energy of the exotic BTZ black hole is represented by the angular momentum instead of the mass, which supports a basic point of view that the same geometry should be determined by the same energy in 3D general relativity whose equation of motion can be given either by normal 3D Einstein gravity or by exotic 3D Einstein gravity. However, only the mass of the exotic black hole is related to the thermodynamics and other forms of energy are “dumb”, which is consistent with the earlier thermodynamic analysis about exotic black holes.

79 ASTRONOMY AND ASTROPHYSICS↗

Cardiac Motion During Deep-Inspiration Breath-Hold: Implications for Breast Cancer Radiotherapy

Purpose: Many patients with left-sided breast cancer receive adjuvant radiotherapy during deep-inspiration breath hold (DIBH) to minimize radiation exposure to the heart. We measured the displacement of the left anterior descending artery (LAD) and heart owing to cardiac motion during DIBH, relative to the standard tangential fields for left breast cancer radiotherapy. Methods and Materials: A total of 20 patients who had undergone computed tomography-based coronary angiography with retrospective electrocardiographic gating were randomly selected for the present study. The patients underwent scanning during DIBH to control the influence of respiration on cardiac motion. Standard medial and lateral tangential fields were placed, and the LADs were contoured on the systolic- and diastolic-phase computed tomography data sets by the clinicians. Displacement of the LAD during cardiac contractions was calculated in three directions: toward the posterior edge of the treatment fields, left-right, and anteroposterior. Displacement of the entire heart was measured on the maximal and minimal intensity projection computed tomography images. Results: The mean displacement of the LAD from cardiac contraction without the influence of respiration for 20 patients was 2.3 mm (range, 0.7-3.8) toward the posterior edge of the treatment fields, 2.6 mm (range, 1.0-6.8) in the left-right direction, and 2.3 mm (range, 0.6-6.5) in the anteroposterior direction. At least 30% of the LAD volume was displaced >5 mm in any direction in 2 patients (10%), and <10% of the LAD volume was displaced >5 mm in 10 patients (50%). The extent of displacement of the heart periphery during cardiac motion was negligible near the treatment fields. Conclusions: Displacement of the heart periphery near the treatment fields was negligible during DIBH; however, displacement of the LAD from cardiac contraction varied substantially between and within patients. We recommend maintaining {>=}5 mm of distance between the LAD and the field edge for patients undergoing breast cancer radiotherapy during DIBH.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Density functionals in the laboratory frame

We compare several definitions of the density of a self-bound system, such as a nucleus, in relation with its center-of-mass zero-point motion. A trivial deconvolution relates the internal density to the density defined in the laboratory frame. This result is useful for the practical definition of density functionals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Slowly rotating relativistic stars in tensor-vector-scalar theory

In order to examine the rotational effect around neutron star in tensor-vector-scalar (TeVeS) theory, we consider the slowly rotating relativistic stars with a uniform angular velocity. As a result, we find that similar to the case in general relativity (GR), the angular momentum is proportional to the angular velocity. Additionally, as the value of coupling constant K becomes higher, the frame dragging in TeVeS becomes quite different distribution from that in GR, where we can also see the deviation even in the interior of star. While with smaller value of K, although the frame dragging approaches to that expected in GR, the induced vector field due to the rotation does not vanish and still exists. Thus, through the observations associated with relativistic object, one could be possible to distinguish the gravitational theory in strong field regime even in the case that the value of coupling constant K is quite small.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-G-JeP1-07: Development of a Programmable Motion Testbed for the Validation of Ultrasound Tracking Algorithms

Purpose: To develop an advanced testbed that combines a 3D motion stage and ultrasound phantom to optimize and validate 2D and 3D tracking algorithms for real-time motion management during radiation therapy. Methods: A Siemens S2000 Ultrasound scanner utilizing a 9L4 transducer was coupled with the Washington University 4D Phantom to simulate patient motion. The transducer was securely fastened to the 3D stage and positioned to image three cylinders of varying contrast in a Gammex 404GS LE phantom. The transducer was placed within a water bath above the phantom in order to maintain sufficient coupling for the entire range of simulated motion. A programmed motion sequence was used to move the transducer during image acquisition and a cine video was acquired for one minute to allow for long sequence tracking. Images were analyzed using a normalized cross-correlation block matching tracking algorithm and compared to the known motion of the transducer relative to the phantom. Results: The setup produced stable ultrasound motion traces consistent with those programmed into the 3D motion stage. The acquired ultrasound images showed minimal artifacts and an image quality that was more than suitable for tracking algorithm verification. Comparisons of a block matching tracking algorithm with the known motion trace for the three features resulted in an average tracking error of 0.59 mm. Conclusion: The high accuracy and programmability of the 4D phantom allows for the acquisition of ultrasound motion sequences that are highly customizable; allowing for focused analysis of some common pitfalls of tracking algorithms such as partial feature occlusion or feature disappearance, among others. The design can easily be modified to adapt to any probe such that the process can be extended to 3D acquisition. Further development of an anatomy specific phantom better resembling true anatomical landmarks could lead to an even more robust validation. This work is partially funded by NIH grant R01CA190298.

60 APPLIED LIFE SCIENCES↗

Investigation of Site Amplifications Using Ambient-Noise-Derived Shallow Velocity Structures Under a Dense Array in Oklahoma

The shear-wave velocity (V S ) structure plays an important role in characterizing site amplification. The Large-n Seismic Survey in Oklahoma (LASSO; 1820 stations) revealed large vertical ground-motion variability in a 25 km × 32 km area in northern Oklahoma. The LASSO array has a relatively simple and flat topography, typical in a sedimentary basin environment in the central United States. In this study, we use the dense array to investigate the velocity structure under the LASSO array and how vertical ground motions relate to the shallow-to-deep structures. We extract the fundamental-mode Rayleigh wave by cross-correlating one month of ambient noise (0.7–5 Hz). We use double-beamforming to measure the group and phase velocities and anisotropy. By jointly inverting the group and phase velocities, we obtain the V S structure. Here, we observe correlations between V S at depths of 0.1–1.5 km and vertical ground motions using sites on the stiffer Permian formations. The shallow Quaternary alluvium and terrace deposits can amplify vertical ground motions by a factor of 2–4.5 between 2 and 25 Hz and attenuate signals above 25 Hz. We use 1D V S profiles to simulate the SV-wave transfer functions. An average V S of 250 m/s in the upper 20–40 m may cause the observed amplification between 2 and 40 Hz. V S estimated by topographic slopes cannot predict the relative amplification. Our results highlight the large variability of site-dependent ground motion in a small local region and the importance of characterizing shallow structures to estimate seismic hazards. Small thickness variations of the shallow formation can significantly change the resonance amplitude and frequency, which likely reduces the coherency of the Rayleigh waves extracted from ambient noise.

Chang, Hilary [Massachusetts Inst. of Technology (↗

Crystalline polyoxometalate (POM)–polyethylene glycol (PEG) composites aimed as non-humidified intermediate-temperature proton conductors

Crystalline polyoxometalate (POM)–polyethylene glycol (PEG) composites aimed as non-humidified intermediate-temperature proton conductors were synthesized and characterized by single crystal and powder XRD, solid state MASNMR, and TG-DTA measurements. Among the POM–PEG composites, Cs{sub 2.7}H{sub 0.3}[PW{sub 12}O{sub 40}]·1.2PEG1000 (CsHPW-PEG1000) possessed one-dimensional channels with diameters of ca. 6 and 8 Å, where PEG probably resided, and showed the best performance as a proton conductor (1.2×10{sup −5} S cm{sup −1} at 443 K). Proton conductivities of POM–PEG composites decreased by the increase in molecular weights of PEG (CsHPW-PEG12,000) or anion charges (CsHSiW-PEG1000). Variable contact time {sup 13}C-CP (cross polarization) MASNMR revealed that local mobility (i.e., segmental motion) of PEG is related to the trends in proton conductivities. These results show that amount of acidic protons (H{sup +}) is not the primary factor in proton conduction and that segmental motion of PEG assists the proton hopping among POMs in the crystal lattice of POM–PEG composites. - Graphical abstract: Non-humidified intermediate-temperature proton conduction in crystalline polyoxometalate (POM)–polyethylene (PEG) composites are assisted by the segmental motion of PEG. - Highlights: • Crystalline polyoxometalate–polyethlene glycol (PEG) composites were synthesized. • CsHPW-PEG1000 possessed one-dimensional channels and showed the highest proton conductivity. • {sup 13}C CPMASNMR revealed that segmental motion of PEG is related to the proton conduction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Collective motion in a quantum diffusive environment

The general problem of dissipation in macroscopic large-amplitude collective motion and its relation to energy diffusion of intrinsic degrees of freedom of a nucleus is studied. By applying the cranking approach to the nuclear many-body system, a set of coupled dynamical equations for the collective classical variable and the quantum mechanical occupancies of the intrinsic nuclear states is derived in the limit of weak coupling of the collective and intrinsic subsystems. Different dynamical regimes of the intrinsic nuclear motion and its consequences on time properties of collective dissipation are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗