Search NASA⌕ Search

SEARCH · Search NASA

Results for “Resonance techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

The theory of an auto-resonant field emission cathode relativistic electron accelerator for high efficiency microwave to direct current power conversion

A novel method of microwave power conversion to direct current is discussed that relies on a modification of well known resonant linear relativistic electron accelerator techniques. An analysis is presented that shows how, by establishing a 'slow' electromagnetic field in a waveguide, electrons liberated from an array of field emission cathodes, are resonantly accelerated to several times their rest energy, thus establishing an electric current over a large potential difference. Such an approach is not limited to the relatively low frequencies that characterize the operation of rectennas, and can, with appropriate waveguide and slow wave structure design, be employed in the 300 to 600 GHz range where much smaller transmitting and receiving antennas are needed.

Manning, Robert M.↗

Structure of Diisobutylene Maleic Acid Copolymer (DIBMA) and Its Lipid Particle as a “Stealth” Membrane-Mimetic for Membrane Protein Research

The study of membrane proteins remains challenging, especially in a native membrane environment. Recently, major progress has been made using maleic acid copolymers, such as styrene maleic acid, to purify membrane proteins and study them directly with native lipids associated with the membrane. Additional maleic acid copolymers, such as diisobutylene maleic acid (DIBMA) membrane-mimetic systems, are being developed and found to have improved spectroscopic properties and pH stability. We studied DIBMA and its lipid particles in solution to better understand its assembly, without and with the lipids, to provide an insight regarding how to use it in solution for better membrane extraction. Using small-angle neutron and X-ray scattering (SANS/SAXS), we show that DIBMA organizes into structures of different size scales at various concentrations and ionic strengths. The polymer performed reasonably well under most solvent conditions except in very low concentrations and high-salt conditions that could result in limited interaction with lipids. To explore DIBMA lipid particles as a suitable membrane-mimetic system for neutron scattering studies of membrane proteins, we measured and determined the contrast-matching point of DIBMA to be ~12% (v/v) D 2 O — similar to that of most protiated lipid molecules but distinct from that of regular protiated proteins — providing a natural contrast for separating their neutron scattering signals. Using SANS contrast variation, we demonstrated that the scattering from the whole lipid particle can be annihilated. Further, we determined that a well-defined lipid nanodisc structure with DIBMA was contrast-matched. These results demonstrate that the DIBMA lipid particle is an outstanding “stealth” membrane-mimetic for membrane proteins. The results provide a structural framework for understanding the organization and assembly process of the polymer itself and the lipid molecules. Such an understanding is imperative for structural techniques such as cryo-electron microscopy, nuclear magnetic resonance, small-angle scattering, and other biophysical techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ESR Measurement Of Crystallinity In Semicrystalline Polymers

Photogenerated free radicals decay at different rates in crystalline and amorphous phases. Degree of crystallinity in polymer having both crystalline and amorphous phases measured indirectly by technique based in part on electron-spin-resonance (ESR) spectroscopy. Accuracy of crystallinity determined by new technique equals or exceeds similar determinations by differential scanning calorimetry, wide-angle x-ray scattering, or measurement of density.

Kim, Soon Sam↗

Resonances in Positronium Hydride

Recently, Ho and his colleagues have calculated the positions and widths of a series of resonances in the Ps+H scattering system, using the complex -rotation method and have compared them with estimates that I made many years ago using a quite different technique. I assumed that the resonance mechanism was the existence in the rearrangement channel [e+ + H-] of an infinite series of perturbed Coulomb bound states. Although these must be broadened and shifted by coupling with the open scattering channel, I expected them to lie very close to the actual resonance positions. To verify this, I did a model calculation for S-waves, including the coupling, and found that the first two resonances were not shifted very far from their unperturbed position. The new, detailed calculation agrees with this result, but when the P-wave was examined it was found, surprisingly, that the lowest resonance indeed moved up in energy by a large amount. With the help of Joseph DiRienzi of the College of Notre Dame of Maryland I am now extending the old calculation to P- and D-waves, in an attempt to understand this unexpected energy shift. Results will be presented at the Workshop.

Drachman, Richard J.↗

Sub-Hertz resonance by weak measurement

Weak measurement (WM) with state pre- and post-selection can amplify otherwise undetectable small signals and thus has potential in precision measurement applications. Although frequency measurements offer the hitherto highest precision due to the stable narrow atomic transitions, it remains a long-standing interest to develop new schemes to further escalate their performance. Here, we demonstrate a WM-enhanced correlation spectroscopy technique capable of narrowing the resonance linewidth down to 0.1 Hz in a room-temperature atomic vapour cell. The potential of this technique for precision measurement is demonstrated through weak magnetic-field sensing. By judiciously pre- and post-selecting frequency-modulated input and output optical states in a nearly orthogonal manner, a sensitivity of 7 fT Hz -1/2 at a low frequency near DC is achieved using only one laser beam with 15 µW of power. Additionally, our results extend the WM framework to a non-Hermitian Hamiltonian and shed new light on metrology and bio-magnetic field sensing.

Science & Technology - Other Topics↗

Development of a Vibration Technique Based on Geometric Optimization for Fatigue Life Evaluation of Sandwich Composite Structures

A major obstacle to obtaining cost-effective experimental data on the fatigue life of sandwich panels is the prohibitive amount of time and cost required to carry out millions of cycles. On the other hand, vibration techniques applied to sandwich geometries fail to match the stress patterns that are obtained from standard flexural fatigue tests. To overcome such limitations, a vibration-based fatigue technique is proposed, which entails the use of sandwich specimens whose geometries are optimized to reproduce the stress distribution observed during three point bend loading while vibrating at the first resonant frequency. The proposed vibration technique was experimentally validated. The results, compared with the average number of cycles to failure at different stress ratios obtained via the Three-Point Bending test, showed high levels of accuracy. The proposed method is robust and time effective and indicates the possibility of attaining fatigue lifetime prediction of a wide class of composite elements, such as sandwich panels.

36 MATERIALS SCIENCE↗

TPSAS-NF1676L-32869-DND

Three unseeded molecular tagging velocimetry (MTV) techniques have been demonstrated in NASA Langley’s 0.3-meter Transonic Cryogenic Tunnel (TCT). High pressure, cryogenic gaseous N2 is used to produce high Reynolds number transonic flow in TCTs, allowing small aircraft and space vehicles to be tested at flight Reynolds numbers. These facilities generally cannot be seeded with particles or toxic gases so unseeded velocimetry methods are needed. Three Laser Electronic Excitation and Tagging (LEET) techniques were tested: Femtosecond LEET (FLEET), Picosecond LEET (PLEET) and Selective Two-photon Absorptive Resonance Femtosecond LEET (STARFLEET). All three techniques were used over a range of pressures (124 to 517 kPa), temperatures (100-300 K) and Mach numbers (0.2-0.8) to measure freestream conditions and were then compared to conditions determined by the facility data system using conventional wall pressures and probes. Measurement precision and accuracy are presented, as are signal intensity and lifetimes which impact measurement uncertainties and are useful for understanding and modelling the various LEET processes.

P Danehy↗

Measurements of a quantum bulk acoustic resonator using a superconducting qubit

Phonon modes at microwave frequencies can be cooled to their quantum ground state using conventional cryogenic refrigeration, providing a convenient way to study and manipulate quantum states at the single phonon level. Phonons are of particular interest because mechanical deformations can mediate interactions with a wide range of different quantum systems, including solid-state defects, superconducting qubits, and optical photons when using optomechanically active constructs. Phonons, thus, hold promise for quantum-focused applications as diverse as sensing, information processing, and communication. Here, we describe a piezoelectric quantum bulk acoustic resonator (QBAR) with a 4.88 GHz resonant frequency, which, at cryogenic temperatures, displays large electromechanical coupling strength combined with a high intrinsic mechanical quality factor, Q i ≈ 4.3 × 10 4 . Using a recently developed flip-chip technique, we couple this QBAR resonator to a superconducting qubit on a separate die and demonstrate the quantum control of the mechanics in the coupled system. Furthermore, this approach promises a facile and flexible experimental approach to quantum acoustics and hybrid quantum systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Precision ultranarrow-linewidth resonance excitation (PURE) preparation of a molecular beam of nitric oxide molecules for inelastic scattering with argon

We recently reported a novel technique that utilizes narrow-linewidth lasers to selectively excite molecules into a pure quantum state with a well-resolved, tunable distribution of velocities [O. A. Krohn and D. W. Chandler, J. Phys. Chem. Lett. 15(50), 12455–12463 (2024)]. We refer to the preparation of molecules by this technique as precision ultranarrow-linewidth resonant excitation (PURE) preparation. Here, in this study, we pair this PURE preparation methodology with active frequency stabilization of the quantum cascade laser that drives the excitation. In doing so, highly velocity-resolved packets of molecules are possible, with the limitations of this velocity resolution set by the stability of the laser locking and the spectral linewidth of the transition. We show that side-of-fringe locking to a Doppler-broadened absorption spectrum of our target molecule is sufficiently stable for PURE preparation of molecules for long timescales (several hours) with highly resolved velocity spreads (σ < 3 m/s). To demonstrate the scientific utility of this new capability, we present differential cross sections from scattering between a neat molecular beam of argon and a velocity-selected beam of nitric oxide (NO) in a pure quantum state. We observe well-resolved quantum diffraction oscillations in the forward-scattered collisions as well as general trends consistent with prior characterized collisions of NO + Ar.

Krohn, Olivia A. [Sandia National Laboratories (SN↗

High-Sensitivity rf Detection Using an Optically Pumped Comagnetometer Based on Natural-Abundance Rubidium with Active Ambient-Field Cancellation

To detect a specific radio-frequency (rf) magnetic field, rf optically pumped magnetometers (OPMs) require a static magnetic field to set the Larmor frequency of the atoms equal to the frequency of interest. However, unshielded and variable magnetic field environments (e.g., an rf OPM on a moving platform) pose a problem for rf OPM operation. Here, we demonstrate the use of a natural-abundance rubidium vapor to make a comagnetometer to address this challenge. Our implementation builds upon the simultaneous application of several OPM techniques within the same vapor cell. First, we use a modified implementation of an OPM variometer based on 87 Rb to detect and actively cancel unwanted external fields at frequencies ≲60 Hz using active feedback to a set of field control coils. In this experiment, we exploit this stabilized field environment to implement a high-sensitivity rf magnetometer using 85 Rb. Using this approach, we demonstrate the ability to measure rf fields with a sensitivity of approximately 9 fT Hz -1/2 inside a magnetic shield in the presence of an applied field of approximately 20 μT along three mutually orthogonal directions. This demonstration opens up a path toward completely unshielded operation of a high-sensitivity rf OPM.

47 OTHER INSTRUMENTATION↗

Measurement of longitudinal relaxation times for spin-decoupled protons.

Description of an experimental method for the determination of the longitudinal relaxation time for spin-decoupled protons by a modified version of the saturation recovery technique reported by Van Geet and Hume (1965). The described method should facilitate relaxation studies of chemically shifted protons (or fluorines) and can be applied to more complicated spin systems with the aid of triple resonance and noise-decoupling techniques.

Gerace, M. J.↗

Comparison of two dissimilar modal identification techniques

Recent laboratory results using a refined phase resonance method and the eigensystem realization algorithm on the same test structure are reported. These methods are dissimilar modal identification techniques suitable for future large spacecraft. The theory, application approach, and results obtained for each technique are summarized and compared. Although both methods worked well in this investigation, significant differences occurred in some identified mode shapes. Comparison of independently derived modal parameters provides the means for disclosing such discrepancies in flight projects.

Pappa, Richard S.↗

Demonstration of acoustic monitoring for structural health of microreactors: Through use of neural networks and resonant ultrasound spectroscopy

Nuclear microreactors prioritize modularity and portability and are intended to be a cost-effective technology for non-conventional nuclear markets. As such, the development of microreactors into a safe and feasible solution for energy security applications will necessitate the development of non-destructive technologies to monitor the integrity of inaccessible reactors components during operation. This demonstration applies linear and nonlinear acoustic techniques, in combination with machine learning, to detect and classify mechanical changes (stress and damage) in a test article which are broadly representative of potential operating challenges within a functioning microreactor. All necessary data has been collected for this demonstration, with minor experimental issues identified that can be addressed in follow-on work. Motivated by the expected conditions within a functioning microreactor, we have demonstrated our monitoring techniques on a core-block-like test article using an unstructured excitation source that approximates the noisy acoustic environment expected during reactor operation. At all stress states mechanically applied to the test article, a machine learning model using an artificial neural network was able to classify with 100% accuracy whether a 3D laser vibrometry point measurement was made on an intact or artificially defective test article. Further, model predictions about whether the defect interface was rough or smooth were 95% accurate, indicating the ability of acoustic techniques to recover defect characteristics. Resonant ultrasound spectroscopy (RUS) was also applied to the dataset to provide further quantitative insights about material properties. RUS analysis was ultimately hampered by several minor experimental and data issues, limiting results to certain cases for this demonstration. Last, analysis using nonlinear RUS exhibited sensitivity to changing levels of applied stresses for each intact and defective state. As presented in this demonstration, acoustic monitoring exhibits sensitivity to stress changes, which are of concern due to high thermal gradients expected during startup and operation. Further, our techniques distinguish between measurements made on intact and damaged test articles.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Resonant Ultrasonic Spectroscopy: A Modal-Analysis Approach for Additive Manufacturing

Resonant ultrasonic spectroscopy is a methodology capable of measuring a change in modal resonant frequencies of material structures. It encompasses an inversion technique based on the eigen-frequencies of a simple regular sample geometry to estimate the elastic tensor of a solid. Obtaining an accurate and complete set of resonant frequencies is a critical first step in the RUS process. In this paper a variety of techniques to extract and validate material resonances from complicated RUS measurement spectra are developed. Various processing methodologies employing modal analysis techniques are applied to estimate the underlying resonances that lead to the extraction of the elastic coefficients characterizing the specimen under test. A case study of a simple isotropic material (304 SS) is investigated to analyze the algorithms and evaluate their performance

Coal, lignite, and peat↗

A self diagnostic system for piezoelectric sensors

A technique for determining the mounting conditions of a piezoelectric accelerometer is presented. This technique electrically stimulates the piezoelectric element in the 'diagnostic' frequency band measuring the electrical frequency response characteristics across a capacitive load impedance. The diagnostic frequency band is tipically much higher than the operating bandwidth of the accelerometer. The resonant frequencies of the accelerometer are included in the diagnostic band. By monitoring the shift in these resonant frequencies, via electrical stimulation techniques, certain diagnostic conditions including mounting conditions can be determined. Experimental data from a compression mode accelerometer is used to demonstrate this technique.

Atherton, William J.↗

Effect of an isotropic nonequilibrium plasma on electron temperature measurements.

The electron temperatures that would be determined (using the conventional single-temperature analysis) by the electrostatic probe, the diffuse resonance, and the radar backscatter techniques in an isotropic two-temperature plasma are presented. Plasma models corresponding to the addition of a minor component of energetic electrons and models corresponding to a process that cools a fraction of the ionospheric electrons are considered. The diffuse resonance temperature is found to lie between the probe and radar backscatter temperatures. The isotropic models corresponding to the addition of energetic electrons cannot support the reported discrepancies between radio wave and probe electron temperature measurements. Temperature differences similar to the observed differences can be produced by models with a fraction of the electrons at a temperature cooler than that of the main component of electrons. These models, however, are difficult to explain in terms of present understanding of the ionospheric plasma.

Benson, R. F.↗

Infrared plasmonics: STEM-EELS characterization of Fabry-Pérot resonance damping in gold nanowires

Materials possessing strong midinfrared responses are of current interest because of their potential application to long-wavelength metamaterials, photonic devices, molecular detection, and catalysis. In this work, we utilize high-energy resolution (80 cm -1 , 10 meV) electron-energy-loss spectroscopy (EELS) in a monochromated and aberration-corrected scanning transmission electron microscope (STEM) to resolve multipolar surface plasmon resonances (SPRs), sometimes called Fabry-Pérot (FP) resonances, in gold nanowires with mode energies spanning from ~1000 to 8000 cm -1 . STEM-EELS provides access to these mid- to near-IR responses in a single acquisition, avoiding the difficulties inherent in obtaining the same data using near-field optical techniques. The experimentally measured FP resonance energies and linewidths, together with analytical modeling and full-wave numerical electrodynamics simulations, provide a comprehensive picture of the radiative and intrinsic contributions to the total damping rates. We find some FP modes with dephasing times >60fs, which is almost twice the longest previously reported plasmon dephasing time for individual Au nanoparticles in the infrared. The long dephasing times and the broad tunability of the FP resonance energies throughout the infrared region suggest additional opportunities for harnessing infrared plasmonic energy before dephasing occurs.

36 MATERIALS SCIENCE↗