Search NASA⌕ Search

SEARCH · Search NASA

Results for “Response Spectra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Two-dimensional fourier transform spectrometer

The present invention relates to a system and methods for acquiring two-dimensional Fourier transform (2D FT) spectra. Overlap of a collinear pulse pair and probe induce a molecular response which is collected by spectral dispersion of the signal modulated probe beam. Simultaneous collection of the molecular response, pulse timing and characteristics permit real time phasing and rapid acquisition of spectra. Full spectra are acquired as a function of pulse pair timings and numerically transformed to achieve the full frequency-frequency spectrum. This method demonstrates the ability to acquire information on molecular dynamics, couplings and structure in a simple apparatus. Multi-dimensional methods can be used for diagnostic and analytical measurements in the biological, biomedical, and chemical fields.

47 OTHER INSTRUMENTATION↗

Two-dimensional fourier transform spectrometer

The present invention relates to a system and methods for acquiring two-dimensional Fourier transform (2D FT) spectra. Overlap of a collinear pulse pair and probe induce a molecular response which is collected by spectral dispersion of the signal modulated probe beam. Simultaneous collection of the molecular response, pulse timing and characteristics permit real time phasing and rapid acquisition of spectra. Full spectra are acquired as a function of pulse pair timings and numerically transformed to achieve the full frequency-frequency spectrum. This method demonstrates the ability to acquire information on molecular dynamics, couplings and structure in a simple apparatus. Multi-dimensional methods can be used for diagnostic and analytical measurements in the biological, biomedical, and chemical fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PCF File Format

PCF files are binary files designed to contain gamma spectra and neutron count rates from radiation sensors. It is the native format for the GAmma Detector Response and Analysis Software (GADRAS) package. It can contain multiple spectra and information about each spectrum such as energy calibration. This document outlines the format of the file that would allow one to write a computer program to parse and write such files.

61 RADIATION PROTECTION AND DOSIMETRY↗

Concepts for a theoretical and experimental study of lifting rotor random loads and vibrations, Phase 2

A comparison with NASA conducted simulator studies has shown that the approximate digital method for computing rotor blade flapping responses to random inputs, tentatively suggested in Phase I Report, gives with increasing rotor advance ratio the wrong trend. Consequently, three alternative methods of solution have been considered and are described: (1) an approximate method based on the functional relation between input and output double frequency spectra, (2) a numerical method based on the system responses to deterministic inputs and (3) a perturbation approach. Among these the perturbation method requires the least amount of computation and has been developed in two forms - the first form to obtain the response correlation function and the second for the time averaged spectra of flapping oscillations.

Hohenemser, K. H.↗

Spectra-Orthogonal Optical Anisotropy in Wafer-Scale Molecular Crystal Monolayers

Controlling the spectral and polarization response of two-dimensional (2D) crystals is vital for developing ultrathin platforms for compact optoelectronic devices. However, independently tuning optical anisotropy and spectral response remains challenging in conventional semiconductors due to the intertwined nature of their lattice and electronic structures. Here, we report spectra-orthogonal optical anisotropy─where polarization anisotropy is tuned independently of spectral response─in wafer-scale, one-atom-thick 2D molecular crystal (2DMC) monolayers synthesized on monolayer transition-metal dichalcogenide (TMD) crystals. Utilizing the concomitant spectral consistency and structural tunability of perylene derivatives, we demonstrate tunable optical polarization anisotropy in 2DMCs with similar spectral profiles, as confirmed by room-temperature scanning tunneling microscopy and cross-polarized reflectance microscopy. Additional angle-dependent analysis of the single-crystal and polycrystalline molecular domains reveals an epitaxial relationship between the 2DMC and TMD. In conclusion, our results establish a scalable, molecule-based 2D crystalline platform for unique and tunable functionalities unattainable in covalent 2D solids.

2D materials↗

Flow-generated noise in ducts

A turbulent jet was used to excite high order acoustic modes in a rectangular duct. The measured pressure spectra exhibited asymmetric singularities (pressure spikes) at the cutoff frequencies of the first few transverse modes. In the high frequency limit, where the number of propagating modes is large, the spectra resembles free space jet spectra. The spectra in these limits are determined by the acoustic response of the duct. A linear theoretical analysis, based on an isotropic model of the turbulent fluctuations, is developed to predict this spectra.

Succi, G. P.↗

Excesses in cosmic ray positron and electron spectra from a nearby clump of neutralino dark matter

In this letter, we suggest that a nearby clump of 600-1000 GeV neutralinos may be responsible for the excesses recently observed in the cosmic ray positron and electron spectra by the PAMELA and ATIC experiments. Although neutralino dark matter annihilating throughout the halo of the Milky Way is predicted to produce a softer spectrum than is observed, and violate constraints from cosmic ray antiproton measurements, a large nearby (within 1-2 kiloparsecs of the Solar System) clump of annihilating neutralinos can lead to a spectrum which is consistent with PAMELA and ATIC, while also producing an acceptable antiproton flux. Furthermore, the presence of a large dark matter clump can potentially accommodate the very large annihilation rate required to produce the PAMELA and ATIC signals. We estimate the probability of a sufficiently large clump being present to be {approx}10{sup -3} or less.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Origin of Broad Emission Spectra in InP Quantum Dots: Contributions from Structural and Electronic Disorder

The ensemble emission spectra of colloidal InP quantum dots are broader than achievable spectra of cadmium- and lead-based quantum dots, despite similar single-particle line widths and significant efforts invested in the improvement of synthetic protocols. Here, we seek to explain the origin of persistently broad ensemble emission spectra of colloidal InP quantum dots by investigating the nature of the electronic states responsible for luminescence. We identify a correlation between red-shifted emission spectra and anomalous broadening of the excitation spectra of luminescent InP colloids, suggesting a trap-associated emission pathway in highly emissive core shell quantum dots. Time-resolved pump probe experiments find that s are largely untrapped on photoluminescence relevant time scales pointing to emission from recombination of localized holes with free electrons. Two-dimensional electronic spectroscopy on InP quantum dots reveals multiple emissive states and increased electron phonon coupling associated with hole localization. These localized hole states near the valence band edge are hypothesized to arise from incomplete surface passivation and structural disorder associated with lattice defects. We confirm the presence and effect of lattice disorder by X-ray absorption spectroscopy and Raman scattering measurements. Participation of localized electronic states that are associated with various classes of lattice defects gives rise to phonon-coupled defect related emission. These findings explain the origins of the persistently broad emission spectra of colloidal InP quantum dots and suggest future strategies to narrow ensemble emission lines comparable to what is observed for cadmium-based materials.

36 MATERIALS SCIENCE↗

Chemosensory proteins used as target for screening behaviourally active compounds in the rice pest Cnaphalocrocis medinalis (Lepidoptera: Pyralidae)

Abstract Reverse chemical ecology based on insect functional odorant binding proteins has been extensively studied to screen behaviourally active compounds, whereas chemosensory proteins (CSPs), which are reportedly involved in olfactory chemical reception and could serve as molecular targets remain unclear. In the present study, two behaviourally active compounds for Cnaphalocrocis medinalis , a serious pest of rice in Asia, were successfully screened via an antenna‐biased CSP, CmedCSP33. Fluorescence competitive binding assays showed that CmedCSP33 could bind to seven out of 32 rice volatiles. Fluorescence quenching experiments revealed that CmedCSP33 forms a stable complex with nerolidol and β‐ionone, and circular dichroism (CD) spectra demonstrated that these two compounds cause conformational changes in CmedCSP33. Furthermore, H‐tube olfactometer bioassays showed that C. medinalis displayed prominent attractant responses to nerolidol and prominent repellent responses to β‐ionone. Additionally, binding assays and CD spectra at different pH values implied that extensive conformational changes may be a general feature of CSPs for triggering the subsequent chemical transduction. Overall, our findings provide evidence for the involvement of CSPs in olfactory perception, and a protocol for effectively screening behaviourally active compounds.

Duan, S. ‐G.↗

Application of machine learning techniques for fast MeV x-ray spectra unfolding from filter stack spectrometer data

Recovery of MeV x-ray spectra from detector signals is difficult because the response matrix inversion is ill-conditioned and current methods are too slow for high-repetition-rate experiments. In this work, we make use of neural networks to unfold MeV x-ray spectra from measurements obtained with a filter stack spectrometer at rates of near 40 Hz. The neural network was trained on synthetic data and tested on both synthetic and experimental data, the latter obtained in two separate experiments performed at the Omega EP laser facility. We show here that this unfolding method has good performance on synthetic data and that it is a promising option for experimental data of up to 40 MeV. The accuracy on experimental data is verified by using a simple forward model to compare against measured values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The mystery of spectral breaks: Lyman continuum absorption by photon-photon pair production in the Fermi GeV spectra of bright blazars

We re-analyze Fermi/LAT γ-ray spectra of bright blazars using the new Pass 7 version of the detector response files and detect breaks at ∼5 GeV in the rest-frame spectra of 3C 454.3 and possibly also 4C +21.35, associated with the photon-photon pair production absorption by the He II Lyman continuum (LyC). We also detect significant breaks at ∼20 GeV associated with hydrogen LyC in both the individual spectra and the stacked redshift-corrected spectrum of several bright blazars. The detected breaks in the stacked spectra univocally prove that they are associated with atomic ultraviolet emission features of the quasar broad-line region (BLR). The dominance of the absorption by the hydrogen Ly complex over He II, a small detected optical depth, and break energy consistent with head-on collisions with LyC photons imply that the γ-ray emission site is located within the BLR, but most of the BLR emission comes from a flat disk-like structure producing little opacity. Alternatively, the LyC emission region size might be larger than the BLR size measured from reverberation mapping, and/or the γ-ray emitting region is extended. These solutions would resolve the long-standing issue of how the multi-hundred GeV photons can escape from the emission zone without being absorbed by softer photons.

79 ASTRONOMY AND ASTROPHYSICS↗

Theoretical study on the dynamical correlation in Ar focusing on 3s excitation with outer-shell ionization due to electron impacts

We investigate the energy-loss spectra of high-energy electrons incident on Ar atoms using linear density response theory with a self-interaction correction. The energy region of the spectra covers from 24.5 to 30.0 eV, where many ns, np, and nd autoionizing resonant states from the 3s orbital of Ar exist with the continuum background from the 3p orbital. We compare the calculated spectra to recent energy-loss spectra measurements and identify the observed autoionizing resonant states. We also discuss the dependence of the spectra on the scattering angles and their physical meanings.

74 ATOMIC AND MOLECULAR PHYSICS↗

Rain-Induced Increase in Background Radiation Detected by Radiation Portal Monitors

A complete understanding of both the steady state and transient background measured by Radiation Portal Monitors (RPMs) is essential to predictable system performance, as well as maximization of detection sensitivity. To facilitate this understanding, a test bed for the study of natural background in RPMs has been established at the Oak Ridge National Laboratory. This work was performed in support of the Second Line of Defense Program's mission to detect the illicit movement of nuclear material. In the present work, transient increases in gamma ray counting rates in RPMs due to rain are investigated. The increase in background activity associated with rain, which has been well documented in the field of environmental radioactivity, originates from the atmospheric deposition of two radioactive daughters of radon-222, namely lead-214 and bismuth-214 (henceforth {sup 222}Rn, {sup 214}Pb and {sup 214}Bi). In this study, rainfall rates recorded by a co-located weather station are compared with RPM count rates and High Purity Germanium spectra. The data verifies these radionuclides are responsible for the dominant transient natural background fluctuations in RPMs. Effects on system performance and potential mitigation strategies are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GADRAS-DRF Version 18 User's Manual

The Gamma Detector Response and Analysis Software Detector Response Function (GADRAS-DRF) application computes the response of gamma-ray and neutron detectors to incoming radiation and provides analysis on measured spectra. This manual provides step-by-step procedures to acquaint new users with the use of the application. The capabilities include characterization of detector response parameters, plotting and viewing measured and computed spectra, analyzing spectra to identify isotopes, estimating source energy distributions from measured spectra, and creating inject data. GADRAS-DRF can compute and provide detector responses quickly and accurately, giving users the ability to obtain usable results in a timely manner (a matter of seconds or minutes).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of Isotopic Concentrations and Gamma Spectra from Dynamic Fission Sources

A tool was developed to rapidly generate synthetic gamma-ray spectra to evaluate safeguards material control and accounting methods for liquid-fueled molten salt reactors. Molten salt reactor operations pose unique challenges to nuclear safeguards methods and protocols compared to deployed reactors designs (e.g., light water reactors). This research evaluates the use of gamma-ray spectroscopy to monitor fission product isotopic flow through a reactor model to understand expected operations and investigate changes to the spectra with material diversion scenarios. The large design space of molten salt reactors (e.g., liquid-fueled, liquid-cooled, online separations) could potentially lead to many measurement points within the reactor system. The developed analytical tool generates and evaluates synthetic gamma-ray spectra from dynamic reactor simulations by extracting isotopic inventory to generate source terms. An implementation in the Gamma Detector Response and Analysis Software (GADRAS) Application Program Interface (API) uses the source terms, a model of the reactor component, a detector response function, and measurement plan to quickly generate and analyze spectra. Prospective measurements are then evaluated in the more accurate but slower Geant4 simulations. Utilization of the developed modeling tool and analysis of the subsequent spectra enables optimization of collimation, shielding requirements, and expected count rates that are used to determine key measurement points in the modeled reactor design.

O'Brien, Sean↗

Investigating the Electronic Structure of Fluorite Oxides: Comparsion of EELS and First Principles Calculations

Energy loss spectra from a variety of cubic oxides are compared with ab-initio calculations based on the density functional plane wave method (CASTEP). In order to obtain agreement between experimental and theoretical spectra, unique material specific considerations were taken into account. The spectra were calculated using various approximations to describe core-hole effects and electronic correlations. All the calculations are based on the local spin density approximation to show qualitative agreement with the sensitive oxygen K-edge spectra in ceria, zirconia, and urania. Comparison of experimental and theoretical results let us characterize the main electronic interactions responsible for both the electronic structure and the resulting EEL spectra of the compounds in question.

36 MATERIALS SCIENCE↗

Recover soft x-ray spectrum using virtual flat response channels with filtered x-ray diode array

A method for the recovery of soft x-ray spectra in indirect-drive inertial confinement fusion experiments is presented. Virtual detection channels with bandpass responses are obtained using linear combinations of the channel response functions of a filtered x-ray diode array and a weighted correction is introduced to improve the recovery. These virtual channels can be used to calculate radiation fluxes in some specific photon energy bands and hence to recover the spectrum of the whole photon energy range from 80 eV to 4.5 keV. Examples are listed which demonstrate the capability of this method to unfold various spectra such as Planck spectra with different radiation temperatures and to obtain x-ray flux of certain narrow energy interval.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radial Distribution of Electron Spectra from High-Energy Ions

The average track model describes the response of physical and biological systems using radial dose distribution as the key physical descriptor. We report on an extension of this model to describe the average distribution of electron spectra as a function of radial distance from an ion. We present calculations of these spectra for ions of identical linear energy transfer (LET), but dissimilar charge and velocity to evaluate the differences in electron spectra from these ions. To illustrate the usefulness of the radial electron spectra for describing effects that are not described by electron dose, we consider the evaluation of the indirect events in microdosimetric distributions for ions. We show that folding our average electron spectra model with experimentally determined frequency distributions for photons or electrons provides a good representation of radial event spectra from high-energy ions in 0.5-2 micrometer sites.

Cucinotta, Francis A.↗