Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

CosmoSIS: Modular cosmological parameter estimation

Cosmological parameter estimation is entering a new era. Large collaborations need to coordinate high-stakes analyses using multiple methods; furthermore such analyses have grown in complexity due to sophisticated models of cosmology and systematic uncertainties. In this paper we argue that modularity is the key to addressing these challenges: calculations should be broken up into interchangeable modular units with inputs and outputs clearly defined. Here we present a new framework for cosmological parameter estimation, CosmoSIS, designed to connect together, share, and advance development of inference tools across the community. We describe the modules already available in CosmoSIS, including CAMB, Planck, cosmic shear calculations, and a suite of samplers. Lastly, we illustrate it using demonstration code that you can run out-of-the-box with the installer available at http://bitbucket.org/joezuntz/cosmosis

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating the efficacy of DGT to quantify copper in stormwater at end-of-pipe

In many cases, stormwater compliance monitoring is labor intensive, expensive, and largely unsuccessful in providing the data needed to support stormwater management goals. To help address these issues, diffusive gradients in thin film (DGTs), time-integrative passive samplers for metals, were evaluated to monitor copper in stormwater runoff. DGTs were co-located with traditional autosamplers within the stormwater conveyance systems at Naval Base San Diego (NBSD) to provide a direct comparison with composite sampling. DGTs were exposed in the laboratory to flow-averaged composite samples from NBSD stormwater conveyance systems. These experiments showed increasing uptake over time (range = 1.5 to 24 h) for copper, with positive, linear correlations (r2>0.980) between exposure duration and copper mass accumulated. However, it appears that the corresponding calculations of the DGT-labile fraction (CDGT) relative to the dissolved fraction fluctuated across the different exposure durations. In general, trends observed for CDGT measurements from the field were consistent with trends in the lab DGT exposures and traditional dissolved metal measurements from composite samples. Finally, time-weighted average copper concentrations from DGTs deployed for the first and second parts of storm events were within 30% of measurements from DGTs that were deployed for the entire storm event in the same stormwater vault. Cumulatively, these results show promise for continuous monitoring with DGTs as an approach that produces data more representative of exposure to the receiving environment during episodic events than data from traditional grab or composite chemistry sampling, and can represent significant cost savings.

Diffusive Gradient in Thin Films, stormwater, trac↗

Multi-fidelity classification using Gaussian processes: Accelerating the prediction of large-scale computational models

We report that machine learning techniques typically rely on large datasets to create accurate classifiers. However, there are situations when data is scarce and expensive to acquire. This is the case of studies that rely on state-of-the-art computational models which typically take days to run, thus hindering the potential of machine learning tools. In this work, we present a novel classifier that takes advantage of lower fidelity models and inexpensive approximations to predict the binary output of expensive computer simulations. We postulate an autoregressive model between the different levels of fidelity with Gaussian process priors. We adopt a fully Bayesian treatment for the hyper-parameters and use Markov Chain Monte Carlo samplers. We take advantage of the probabilistic nature of the classifier to implement active learning strategies. We also introduce a sparse approximation to enhance the ability of the multi-fidelity classifier to handle a large amount of low fidelity samples. We test these multi-fidelity classifiers against their single-fidelity counterpart with synthetic data, showing a median computational cost reduction of 23% for a target accuracy of 90%. In an application to cardiac electrophysiology, the multi-fidelity classifier achieves an F1 score, the harmonic mean of precision and recall, of 99.6% compared to 74.1% of a single-fidelity classifier when both are trained with 50 samples. In general, our results show that the multi-fidelity classifiers outperform their single-fidelity counterpart in terms of accuracy in all cases. Finally, we envision that this new tool will enable researchers to study classification problems that would otherwise be prohibitively expensive. Source code is available at https://github.com/fsahli/MFclass.

97 MATHEMATICS AND COMPUTING↗

Particlization in fluid dynamical simulations of heavy-ion collisions: The IS3D module

The IS3D particlization module simulates the emission of hadrons from heavy-ion collisions via Monte-Carlo sampling of the Cooper–Frye formula which converts fluid dynamical information into local phase-space distributions for hadrons. The code package includes multiple choices for the non-equilibrium correction to these distribution functions: the 14-moment approximation, first-order Chapman–Enskog expansion, and two types of modified equilibrium distributions. This makes it possible to explore to what extent heavy-ion experimental data are sensitive to different choices for δf n , presently the main source of theoretical uncertainty in the particlization stage. Here, we validate our particle sampler with a high degree of precision by generating several million hadron emission events from a longitudinally boost-invariant hypersurface and comparing the event-averaged particle spectra and space–time distributions to the Cooper–Frye formula.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-level Monte Carlo methods in chemical applications with Lennard-Jones potentials and other landscapes with isolated singularities

We describe and compare outcomes of various Multi-Level Monte Carlo (MLMC) method variants, motivated by the potential of improved computational efficiency over rejection based Monte Carlo, which scales poorly with problem dimension. With an eye toward its application to computational chemical physics, we test MLMC's ability to sample trajectories on two problems — a familiar double-well potential, with known stationary distributions, and a Lennard-Jones solid potential (a Galton Board). By sampling Brownian motion trajectories, we are able to compute expectations of observable averages. These multi-basin potential energy problems capture the essence of the challenges with using MLMC, namely, maintaining correspondence of sample paths as time-resolution is varied. Addressing this challenge properly can lead to MLMC significantly outperforming standard Monte Carlo path sampling. We describe the essence of this problem and suggest strategies that circumvent diverging multilevel sample paths for an important class of problems. In the tests we also compare the computational cost of several, “adaptive,” variants of MLMC. Our results demonstrate that MLMC overcomes the collision, time scale limitation of the more familiar Brownian path MC samplers, and our implementation provides tunable error thresholds, making MLMC a promising candidate for application to larger and more complex molecular systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Personal and environmental predictors of polycyclic aromatic hydrocarbon exposure identified through repeated silicone wristband sampling

This study integrates quantitative data on personal exposure to polycyclic aromatic hydrocarbons (PAHs) in 162 silicone wristbands with demographics, behavioral information, and housing characteristics to explore contributions to residential exposure in a superfund-adjacent community over the course of a year. Forty-six residents completed questionnaires and wore silicone wristbands as personal passive samplers for seven consecutive days on up to four separate occasions in alternating months between November 2022 and June 2023. It was hypothesized that individual behaviors and housing characteristics are sources of dependence and correlation between personal PAH exposures. 50 PAHs were detected at least once, 17 of which were alkylated PAHs. Exposure to PAHs of similar molecular weight was often correlated, notably between naphthalenes (2-rings) and higher molecular weight PAHs (3 or more rings). Generalized linear mixed models identified flooring type, participant age, and sampling month as important predictors of increased PAH exposure, and flooring type, and use of wood stoves or heavy machinery as predictors of increased naphthalene exposure relative to higher molecular weight PAHs. Individual chemical models based on concentration data and detection frequencies corroborated these findings across multiple PAHs. We demonstrate that personal exposure is not static and the degree of variability in personal exposure is individual. Hence, identification of influential exposure factors through repeated measures of chemical exposure and characterization of variability in personal exposure as performed in this study, is important in the development of exposure mitigation strategies.

Bonner, Emily↗

Induction of IL-6 and inhibition of IL-8 secretion in the human airway cell line Calu-3 by urban particulate matter collected with a modified method of PM sampling

Exposure to particulate matter (PM) induces inflammatory cytokines. In the present study, we evaluated the secretion of IL-6 and IL-8 by an airway cell line exposed to PM with a mean aerodynamic size equal to or less than 10 or 2.5 {mu}m (PM{sub 10} and PM{sub 2.5}, respectively) collected in Mexico City, using a modified high-volume sampling method avoiding the use of solvents or introducing membrane components into the samples. PM was collected on cellulose-nitrate (CN) membranes modified for collection on high-volume samplers. Composition of the particles was evaluated by particle-induced X-ray emission (PIXE) and scanning electron microscopy. The particles (10-160 {mu}g/cm{sup 2}) were tested on Calu-3 cells. Control cultures were exposed to LPS (10 ng/mL to 100 {mu}g/mL) or silica (10-160 {mu}g/cm{sup 2}). IL-6 and IL-8 secretions were evaluated by ELISA. An average of 10 mg of PM was recovered form each cellulose-nitrate filter. No evidence of contamination from the filter was found. Cells exposed to PM{sub 10} presented an increase in the secretion of IL-6 (up to 400%), while IL-8 decreased (from 40% to levels below the detection limit). A similar but weaker effect was observed with PM{sub 2.5}. In conclusion, our modified sampling method provides a large amount of urban PM free of membrane contamination. The urban particles induce a decrease in IL-8 secretion that contrasts with the LPS and silica effects. These results suggest that the regulation of IL-8 expression is different for urban particles (complex mixture containing combustion-related particles, soil and biologic components) than for biogenic compounds or pure mineral particles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep root activity overprints weathering of petrogenic organic carbon in shale

The oxidation of organic carbon in sedimentary bedrock (petrogenic OC, OC petro ) is increasingly recognized as a potential source of CO 2 to the atmosphere. Recent studies provide evidence for the mobilization and oxidation of OC petro in sedimentary bedrock during rock weathering. However, the mechanisms and rates remain uncertain, particularly where overlying soils and vegetation drive contemporaneous oxidation of recently fixed organic carbon. Here, in this study, we quantify OC petro weathering across a 16 m shale depth profile in a steep, rapidly eroding forested hillslope in the Northern California Coast Ranges. We report solid and gas phase radiocarbon and stable isotope analyses of samples extracted from specialized in-situ samplers, and a supporting laboratory incubation experiment of the shale regolith. OC petro is removed from the weathered bedrock at a rate of approximately 0.12 gC/m 3 yr, which is orders of magnitude lower than the rate of OC petro oxidation we achieved in the laboratory with crushed samples (557.1 gC/m 3 yr). This disparity occurs despite high O 2(g) content across the depth profile, indicating that physical accessibility of OC petro can regulate oxidative weathering. There is no direct radiocarbon evidence of OC petro oxidation in CO 2(g) across the upper 13 m of the weathering profile during both wet and dry seasons. Instead, vadose zone CO 2(g) production at the site is dominated by respiration of recently fixed carbon associated with deep rooting. OC petro is clearly mobilized across the vadose zone during weathering in this rapidly eroding, oxygen-rich, biologically dynamic hillslope, but at rates far below what can be measured given the contribution of root-derived CO 2(g) .

58 GEOSCIENCES↗

An adaptive Hessian approximated stochastic gradient MCMC method

Bayesian approaches have been successfully integrated into training deep neural networks. One popular family is stochastic gradient Markov chain Monte Carlo methods (SG-MCMC), which have gained increasing interest due to their ability to handle large datasets and the potential to avoid overfitting. Although standard SG-MCMC methods have shown great performance in a variety of problems, they may be inefficient when the random variables in the target posterior densities have scale differences or are highly correlated. Here, we present an adaptive Hessian approximated stochastic gradient MCMC method to incorporate local geometric information while sampling from the posterior. The idea is to apply stochastic approximation (SA) to sequentially update a preconditioning matrix at each iteration. The preconditioner possesses second-order information and can guide the random walk of a sampler efficiently. Instead of computing and saving the full Hessian of the log posterior, we use limited memory of the samples and their stochastic gradients to approximate the inverse Hessian-vector multiplication in the updating formula. Moreover, by smoothly optimizing the preconditioning matrix via SA, our proposed algorithm can asymptotically converge to the target distribution with a controllable bias under mild conditions. To reduce the training and testing computational burden, we adopt a magnitude-based weight pruning method to enforce the sparsity of the network. Our method is user-friendly and demonstrates better learning results compared to standard SG-MCMC updating rules. The approximation of inverse Hessian alleviates storage and computational complexities for large dimensional models. Numerical experiments are performed on several problems, including sampling from 2D correlated distribution, synthetic regression problems, and learning the numerical solutions of heterogeneous elliptic PDE. The numerical results demonstrate great improvement in both the convergence rate and accuracy.

97 MATHEMATICS AND COMPUTING↗

Efficient Bayesian inference with latent Hamiltonian neural networks in No-U-Turn Sampling

When sampling for Bayesian inference, one popular approach in the computational field is to use Hamiltonian Monte Carlo (HMC) and specifically the No-U-Turn Sampler (NUTS), which automatically decides the end time of the Hamiltonian trajectory. However, HMC and NUTS can require numerous numerical gradients of the target density and can prove slow in practice when relying on computationally expensive forward models. We propose Latent Hamiltonian neural networks (L-HNNs) with HMC and NUTS for solving Bayesian inference problems. Once trained, L-HNNs do not require numerical gradients of the target density during sampling, and hence numerous evaluations of the forward computational model. Moreover, L-HNNs satisfy important properties such as perfect time reversibility and Hamiltonian conservation, making them well-suited for use within HMC and NUTS because stationarity can be shown. We also propose the integration of L-HNNs in an online error monitoring scheme, in which numerical gradients of the target density are used for a few samples whenever the L-HNNs prediction errors are large. This online error monitor scheme prevents sample degeneracy in regions of low probability density and ensures robust uncertainty quantification. We demonstrate L-HNNs in NUTS with online error monitoring on several analytical examples involving complex, heavy-tailed, and high-local-curvature probability densities. We then demonstrate the applicability of L-HNNs in NUTS to two computational case studies, namely the Allen-Cahn stochastic partial differential equation and an elliptic partial differential equation with 25 and 50 inference parameters, respectively. Overall, the L-HNNs in NUTS with online error monitoring satisfactorily inferred these probability densities. In conclusion, compared to traditional NUTS, L-HNNs in NUTS with online error monitoring required 1–2 orders of magnitude fewer numerical gradients of the target density and improved the effective sample size (ESS) per gradient (which is a measure of both the sampling quality and the computational expense) by an order of magnitude.

97 MATHEMATICS AND COMPUTING↗

Aerosol Sample Inhomogeneity with Debris from the Fukushima Daiichi Nuclear Accident

Radionuclide aerosol sampling is a vital component in the detection of nuclear explosions, nuclear accidents, and other radiation releases. This was proven by the detection and tracking of emissions from the Fukushima Daiichi incident across the globe by IMS stations. Two separate aerosol samplers were operated in Richland, WA following the event and debris from the accident were measured at levels well above detection limits. While the atmospheric activity concentration of radionuclides generally compared well between the two stations, they did not agree within uncertainties. This paper includes a detailed study of the aerosol sample homogeneity of 134 Cs and 137 Cs, then relates it to the overall uncertainty of the original measurement. Our results show that sample inhomogeneity adds an additional 5–10% uncertainty to each aerosol measurement and that this uncertainty is in the same range as the discrepancies between the two aerosol sample measurements from Richland, WA.

Gomez, Reynaido↗

Utility of Atmospheric Transport Runs Done Backwards in Time for Source Term Estimation

In a general sense, the equations describing transport of an atmospheric contaminant are reversible in time. However, the time reversibility is not perfect. For a source term estimation problem, one atmospheric transport model (ATM) run done backwards in time to represent the influence of a single sample value can yield as much information as hundreds or thousands of forwards ATM runs. Thus, backwards ATM are often used to limit the computational burden of an analysis. A large number of paired ATM runs at 14 release locations were used to explore the agreement between dilution factors for the forward and backwards time directions. Four of the release locations have correlation coefficients between forward and backwards dilution factors greater than 0.9. None of the four have large elevation changes within 100 km of the release location. The two release locations with the lowest correlation coefficients are in mountainous terrain with large elevation differences. Elevation changes have a greater negative influence on the correlations than distance to the sampler or plume transit times. The locations of the releases were estimated using dilution factors from backwards ATM runs. Many of the location estimates are close to the release point, vindicating the general approach of using ATM runs backwards in time. Aggregated over the 14 release points, 26% of the location estimates were within 10 km of the release point, 61% were within 25 km, 80% were within 50 km, and 87% were within 75 km. Most of the remaining 13% (poor matches) occur for two release locations in mountainous terrain. Good time-reversibility cannot be guaranteed for a new analysis, so we recommend that any source term solution using backwards ATM runs should include comparisons based on forward ATM runs. As an example, calculations show good agreement between dilutions in different time-directions for samples taken after the announced nuclear test by the Democratic People’s Republic of Korea in 2013.

Eslinger, Paul W.↗

Comparison of near-background concentrations of Argon-37 and Xenon-133 in the Atmosphere

Radioisotopes of noble gases xenon and argon can be important indicators of underground nuclear explosions. The Comprehensive Nuclear-Test-Ban Treaty (CTBT) includes monitoring capabilities to identify potential nuclear explosions conducted in violation of the CTBT. This monitoring currently focuses on measurement of the xenon isotopes 133Xe, 135Xe, 131mXe and 133mXe. However, it is predicted that within 100 days of an underground nuclear explosion (UNE) 37Ar would be released to the atmosphere at higher concentrations than xenon isotopes (Haas et al. 2010) and with a higher signal to background ratio, depending on the radioxenon background levels. Therefore, inclusion of 37Ar measurement capabilities at atmospheric International Monitoring System (IMS) stations may represent an improvement in the capability to detect a nuclear explosion. At an IMS station, it could be difficult to determine what constitutes an elevated concentration as a result of an UNE without first understanding the expected range of background concentrations. This work describes our analysis of atmospheric samples for 37Ar to evaluate the range of background concentrations. Samples were collected at multiple locations, with approximately half coming from a sampler co-located with an IMS xenon monitoring station (RN75). The range of 37Ar concentrations measured in atmospheric air samples was relatively narrow; for samples considered detectable, the minimum and maximum measured concentrations were 0.56 and 2.3 mBq/m3, respectively. Comparison of 37Ar and 133Xe concentrations measured at the IMS station indicated some correlation between the measured concentrations. The results presented here demonstrate the capability to detect background concentrations of 37Ar in atmospheric air and provide a basis for potential implementation of 37Ar monitoring at IMS stations.

Fritz, Brad G.↗

Using STAX data to predict IMS radioxenon concentrations

The noble gas collection and measurement stations in the International Monitoring System (IMS) are heavily influenced by releases from medical isotope production facilities. The ability to reliably model the movement of radioxenon from the points of release to these IMS samplers has improved enough that a routine aspect of the analysis of IMS radioxenon data should be the prediction of the effect of releases from civilian nuclear facilities on the sample concentrations. In this work, predicted concentrations at IMS noble gas systems in Germany and Sweden based on measured releases from Institute for Radioelements (IRE) in Belgium and atmospheric transport modeling for a four-month period are presented and discussed.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Projected network performance for next-generation xenon monitoring systems

Next-generation radioxenon monitoring systems are reaching maturity and are expected to improve certain aspects of performance in verifying the absence of nuclear tests. To predict the improvement in detecting and locating nuclear releases, thousands of releases all over the globe were simulated and the global detection probability was calculated. This was done for the International Monitoring System network of noble gas samplers as it currently exists (25 certified stations), and how it would be for potential future network sizes of 39 and 79 stations. The probability of detection was calculated for releases ranging from 10 10 Bq to 10 16 Bq of 133 Xe and presented as coverage maps and global integrals for both current and next-generation monitoring systems. Similarly, the number of detecting stations and the number of detecting samples were tabulated to elucidate the possibilities for enhanced location capability. Improvements in global detection coverage are maximized at different release sizes in a way that depends on the station density. For example, for releases of 3×10 14 Bq and 39 stations, the detection probability would rise from 60% to 70% with next-generation systems, while for releases of 10 13 Bq and 79 stations, it would rise from 37% to 52%. Achieving an average of two detecting stations requires a 1015 Bq release for a 39-station network and a 10 14 Bq release for a 79-station network. The largest impact of using next-generation systems may be the confidence, failure tolerance, and location capability that arise from obtaining multiple samples associated with a single release event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Source term estimation using noble gas and aerosol samples

Algorithms that estimate the location, time, and magnitude of a point-source atmospheric release using remotely sampled air concentrations typically use data for a single chemical or radioactive isotope. Here, a Bayesian algorithm is presented that uses data from multiple radioactive isotopes that are all released in the same short-duration event. Data from noble gas and aerosol samplers can be used simultaneously in the model. Application to a large synthetic data set using four isotopes shows the new algorithm generally gives more accurate location and time estimates than a comparable model using a single isotope.

54 ENVIRONMENTAL SCIENCES↗

Detecting 127 Xe in an atmospheric tracer experiment

The Xcounts algorithm for calculating air concentrations of radioactive xenon isotopes (Eslinger et al., 2023) has been extended to estimate 127 Xe in addition to 131m Xe, 133m Xe, 133 Xe, and 135 Xe. The algorithm was applied to 119 samples collected with a SAUNA Q B system (Ringbom et al., 2023) during a two-month atmospheric tracer release experiment. Finally, the algorithm identified two samples with 127 Xe present from a single 1.5 h release about 3.5 km upwind of the sampler and no false detections of 127 Xe were observed in the other samples.

127Xe calibration↗