Evidence of a halo formation mechanism in the Spallation Neutron Source linac
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Not Available
Explore the source record for details and available documents.
Visualizing hydrogen atoms in biological materials is one of the biggest remaining challenges in biophysical analysis. While X-ray techniques have unrivaled capacity for high-throughput structure determination, neutron diffraction is uniquely sensitive to hydrogen atom positions in crystals of biological materials and can provide a more complete picture of the atomic and electronic structures of biological macromolecules. This information can be essential in providing predictive understanding and engineering control of key biological processes, for example, in catalysis, ligand binding and light harvesting, and to guide bioengineering of enzymes and drug design. One very common and large capability gap for all neutron atomic resolution single-crystal diffractometers is the weak flux of available neutron beams, which results in limited signal-to-noise ratios giving a requirement for sample volumes of at least 0.1 mm 3 . The ability to operate on crystals an order of magnitude smaller (0.01 mm 3 ) will open up new and more complex systems to studies with neutrons which will help in our understanding of enzyme mechanisms and enable us to improve drugs against multi resistant bacteria. With this is mind, an extended wide-angle Laue diffractometer, `Ewald', has been designed, which can collect data using crystal volumes below 0.01 mm 3 .
The AT-HVCM, achieved by series-stacking the dual-function resonant filter capacitors following each rectification stage, is the baseline design for the PPU project at the SNS [1]. The project requires three AT-HVCM modulators to power 28 additional 700kW klystrons and associated high beta cavities to accelerate 38mA of beam current to 1.3GeV. Each modulator produces an 82 kV, 120A output pulse of 1.35ms duration at a 60Hz repetition rate. The AT design approach improves upon the existing HVCM topology, reducing stresses on the H bridge IGBTs using zero voltage (ZVS) and current switching (ZCS) techniques and on the resonant filter capacitors by limiting voltage reversal. This paper reviews the prototype development progress, currently focused on evaluating system reliability, and discusses some design techniques to achieve the modulator performance requirements.
Prompted by the need for radiation-resistant permanent magnets for insertion devices (IDs) of high-brilliance next-generation synchrotrons such as the National Synchrotron Light Source II, the demagnetization of Nd 2 Fe 14 B and Pr 2 Fe 14 B was studied after exposure to a mixed irradiating field. Degradation and damage of the permanent magnetic material by components of electromagnetic showers induced in magnets by intense high-energy electron beams will alter the magnetic field structure of the IDs. Plate-like Nd 2 Fe 14 B magnets were irradiated to 1.8 Grad dose and were evaluated against Pr 2 Fe 14 B magnets irradiated to a lower dose of 20 Mrad. In addition, annular Sm 2 Co 17 and Nd 2 Fe 14 B magnets integrated within a ferrofluidic feedthrough (FFFT) rotary seal were also irradiated to dose levels of 2 Grad for Sm 2 Co 17 and 20 Mrad for Nd 2 Fe 14 B. Post-irradiation measurements of the magnetic intensity revealed that severe demagnetization exceeding 85% occurs in Nd 2 Fe 14 B magnets after only 50 Mrad dose and over 87% for Pr 2 Fe 14 B after 10 Mrad dose. The annular-shaped Sm 2 Co 17 magnets of the FFFTs were almost insensitive to irradiation up to a dose of 2 Grad. Annular-shaped Nd 2 Fe 14 B magnets also showed resistance to demagnetization, a direct consequence of the annular shape which is characterized by the removal of the stronger demagnetizing field present at the center of a disk-like magnet. As a result, the sensitivity of boron-based permanent magnets to neutron energy (thermal versus fast) was also assessed via specifically designed experiments and discussed.
Cosmogenic high-energy neutrons are a ubiquitous, difficult to shield, poorly measured background. Above ground the high-energy neutron energy-dependent flux has been measured, with significantly varying results. Below ground, high-energy neutron fluxes are largely unmeasured. Here we present a reconstruction algorithm to unfold the incident neutron energy-dependent flux measured using the Multiplicity and Recoil Spectrometer (MARS), simulated test cases to verify the algorithm, and provide a new measurement of the above ground high-energy neutron energy-dependent flux with a detailed systematic uncertainty analysis. Uncertainty estimates are provided based upon the measurement statistics, the incident angular distribution, the surrounding environment of the Monte Carlo model, and the MARS triggering efficiency. Quantified systematic uncertainty is dominated by the assumed incident neutron angular distribution and surrounding environment of the Monte Carlo model. The energy-dependent neutron flux between 90 MeV and 400 MeV is reported. Between 90 MeV and 250 MeV the MARS results are comparable to previous Bonner sphere measurements. Over the total energy regime measured, the MARS result are located within the span of previous measurements. Lastly, these results demonstrate the feasibility of future below ground measurements with MARS.
An mcpl of simulated neutron events captured at a location 20 cm upstream of the sample position.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We describe the ongoing efforts to apply Machine Learning techniques to improve the performance of our accelerator and target. Specially, we are looking to minimize halo beam losses in the absence of a proper physics model, automatically detect and log anomalies in the target support systems such as cooling, and detect and prevent errant beam pulses in the linac. We also describe the infrastructure we use to acquire and stream data to the GPU cluster for training, our code development cycle, and edge computing for model inference. To minimize halo beam losses, we use a Reinforcement Learning technique tested on a virtual accelerator. The target anomaly detection is trained on archived data using incomplete physics models and is made part of the existing target reporting system. The errant beam prevention analyzes beam current and beam phase waveforms as well as accelerator configuration data to predict errant pulses. We also develop continual learning to adapt to changes in the accelerator.
The aim of this work is to extend CEM and LAQGSM for a more accurate prediction of high-energy LF by Monte Carlo N-Particle Transport Code version 6 (MCNP6).
The aim of our work is to extend the precompound model in them to include emission of light fragments up to 28 Mg, leading to an increase of predictive power of LF- production in MCNP6.
Los Alamos National Laboratory (LANL) is the location of the Los Alamos Neutron Science Center (LANSCE). The presentation outlines the various components and capabilities at LANSCE.
This brochure is an abridged version of a more comprehensive companion report. DOE proposes to build a Second Target Station (STS) at SNS to produce beams of cold neutrons with world-leading peak brightness at a repetition rate of 15 Hz, providing broad energy/wavelength ranges that can be used simultaneously. Construction of the STS will provide transformative capabilities that allow thousands of users from national laboratories, universities, and industry to address grand scientific challenges [Hemminger 2015], advance energy research, and accelerate industrial innovations through the combination of cold (long-wavelength) neutrons of unprecedented peak brightness and short neutron pulses with broad ranges of usable wavelengths or energy. The STS Project, now in progress at ORNL, will design, construct, install, and commission the facilities and equipment needed to create a world-leading source of cold neutrons of unprecedented peak brightness at SNS. Key aspects of the STS design, including preliminary descriptions of an illustrative suite of eight instruments, are presented in the section “The STS at SNS.” The capabilities offered by the STS instruments (22 when fully built out) will complement those of the FTS and HFIR, providing the United States with unparalleled resources for neutron scattering at the world’s leading high–peak brightness cold neutron source.
Abstract not provided.
The importance of actinides for science, technology, and medicine is widely recognized and does not require a lengthy introduction. However, the fundamental understanding of actinides and their chemical and physical properties lags behind the knowledge of most other elements in the periodic table. Most actinides (89 ≤ Z ≤ 103) are man-made and were produced in particle accelerators or nuclear reactors in the second half of the 20th century. Although trends in bonding and electronic structure are well characterized and documented across the periodic table, fundamental questions remain regarding the chemistry and physics of the actinides. This lack of knowledge is largely because most isotopes of actinides are intensely radioactive, which greatly increases the difficultly in handling them.