Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Quantitation of Trace Water in ISS Atmosphere Samples Recovered from CO2-Removal Systems

As crewed spaceflight continues to push the limits of exploration, instruments and hardware used to maintain and monitor crew and vehicle health, must become more integrated, reliable, and efficient. By combining a carbon dioxide (CO2) removal system with a resource recovery system like a Sabatier or Bosch reactor, the waste gas from the removal system can be converted into valuable resources that help reduce reliance on ground resupply. Due to the high-pressure nature of the Sabatier and Bosch reactions, the vent gas from most CO2 removal systems will need to be compressed before it can be processed. In order to prevent condensation in the compressor of the recovery system, it is critical to ensure that the vent stream from the CO2 removal system does not contain an excess of water. There are currently two different CO2 removal systems that are being developed as candidates for exploration missions. Each of these systems will be evaluated as a technology demonstration on ISS, and vent gas samples will be collected in Summa sampling canisters fitted with Entech valves for ground analysis. Due to the need to measure low levels of water in these samples, it was not possible to use the current ISS mini-grab sample containers (m-GSC) to collect these samples. The Summa containers, which were used to collect archive samples during Shuttle missions, have a different surface treatment that makes it possible to measure the low levels of water in samples collected in these containers. This paper will provide some background on the CO2 removal systems being evaluated for exploration missions as well as results from ground-based testing of the Summa canisters. Details on the development of the analytical method and the plan for preparing the canisters that will be used for in-flight sampling are also discussed.

William M. King↗

Processing Frozen Apollo Samples in a Nitrogen Environment

A few weeks after their return to Earth, several Apollo 17 regolith sample splits and one Apollo 17 basalt were frozen at -20˚C (under dry gaseous N2 like all other pristine Apollo samples), and have remained essentially unstudied within the Apollo sample collection at NASA’s Johnson Space Center (JSC). As part of the Apollo Next Generation Sample Analysis (ANGSA) project, these frozen samples were selected for consortium study in 2019. Although the samples themselves were kept at -20˚C for nearly 50 years, the JSC Curation office has lacked a facility for processing frozen samples under pristine Apollo processing conditions. A temporary lab for this work was designed, built, and tested. Procedures were then developed for working in this unique environment, and the facility was sucessfully used to process the frozen Apollo samples for scientific allocation.

ANGSA↗

Sampling Functions from Gaussian Processes and Structured Covariance Gaussian Networks

When learning aerodynamic models from data, it is critical to incorporate estimates of model uncertainty. This motivates the design of probabilistic aerodynamic databases which can be sampled to generate physically and statistically plausible aerodynamic models. In this talk we discuss how to sample deterministic functions from two different kinds of probabilistic models and demonstrate their use. First, Gaussian Process Regressors (GPRs) are a widely used probabilistic kernel-based model which can be thought of as Gaussian distributions over functions. GPRs are generally trained by maximizing the marginal likelihood of seeing the training data over the kernel parameter space. Sample functions are easily generated by drawing points from the Gaussian distribution at desired input points. However, when the points are not known ahead of time, the classical sampling approach is not possible since successive function samples will generate different function realizations. We present an approach for sampling consistent function evaluations from a GPR over multiple samples. Second, we describe a neural network architecture which learns a conditional Gaussian distribution by maximizing the marginal likelihood at each point in the input space. We then discuss and compare several options for generating sample functions which match this distribution. Finally, we demonstrate the use of these probabilistic aerodynamic models in an atmospheric reentry simulation.

Gaussian process regression↗

Evolved Gas Analyses of Sedimentary Rocks from the Glen Torridon Clay-Bearing Unit, Gale Crater, Mars: Results From the Mars Science Laboratory Sample Analysis at Mars Instrument Suite

Evolved gas analysis (EGA) data from the Sample Analysis at Mars (SAM) instrument suite indicated Fe-rich smectite, carbonate, oxidized organics, Fe/Mg sulfate, and chloride in sedimentary rocks from the Glen Torridon (GT) region of Gale crater that displayed phyllosilicate spectral signatures from orbit. SAM evolved H2O data indicated that the primary phyllosilicate in all GT samples was an Fe-rich dioctahedral smectite (e.g., nontronite) with lesser amounts of a phyllosilicate such as mixed layer talc-serpentine or greenalite-minnesotaite. CO(2) data supported the identification of siderite in several samples, and CO(2) and CO data was also consistent with trace oxidized organic compounds such as oxalate salts. SO(2) data indicated trace and/or amorphous Fe sulfates in all samples and one sample may contain Fe sulfides. SO(2) data points to significant Mg sulfates in two samples, and lesser amounts in several other samples. A lack of evolved O(2) indicated the absence of oxychlorine salts and Mn3+/Mn4+ oxides. The lack of, or very minor, evolved NO revealed absent or very trace nitrate/nitrite salts. HCl data suggested chloride salts in GT samples. Constraints from EGA data on mineralogy and chemistry indicated that the environmental history of GT involved alteration with fluids of variable redox potential, chemistry and pH under a range of fluid-to-rock ratio conditions. Several of the fluid episodes could have provided habitable environmental conditions and carbon would have been available to any past microbes though the lack of significant N could have been a limiting factor for microbial habitability in the GT region.

A. C. McAdam↗

Optimizing Single Nuclei Sequencing of Brain Samples From Space Flown Mice Across Age and Strain

The NASA GeneLab Sample Processing Laboratory offers high-throughput sequencing services to NASA-funded space biology researchers. Space biology studies have specific challenges such as low sample numbers, introducing susceptibility to batch effects from sample handling. These issues are compounded by complex protocols such as single-nuclei isolation and sequencing, which has recently become an attractive methodology for assessing the cellular diversity within spaceflight samples. High quality single-nuclei sequencing requires reproducible protocols to dissociate tissue and generate clean suspension of intact single nuclei. Producing single-nuclei suspension from brain tissue is particularly challenging due to cell type heterogeneity and the myelin sheath that carries over into the nuclei suspension as debris. Current procedures tend to be time consuming and sometimes include steps that can alter gene expression and create cell-type bias. Commercially available nuclei isolation kits, such as the 10X Genomics nuclei isolation kit, offers a streamlined way to process samples for nuclei isolation, thereby minimizing batch effects and enabling reproducibility. In this study, we report on the performance of the 10X Genomics nuclei isolation kit and Chromium Next GEM Single Cell Multiome ATAC + Gene Expression kit to generate sequencing libraries from space-flown mouse brain samples. Single nuclei sequencing was performed on frozen mouse brain tissue from two spaceflight missions, Rodent Research-10 (RR-10) and RR Reference Mission-2 (RRRM-2). RR-10 mice were female B6129SF2/J, euthanized at 18-19 weeks whereas RRRM-2 mice were female C57BL/6NTac, euthanized at 20 or 37 weeks. Sequencing data was processed using standard GeneLab data processing pipelines. We report evaluation of the performance of the 10X Genomics nuclei isolation kit for spaceflight samples from mouse brain, and evaluation of reproducibility across different mouse strains and age groups. We also report preliminary scientific results including cell type inference, cell clustering, and differentially expressed genes and pathways between spaceflight and ground control samples.

RR-10↗

Investigating the Impact of X-Ray Computed Tomography Imaging on Soluble Organic Matter in the Murchison Meteorite: Implications for Bennu Sample Analyses

X-ray computed tomography (XCT) is a valuable reconnaissance tool for three-dimensional imaging and identification of distinct lithologies in extraterrestrial samples. It will be used as part of the preliminary examination of samples returned from asteroid (101955) Bennu by the Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer (OSIRIS-REx) mission. However, it must first be established whether x-rays generated during XCT could degrade or alter the organic composition of the returned samples by radiolysis. To test this, we split a crushed sample of the Murchison CM2 meteorite, kept one portion as a control, and irradiated the other portion up to the maximum x-ray dosage (~180 Gy) that a Bennu sample would experience during an XCT imaging experiment. We then extracted organic compounds from both splits and conducted (i) nontargeted soluble organic analyses to compare the chemical distributions of C-, H-, O-, N-, and S-bearing species and (ii) targeted measurements to quantify the abundances of 96 individual soluble organic molecules that included protein amino acids, amines, carboxylic acids, hydroxy acids, carbonyl compounds, polycyclic aromatic hydrocarbons, alcohols, sugars, and N-heterocycles. We found that XCT imaging of the Murchison meteorite had no measurable impact on the relative abundances or enantiomeric compositions of most of the soluble organic compounds targeted in this study. Elevated total abundances of several soluble organic compound classes were observed in the XCT-scanned Murchison sample relative to the control. This is likely related to particle size heterogeneity and specific surface area differences between the sample aliquots used for the extractions, rather than a result of the x-ray exposure. Assuming the samples returned from asteroid Bennu by OSIRIS-REx have a similar composition to carbonaceous chondrites, these data provide confidence that XCT will not significantly alter their soluble organic compositions.

Daniel P Glavin↗

Identification of Presolar Grains in Quick Look Samples of Asteroid Bennu Returned By the OSIRIS-REx Mission

The OSIRIS-REx spacecraft returned regolith sample from the B-type asteroid Bennu on September 24, 2023. The first samples to be analyzed, termed the Quick Look samples, are comprised of material collected from the avionics deck of the OSIRIS-REx sample canister. Initial mineralogical analysis of the Quick Look sample revealed a diversity of components, including hydrated and anhydrous silicates, sulfides, magnetite, phosphates, and abundant organic matter. Each constituent has their own origin and history, and their study can inform us of the history of Bennu and its parent asteroid. The analysis plan for asteroid Bennu samples is guided by hypotheses that address specific periods of Bennu’s history, from the pre-accretionary epoch to the OSIRIS-REx epoch. The pre-accretionary epoch studies aim to characterize materials that predate the formation of the solar system. One hypothesis that falls under this epoch is that Bennu contains presolar materials derived from diverse sources. These presolar materials include stardust grains that condensed from the outflows of evolved stars or the ejecta of novae and supernovae (SN), as well as organic matter that formed in the interstellar medium. Here we report the identification of C-rich presolar stardust grains in the Bennu Quick Look sample. Isotopically anomalous organic matter in this sample is reported in.

A N Nguyen↗

Summary of Apollo Next Generation Sample Analysis (ANGSA) and Insights for Artemis Preliminary Examination Activities

Analyses of Apollo samples have provided fundamental insights into the origin and history of the Earth-Moon system and the solar system broadly. With great foresight, a subset of samples from Apollo were left unprocessed so that they could be studied by future generations with their modern technology. To prepare for the return of samples from the Moon by the Artemis Program, NASA initiated the Apollo Next Generation Sample Analysis Program (ANGSA) to analyze a subset of the previously unprocessed Apollo samples. The ANGSA consortium consisted of 9 original teams funded by NASA that combined into a single science team referred to as the ANGSA Science Team. ANGSA was designed to function like the sample analysis phase of a sample return mission with a goal to investigate the lower portion of a double drive tube previously sealed on the lunar surface (73001), the upper portion of that drive tube that had remained unopened (73002), and a variety of Apollo 17 samples that had remained stored at -20 ºC for approximately 50 years.

Francis M. McCubbin↗

Trace Oxygen Measurements of Asteroid Sample Storage Desiccators

The Astromaterials Curation facility at the NASA Johnson Space Center is currently curating more than 120 g of carbonaceous asteroid Bennu material as well as over 500 mg of asteroid Ryugu [1 and 2]. These astromaterials are stored in isolating desiccators and gloveboxes under a continuous purge of pure (<1 ppm O 2 ) gaseous nitrogen. The oxygen and moisture concentrations in our OSIRIS-REx sample processing gloveboxes are continuously monitored via integrated sensors; however, our sample storage desiccators lack integrated oxygen and humidity sensors. In previous studies, we used PreSens Fibox 4 trace oxygen meters and optochemical PSt9 spot sensors to measure the oxygen concentrations in candidate asteroid sample containers that had been sealed in nitrogen; we determined that Eagle stainless steel containers inhibit the ingress of external oxygen for several weeks [3]. This optochemical sensor technology allowed us to take precise, contactless measurements within a trace range of 0 to 200 ppmv O 2 . The effectiveness of the trace oxygen sensors in our container experiments inspired us to utilize them to assess the performance of our desiccators that previously lacked trace oxygen monitoring. In this study, our goal was to determine the quality of the nitrogen purge in the isolating desiccator under normal operating conditions by measuring the trace oxygen content. Utilizing optochemical sensor technology, we determined how long the oxygen concentration takes to reach an equilibrium in the desiccator; that is, determine the rate at which the oxygen diffusion into the desiccator equals the rate at which oxygen diffuses out of the desiccator via N2 purge. Additionally, we wanted to determine the oxygen concentration at this equilibrium, the state in which our desiccators are in during normal operating conditions. We tested a custom three chamber desiccator manufactured by Germfree using a PSt9 trace oxygen sensor spot that was mounted into a ¼” National Pipe Tapered (NPT) metal flow-through cell and attached it to the desiccator exhaust. The desiccator consists of top, middle, and bottom isolating chambers. The top chamber door was opened for several minutes to simulate a sample exchange, it was sealed, and then purged ~15 Standard Cubic Feet per Hour (SCFH). Oxygen measurements were automatically recorded via the Fibox 4 trace oxygen meter in 5-minute intervals over the course of a 24-hour period. Our results indicate the desiccator reached an equilibrium value of 10-15 ppm O 2 after ~5 hours (Fig. 1). This data allows us to explore standards for purging and exchange protocols that can be applied to similar types of desiccators in Hayabusa2, OSIRIS-REx, and for sample return collections. The assessment of the internal gaseous compositions of desiccators also allows us to share with the community the N 2 environment in which many of our asteroid samples and hardware are securely curated. Future measurements will include other nitrogen flow rates and measuring the trace oxygen concentration as a function of time for the levels of the previous commercial desiccator in which the Hayabusa2 sample collection was stored. We will also analyze how long the desiccators hold N2 after being disconnected from their N2 source, an extended measurement for sample security reassurance.

Curation↗

Sample mount for electron backscatter diffraction

A sample mount having a bottom surface, a front surface, and a second portion is disclosed. The first portion is perpendicular to the bottom surface. The second portion has an external surface and an internal surface and extends from the first portion to form a 70-degree angle relative to the bottom surface. The sample mount may also have a top surface, an opening extending through the second portion of the front surface, and a receiving area configured to receive a sample, wherein the top surface presents an unimpeded path between the sample and an SEM pole piece. The sample mount may include a spring-loaded handle configured to push the sample against the internal surface of the second portion of the front surface, wherein pushing the sample against the internal surface places the sample at the 70-degree angle relative to the bottom surface.

Wieliczka, David M.↗

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

Compression–tension cell with sample manipulator for in situ X‐ray nanotomography experiments

In situ X-ray nanotomography experiments where tensile or compressive force is applied on the sample require specialized equipment. A compression-tension device with fluid flow-through capability has been designed for X-ray nanotomography beamlines. The compression-tension cell is equipped with a triaxial stage for sample alignment and a high sensitivity loadcell for measurement of applied force. To handle the <100 µm samples used for X-ray nanotomography imaging and for loading samples on the compression-tension cell a sample manipulator has been built. The sample manipulator is capable of selecting a single <100 µm particle for nanotomography scanning while viewing multiple samples under an optical microscope. To test the functionality of these two devices an initial compression experiment involving two glass beads was performed. To demonstrate instrument stability two spherical glass beads were compressed from a no load condition until one of the beads fractured. Nanotomography data were collected at each step of increasing compressive force. The experimentally observed contact area of the spherical glass beads was compared with the theoretical estimate using the Hertz analysis. To demonstrate the fluid flow capability, two calcite grains were compressed against each other under a calcite saturated solution. Surface topological changes were observed for the stressed grain contact area.

X-ray tomography↗

Post-fire time series of sensor and geochemistry sample data from surface water, groundwater, precipitation, soil, and vegetation across Oak Creek watershed, Washington

This dataset supports a broader study examining wildfire impacts on hydrologic connectivity across 5 sites within the Oak Creek watershed and the resulting biogeochemical impacts. Stream sites were selected using the Advanced Terrestrial Simulator (ATS) hydrologic model to identify locations with varying groundwater contributions and hydrologic responses across different burn severity scenarios. The Retreat Fire burned from July 23 to August 2 in 2024, affecting the five study sites at varying burn severities. Each site is equipped with YSI EXO2 sondes logging sub-hourly throughout the year, and grab samples are collected approximately every six weeks. YSI sondes are used to measure temporally resolved proxies for groundwater inputs (specific conductivity) and organic matter (fluorescent dissolved organic matter; fDOM) along with basic water quality and depth. Grab samples of surface water, groundwater, and precipitation are analyzed for water stable isotopes and conductivity to understand endmembers for hydrologic mixing Grab samples of surface water, groundwater, soil water, and litter/vegetation/soil leachates are analyzed for organic matter composition measured by Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry (FTICR-MS) to understand organic matter dynamics. Game camera photos are provided in a separate data package available at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/3018598. Future versions of this dataset will include time series data from YSI EXO2 sondes (fDOM, dissolved oxygen, temperature, depth, specific conductance, turbidity, pH), BaroTROLL sensors (air temperature and barometric pressure), rain gauges (precipitation), and data from the soil and vegetation samples. Because this study is ongoing, this data package will be updated regularly to include newly collected data and the additional data types. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset is comprised of (1) a folder of field photos; (2) a folder of surface water sample data; (3) a folder of raw Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) data; (4) a data checks report; (5) file-level metadata; (6) data dictionary; (7) field metadata; (8) readme; (9) international generic sample number (IGSN) mapping file; and (10) field protocols. The sample data subfolder contains (1) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data and averages; (2) total dissolved nitrogen data and averages; (3) stable water isotopes and averages; (4) methods codes; (5) FTICR-MS methods; and (15) a subfolder of 9.4 Tesla (9.4T) FTICR-MS data. This folder contains the processed data and three subfolders, one containing the .xml files, one containing the water CoreMS output files, and the other containing instructions and scripts for processing the files in CoreMS (https://github.com/EMSL-Computing/CoreMS). All files are .csv, .pdf, .R, .xml, .d, .html, .Rmd, .py, .cal, .json, .jpg, .jpeg, .png, .mov, or .mp4.

Biogeochemistry↗

Quantitative Modeling of High-Energy Electron Scattering in Thick Samples Using Monte Carlo Techniques

Cryo-electron microscopy (cryo-EM) is a powerful tool for imaging biological samples but is typically limited by sample thickness, which is restricted to a few hundred nanometers depending on the electron energy. However, there is a growing need for imaging techniques capable of studying biological samples up to 10 µm in thickness while maintaining nanoscale resolution. This need motivates the use of mega-electron-volt scanning transmission electron microscopy (MeV-STEM), which leverages the high penetration power of MeV electrons to generate high-resolution images of thicker samples. In this study, we employ Monte Carlo simulations to model electron–sample interactions and explore the signal decay of imaging electrons through thick specimens. By incorporating material properties, interaction cross-sections for energy loss, and experimental parameters, we investigate the relationship between the incident and transmitted beam intensities. Key factors such as detector collection angle, convergence semi-angle, and the material properties of samples were analyzed. Our results demonstrate that the relationship between incident and transmitted beam intensities follows the Beer–Lambert law over thicknesses ranging from a few microns to several tens of microns, depending on material composition, electron energy, and collection angles. The linear depth of silicon dioxide reaches 3.9 µm at 3 MeV, about 6 times higher than that at 300 keV. Meanwhile, the linear depth of amorphous ice reaches 17.9 µm at 3 MeV, approximately 11.5 times higher than that at 300 keV. These findings are crucial for advancing the study of thick biological and semiconductor samples using MeV-STEM.

36 MATERIALS SCIENCE↗

Mars Sample Return – An Overview of the Capture, Containment and Return System

The Mars Sample Return campaign aims at bringing back soil, rock and atmospheric samples from Mars to Earth to answer key questions about Mars’ biological evolution by means of four missions. The first one, Mars 2020, landed on the red planet on February 18, 2021 and has to date collected a number of samples through the Perseverance rover. The three subsequent missions will recover the sample tubes, launch them into Mars orbit and transport them back to Earth. These missions are currently in the planning and design stages of development and represent an international effort comprising NASA, ESA and many industry partners. The work presented here provides an overview of the current design and concept of operations of the NASA-provided Capture, Containment, and Return System (CCRS), which is the payload of the ESA-provided Earth Return Orbiter (ERO). ERO will rendezvous with the orbiting samples and CCRS will capture them, contain them and robotically insert them into a capsule that will return the samples to Earth, the Earth Entry System (EES). Three days before arrival on Earth, CCRS will release the EES, which will fly through space, enter Earth’s atmosphere, descend on a well-defined trajectory and safely land at the Utah Test and Training Range. The decision to implement Mars Sample Return will not be finalized until NASA’s completion of the National Environmental Policy Act process. This document is being made available for information purposes only.

Mars Sample Return↗

Stand Alone Electrical Equipment PRL 227a (Formerly PRL 227 LOC3) Confirmatory Sampling Report Addendum

HydroGeoLogic, Inc. (HGL) prepared this Confirmatory Sampling Report Addendum (CSRA) for the National Aeronautics and Space Administration (NASA), Kennedy Space Center (KSC), Florida. PRL 227a Location of Concern (LOC) 3 is located on 10th Street, west of the former Vertical Processing Facility (M7-1469), SWMU 077. The Load Break Switches (LBS) were installed in 1986 and are suspected to have formerly contained dielectric fluid that contained polychlorinated biphenyls (PCBs). The LBS were replaced in 1993 with new LBSs that do not contain PCBs. The LBS are located on a concrete pad surrounded by grass that is mowed and maintained. A total of 330 soil samples were collected between June 2020 and December 2022 from 88 locations at depths ranging from 0-0.5 to 19-20 ft bls. In general, soil samples collected from depths less than 5 ft were collected via hand auger and samples collected beyond 5 ft bls were collected using a direct-push technology drill rig. Soil samples collected from greater than 5 ft bls to 20 ft bls were collected to confirm PCBs were not present at depth in the aquifer matrix. Delineation samples were collected using an approximately 20 ft horizontal spacing. PCB impacted soil has been completely delineated to the State of Florida residential soil cleanup target level (SCTL) at PRL 227a horizontally and vertically. PCB concentrations have been identified above the residential and industrial SCTL as well as concentrations greater than or equal to 50 ppm requiring coordination with EPA and disposal at a facility authorized under TSCA. Based upon the CSRA sampling, an interim measure is recommended to remove PCB impacted soil above the residential SCTL. The total volume of PCB impacted soil to be removed is 591.6 cubic yards. This includes approximately 9.3 cubic yards of soil with PCB concentrations greater than or equal to 50 ppm. An interim measure work plan is included as an attachment to this report.

electrical equipment↗

The Venus Atmospheric Sample Return (VATMOS-SR) Mission Concept

VATMOS-SR (Venus ATMOSpheric - Sample Return) is a small space- craft mission concept that would return several gas samples from the upper atmosphere of Venus (< 110 km) to Earth for scientific analysis. This could be the first sample return mission for an extraterrestrial atmosphere and potentially the first sample return from an Earth-sized planet. The VATMOS-SR mission concept consists of a SmallSat atmospheric sampling probe (45 deg. sphere/cone geometry, <1 m diameter) that is designed to skim through the Venus upper atmosphere and ac- quire gas samples below the homopause altitude (around ~110 km altitude), where the different atmospheric gases are mixed. The velocity of the spacecraft where sampling would occur is expected to be between ~10.5 km/s and ~13.1 km/s, depending on the trajectory chosen (e.g. trajectory shown in Fig. 1).

direct simulation Monte Carlo↗

The Venus Atmospheric Sample Return (VATMOS-SR) Mission Concept

VATMOS-SR (Venus ATMOSpheric - Sample Return) is a small space- craft mission concept that would return several gas samples from the upper atmosphere of Venus (< 110 km) to Earth for scientific analysis. This could be the first sample return mission for an extraterrestrial atmosphere and potentially the first sample return from an Earth-sized planet. The VATMOS-SR mission concept consists of a SmallSat atmospheric sampling probe (45 deg. sphere/cone geometry, <1 m diameter) that is designed to skim through the Venus upper atmosphere and ac- quire gas samples below the homopause altitude (around ~110 km altitude), where the different atmospheric gases are mixed. The velocity of the spacecraft where sampling would occur is expected to be between ~10.5 km/s and ~13.1 km/s, depending on the trajectory chosen.

direct simulation Monte Carlo↗