Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Ferroelectricity in Si-Doped Hafnia: Probing Challenges in Absence of Screening Charges

The ability to develop ferroelectric materials using binary oxides is critical to enable novel low-power, high-density non-volatile memory and fast switching logic. The discovery of ferroelectricity in hafnia-based thin films, has focused the hopes of the community on this class of materials to overcome the existing problems of perovskite-based integrated ferroelectrics. However, both the control of ferroelectricity in doped-HfO2 and the direct characterization at the nanoscale of ferroelectric phenomena, are increasingly difficult to achieve. The main limitations are imposed by the inherent intertwining of ferroelectric and dielectric properties, the role of strain, interfaces and electric field-mediated phase, and polarization changes. In this work, using Si-doped HfO2 as a material system, we performed a correlative study with four scanning probe techniques for the local sensing of intrinsic ferroelectricity on the oxide surface. Putting each technique in perspective, we demonstrated that different origins of spatially resolved contrast can be obtained, thus highlighting possible crosstalk not originated by a genuine ferroelectric response. By leveraging the strength of each method, we showed how intrinsic processes in ultrathin dielectrics, i.e., electronic leakage, existence and generation of energy states, charge trapping (de-trapping) phenomena, and electrochemical effects, can influence the sensed response. We then proceeded to initiate hysteresis loops by means of tip-induced spectroscopic cycling (i.e., “wake-up”), thus observing the onset of oxide degradation processes associated with this step. Finally, direct piezoelectric effects were studied using the high pressure resulting from the probe’s confinement, noticing the absence of a net time-invariant piezo-generated charge. Our results are critical in providing a general framework of interpretation for multiple nanoscale processes impacting ferroelectricity in doped-hafnia and strategies for sensing it.

36 MATERIALS SCIENCE↗

Microscopic Characterization of Carbonaceous Aerosol Particle Aging in the Outflow from Mexico City

The physical and chemical transformations of particles aged in the outflow from Mexico City were investigated for the transport event of 22 March 2006. This study was part of the Megacities Initiative: Local and Global Research Observations (MILAGRO) 2006 field campaign. A detailed chemical analysis of individual particles was performed using a combination of complementary spectro-microscopic techniques. These techniques included scanning transmission X-ray microscopy (STXM) coupled with near edge X-ray absorption fine structure spectroscopy (NEXAFS) and computer controlled scanning electron microscopy with an energy dispersive X-ray analyzer (CCSEM/EDX). As the aerosol plume evolves from the city center, the organic mass per particle increases and the fraction of carbon-carbon double bonds (associated with elemental carbon) decreases. Organic functional groups enhanced with age include: carboxylic acids, alkyl groups, and oxygen bonded alkyl groups. At the city center (T0) the most prevalent aerosol type contained inorganic species (composed of sulfur, nitrogen, oxygen, and potassium) coated with organic material. At the T1 and T2 sites, located northeast of T0 (~29 km and ~65 km, respectively), the fraction of homogenously mixed organic particles increased in both size and number. These observations illustrate the evolution of the physical mixing state and organic bonding in individual particles in a photochemically active environment.

54 ENVIRONMENTAL SCIENCES↗

Microscopic Characterization of Carbonaceous Aerosol Particle Aging in the Outflow from Mexico City

This study was part of the Megacities Initiative: Local and Global Research Observations (MILAGRO) field campaign conducted in Mexico City Metropolitan Area during spring 2006. The physical and chemical transformations of particles aged in the outflow from Mexico City were investigated for the transport event of 22 March 2006. A detailed chemical analysis of individual particles was performed using a combination of complementary microscopy and micro-spectroscopy techniques. The applied techniques included scanning transmission X-ray microscopy (STXM) coupled with near edge X-ray absorption fine structure spectroscopy (NEXAFS) and computer controlled scanning electron microscopy with an energy dispersive X-ray analyzer (CCSEM/EDX). As the aerosol plume evolves from the city center, the organic mass per particle increases and the fraction of carbon-carbon double bonds (associated with elemental carbon) decreases. Organic functional groups enhanced with particle age include: carboxylic acids, alkyl groups, and oxygen bonded alkyl groups. At the city center (T0) the most prevalent aerosol type contained inorganic species (composed of sulfur, nitrogen, oxygen, and potassium) coated with organic material. At the T1 and T2 sites, located northeast of T0 (~;;29 km and ~;;65 km, respectively), the fraction of homogenously mixed organic particles increased in both size and number. These observations illustrate the evolution of the physical mixing state and organic bonding in individual particles in a photochemically active environment.

54 ENVIRONMENTAL SCIENCES↗

Quantify Resonance Inspection with Finite Element-Based Modal Analyses

Resonance inspection uses the natural acoustic resonances of a part to identify anomalous parts. Modern instrumentation can measure the many resonant frequencies rapidly and accurately. Sophisticated sorting algorithms trained on sets of good and anomalous parts can rapidly and reliably inspect and sort parts. This paper aims at using finite-element-based modal analysis to put resonance inspection on a more quantitative basis. A production-level automotive steering knuckle is used as the example part for our study. First, the resonance frequency spectra for the knuckle are measured with two different experimental techniques. Next, scanning laser vibrometry is used to determine the mode shape corresponding to each resonance. The material properties including anisotropy are next measured to high accuracy using resonance spectroscopy on cuboids cut from the part. Then, finite element model (FEM) of the knuckle is generated by meshing the actual part geometry obtained with computed tomography (CT). The resonance frequencies and mode shapes are next predicted with a natural frequency extraction analysis after extensive mesh size sensitivity study. The good comparison between the predicted and the experimentally measured resonance spectra indicate that finite-element-based modal analyses have the potential to be a powerful tool in shortening the training process and improving the accuracy of the resonance inspection process for a complex, production level part. The finite element based analysis can also provide a means to computationally test the sensitivity of the frequencies to various possible defects such as porosity or oxide inclusions especially in the high stress regions that the part will experience in service.

99 GENERAL AND MISCELLANEOUS↗

New Photocatalysts for Hydrogen Production; Nuevos Fotocatalizadores para la Producción de Hidrógeno

The use of hydrogen as replacement for fossil fuels, on which we depend today, is a matter of great relevance. The sustainable generation of hydrogen as fuel is relevant from an environmental and economic point of view. In this study we have explored new synthetic routes for developing new photocatalysts to be used in water splitting, for hydrogen production. Different techniques have been used to produce hydrogen, such as electrolysis, even though these processes have been found to be energetically non suitable. In this research various photocatalytic materials were presented as possible alternatives for using in water splitting processes. Characterization of the new synthesized materials has been done by using different experimental techniques including Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM), surface area BET, and X-ray Diffraction (XRD). The efficiency of the synthesized photocatalysts was determined by evaluating the hydrogen evolution by the photocatalytic water splitting reaction.

08 HYDROGEN↗

Examination Of IASCC In 304 Stainless Steel Core Shroud From A Commercial Boiling Water Reactor (BWR)

The 304 stainless steel core shroud and the accompanying weld material from a commercial boiling-water reactor (BWR) experienced an estimated dose of ~3.5 dpa neutron irradiation leading to irradiation-assisted stress corrosion cracking (IASCC). The resulting IASCC crack tips are examined with high-resolution analysis techniques, including scanning electron microscopy (SEM), scanning transmission electron microscopy (STEM), and atom probe tomography (APT), with select examples of directly correlated STEM/APT observations. Analytical observations reveal the crack morphology, composition, microstructure, and any associated corrosion-induced or radiation-induced segregation in the local metal grain boundaries ahead of the propagating SCC cracks. The observed oxide composition and structure were in-line with expectations, consisting of a Cr-rich inner oxide and a Fe-rich outer oxide, with the leading crack tip oxide being Cr-rich. In addition, the leading grain boundary exhibited typical radiation-induced segregation signatures that were largely unperturbed by the accompanying corrosion. Finally, the quantitative capabilities and limitations of STEM and APT in the context of corrosion fronts and grain boundary chemistry from the directly correlated measurements are discussed.

Olszta, Matthew J.↗

Characterization of U(VI)-Bearing Precipitates Produced by Ammonia Gas Injection Technology for Unsaturated Sediments - 16600

The processing of irradiated fuel to extract plutonium for the nuclear arsenal has resulted in a legacy of uranium contamination in the vadose zone (VZ) of the Hanford 200 Area. This contamination is a potential source for groundwater contamination, posing a risk to receptors through water uptake from contaminated wells or discharges to surface water. The injection of reactive gases is an innovative technology being evaluated for reducing the mobility of radionuclide contaminants in the Hanford vadose zone. Ammonia (NH{sub 3}) gas in particular has been used to reduce uranium mobility in laboratory scale studies and is being evaluated for field scale application. The sediment of the Hanford vadose zone is composed of a complex of mineral phases including quartz, feldspar, mica, and calcium carbonates. The silica content in the 200 Area subsurface markedly outweighs the majority of elements, with aluminum following closely. The injection of ammonia gas into the vadose zone is associated with an increase in pH conditions as the gas partitions into the pore water. The resulting alkaline conditions significantly increase the solubility of some aluminum and silicate-containing minerals within the system. As pH decreases to natural conditions, the aluminosilicate minerals will precipitate, potentially coating and sequestering the uranium contaminants. Although previous laboratory scale tests have shown decreased uranium mobility, there are many questions regarding the application of the remediation method to 200 Area vadose zone conditions. In particular, additional testing is required to understand the impact of various environmental factors on the formation of uranium mineral phases with the application of the NH{sub 3} injection method. In order to answer some of the unknowns regarding this remediation technology for the 200 Area vadose zone, an effort was made to characterize the uranium-bearing precipitates being formed with the injection of ammonia gas. Rather than a sediment-water system, a synthetic pore water solution was prepared using the ion concentrations relevant to the 200 Area vadose zone. These solutions were limited to select constituents believed to play a major role in the remediation process. The use of this carefully composed solution allows for the thorough evaluation of the contribution the variable components make to the formation of the solid analyte. The characterization of solid samples was attempted using a host of complementary analytical techniques including scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS) and X-ray diffraction (XRD). Though characterization of the samples is ongoing, the data produced thus far has allowed for the imaging and X-ray spectroscopy of the solid uranium phases produced as well as a tentative identification of cejkaite (Na{sub 4}(UO{sub 2})(CO{sub 3}){sub 3}) as the major uranium mineral phase. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Elucidating the corrosion mechanism of Ni-based superalloys in the presence of uranium-containing chloride molten salt

The United States Department of Energy (DOE) is committed to the advancement of nuclear reactor technology through initiatives such as the Advanced Reactor Development Program (ARDP), in an effort to diversify the United States energy portfolio towards more sustainable energy options. The ARDP includes demonstration by industry partners of molten chloride fast reactors (MCFRs). Construction of MCFRs requires qualified nuclear structural materials. Unfortunately, there are no current materials that are fully qualified by the Nuclear Regulatory Commission for the construction of molten salt reactors, including MCFRs. Adapting current structural material qualifications requires expansion of our current knowledgebase on the property-performance relationships regarding corrosion performance. In this investigation, we assess microstructural changes in a Ni-based superalloy after exposure to a UCl3¬-containing chloride salt eutectic mixture through a correlated multi-modal approach combining several advanced characterization techniques, including scanning electron microscopy/focused ion beam (SEM/FIB) and transmission electron microscopy (TEM). SEM/FIB analysis will illustrate changes in elemental composition, microstructure, and isotopic information acquired from energy x-ray dispersive spectroscopy (EDS), electron backscatter diffraction (EBSD), and secondary ion mass spectroscopy (SIMS), respectively. This information will then aid in identifying localized regions to elucidate the corrosion mechanism with TEM through a combination of electron diffraction, electron energy loss spectroscopy (EELS), and additional EDS. The findings from this investigation will further expand our assessment of the corrosion performance of structural materials in molten salt chloride systems, aiding to developing fully qualified materials for construction of MCFRs.

36 MATERIALS SCIENCE↗

Characterization of the alumina scale formed on a commercial MCrAlYHfSi coating

A commercial NiCoCrAlYHfSi coating deposited on a Ni-base superalloy substrate was characterized before and after high temperature oxidation. The combination of Y, Hf and Si additions are reported to improve coating performance. Advanced characterization techniques including scanning transmission electron microscopy were used to study the segregation behavior of Y and Hf ions to the alumina grain boundaries after 200h at 1050 C and 100 and 200h exposures at 1100 C. After both exposure times, two distinct oxide layers were observed. The outer transient layer included many Y- and Hf-rich oxide particles. The inner layer consisted of columnar -Al2O3 grains normal to the surface of the coating. Segregation of Y and Hf ions was found on the alumina grain boundaries as has been observed in model alloys with similar compositions. Isothermal exposures for up to 200h at 1050 and 1100 C caused a minimal increase in surface roughness. However, 200 one-hour cycles at 1100 C resulted in a more significant increase in surface roughness.

36 MATERIALS SCIENCE↗

Chapter 14: Electron Microscopy on Thin Films for Solar Cells

This chapter overviews the various techniques applied in scanning electron microscopy (SEM) and transmission electron microscopy (TEM), and highlights their possibilities and also limitations. It gives the various imaging and analysis techniques applied on a scanning electron microscope. The chapter shows that imaging is divided into that making use of secondary electrons (SEs) and of backscattered electrons (BSEs), resulting in different contrasts in the images and thus providing information on compositions, microstructures, and surface potentials. Whenever aiming for imaging and analyses at scales of down to the angstroms range, TEM and its related techniques are appropriate tools. In many cases, also SEM techniques provide the access to various material properties of the individual layers, not requiring specimen preparation as time consuming as TEM techniques. Finally, the chapter dedicates to cross-sectional specimen preparation for electron microscopy. The preparation decides indeed on the quality of imaging and analyses.

14 SOLAR ENERGY↗

High-speed massively parallel scanning

A new technique for recording a series of images of a high-speed event (such as, but not limited to: ballistics, explosives, laser induced changes in materials, etc.) is presented. Such technique(s) makes use of a lenslet array to take image picture elements (pixels) and concentrate light from each pixel into a spot that is much smaller than the pixel. This array of spots illuminates a detector region (e.g., film, as one embodiment) which is scanned transverse to the light, creating tracks of exposed regions. Each track is a time history of the light intensity for a single pixel. By appropriately configuring the array of concentrated spots with respect to the scanning direction of the detection material, different tracks fit between pixels and sufficient lengths are possible which can be of interest in several high-speed imaging applications.

47 OTHER INSTRUMENTATION↗

Comparison of organ-at-risk sparing and plan robustness for spot-scanning proton therapy and volumetric modulated arc photon therapy in head-and-neck cancer

Purpose: Proton radiotherapy for head-and-neck cancer (HNC) aims to improve organ-at-risk (OAR) sparing over photon radiotherapy. However, it may be less robust for setup and range uncertainties. The authors investigated OAR sparing and plan robustness for spot-scanning proton planning techniques and compared these with volumetric modulated arc therapy (VMAT) photon plans. Methods: Ten HNC patients were replanned using two arc VMAT (RapidArc) and spot-scanning proton techniques. OARs to be spared included the contra- and ipsilateral parotid and submandibular glands and individual swallowing muscles. Proton plans were made using Multifield Optimization (MFO, using three, five, and seven fields) and Single-field Optimization (SFO, using three fields). OAR sparing was evaluated using mean dose to composite salivary glands (Comp{sub Sal}) and composite swallowing muscles (Comp{sub Swal}). Plan robustness was determined for setup and range uncertainties (±3 mm for setup, ±3% HU) evaluating V95% and V107% for clinical target volumes. Results: Averaged over all patients Comp{sub Sal}/Comp{sub Swal} mean doses were lower for the three-field MFO plans (14.6/16.4 Gy) compared to the three-field SFO plans (20.0/23.7 Gy) and VMAT plans (23.0/25.3 Gy). Using more than three fields resulted in differences in OAR sparing of less than 1.5 Gy between plans. SFO plans were significantly more robust than MFO plans. VMAT plans were the most robust. Conclusions: MFO plans had improved OAR sparing but were less robust than SFO and VMAT plans, while SFO plans were more robust than MFO plans but resulted in less OAR sparing. Robustness of the MFO plans did not increase with more fields.

60 APPLIED LIFE SCIENCES↗

A scanning angle energy-dispersive X-ray diffraction technique for high-pressure structure studies in diamond anvil cells

A scanning angle diffraction technique with an energy-dispersive solid-state detector (SSD) and white synchrotron radiation has been developed for high-pressure structure studies in diamond anvil cells (DACs). This technique is similar to the CAESAR technique [Y. Wang, T. Uchida, R. Von Dreele, M.L. Rivers, N. Nishiyama, K. Funakoshi, A. Nozawa, and H. Kaneko, A new technique for angle-dispersive powder diffraction using an energy-dispersive setup and synchrotron radiation, J. Appl. Cryst. 37 (2004), p. 947] developed for large-volume presses, but extended to DAC applications with high spatial resolution. The main feature of the technique is the well-defined collimation in the beam path to the detector, which improves the signal-to-noise ratio significantly, compared to routine monochromatic angle-dispersive powder diffraction with area detectors. This is particularly useful and essential for low-scattering materials and for amorphous and liquid diffraction/scattering studies using DACs. Data collected from crystalline and amorphous samples in DACs show that a coarse 2{theta} scan (0.1--0.2{sup o} for crystals and 0.5{sup o} for amorphous structure) is sufficient to obtain reasonable diffraction resolution. The scanning angle energy-dispersive X-ray diffraction technique provides angle-dispersive X-ray diffraction (ADXD) data in multiple energies. Such multi-energy ADXD data carry much more information than regular single-energy ADXD, which could provide site-specific atomic structure information for full structure refinement.

43 PARTICLE ACCELERATORS↗

Scanning angle Raman spectroscopy: Investigation of Raman scatter enhancement techniques for chemical analysis

This thesis outlines advancements in Raman scatter enhancement techniques by applying evanescent fields, standing-waves (waveguides) and surface enhancements to increase the generated mean square electric field, which is directly related to the intensity of Raman scattering. These techniques are accomplished by employing scanning angle Raman spectroscopy and surface enhanced Raman spectroscopy. A 1064 nm multichannel Raman spectrometer is discussed for chemical analysis of lignin. Extending dispersive multichannel Raman spectroscopy to 1064 nm reduces the fluorescence interference that can mask the weaker Raman scattering. Overall, these techniques help address the major obstacles in Raman spectroscopy for chemical analysis, which include the inherently weak Raman cross section and susceptibility to fluorescence interference.

36 MATERIALS SCIENCE↗

Calibration, Reconstruction, and Rendering of Cylindrical Millimeter-Wave Image Data

Cylindrical millimeter-wave imaging systems and technology have been under development at the Pacific Northwest National Laboratory for many years. This technology has been commercialized, and systems are currently being deployed widely across the United States and internationally. These systems are effective at screening for concealed items of all types, however, new sensor designs, image reconstruction techniques, and image rendering algorithms, could potentially improve performance. At PNNL, a number of specific techniques have been developed recently to improve cylindrical imaging methods including wideband techniques, combining data from full 360 degree scans, polarimetric imaging techniques, calibration methods, and 3-D data visualization techniques. Many of these techniques exploit the three-dimensionality of the cylindrical imaging technique by optimizing the depth resolution of the system and using this information to enhance detection. Other techniques, such as polarimetric methods, exploit scattering physics of the millimeter-wave interaction with concealed targets on the body. In this paper, calibration, reconstruction, and three-dimensional rendering techniques will be described that optimize the depth information in these images and the display of the images to the operator.

concealed-weapon detection↗

A TECHNIQUE FOR PRIMARY BEAM CALIBRATION OF DRIFT-SCANNING, WIDE-FIELD ANTENNA ELEMENTS

We present a new technique for calibrating the primary beam of a wide-field, drift-scanning antenna element. Drift-scan observing is not compatible with standard beam calibration routines, and the situation is further complicated by difficult-to-parameterize beam shapes and, at low frequencies, the sparsity of accurate source spectra to use as calibrators. We overcome these challenges by building up an interrelated network of source 'crossing points'-locations where the primary beam is sampled by multiple sources. Using the single assumption that a beam has 180 Degree-Sign rotational symmetry, we can achieve significant beam coverage with only a few tens of sources. The resulting network of crossing points allows us to solve for both a beam model and source flux densities referenced to a single calibrator source, circumventing the need for a large sample of well-characterized calibrators. We illustrate the method with actual and simulated observations from the Precision Array for Probing the Epoch of Reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: Using CTDI{sub vol} to account for differences between scanners

Purpose: Monte Carlo radiation transport techniques have made it possible to accurately estimate the radiation dose to radiosensitive organs in patient models from scans performed with modern multidetector row computed tomography (MDCT) scanners. However, there is considerable variation in organ doses across scanners, even when similar acquisition conditions are used. The purpose of this study was to investigate the feasibility of a technique to estimate organ doses that would be scanner independent. This was accomplished by assessing the ability of CTDI{sub vol} measurements to account for differences in MDCT scanners that lead to organ dose differences. Methods: Monte Carlo simulations of 64-slice MDCT scanners from each of the four major manufacturers were performed. An adult female patient model from the GSF family of voxelized phantoms was used in which all ICRP Publication 103 radiosensitive organs were identified. A 120 kVp, full-body helical scan with a pitch of 1 was simulated for each scanner using similar scan protocols across scanners. From each simulated scan, the radiation dose to each organ was obtained on a per mA s basis (mGy/mA s). In addition, CTDI{sub vol} values were obtained from each scanner for the selected scan parameters. Then, to demonstrate the feasibility of generating organ dose estimates from scanner-independent coefficients, the simulated organ dose values resulting from each scanner were normalized by the CTDI{sub vol} value for those acquisition conditions. Results: CTDI{sub vol} values across scanners showed considerable variation as the coefficient of variation (CoV) across scanners was 34.1%. The simulated patient scans also demonstrated considerable differences in organ dose values, which varied by up to a factor of approximately 2 between some of the scanners. The CoV across scanners for the simulated organ doses ranged from 26.7% (for the adrenals) to 37.7% (for the thyroid), with a mean CoV of 31.5% across all organs. However, when organ doses are normalized by CTDI{sub vol} values, the differences across scanners become very small. For the CTDI{sub vol}, normalized dose values the CoVs across scanners for different organs ranged from a minimum of 2.4% (for skin tissue) to a maximum of 8.5% (for the adrenals) with a mean of 5.2%. Conclusions: This work has revealed that there is considerable variation among modern MDCT scanners in both CTDI{sub vol} and organ dose values. Because these variations are similar, CTDI{sub vol} can be used as a normalization factor with excellent results. This demonstrates the feasibility of establishing scanner-independent organ dose estimates by using CTDI{sub vol} to account for the differences between scanners.

61 RADIATION PROTECTION AND DOSIMETRY↗