Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Atomic Magnetometry Using a Metasurface Polarizing Beamsplitter in Silicon-on-Sapphire

Here, we demonstrate atomic magnetometry using a metasurface polarizing beamsplitter fabricated on a silicon-on-sapphire (SOS) platform. The metasurface splits a beam that is near-resonant with the rubidium atoms (795 nm) into orthogonal linear polarizations, enabling the measurement of magnetically sensitive circular birefringence in rubidium vapor through balanced polarimetry. We incorporated the metasurface into an atomic magnetometer based on nonlinear magneto-optical rotation and measured subnanotesla sensitivity, which is limited by low-frequency technical noise and transmission loss through the metasurface. To our knowledge, this work represents the first demonstration of SOS nanophotonics for atom-based sensing and paves the way for highly integrated, miniaturized atomic sensors with enhanced sensitivity and portability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Virtual sensing-enabled digital twin framework for real-time monitoring of nuclear systems leveraging deep neural operators

Abstract Real-time monitoring is a foundation of nuclear digital twin technology, crucial for detecting material degradation and maintaining nuclear system integrity. Traditional physical sensor systems face limitations, particularly in measuring critical parameters in hard-to-reach or harsh environments, often resulting in incomplete data coverage. Machine learning-driven virtual sensors offer a transformative solution by complementing physical sensors in monitoring critical degradation indicators. This paper introduces the use of Deep Operator Networks (DeepONet) to predict key thermal-hydraulic parameters in the hot leg of pressurized water reactor. DeepONet acts as a virtual sensor, mapping operational inputs to spatially distributed system behaviors without requiring frequent retraining. Our results show that DeepONet achieves low mean squared and Relative L2 error, making predictions 1400 times faster than traditional CFD simulations . These characteristics enable DeepONet to function as a real-time virtual sensor, synchronizing with the physical system to track degradation conditions and provide insights within the digital twin framework for nuclear systems.

Hossain, Raisa↗

Wearable and sensitive heart-rate detectors based on PbS quantum dot and multiwalled carbon nanotube blend film

Wearable and sensitive photodetectors (PDs) have been demonstrated based on a blend film of PbS quantum dots (QDs) and QDs modified multiwalled carbon nanotubes (MWCNTs). Owing to the synergetic effect from high light sensitivity of PbS QDs and excellent conductive and mechanical properties of MWCNTs, the blend PDs show high sensitivity and flexibility performance: device responsivity and detectivity reach 583 mA/W and 3.25 × 10{sup 12 }Jones, respectively, and could stand large number (at least 10 000 cycles) and wide angle (up to 80°) bending. Furthermore, the wearable and sensitive PDs have been applied to measure the heart rate in both red and near infrared (NIR) ranges. The presented PDs are expected to work as sensor candidates in integrated electronic skin.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Using quantum dot photoluminescence for load detection

We propose a novel concept for an integrable and flexible sensor capable to visualize mechanical impacts on lightweight structures by quenching the photoluminescence (PL) of CdSe quantum dots. Considering the requirements such as visibility, storage time and high optical contrast of PL quenching with low power consumption, we have investigated a symmetrical and an asymmetrical layer stack consisting of semiconductor organic N,N,N′,N′-Tetrakis(3-methylphenyl)-3,3′-dimethylbenzidine (HMTPD) and CdSe quantum dots with elongated CdS shell. Time-resolved series of PL spectra from layer stacks with applied voltages of different polarity and simultaneous observation of power consumption have shown that a variety of mechanisms such as photo-induced charge separation and charge injection, cause PL quenching. However, mechanisms such as screening of external field as well as Auger-assisted charge ejection is working contrary to that. Investigations regarding the influence of illumination revealed that the positive biased asymmetrical layer stack is the preferred sensor configuration, due to a charge carrier injection at voltages of 10 V without the need of coincident illumination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Intrinsic thermal interfacial resistance measurement in bonded metal–polymer foils

Heat conduction through bonded metal–polymer interfaces often limits the overall heat transfer in electronic packaging, batteries, and heat recovery systems. To design the thermal circuit in such systems, it is essential to measure the thermal interfacial resistance (TIR) across ~1 µm to 100 µm junctions. Previously reported TIR of metal–polymer junctions utilize ASTM E1530-based two-block systems that measure the TIR by applying pressure across the interface through external heating and cooling blocks. Here, we report a novel modification of the ASTM-E1530 technique that employs integrated heaters and sensors to provide an intrinsic TIR measurement of an adhesively bonded metal–polymer junction. We design the measurement technique using finite element simulations to either passively suppress or actively compensate the lateral heat diffusion through the polymer, which can minimize the systematic error to ≲5%. Through proof-of-concept experiments, we report the TIR of metal–polymer interfaces made from DuPont’s Pyralux double-side copper-clad laminates, commonly used in flexible printed circuit boards. Our TIR measurement errors are <10%. We highlight additional sources of errors due to non-idealities in the experiment and discuss possible ways to overcome them. Our measurement technique is also applicable to interfaces that are electrically insulating such as adhesively joined metal–metal junctions and sputter-coated or welded metal–polymer junctions. Altogether, the technique is capable of measuring TIR ≳10 –5 m 2 KW –1 in bonded metal–polymer foils and can be tailored for in situ measurements in flexible electronics, circuit packaging, and other hybrid metal–polymer systems.

47 OTHER INSTRUMENTATION↗

High-resolution velocimetry in energetic tidal currents using a convergent-beam acoustic Doppler profiler

An array of convergent acoustic Doppler velocimeters has been developed and tested for the high resolution measurement of three-dimensional tidal flow velocities in an energetic tidal site. This configuration has been developed to increase spatial resolution of velocity measurements in comparison to conventional acoustic Doppler profilers (ADPs) which characteristically use diverging acoustic beams emanating from a single instrument. This is achieved using converging acoustic beams with a sample volume at the focal point of 0.03 m 3 . The array is also able to simultaneously measure three-dimensional velocity components in a profile throughout the water column, and as such is referred to herein as a converging-beam acoustic Doppler profiler (CADP). Mid-depth profiling is achieved through integration of the sensor platform with the operational Alstom 1MW DeepGen-IV Tidal Turbine. This proof-of-concept paper outlines system configuration and comparison to measurements provided by co-installed reference instrumentation. Comparison of CADP to standard ADP velocity measurements reveals a mean difference of 8 mm/s, standard deviation of 18 mm/s, and order-of-magnitude reduction in realizable length-scale. CADP focal point measurements compared to a proximal single-beam reference show peak cross-correlation coefficient of 0.96 over 4.0 s averaging period and a 47% reduction in Doppler noise. The dual functionality of the CADP as a profiling instrument with a high resolution focal point make this configuration a unique and valuable advancement in underwater velocimetry enabling improved turbulence, resource and structural loading quantification and validation of numerical simulations. Alternative modes of operation have been implemented including noise-reducing bi-static sampling. Since waves are simultaneously measured it is expected that derivatives of this system will be a powerful tool in wave-current interaction studies.

47 OTHER INSTRUMENTATION↗

Setups for eliminating static charge of the ATLAS18 strip sensors

Abstract Construction of the new all-silicon Inner Tracker (ITk), developed by the ATLAS collaboration to beable to track charged particles produced at the High-Luminosity LHC, started in 2020 and is expected tocontinue till 2028. The ITk detector will include 18,000 highly segmented and radiation hard n+-in-psilicon strip sensors (ATLAS18), which are being manufactured by Hamamatsu Photonics. Mechanical and electrical characteristics of produced sensors are measured upon their delivery at several institutes participating in a complex Quality Control (QC) program. The QC tests performed on each individual sensor check the overall integrity and quality of the sensor.During the QC testing of ATLAS18 strip sensors, an increased number of sensors thatfailed the electrical tests was observed. In particular, IV measurements indicated an early breakdown,while large areas containing several tens or hundreds of neighbouring strips with low interstrip isolationwere identified by the Full strip tests, and leakage current instabilities were measured in a long-term leakage current stability setup. Moreover, a high surface electrostatic charge reaching a level of several hundreds of volts per inch was measured on a large number of sensors and on the plastic sheets, whichmechanically protect these sensors in their paper envelopes. Accumulated data indicates a clearcorrelation between observed electrical failures and the sensor charge-up.To mitigate the above-described issues, the QC testing sites significantly modified the sensor handlingprocedures and introduced sensor recovery techniques based on irradiation of the sensor surface with UVlight or application of intensive flows of ionized gas. In this presentation, we will describe the setupsimplemented by the QC testing sites to treat silicon strip sensors affected by static charge andevaluate the effectiveness of these setups in terms of improvement of the sensor performance.

Instruments & Instrumentation↗

Advanced Instrumentation for Extreme Environments

The Department of Energy (DOE) Office of Nuclear Energy (NE) is pursuing embedded instrumentation and controls (I&C) technology for next generation nuclear power generation applications. Embedded systems encompass a wide range of configurations and technologies; we define embedding in this instance as the integration of the sensors and the control system design into the component design using a systems engineering process. Embedded I&C systems are often an essential part of developing new capabilities, improving reliability, enhancing performance, and reducing operational costs. The new intrinsically safe, more efficient, and cost effective reactor technologies (Next Generation Nuclear Plant and Small Modular Reactors) require the development and application of new I&C technologies. These new designs raise extreme environmental challenges such as high temperatures (over 700 C) and material compatibility (e.g., molten salts). The desired reliability and functionality requires measurements in these extreme conditions including high radiation environments which were not previously monitored in real time. The DOE/NE Nuclear Energy Enabling Technologies (NEET) program currently has several projects investigating I&C technologies necessary to make these reactor designs realizable. The project described in this paper has the specific goal of investigating embedded I&C with the following objectives: 1.Explore and quantify the potential gains from embedded I&C improved reliability, increased performance, and reduced cost 2.Identify practical control, sensing, and measurement techniques for the extreme environments found in high-temperature reactors 3.Design and fabricate a functional prototype high-temperature cooling pump for molten salts represents target demonstration of improved performance, reliability, and widespread usage There are many engineering challenges in the design of a high-temperature liquid salt cooling pump. The pump and motor are in direct contact with molten fluoride salt at 700 C (1,292 F) as part of a reactor cooling loop. The motor-pump combination during normal operation would be red-hot (Figure 1). This environment challenges every facet of the design including seals, wiring, magnetic materials, and sensors. In this paper, we discuss the challenges of sensor design in extreme environments and specifically the sensor design for a high-temperature fluoride salt coolant pump. This pump will be used as a test-bed for embedded I&C development and validation in extreme environments.

Extreme Environments↗

Fine-Grained Application Energy and Power Measurements on the Frontier Exascale System

The increasing complexity and power/energy demands of heterogeneous exascale systems, such as the Frontier supercomputer, present significant challenges for measuring and optimizing power consumption in applications. Current tools either lack the resolution to capture fine-grained power and energy measurements, fail to validate in-band measurements against out-of-band power sensors, or cannot integrate this information with application performance events in a scalable manner. This paper introduces a novel open-source performance toolkit that integrates extended PAPI components with Score-P plugins to enable in-band, fine-grained power and energy measurements, while also supporting validation using power meter measurements for both CPUs and GPUs. One key contribution is the ability to perform millisecond-level power and energy measurements for AMD MI250X GPUs, mapping them to application performance events within a single trace and measurement system that scales. Our toolkit combines coarse-grained measurements from cray_pm counters with high-resolution metrics from rocm_smi and RAPL, converting GPU instantaneous accumulated energy into power to capture both transient and steady-state power behavior, a capability often missed by out-of-band and monitoring tools. By mapping these metrics to specific application regions, developers can identify energy hotspots, address inefficiencies in GPU kernel execution, and validate in-band measurements against external measurements. We demonstrate the effectiveness of this approach through case studies using benchmarks such as GPU rocblas_sgemm, BLIS c_blas_dgemm, and rocHPL, highlighting the variability of the measurements and the impact of transient power spikes on kernel-level efficiency.

Hernandez Mendoza, Oscar [ORNL] (ORCID:00000002538↗

Photonic crystal nanobeam biosensors based on porous silicon

Photonic crystal (PhC) nanobeams (NB) patterned on porous silicon (PSi) waveguide substrates are demonstrated for the specific, label-free detection of oligonucleotides. These photonic structures combine the large active sensing area intrinsic to PSi sensors with the high-quality (Q) factor and low-mode volume characteristic of compact resonant silicon-on-insulator (SOI) PhC NB devices. The PSi PhC NB can achieve a Q-factor near 9,000 and has an approximately 40-fold increased active sensing area for molecular attachment, compared to traditional SOI PhC NB sensors. The PSi PhC NB exhibits a resonance shift that is more than one order of magnitude larger than that of a similarly designed SOI PhC NB for the detection of small chemical molecules and 16-base peptide nucleic acids. Furthermore the design and fabrication of PSi PhC NB sensors are compatible with CMOS processing, sensor arrays, and integration with lab-on-chip systems.

36 MATERIALS SCIENCE↗

The Effect of Diel Temperature and Light Cycles on the Growth of Nannochloropsis oculata in a Photobioreactor Matrix

A matrix of photobioreactors integrated with metabolic sensors was used to examine the combined impact of light and temperature variations on the growth and physiology of the biofuel candidate microalgal species Nannochloropsis oculata. The experiments were performed with algal cultures maintained at a constant 20 °C versus a °15 C to 25 °C diel temperature cycle, where light intensity also followed a diel cycle with a maximum irradiance of 1920 mmol photons m -2 s -1 . No differences in algal growth (Chlorophyll a) were found between the two environmental regimes; however, the metabolic processes responded differently throughout the day to the change in environmental conditions. The variable temperature treatment resulted in greater damage to photosystem II due to the combined effect of strong light and high temperature. Cellular functions responded differently to conditions before midday as opposed to the afternoon, leading to strong hysteresis in dissolved oxygen concentration, quantum yield of photosystem II and net photosynthesis. Overnight metabolism performed differently, probably as a result of the temperature impact on respiration. Our photobioreactor matrix has produced novel insights into the physiological response of Nannochloropsis oculata to simulated environmental conditions. This information can be used to predict the effectiveness of deploying Nannochloropsis oculata in similar field conditions for commercial biofuel production.

09 BIOMASS FUELS↗

ATRC Neutron Detector Testing Quick Look Report

As part of the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) program, a joint Idaho State University (ISU) / French Alternative Energies and Atomic Energy Commission (CEA) / Idaho National Laboratory (INL) project was initiated in FY-10 to investigate the feasibility of using neutron sensors to provide online measurements of the neutron flux and fission reaction rate in the ATR Critical Facility (ATRC). A second objective was to provide initial neutron spectrum and flux distribution information for physics modeling and code validation using neutron activation based techniques in ATRC as well as ATR during depressurized operations. Detailed activation spectrometry measurements were made in the flux traps and in selected fuel elements, along with standard fission rate distribution measurements at selected core locations. These measurements provide additional calibration data for the real-time sensors of interest as well as provide benchmark neutronics data that will be useful for the ATR Life Extension Program (LEP) Computational Methods and V&V Upgrade project. As part of this effort, techniques developed by Prof. George Imel will be applied by Idaho State University (ISU) for assessing the performance of various flux detectors to develop detailed procedures for initial and follow-on calibrations of these sensors. In addition to comparing data obtained from each type of detector, calculations will be performed to assess the performance of and reduce uncertainties in flux detection sensors and compare data obtained from these sensors with existing integral methods employed at the ATRC. The neutron detectors required for this project were provided to team participants at no cost. Activation detectors (foils and wires) from an existing, well-characterized INL inventory were employed. Furthermore, as part of an on-going ATR NSUF international cooperation, the CEA sent INL three miniature fission chambers (one for detecting fast flux and two for detecting thermal flux) with associated electronics for assessment. In addition, Prof. Imel, ISU, has access to an inventory of Self-Powered Neutron Detectors (SPNDs) with a range of response times as well as Back-to-Back (BTB) fission chambers from prior research he conducted at the Transient REActor Test Facility (TREAT) facility and Neutron RADiography (NRAD) reactors. Finally, SPNDs from the National Atomic Energy Commission of Argentina (CNEA) were provided in connection with the INL effort to upgrade ATR computational methods and V&V protocols that are underway as part of the ATR LEP. Work during fiscal year 2010 (FY10) focussed on design and construction of Experiment Guide Tubes (EGTs) for positioning the flux detectors in the ATRC N-16 locations as well as obtaining ATRC staff concurrence for the detector evaluations. Initial evaluations with CEA researchers were also started in FY10 but were cut short due to reactor reliability issues. Reactor availability issues caused experimental work to be delayed during FY11/12. In FY13, work resumed; and evaluations were completed. The objective of this "Quick Look" report is to summarize experimental activities performed from April 4, 2013 through May 16, 2013.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Framework for Structural Online Health Monitoring of Aging and Degradation of Secondary Systems due to some Aspects of Erosion

This report describes the current state of research related to critical aspects of erosion and selected aspects of degradation of secondary components in nuclear power plants. The report also proposes a framework for online health monitoring of aging and degradation of secondary components. The framework consists of an integrated multi-sensor modality system which can be used to monitor different piping configurations under different degradation conditions. The report analyses the currently known degradation mechanisms and available predictive models. Based on this analysis, the structural health monitoring framework is proposed. The Light Water Reactor Sustainability Program began to evaluate technologies that could be used to perform online monitoring of piping and other secondary system structural components in commercial NPPs. These online monitoring systems have the potential to identify when a more detailed inspection is needed using real-time measurements, rather than at a pre-determined inspection interval. This transition to condition-based, risk informed automated maintenance will contribute to a significant reduction of operations and maintenance costs that account for the majority of nuclear power generation costs. There is unanimous agreement between industry experts and academic researchers that identifying and prioritizing inspection locations in secondary piping systems (for example, in raw water piping or diesel piping) would eliminate many excessive in-service inspections. The proposed structural health monitoring framework takes aim at answering this challenge by combining long-range guided wave technologies with other monitoring techniques, which can significantly increase the inspection length and pinpoint the locations that degraded the most. More widely, the report suggests research efforts aimed at developing, validating, and deploying online corrosion monitoring techniques for complex geometries, which are pervasive in NPPs.

47 OTHER INSTRUMENTATION↗

Science Breakthroughs 2030. Final report

Agriculture is a fundamental societal activity, characterized by many different landscapes, crops, markets, and participants. Food, agricultural, and biofuels products are central to the daily life of all citizens, though most do not recognize the fragility of the environment that brings forth this abundance. As is noted in the 2012 report from the President's Council of Advisors on Science and Technology, Agricultural Preparedness and the United States Agricultural Research Enterprise (PCAST, 2012) the food and agricultural system faces constant challenges in: Managing new pests, pathogens, and invasive plants. Increasing the efficiency of water use. Growing food in a changing climate. Reducing the environmental footprint of agriculture. Managing the production of bioenergy. Producing safe and nutritious food. Assisting with global food security and maintaining abundant yields. Science Breakthroughs 2030 was organized to identify the most compelling research directions in food and agriculture, in particular those empowered by the application of insights and tools from disciplines of science and engineering not typically associated with food and agricultural research. A committee appointed by the Chairman of the National Research Council explored ideas for research directions with input from the scientific community, with the objective of producing a report describing ambitious and achievable scientific pathways to address major problems and create new opportunities in food and agriculture. Following numerous meetings, a jamboree, and town hall, the appointed committee prepared a report that has subsequently become a reference for federal agencies supporting research in the food and agricultural space. It highlights five key areas for research investment with broad application across food and agriculture: integrated systems research; sensor development; data mining and information sciences, genomics; and the microbiome.

09 BIOMASS FUELS↗

A Review: PFAS Adsorption, Sensing, and Remediation with Engineered Nanoporous Materials

Per- and polyfluoroalkyl substances (PFAS) are among the most abundant environmental contaminant species. They are widespread due to uncontrolled industrial and commercial use and have been linked to health risks such as cancer. With rising global concerns about the public health effects of PFAS, there is an incentive to develop strategies for reliable monitoring and effective PFAS removal, particularly in drinking water. Traditional PFAS sensing techniques are inefficient due to long measurement times, high labor input, high costs, and limitations to ex situ analysis. Current commercially available sorbents for PFAS removal generally lack the ability to capture PFAS components rapidly and quantitatively. Furthermore, existing sorbents are notably inefficient in removing the more toxic, smaller PFAS chemical chains. Large-scale applications of these methods tend to be costly and resource-intensive. Pacific Northwest National Laboratory has developed unique strategies for PFAS sensing and removal with capture probe technology that has an affinity for fluorocarbons, including PFAS. For both sensing and removal, the customizable capture probes can target specific PFAS compounds since they used a metal-organic framework (MOF)-based technology that can be fine-tuned and molecularly tailored. This tailoring of the materials enables high PFAS sensitivity, selectivity, and faster uptake. PNNL’s capture probe materials have been developed into a sensing technique based on the interactions of the capture probes with PFAS at the molecular level and further transduced that to a quantifiable electrochemical response. The materials have been integrated into a sensor platform developed by New Jersey Institute of Technology (NJIT). Tunable capture probes with a range of detection sensitivities allow for faster and more sensitive PFAS detection limits as low as what appears to be 0.5 ng/L (compared to the U.S. Environmental Protection Agency health advisory level of 70 ng/L). Customization of the capture probe results in improved sorption capacities (fast kinetics and high capacities) compared to commercial granular activated carbons. This research applied various experimental and modeling tools to improve understanding the molecular level interactions between the sorbents towards PFAS adsorption properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design, Build, and Initial Testing of a Portable Methane Measurement Platform

The quantification of methane concentrations in air is essential for the quantification of methane emissions, which in turn is necessary to determine absolute emissions and the efficacy of emission mitigation strategies. These are essential if countries are to meet climate goals. Large-scale deployment of methane analyzers across millions of emission sites is prohibitively expensive, and lower-cost instrumentation has been recently developed as an alternative. Currently, it is unclear how cheaper instrumentation will affect measurement resolution or accuracy. To test this, the Wireless Autonomous Transportable Methane Emission Reporting System (WATCH 4 ERS) has been developed, comprising four commercially available sensing technologies: metal oxide (MOx,), Non-dispersion Infrared (NDIR), integrated infrared (INIR), and tunable diode laser absorption spectrometer (TDLAS). WATCHERS is the accumulated knowledge of several long-term methane measurement projects at Colorado State University’s Methane Emission Technology Evaluation Center (METEC), and this study describes the integration of these sensors into a single unit and reports initial instrument response to calibration procedures and controlled release experiments. Specifically, this paper aims to describe the development of the WATCH 4 ERS unit, report initial sensor responses, and describe future research goals. Meanwhile, future work will use data gathered by multiple WATCH 4 ERS units to 1. better understand the cost–benefit balance of methane sensors, and 2. identify how decreasing instrumentation costs could increase deployment coverage and therefore inform large-scale methane monitoring strategies. Both calibration and response experiments indicate the INIR has little practical use for measuring methane concentrations less than 500 ppm. The MOx sensor is shown to have a logarithmic response to methane concentration change between background and 600 ppm but it is strongly suggested that passively sampling MOx sensors cannot respond fast enough to report concentrations that change in a sub-minute time frame. The NDIR sensor reported a linear change to methane concentration between background and 600 ppm, although there was a noticeable lag in reporting changing concentration, especially at higher values, and individual peaks could be observed throughout the experiment even when the plumes were released 5 s apart. The TDLAS sensor reported all changes in concentration but remains prohibitively expensive. Our findings suggest that each sensor technology could be optimized by either operational design or deployment location to quantify methane emissions. The WATCH4ERS units will be deployed in real-world environments to investigate the utility of each in the future.

47 OTHER INSTRUMENTATION↗

A Bayesian Prognostic Algorithm for Assessing Remaining Useful Life of Nuclear Power Components

A central issue in life extension for the current fleet of light water nuclear power reactors is the early detection and monitoring of significant materials degradation. To meet this need nondestructive measurement methods that are suitable for on-line, continuous, in-plant monitoring over extended time periods (months to years) are needed. A related issue is then, based on a condition assessment or degradation trend, to have the ability to estimate the remaining useful life based of components, structures and systems based on the available materials degradation information. Such measurement and modeling methods form the basis for a new range of advanced diagnostic and prognostic approaches. Prognostic methods that predict remaining life based on large crack growth, and phenomena that can be described by linear elastic fracture mechanics, have been reported by several researchers. The challenge of predicting remaining life for earlier phases of degradation is largely unsolved. Monitoring for early detection of materials degradation requires novel and enhanced sensors and data integration techniques. A recent review has considered the stages of degradation and sensing methods that can potentially be employed to detect and monitor early degradation for nuclear power plant applications. An experimental assessment of selected diagnostic techniques was also reported recently. However, the estimation of remaining useful life (RUL) determined from nondestructive diagnostic measurements for early degradation is still an unsolved problem. This present paper will discuss the application of Bayesian prognostic algorithms applied to the early degradation- life problem.

Bayesian prognostics↗

Methods and apparatus for mid-infrared sensing

A chip-scale, air-clad semiconductor pedestal waveguide can be used as a mid-infrared (mid-IR) sensor capable of in situ monitoring of organic solvents and other analytes. The sensor uses evanescent coupling from a silicon or germanium waveguide, which is highly transparent in the mid-IR portion of the electromagnetic spectrum, to probe the absorption spectrum of fluid surrounding the waveguide. Launching a mid-IR beam into the waveguide exposed to a particular analyte causes attenuation of the evanescent wave's spectral components due to absorption by carbon, oxygen, hydrogen, and/or nitrogen bonds in the surrounding fluid. Detecting these changes at the waveguide's output provides an indication of the type and concentration of one or more compounds in the surrounding fluid. If desired, the sensor may be integrated onto a silicon substrate with a mid-IR light source and a mid-IR detector to form a chip-based spectrometer.

54 ENVIRONMENTAL SCIENCES↗