Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor data validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Field Validation of a Smart Energy Recovery Ventilation System Using Low-Cost Indoor Air Quality Sensors

This project is a field validation, using low-cost indoor air quality (IAQ) sensors, of a smart ventilation system that can help low-load homes in humid environments maintain acceptable indoor humidity conditions while providing adequate ventilation according to ASHRAE 62.2. The objectives of this research were to (1) address builders’ concerns with mechanical ventilation in humid environments and (2) answer the question of whether smart control logic helps with occupant comfort and the creation of a more acceptable indoor environment. To address the objectives of the study, the Southface team collected field data for one year in four Charleston, South Carolina, new construction homes in order to determine the differences in occupant comfort; comfort metrics; IAQ; and heating, ventilating, and air-conditioning (HVAC) energy consumption when toggling biweekly between an energy recovery ventilator (ERV) operating continuously and an ERV operating with smart, time-varying humidity control logic. The smart ventilation algorithm under consideration in this field test did create a less humid indoor environment on an annual basis as quantitatively measured through temperature and relative humidity (T/RH) readings, expressed most discernably as “percentage of time above 60% RH” and “percentage of time above 55°F dewpoint.” However, the difference it made was inconsistent during the spring, summer, and fall months, and it was only directionally consistent during the winter months. We suspect that this is primarily due to the long runtimes and concomitant dehumidification activity of the air-conditioning (A/C) units in response to the high sensible loads in Charleston. The effect of the smart ventilation algorithm was not discernable to the occupants in this study, as recorded through seasonal surveys.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flood Susceptibility Mapping Using Machine Learning and Geospatial-Sentinel-1 SAR Integration for Enhanced Early Warning Systems

This study presents a comprehensive framework for flood susceptibility mapping by integrating geospatial factors with both statistical and machine learning models. Thirteen Flood-related factors, including DEM, slope, TWI, NDVI, etc., are extracted as features of models, and historical flood data derived from Sentinel-1 SAR from 2018 to 2023 are used as the target variables of the models. These datasets are analyzed using a frequency-based statistical model and three machine learning models, including Random Forest, XGBoost, and CNN, to generate flood susceptibility maps. The performance of each model is evaluated through AUC; and SHAP scores are separately generated for Machine learning (ML) models to explain each feature contribution in the ML model. The generated susceptibility maps are validated by high-flood-risk locations monitored by flood sensors, BLE inundation models, and flood-prone areas suggested by the Local Community Task Force. The results indicate that the XGBoost model outperforms all other models, with an AUC of 0.92 and demonstrates the highest alignment with recommended high-flood-risk locations, while the frequency-based statistical model showed the weakest performance with an AUC of 0.65. SHAP value graphs highlight the elevation, slope, and TWI as the most influential features across all models. The susceptibility maps generated by the machine learning model show strong agreement with the BLE map and high-flood-risk areas identified by the local Community Task Force.

Google Engine↗

Identification of High-Frequency Transverse Acoustic Modes in Multi-Nozzle Can Combustors

Abstract High frequency thermoacoustic instabilities are problematic for lean-premixed gas turbines. Identifying which acoustic mode is being excited is important, in that it provides insight into potential mitigation measures and mechanical stress/life. However, the frequency spacing between modes becomes quite close for high frequency instabilities in a can combustor. This makes it difficult to distinguish between the modes (e.g., the first transverse mode vs. a higher order axial/mixed mode) based upon frequency calculations alone, which inevitably have uncertainties in boundary conditions, temperature profiles, and combustion response. This paper presents a methodology to simultaneously identify the acoustic mode shapes in the axial and azimuthal directions from acoustic pressure measurements. Multiple high temperature pressure transducers, located at distinct axial and azimuthal positions, are flush mounted in the combustor wall. The measured pressure oscillations from each sensor are then used to reconstruct the pressure distributions by using a least squares method in conjunction with a solution of a three dimensional wave equation. In order to validate the methodology, finite element method (FEM) calculations with estimated post-flame temperature is used to provide the candidate frequencies and corresponding mode shapes. The results demonstrate the reconstructed mode shapes and standing/spinning character of transverse waves, as well as the associated frequencies, both of which are consistent with the FEM predictions. Nodal line location was also extracted from the experimental data during the instabilities in the pressure data.

Kim, J.↗

Strain gauge for testing microreactor hexagonal core blocks in the Single Primary Heat Extraction and Removal Emulator

To support the development and deployment of microreactor technologies, experiments that help verify and validate reactor systems and components are performed at non-nuclear test facilities. The Single Primary Heat Extraction Removal Emulator at Idaho National Laboratory is one of these test facilities and was used to monitor a test article that has a prototypic geometry of a heat-pipe cooled microreactor core block. To collect crucial temperature and strain data during testing, temperature and strain sensing fiber optics were embedded to the surface of the test article using an ultrasonic additive manufacturing technique. To support and provide benchmark strain data for the embedded sensors, a commercial resistive strain gauge was attached. This report will discuss the results from the deployment of the commercial strain gauge which includes the setup/attachment strategies, data acquisition, and analysis of the strain data.

36 MATERIALS SCIENCE↗

Dry in-pile fracture test (DRIFT) for separate-effects validation of ceramic fuel fracture models

Fracture is an important component of nuclear fuel behavior, and significant efforts have been invested into developing fuel performance models that are capable of accurately representing fracture. Usable data on the process of fracture propagation in nuclear fuel under realistic service conditions are very limited. To address this need, a series of separate-effects experiments were developed and performed at Idaho National Laboratory's Transient Reactor Test (TREAT) facility. These experiments employ a heat sink to radially remove heat from the fuel in a manner that approximates the effect of coolant in an operating light-water reactor (LWR). The test holder for these experiments is known as the Dry In-pile Fracture Test (DRIFT). A series of experiments employing DRIFT and TREAT were performed to provide data on the extent and nature of fracture in fresh fuel at various points during a ramp to full power. Novel aspects of these experiments include the way they employ a heat sink to replicate steady-state LWR conditions, as well as the use of fiber optic sensors for in-reactor thermal instrumentation. Details on the development of this experiment, experimental conditions, and resulting data (including in situ thermal measurements and post-irradiation imaging of fracture) are provided in this work. LWR-equivalent powers ranging from 10 to 25 kW/m were tested using this apparatus. Cracking was visible at all power levels, with increasing cracking extent as the power level increased, although there was little difference in the cracking between the two highest-power tests, which had LWR-equivalent powers of 20 and 25 kW/m.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling and Validation of Performance Limitations for the Optimal Design of Interferometric and Intensity-Modulated Fiber Optic Displacement Sensors

Optical fiber sensors offer advantages over traditional electromechanical sensors, making them particularly well-suited for certain measurement applications. Generally speaking, optical fiber sensors respond to a desired measurand through modulation of an optical signal's intensity, phase, or wavelength. Practically, non-contacting fiber optic displacement sensors are limited to intensity-modulated and interferometric (or phase-modulated) methodologies. Intensity-modulated fiber optic displacement sensors relate target displacement to a power measurement. The simplest intensity-modulated sensor architectures are not robust to environmental and hardware fluctuations, since such variability may cause changes in the measured power level that falsely indicate target displacement. Differential intensity-modulated sensors have been implemented, offering robustness to such intensity fluctuations, and the speed of these sensors is limited only by the combined speed of the photodetection hardware and the data acquisition system (kHz-MHz). The primary disadvantages of intensity-modulated sensing are the relatively low accuracy (?m-mm for low-power sensors) and the lack of robustness, which consequently must be designed, often with great difficulty, into the sensor's architecture. White light interferometric displacement sensors, on the other hand, offer increased accuracy and robustness. Unlike their monochromatic-interferometer counterparts, white light interferometric sensors offer absolute, unambiguous displacement measurements over large displacement ranges (cm for low-power, 5 mW, sources), necessitating no initial calibration, and requiring no environmental or feedback control. The primary disadvantage of white light interferometric displacement sensors is that their utility in dynamic testing scenarios is limited, both by hardware bandwidth and by their inherent high-sensitivity to Doppler-effects. The decision of whether to use either an intensity-modulated interferometric sensor depends on an appropriate performance function (e.g., desired displacement range, accuracy, robustness, etc.). In this dissertation, the performance limitations of a bundled differential intensity-modulated displacement sensor are analyzed, where the bundling configuration has been designed to optimize performance. The performance limitations of a white light Fabry-Perot displacement sensor are also analyzed. Both these sensors are non-contacting, but they have access to different regions of the performance-space. Further, both these sensors have different degrees of sensitivity to experimental uncertainty. Made in conjunction with careful analysis, the decision of which sensor to deploy need not be an uninformed one.

42 ENGINEERING↗

Experimental validation of a high voltage pulse measurement method.

This report describes X-cut lithium niobate s (LiNbO3) utilization for voltage sensing by monitoring the acoustic wave propagation changes through LiNbO3 resulting from applied voltage. Direct current (DC), alternating current (AC) and pulsed voltage signals were applied to the crystal. Voltage induced shift in acoustic wave propagation time scaled quadratically for DC and AC voltages and linearly for pulsed voltages. The measured values ranged from 10 - 273 ps and 189 ps 2 ns for DC and non-DC voltages, respectively. Data suggests LiNbO3 has a frequency sensitive response to voltage. If voltage source error is eliminated through physical modeling from the uncertainty budget, the sensor s U95 estimated combined uncertainty could decrease to ~0.025% for DC, AC, and pulsed voltage measurements.

Cular, Stefan↗

Anomaly Detection in Radiation Sensor Data with Applications to Transportation Security

In this paper, we present a new approach for detecting trucks transporting illicit radioactive materials using radiation data. The approach is motivated by the high number of false alarms that typically results when using radiation portal monitors. Our approach is a three-stage anomaly detection process that consists of transforming the radiation sensor data into wavelet coefficients, representing the transformed data in binary form, and detecting anomalies among data sets using a proximity-based method. The approach is evaluated using simulated radiation data, and the results are encouraging. From a transportation security perspective, our results indicate that the concomitant use of gross count and spectroscopy radiation data improves identification of trucks transporting illicit radioactive materials. The results also suggest that the use of additional heterogeneous data with radiation data may enhance the reliability of the detection process. Further testing with real radiation data and mixture of cargo is needed to fully validate the results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated Assembly Progress Monitoring in Modular Construction Factories Using Computer Vision-Based Instance Segmentation

Modular construction has recently gained interest as a transformative construction method. In this method, a large portion of the construction is performed inside factories, where processes are fast-paced and interdependent; therefore, any deviation from the schedule can delay the production. Such deviations are frequent in modular factories due to the labor-intensive nature of the tasks. This propagation of delays can be mitigated by continuously monitoring each process; however, current manual monitoring methods are laborious, and recently proposed contact sensor-based methods are intrusive to the work. In addition, recent computer vision-based monitoring methods inside factories are limited to detection algorithms that fail to provide the pixel-level accuracy required for assembly progress monitoring in highly occluded factory scenes, and they require a large number of manual annotations. Therefore, this paper proposes a method to monitor the installation of subassemblies in modular construction factories using mask R-CNN instance segmentation and improves the data efficiency of the model using a copy-paste augmentation method. This method was validated on the CCTV videos captured from a modular construction factory in the US, resulting in a 9% mAP improvement in segmentation.

computer vision↗

Uniform and Half‐Space Models for Magnetic Dipole Sources in a Conducting Medium: I. Theory and Results

Underground nuclear events result in electromagnetic signals near the event location. Of particular interest, because its signal can be potentially enhanced by the use of large cavities to decouple the seismic signal, is the generation of an EMP signal within the nuclear detonation (NUDET) cavity, from the formation of a bubble in the local magnetic field. This mechanism is equivalent to a buried time varying magnetic dipole. In order to model such signals Los Alamos National Laboratory is developing a detailed model for the propagation of RF signals from buried sources to nearby sensors, with a focus on sources that are magnetic dipole in character. In order to validate this code, models for simple geometries involving magnetic dipole sources have been implemented. These models represent the fields from vertical and horizontal dipoles in cylindrical coordinates, either in a uniform linear isotropic electrical medium, or in a space consisting of two half spaces interfacing at the plane z=0, with the upper half space having the electrical properties of free space and the lower half space having arbitrary linear conductivity and electrical permittivity. While primarily intended for the validation of the more detailed model, the shorter turnaround time of these models facilitates the study of the general properties of geomagnetic bubble signals. This report summarizes the theory and example results for those models. The use of the model for model validation is illustrated with the near and surface fields for dipoles with Gaussian time dependence. Also examined are the surface fields expected for the geomagnetic bubble predicted by the numerical model of Kovalenko et al for a 1 kt nuclear detonation. The model of Kovalenko et al was also rescaled to allow comparison with Zablocki’s electric field observations for Bilby, Event III, and Event V. While the rescaled Kovalenko et al model had approximately the right time scale for the duration of the main peak, and a slower fall than rise also in qualitative agreement with the observations, the predicted signals had very different polarizations, were too low by more than an order of magnitude, and had less temporal structure. A simple comparison with the vertical B field data of Sweeney, where the detailed event geometries and yields are classified, but the sensor range and bounds on the yields are given, suggest that the scaled Kovalenko et al model gives too small a peak field compared to observations for that data set as well, except perhaps for the Borate event. A companion report will give a detailed discussion of the implementation and code.

58 GEOSCIENCES↗

PRIMED for the Future: Purposing Raw Intake for Machine Learning-Enabled Detection (Final Report)

The COVID-19 pandemic demonstrated how a novel, elusive, and diffuse biological threat can engender uncertainty and misinformation, and it underscored the need for flexible analytical modalities agnostic to the identity of biological material. Yet even before the pandemic, recognition of the limitations of the current, list-based approach, which focuses on known pathogens and biotoxins, and of the importance of agent-agnostic biodetection was growing within the biosecurity community. In a 2018 report on “Biodefense in the Age of Synthetic Biology,” for example, the National Academy of Sciences stated that “an overreliance on the Select Agent List is a systematic weakness affecting many aspects of the United States’ current biodefense mitigation capability”. More recently, a group of biodefense researchers proposed the identification and adoption of “bioagent-agnostic signatures (BASs)” as a way of detecting and characterizing not only existing agents but also novel ones, an approach they believe will “enable a more flexible and resilient biodefense posture”. Indeed, the future of biodetection requires us to begin developing novel analytics that can identify anomalies and/or characteristics that indicate a potential threat, whether known or unknown, without looking for a specific signature that has been identified previously. To assess potential threats more rapidly, it is critical to develop agnostic artificial intelligence (AI)/machine learning (ML) systems that can be employed for real-time assessment of the nature and source of a perturbation. Such systems should be multi scale and multi-dimensional, integrating sensor data from a range of biological, chemical, and physical application spaces. Emerging deep learning (DL) models demonstrate exceptional promise for identification of discriminatory features within multi-dimensional datasets. DL models have the capacity to recognize and encode highly complex patterns in a wide range of input data modalities, including images, text, and biological/chemical/physical spectra. As such, they can execute a wide range of assessments and determinations that have traditionally required a human operator. The promise of advances in DL is apparent in the realm of human health and medicine. DL models have been validated for evaluating a variety of clinical threats to human health in a range of contexts, including infection and cancer, and they demonstrated improved performance in predicting stroke relative to human neurologists in some categories of data. Continuously evolving advances in AI/ML are expected to support more efficient evaluation of raw sequence, spectroscopy, and spectrometry data. For instance, recent advances and deployment of large language models (LLM) such as Generative Pre training Transformer (GPT) and Bidirectional Encoder Representations from Transformers (BERT) have already motivated application of these models for biological function prediction. As frameworks such as LLMs become larger and more complex in their representations, their capacity to serve as pre-trained models that can be fine-tuned for biological/biodetection purposes will similarly be amplified. While existing and emerging AI/ML have found broad applicability and use cases in the clinical sciences, development for environmental evaluation and biodetection has been limited. Functionalizing such capabilities for this purpose requires an understanding of the existing technical landscape and how the respective tools and algorithms are currently being employed. This landscape awareness then allows an assessment of the current practical capabilities of existing models and the anticipated requirements and development efforts that will be needed to adapt available algorithms for biodetection applications relevant to DHS. Leveraging expertise in biodetection, ML, and operational biodetection, the effort described in this report is comprised of a systematic landscape assessment (Subtask 2.1), comparative evaluation (Subtask 2.2), and formulation of a value proposition (Subtask 2.3) for the prospect of ML-enabled, agnostic biodetection from raw, or minimally-processed, datasets.

59 BASIC BIOLOGICAL SCIENCES↗

Development of Optical Fiber-Based Sensors for Nuclear Microreactor Structural Health Monitoring

This report provides an experimental assessment of two different optical fiber–based acoustic sensors that are being investigated for application in nuclear microreactors to enhance structural health monitoring capabilities. Optical fibers are resilient in high-temperature and high-radiation environments, have a small sensor footprint, are immune to electromagnetic interference, and are capable of spatially distributed sensing. The two sensors investigated here are (1) Fabry–Pérot Cavities (FPCs) between two copper-coated fibers, embedded in nickel capillary tubes and (2) type-I fiber Bragg grating (FBG) arrays contained within metal capillary tubes. These sensors can be interrogated using low-coherence interferometry or swept wavelength interferometry, respectively, to measure the resonant frequencies of the components or systems to which these sensors are bonded. The FPC developed herein has been subjected to temperatures up to nearly 800°C while tack-welded to a tubular test specimen. Even at the highest temperatures, the measured resonant frequencies compared well with those obtained using an accelerometer that was bonded to an unheated portion of the specimen. The FBG array was tested in multiple bonding configurations to a tubular test specimen, all at room temperature, with the understanding that high temperature (i.e., type II) FBGs could be used to obtain similar data at high temperatures; the FBG array data were validated with noncontact laser vibrometry, which is being used at Los Alamos National Laboratory to relate acoustic signatures to component stresses and/or structural defects. The goal of this work is to identify the most promising techniques that are also compatible with operation in a microreactor environment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

New frontiers in wind-wildlife monitoring systems

Effective minimization of negative effects of wind energy on wildlife is an iterative process whereby direct observations of wildlife effects inform and validate mitigation strategies. Yet, the full implementation of this adaptive management has been hindered by a lack of appropriate data. The accurate, high-resolution data required exceeds the capacity of most current monitoring approaches (human observers or monitoring technologies applied in isolation). Current applications of monitoring technologies struggle to harness their full potential by failing to capitalize on opportunities for integration with additional technologies and/or by having limited temporal and spatial resolution. At the emergence of this new frontier of wildlife monitoring, we review the elements of a robust wind-wildlife monitoring system and highlight sensor fusion principles that facilitate effective implementation and integration of multiple monitoring technologies. We also illustrate how sensor fusion solutions can generate high resolution data on collision and displacement effects on terrestrial wildlife across complex spatial and temporal scales.

17 WIND ENERGY↗

Neuro-Spark: A Submicrosecond Spiking Neural Networks Architecture for In-Sensor Filtering

Neuro-Spark, which is a new neuromorphic architecture with a field-programmable gate array (FPGA) implementation for ultrafast spiking neural network (SNN) inference at the edge, facilitates smart-pixel in-sensor filtering for high-energy physics experiments at the Large Hadron Collider (LHC). Utilizing the evolutionary optimization for neuromorphic systems (EONS) training method, we generate compact SNN models with 91% signal efficiency, akin to convolutional neural networks but with half the parameters. However, deploying near the detector poses a challenge because the SNN must handle a sustained input data rate exceeding 1013 GB/s. To overcome this, we propose a novel hardware architecture that uses high-level synthesis to construct a tuned architecture for the EONS-trained SNN. In addition to the analysis and validation with an AMD Xilinx Artix-A7 FPGA, our solution consumes only ç24% of FPGA LUT and flipflops. We also introduce an innovative quantization method that reduces FPGA resource utilization by ç15% without compromising accuracy. Our FPGA implementation achieves computing latency of ç10 ns for smart-pixel application inference on an edge FPGA.

Miniskar, Narasinga Rao↗

Real Time Flame Monitoring of Gasifier and Injectors

This project is a multistage effort with the final goal to develop a practical and reliable nonintrusive gasifier injector monitor to assess burner wear and need for replacement. The project team included the National Energy Technology Laboratory (NETL), Gas Technology Institute (GTI), North Carolina State University, and ConocoPhillips. This report presents the results of the sensor development and testing initially at GTI combustion laboratory with natural gas flames, then at the Canada Energy Technology Center (CANMET), Canada in the atmospheric coal combustor as well as in the pilot scale pressurized entrained flow gasifier, and finally the sensor capabilities were demonstrated at the Pratt and Whitney Rocketdyne (PWR) Gasifier and the Wabash River Repowering plant located in West Terre Haute, IN. The initial tests demonstrated that GTI gasifier sensor technology was capable of detecting shape and rich/lean properties of natural gas air/oxygen enriched air flames. The following testing at the Vertical Combustor Research Facility (VCRF) was a logical transition step from the atmospheric natural gas flames to pressurized coal gasification environment. The results of testing with atmospheric coal flames showed that light emitted by excited OH* and CH* radicals in coal/air flames can be detected and quantified. The maximum emission intensities of OH*, CH*, and black body (char combustion) occur at different axial positions along the flame length. Therefore, the excitation rates of CH* and OH* are distinct at different stages of coal combustion and can be utilized to identify and characterize processes which occur during coal combustion such as devolatilization, char heating and burning. To accomplish the goals set for Tasks 4 and 5, GTI utilized the CANMET Pressurized Entrained Flow Gasifier (PEFG). The testing parameters of the PEFG were selected to simulate optimum gasifier operation as well as gasifier conditions normally resulting from improper operation or failed gasifier injectors. The sensor developed under previous tasks was used to assess the spectroscopic characteristics of the gasifier flame. The obtained spectral data were successfully translated into flame temperature measurements. It was also demonstrated that the reduced spectral data could be very well correlated with very important gasification process parameters such as the air/fuel and water/fuel ratio. Any of these parameters (temperature, air/fuel, and water/fuel) is sufficient to assess burner wear; however, the tested sensor was capable of monitoring all three of them plus the flame shape as functions of burner wear. This will likely be a very powerful tool which should enable significant improvements in gasifier efficiency, reliability, and availability. The sensor technology was presented to the project's industrial partner (ConocoPhillips). The partner expressed its strong interest in continuing to participate in the field validation phase of GTI's Flame Monitor Project. Finally the sensor was tested in the PWR (Pratt & Whitney Rocketdyne) gasification plant located at GTI's research campus and at the ConocoPhillips industrial scale gasifier at Wabash River Indiana. The field trials of the GTI Gasifier sensor modified to withstand high temperature and pressure corrosive atmosphere of the industrial entrain flow gasifier. The project team successfully demonstrated the Gasifier Sensor system ability to monitor gasifier interior temperature maintaining unobstructed optical access for in excess of six week without any maintenance. The sensor examination upon completion of the trial revealed that the system did not sustain any damage and required minor cleanup of the optics.

01 COAL, LIGNITE, AND PEAT↗

Authenticated sensor interface device

A system and method for the secure storage and transmission of data is provided. A data aggregate device can be configured to receive secure data from a data source, such as a sensor, and encrypt the secure data using a suitable encryption technique, such as a shared private key technique, a public key encryption technique, a Diffie-Hellman key exchange technique, or other suitable encryption technique. The encrypted secure data can be provided from the data aggregate device to different remote devices over a plurality of segregated or isolated data paths. Each of the isolated data paths can include an optoisolator that is configured to provide one-way transmission of the encrypted secure data from the data aggregate device over the isolated data path. External data can be received through a secure data filter which, by validating the external data, allows for key exchange and other various adjustments from an external source.

97 MATHEMATICS AND COMPUTING↗

Authenticated sensor interface device

A system and method for the secure storage and transmission of data is provided. A data aggregate device can be configured to receive secure data from a data source, such as a sensor, and encrypt the secure data using a suitable encryption technique, such as a shared private key technique, a public key encryption technique, a Diffie-Hellman key exchange technique, or other suitable encryption technique. The encrypted secure data can be provided from the data aggregate device to different remote devices over a plurality of segregated or isolated data paths. Each of the isolated data paths can include an optoisolator that is configured to provide one-way transmission of the encrypted secure data from the data aggregate device over the isolated data path. External data can be received through a secure data filter which, by validating the external data, allows for key exchange and other various adjustments from an external source.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Model Agnostic Bayesian Framework for Online Anomaly/Event Detection in PMU Data

Phasor measurement units (PMU) are integral to the modernization and automation plan of the electric power industry. A PMU data signature contains system-level events (e.g., faults, generation/load change, etc.) and any measurement/device-related errors. Therefore, the reliable and resilient operation of power systems is equivalent to the quality of the PMU data and the situation awareness provided by its data signature. Despite recent progress, current state-of-the-art methods are not fool-proof and have certain limitations tracing an error/abnormality to sensor sub-components and grid systems. This is because of technical challenges imposed by the scarcity of the labeled information, loss of data quality, and non-stationarity of data. In this paper, we consider the online PMU data stream as an output of a stochastic process and pose the anomaly/event detection as a changepoint detection problem dealing with detecting parameter changes in the underlying stochastic processes. The proposed model-agnostic framework relies on: (a) feature extraction utilizing the minimum volume enclosing ellipsoids (MVEE) method from raw PMU observations and (b) a Bayesian framework of changepoint detection. The validity of the proposed methodology is discussed through numerical experiments on real-world utility-scale PMU data.

Hossain, Ramij Raja↗