Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shear strength”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Incorporation of metal ions into polyimides

The effects of the incorporation of metal ions into various polyimides on polyimide properties are investigated. Polyimide films derived from 3,3',4,4'-benzophenone tetracarboxylic acid dianhydride (BDTA) 3,3'-diaminobenzophenone (m,m'-DABP), 4,4'-diaminobenzophenone (p,p'-DABP) or 4,4'-oxydianiline were prepared with the concurrent addition of approximately 20 metals in a variety of forms. In general, it is found that the films derived from BDTA + p,p'-DABP were brittle and of poor quality, with brittle films also produced in most of the BDTA + m, m'-DABP polyimides regardless of whether the added metal was hydrate or anhydrous. Thermomechanical analysis, torsional braid analysis, thermal gravimetric analysis, infrared spectral analysis and isothermal studies on many of the polyimide films produced indicate that the softening temperature is generally increased upon the addition of metal ions, at the expense of thermal stability, while no changes in chemical functionality are observed. The best system studied in regard to polymer property enhancement appears to be tri(acetylacetonato)aluminum(III) added to the m, m'-DABP polyamide, which has been found to exhibit four times the lap shear strength of the polyimide alone.

Taylor, L. T.↗

Completion of evaluation of manufacturing processes for B/Al composites containing 0.2mm diameter boron fibers

Four fabricators produced a total of 54 B/1100 Al, B/6061 Al, and B/2024 Al panels for evaluation. The 8 ply unidirectional, 45 to 50 volume percent, panels were made using 0.20 mm diameter boron fibers which were obtained from a single supplier. Hot press consolidation was carried out in vacuum except for one set of dry woven tape panels which were hot pressed in air. A single testing contractor conducted nondestructive inspection, metallography, fractography and mechanical property tests. The mechanical property tests included 21 and 260 C tensile tests and 21 C shear tests. Panel quality, as measured by nondestructive evaluation, was generally good as were the 21 C tensile properties. The panels hot pressed in air delaminated in the shear tests. Shear strength values were lower in these panels. But tensile strengths were not affected by the delaminations because of the relation between the tensile loading direction and the delaminations. Composite tensile strength was found to be proportional to the volume percent boron and the aluminum matrix rather than to the tape used or fabrication technique. Suitability of these composites for 260 C service was confirmed by tensile tests.

Moore, T. J.↗

Addition polyimide end cap study

The characterization of addition polyimides with various end caps for adhesive applications at 120-250 C environments is discussed. Oligometric polyimides were prepared from 3,3',4,4'-benzophenone tetracarboxylic dianhydride and 3,3'-methylenedianiline which were end-capped with functionally reactive moities which cause crosslinking when the oligomers are heated to 200-400 C. The syntheses of the oligomers are outlined. The thermolysis of the oligomers was studied by differential scanning calorimetry and the resulting polymers were characterized by differential thermal analysis and adhesive performance. The adhesive data include lap shear strengths on titanium 6-4 adherends both before and after aging for 1000 hours at 121 C and/or 232 C.

St.clair, T. L.↗

Experimental determination of the effects of moisture on composite-to-composite adhesive joints

The primary mode of moisture ingress into bonded composite joints is determined using a nuclear probe for deuterium (NPD) to measure the localized D2O content along the length of the adhesive (FM-300 and EA-9601) and through the thickness of bonded composite speciments. Calculated diffusivities and NPD measured equilibrium moisture contents are used to predict the moisture profiles along the length of the adhesives as a function of exposure time, temperature, and relative humidity. These results are compared with the observed moisture profiles to evaluate the extent of enhanced edge diffusion. The FM-300 adhesive exhibits good agreement between measured and predicted profiles at 49 C, 70% and 90% RH, and 77 C, 70% RH. At 77 C, 90% RH, the measured moisture content near the adhesive edge is substantially larger than the predicted level. The EA-9601 adhesive also shows good agreement at 49 C, 70% and 90% RH, but at 77 C, the concentration of D20 near the edges is enhanced at each humidity level. The effect of moisture content on the bond shear strength at room temperature and at elevated temperature is evaluated.

Deiasi, R. J.↗

Room temperature shear properties of the strain isolator pad for the shuttle thermal protection system

Tests were conducted at room temperature to determine the shear properties of the strain isolator pad (SIP) material used in the thermal protection system of the space shuttle. Tests were conducted on both the .23 cm and .41 cm thick SIP material in the virgin state and after fifty fully reversed shear cycles. The shear stress displacement relationships are highly nonlinear, exhibit large hysteresis effects, are dependent on material orientation, and have a large low modulus region near the zero stress level where small changes in stress can result in large displacements. The values at the higher stress levels generally increase with normal and shear force load conditioning. Normal forces applied during the shear tests reduces the low modulus region for the material. Shear test techniques which restrict the normal movement of the material give erroneous stress displacement results. However, small normal forces do not significantly effect the shear modulus for a given shear stress. Poisson's ratio values for the material are within the range of values for many common materials. The values are not constant but vary as a function of the stress level and the previous stress history of the material. Ultimate shear strengths of the .23 cm thick SIP are significantly higher than those obtained for the .41 cm thick SIP.

Sawyer, J. W.↗

Flow properties of a series of experimental thermoplastic polymides

The softening temperature to degradation temperature range of the polymers was about 440 to 650 K. All of the polymers retained small amounts of solvent as indicated by an increase in T(sub g) as the polymers were dried. The flow properties showed that all three polymers had very high apparent viscosities and would require high pressures and/or high temperatures and/or long times to obtain adequate flow in prepregging and molding. Although none was intended for such application, two of the polymers were combined with carbon fibers by solution prepregging. The prepregs were molded into laminates at temperatures and times, the selection of which was guided by the results from the flow measurements. These laminates had room temperature short beam shear strength similar to that of carbon fiber laminates with a thermosetting polyimide matrix. However, the strength had considerable scatter, and given the difficult processing, these polymides probably would not be suitable for continuous fiber composites.

Burks, H. D.↗

Tribological properties of silicon carbide in metal removal process

This paper reviews material properties of adhesion, friction and wear of single-crystal silicon carbide in contact with metals and alloys involved in a metal removal process such as grinding. The tribological properties in the metal removal processes are divided into properties which remove metal by adhesion between sliding surfaces, and metal removal by silicon carbide sliding against a metal, indenting it, and plowing a series of grooves or furrows. The paper also deals with fracture and deformation characteristics of the silicon carbide surface; the adhesion, friction and metal transfer to silicon carbide is related to the relative chemical activity of the metals. Atomic size and content of alloying elements play a dominant role in controlling adhesion and friction properties of alloys. The friction and abrasive wear decrease as the shear strength of the bulk metal increases.

Miyoshi, K.↗

Characterization of aging effects of LARC-160

Specimens of freshly prepared polyimide precursor resin LARC-160 and resin aged at room temperature up to 45 days were characterized by high-pressure liquid chromatography and several different thermal analyses. Graphite reinforced composites were then fabricated from fresh and aged resin and tested to determine if changes observed by these techniques were significant. It was found that resin aging resulted in greater flow during processing and poorer composite isothermal stability. However, aging did not affect the room-temperature flexural or short-beam-shear strengths of the composites.

Young, P. R.↗

Screening of high temperature adhesives for large area bonding

High temperature-resistant adhesive systems were screened for processability, mechanical and physical properties, operational capability at 589 K (600 F), and the ability to produce large area bonds of high quality in fabricating Space Shuttle components. The adhesives consisted primarily of polyimide systems, including FM34B-18, NR-150B2 (DuPont), PMR-15, LARC-13, LARC-160, Thermid 600, and AI-1130L (AMOCA). The processing studies included preparation of polyimide resins, fabrication of film adhesives, development of lay-up and cure procedures, fabrication of honeycomb sandwich panels, and fabrication of mid-plane bonded panels in joints up to 30.5 cm (12 in.) wide. The screening program included tests for tack and drape properties, reticulation and filleting characteristics, ability to produce void-free or low porosity bonds in mid-plane bonded panels, out-time stability, lap shear strength, climbing drum peel strength, and glass transition temperature (Tg). This paper describes the processing methods developed and the test results.

Stenersen, A. A.↗

Effect of storing B-staged graphite/polyimide on fabrication of structural elements

Graphite/polyimide structural elements have been successfully fabricated by forming and curing B-staged Celion 6000/PMR-15 and Celion 6000/LaRC-160 laminates in heated matched metal tooling. The B-staged laminates were subjected to storage for various periods of time up to six months at ambient shop conditions and high humidity prior to fabrication into structural elements to determine the processability of the graphite/polyimide after exposure to these conditions. Changes in processability were monitored by measuring flexure and interlaminar shear strengths, glass transition temperature, moisture content, and formability of the B-staged laminates. No significant change in the processability of either Celion 6000/PMR or Celion 6000/LaRC-160 was recorded indicating that after B-staging the graphite/polyimide laminates can be stored for extended periods of time in normal shop and high humidity environments and then be fabricated into defect-free structural elements in heated platen presses.

Baucom, R. M.↗

Oxidation-Strengthened High-Temperature Rivets

Shear strength of titanium-niobium rivets improves with oxidation. Ti-Nb rivets developed for fastening parts of Space Shuttle thrustors may be suitable also for other high-temperature applications in oxidizing environments--for example, in burner cans of commercial jet engines and boilers and retorts for coal gasification systems.

Mclemore, R. L.↗

Application of In Situ Fiberization for fabrication of improved strain isolation pads and graphite epoxy composites

The feasibility of applying the in situ fiberization process to the fabrication of strain isolation pads (SIP) for the Space Shuttle and to the fabrication of graphite-epoxy composites was evaluated. The ISF process involves the formation of interconnected polymer fiber networks by agitation of dilute polymer solutions under controlled conditions. High temperature polymers suitable for SIP use were fiberized and a successful fiberization of polychloro trifluoroethylene, a relatively high melting polymer, was achieved. Attempts to fiberize polymers with greater thermal stability were unsuccessful, apparently due to characteristics caused by the presence of aromaticity in the backbone of such materials. Graphite-epoxy composites were fabricated by interconnecting two dimensional arrays of graphite fiber with polypropylene IS fibers with subsequent epoxy resin impregnation. Mechanical property tests were performed on laminated panels of this material to evaluate intralaminar and interlaminar shear strength, and thus fracture toughness. Test results were generally unpromising.

Rosser, R. W.↗

Viscoplastic lubrication of asperities

Theoretical analyses for the lubrication of rigid wedge-shaped asperities by a viscoplastic fluid are developed for geometries in which either wedge or squeeze action are dominant. The load support in the wedge action geometry is severly limited by lubricant shear, although the squeeze geometry maintains high load support at small film thicknesses. Results suggest that in cases where macroscopic hydrodynamic lubrication is inadequate, lubricant film breakdown will be promoted by low lubricant shear strength, high sliding speed, low surface roughness, and high surface slope. In addition, results are compared with previous investigations of the factors influencing susceptibility to lubrication failure.

Sheu, S.↗

High temperature composites for advanced missile and space transportation systems

A study has been conducted to characterize a state-of-the-art graphite/polyimide composite system by determining mechanical and thermophysical properties of selected laminates over a temperature range of -250 F to 600 F. The material studied was Celion 3000/PMR-15. Material property data obtained from testing included tension, compression and shear strengths, and coefficient of thermal expansion. Environmental conditions examined were: as cured/post-cured, isothermal aged at 600 F, thermal cycled from -250 F to 600 F, and moisture conditioned. This study has provided an initial data base on a graphite/polyimide composite system capable of operating in 500/600 F applications.

Mccleskey, S. F.↗

Standards for Epoxies Used in Microelectronics

Improved qualification standards and test procedures for epoxy adhesives used in assembly of high-reliability hybrid microcircuits listed in new report. Objective of standards to resolve problems in areas of outgassing, bond shear strength, corrosivity, volume resistivity, ionic impurities, electrical stability, and frequency of qualification testing. pp

Caruso, S. V.↗

Hygrothermomechanical evaluation of transverse filament tape epoxy/polyester fiberglass composites

The static and cyclic load behavior of transverse filament tape (TFT) fiberglass/epoxy and TFY fiberglass/polyester composites, intended for use in the design of low-cost wind turbine blades, are presented. The data behavior is also evaluated with respect to predicted properties based on an integrated hygrothermomechanical response theory. Experimental TFT composite data were developed by the testing of laminates made by using composite layups typical of those used for the fabrication of TFT fiberglass wind turbine blades. Static properties include tension, compression, and interlaminar shear strengths at ambient conditions and at high humidity/elevated temperature conditions after a 500 hour exposure. Cyclic fatigue data were obtained using similar environmental conditions and a range of cyclic stresses. The environmental (temperature and moisture) and cyclic load effects on composite strength degradation are subsequently compared with the predictions obtained by using the composite life/durability theory. The results obtained show that the predicted hygrothermomechanical environmental effects on TFT composites are in good agreement with measured data for various properties including fatigue at different cyclic stresses.

Lark, R. L.↗

A commentary on solid lubricants and wear resistant solids for use in extreme environments

The need for high temperature tribological coatings and self-lubricating materials in advanced technology is discussed. A qualitative model for the mechanism of solid lubrication is proposed. The model is based upon microscopic observations of the dynamics of third-body solids in lubricated contacts. In this model, the rheology of plastic flow is suggested as a more general criterion for predicting the lubricating potential of a solid material than, for example, a specific crystal structure. Some examples of layer-lattice and nonlayer-lattice solids that lubricate by virtue of their extreme plasticity, film coherence, and adhesion to the lubricated metal are described. Circumstantial evidence for the model is presented for low shear-strength solids at room temperature and for solids such as calcium fluoride that become lubricative only when their brittle-to-ductile transition temperature is exceeded. Some materials considerations in the selection of hard-coat materials for wear control are also presented.

Sliney, H. E.↗

Effect of Ionizing Radiation on the Mechanical and Structural Properties of Graphite Fiber Reinforced Composites

Graphite/epoxy (T300/5208) and graphite/polyimide composites (C6000/PMR 15) were exposed to various levels of 0.5 MeV electron radiation with the maximum dose being 10,000 Mrad. A three point bending test was used to evaluate the ultimate stress and modulus of the composites. In all composites except transverse samples of C6000/PMR 15 ultimate stress values remained approximately constant or increased slightly. The modulus values remained approximately constant for all composite types regardless of the radiation level. Interfacial aspects of composites were studied. Interlaminar shear tests were performed on T300/5208 and C6000/PMR 15 composites irradiated to 10,000 Mrad. There was an initial increase in interlaminar shear strength (up to 1,000 Mrad) followed by a sharp decrease with further radiation exposure. Using scanning electron microscopy no visual differences in the mode of fracture could be detected between ruptured control samples and those exposed to various levels of radiation. Electron spectroscopy for chemical analysis (ESCA) revealed little change in the surface elements present in control and highly irradiated T300/5208 composite samples.

Wolf, Kay Woodroof↗