SEARCH · Search NASA
Results for “Sim”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Draft: Development and Validation of Passive Yaw in the Open-Source WEC-Sim Code.
Abstract not provided.
Development and Validation of Passive Yaw in the Open-Source WEC-Sim Code.
Abstract not provided.
Temperature Programmed Desorption Secondary Ion Mass Spectrometer (TPD-SIMS).
Abstract not provided.
DML Resonance & Directional Coupler Sims
Explore the source record for details and available documents.
State of the Art for Integrated Mod Sim
Slides for presentation at INSTAR FY24 annual meeting Slides 6-14 from INL/RPT-23-74073 Slides 16-28 from SAND2021-14105C at https://www.osti.gov/servlets/purl/1898479 Slides 29-35 from INL/RPT-23-73490
NEW DEVELOPMENTS AND CAPABILITIES WITHIN WEC-SIM
Explore the source record for details and available documents.
Review of recent WEC-Sim (v6.1) advanced features
Explore the source record for details and available documents.
Search for direct production of electroweakinos in final states with one lepton, jets and missing transverse momentum in pp collisions at $\sqrt{s} $ = 13 TeV with the ATLAS detector
Searches for electroweak production of wino-like chargino pairs, ${\overset{\sim }{\chi}}_1^{+}{\overset{\sim }{\chi}}_1^{-}$, and of wino-like chargino and next-to-lightest neutralino, ${\overset{\sim }{\chi}}_1^{\pm }{\overset{\sim }{\chi}}_2^0$, are presented. The models explored assume that the charginos decay into a W boson and the lightest neutralino, ${\overset{\sim }{\chi}}_1^{\pm}\to {W}^{\pm }{\overset{\sim }{\chi}}_1^0$. The next-to-lightest neutralinos are degenerate in mass with the chargino and decay to ${\overset{\sim }{\chi}}_1^0$ and either a Z or a Higgs boson, ${\overset{\sim }{\chi}}_2^0\to Z{\overset{\sim }{\chi}}_1^0$ or $h{\overset{\sim }{\chi}}_1^0$. The searches exploit the presence of a single isolated lepton and missing transverse momentum from the W boson decay products and the lightest neutralinos, and the presence of jets from hadronically decaying Z or W bosons or from the Higgs boson decaying into a pair of b-quarks. The searches use 139 fb –1 of $\sqrt{s}$ = 13 TeV proton-proton collisions data collected by the ATLAS detector at the Large Hadron Collider between 2015 and 2018. No deviations from the Standard Model expectations are found, and 95% confidence level exclusion limits are set. Chargino masses ranging from 260 to 520 GeV are excluded for a massless ${\overset{\sim }{\chi}}_1^0$ in chargino pair production models. Degenerate chargino and next-to-lightest neutralino masses ranging from 260 to 420 GeV are excluded for a massless ${\overset{\sim }{\chi}}_1^0$ for ${\overset{\sim }{\chi}}_2^0\to Z{\overset{\sim }{\chi}}_1^0$. For decays through an on-shell Higgs boson and for mass-splitting between ${\overset{\sim }{\chi}}_1^{\pm }/{\overset{\sim }{\chi}}_2^0$ and ${\overset{\sim }{\chi}}_1^0$ as small as the Higgs boson mass, mass limits are improved by up to 40 GeV in the range of 200–260 GeV and 280–470 GeV compared to previous ATLAS constraints.
Secondary Ion Mass Spectral Imaging of Metals and Alloys
Secondary Ion Mass Spectrometry (SIMS) is an outstanding technique for Mass Spectral Imaging (MSI) due to its notable advantages, including high sensitivity, selectivity, and high dynamic range. As a result, SIMS has been employed across many domains of science. In this review, we provide an in-depth overview of the fundamental principles underlying SIMS, followed by an account of the recent development of SIMS instruments. The review encompasses various applications of specific SIMS instruments, notably static SIMS with time-of-flight SIMS (ToF-SIMS) as a widely used platform and dynamic SIMS with Nano SIMS and large geometry SIMS as successful instruments. We particularly focus on SIMS utility in microanalysis and imaging of metals and alloys as materials of interest. Additionally, we discuss the challenges in big SIMS data analysis and give examples of machine leaning (ML) and Artificial Intelligence (AI) for effective MSI data analysis. Finally, we recommend the outlook of SIMS development. It is anticipated that in situ and operando SIMS has the potential to significantly enhance the investigation of metals and alloys by enabling real-time examinations of material surfaces and interfaces during dynamic transformations.
Search for direct pair production of sleptons and charginos decaying to two leptons and neutralinos with mass splittings near the $W$-boson mass in $\sqrt{s}$ = 13 TeV pp collisions with the ATLAS detector
A search for the electroweak production of pairs of charged sleptons or charginos decaying into two-lepton final states with missing transverse momentum is presented. Two simplified models of R-parity-conserving supersymmetry are considered: direct pair-production of sleptons ($\sim\atop{\ell}$$\sim\atop{\ell}$), with each decaying into a charged lepton and a $\sim\atop{\chi}$ $^{0}_{1}$ neutralino, and direct pair-production of the lightest charginos ($\sim\atop{\chi}$ $^{±}_{1}$ $\sim\atop{\chi}$ $^{∓}_{1}$), with each decaying into a W-boson and a $\sim\atop{\chi}$ $^{0}_{1}$. The lightest neutralino ($\sim\atop{\chi}$ $^{0}_{1}$) is assumed to be the lightest supersymmetric particle (LSP). The analyses target the experimentally challenging mass regions where $m$($\sim\atop{\ell}$) - $m$($\sim\atop{\chi}$ $^{0}_{1}$) and ($m$$\sim\atop{\chi}$ $^{±}_{1}$) – )$m$$\sim\atop{\chi}$ $^{0}_{1}$) are close to the W-boson mass (‘moderately compressed’ regions). The search uses 139 fb –1 of $\sqrt{s}$ = 13 TeV proton-proton collisions recorded by the ATLAS detector at the Large Hadron Collider. No significant excesses over the expected background are observed. Exclusion limits on the simplified models under study are reported in the ($\sim\atop{\ell}$, $\sim\atop{\chi}$ $^{0}_{1}$) and ($\sim\atop{\chi}$ $^{±}_{1}$, $\sim\atop{\chi}$ $^{0}_{1}$) mass planes at 95% confidence level (CL). Sleptons with masses up to 150 GeV are excluded at 95% CL for the case of a mass-splitting between sleptons and the LSP of 50 GeV. Chargino masses up to 140 GeV are excluded at 95% CL for the case of a mass-splitting between the chargino and the LSP down to about 100 GeV.
Comparison of δ 13 C analyses of individual foraminifer ( Orbulina universa ) shells by secondary ion mass spectrometry and gas source mass spectrometry
Rationale: The use of secondary ion mass spectrometry (SIMS) to perform micrometer-scale in situ carbon isotope (δ 13 C) analyses of shells of marine microfossils called planktic foraminifers holds promise to explore calcification and ecological processes. The potential of this technique, however, cannot be realized without comparison to traditional whole-shell δ 13 C values measured by gas source mass spectrometry (GSMS). Methods: Paired SIMS and GSMS δ 13 C values measured from final chamber fragments of the same shell of the planktic foraminifer Orbulina universa are compared. The SIMS–GSMS δ 13 C differences (Δ 13 C SIMS-GSMS ) were determined via paired analysis of hydrogen peroxide-cleaned fragments of modern cultured specimens and of fossil specimens from deep-sea sediments that were either untreated, sonicated, and cleaned with hydrogen peroxide or vacuum roasted. After treatment, fragments were analyzed by a CAMECA IMS 1280 SIMS instrument and either a ThermoScientific MAT-253 or a Fisons Optima isotope ratio mass spectrometer (GSMS). Results: Paired analyses of cleaned fragments of cultured specimens (n = 7) yield no SIMS–GSMS δ 13 C difference. However, paired analyses of untreated (n = 18) and cleaned (n = 12) fragments of fossil shells yield average Δ 13 C SIMS-GSMS values of 0.8‰ and 0.6‰ (±0.2‰, 2 SE), respectively, while vacuum roasting of fossil shell fragments (n = 11) removes the SIMS–GSMS δ 13 C difference. Conclusions: The noted Δ 13 C SIMS-GSMS values are most likely due to matrix effects causing sample–standard mismatch for SIMS analyses but may also be a combination of other factors such as SIMS measurement of chemically bound water. The volume of material analyzed via SIMS is ~10 5 times smaller than that analyzed by GSMS; hence, the extent to which these Δ 13 C SIMS-GSMS values represent differences in analyte or instrument factors remains unclear.
Search for electroweak production of supersymmetric particles in final states with two τ -leptons in $\sqrt{s}$ = 13 TeV pp collisions with the ATLAS detector
Three searches for the direct production of τ-sleptons or charginos and neutralinos in final states with at least two hadronically decaying τ-leptons are presented. For chargino and neutralino production, decays via intermediate τ-sleptons or W and h bosons are considered. The analysis uses a dataset of pp collisions corresponding to an integrated luminosity of 139 fb -1 , recorded with the ATLAS detector at the Large Hadron Collider at a centre-of-mass energy of 13 TeV. No significant deviation from the expected Standard Model background is observed and supersymmetric particle mass limits at 95% confidence level are obtained in simplified models. For direct production of $\sim\atop{\chi}$ $^+_1$ $\sim\atop{\chi}$ $^-_1$, chargino masses are excluded up to 970 GeV, while $\sim\atop{\chi}$ $^±_1$ and $\sim\atop{\chi}$ $^0_2$ masses up to 1160 GeV (330 GeV) are excluded for $\sim\atop{\chi}$ $^±_1$ $\sim\atop{\chi}$ $^0_2$ / $\sim\atop{\chi}$ $^+_1$ $\sim\atop{\chi}$ $^-_1$ production with subsequent decays via τ-sleptons (W and h bosons). Masses of τ-sleptons up to 500 GeV are excluded for mass degenerate $\sim\atop{\tau}$ L,R scenarios and up to 425 GeV for $\sim\atop{\tau}$ L-only scenarios. Sensitivity to $\sim\atop{\tau}$ R -only scenarios from the ATLAS experiment is presented here for the first time, with $\sim\atop{\tau}$ R masses excluded up to 350 GeV.
Synergistic effects of simvastatin and bone marrow-derived mesenchymal stem cells on hepatic fibrosis
Highlights: • Antifibrotic effect in combination treatment Sim-MSC is superior to simvastatin alone. • Inhibition of TGF-β/Smad signaling is key protective mechanism against hepatic fibrosis in combination Sim-MSC. • The Sim-MSC combination treatment recovered the impaired liver function. The beneficial effects of simvastatin on fibrosis in various organs have been reported. In addition, bone marrow (BM)-derived mesenchymal stem cells (MSCs) have been suggested as an effective therapy for hepatic fibrosis and cirrhosis. Recent evidence suggests that pharmacological treatment devoted to regulating stem cell function is a potential new therapeutic strategy that is drawing nearer to clinical practice. The aim of this study was to determine whether the combination treatment of simvastatin plus MSCs (Sim-MSCs) could have a synergistic effect on hepatic fibrosis in a thioacetamide (TAA)-induced cirrhotic rat model and hepatic stellate cells (HSCs). Cirrhotic livers from rats treated with Sim-MSCs exhibited histological improvement compared to those treated with simvastatin alone. Sim-MSCs combination treatment decreased hepatic collagen distribution, lowered the hydroxyproline content, and rescued liver function impairment in rats with TAA-induced cirrhosis. These protective effects were more potent with Sim-MSCs than with simvastatin alone. The upregulation of collagen-1, α-smooth muscle actin (α-SMA), transforming growth factor (TGF)-β1, and phospho-Smad3 in cirrhotic livers was prevented by the administration of Sim-MSCs. Intriguingly, Sim-MSCs inhibited both TGF-β/Smad3 signaling and α-SMA in HSCs. The Sim-MSCs combination treatment exerted strong protective effects against hepatic fibrosis by suppressing TGF-β/Smad signaling. Simvastatin could act synergistically with MSCs as an efficient therapeutic approach for intractable cirrhosis.
Data for Selected Ion Monitoring for Orbitrap-Based Metabolomics
Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.f
Secondary ion mass spectrometry: The application in the analysis of atmospheric particulate matter
Currently, considerable attention has been paid to atmospheric particulate matter (PM) investigation due to its importance in human health and global climate change. Surface characterization of PM is important since the chemical heterogeneity between the surface and bulk may vary its impact on the environment and human being. Secondary ion mass spectrometry (SIMS) is a surface technique with high surface sensitivity, capable of high spatial chemical imaging and depth profiling. Recent research shows that SIMS holds great potential in analyzing both surface and bulk chemical information of PM. In this review, we presented the working principal of SIMS in PM characterization, summarized recent applications in PM analysis from different sources, discussed its advantages and limitations, and proposed the future development of this technique with a perspective in environmental sciences.