Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Investigation of the effect of bilayer membrane structures and fluctuation amplitudes on SANS/SAXS profile for short membrane wavelength

The effect of bilayer membrane structures and fluctuation amplitudes on small angle neutron scattering (SANS) and small angle X-ray scattering (SAXS) profile is investigated based on harmonic motions of the surfactant bilayers with bending as well as thickness fluctuation motions. In this study we consider the case in which the wavelength of the bilayer membrane is shorter than the thickness of the membrane. We find that the thickness of the surfactant bilayer membrane, d{sub m}, affects both q{sub dip} and q{sub peak} of I(q,0) profile, and that the fluctuation amplitude, a, of the membrane changes the peak of I(q,0). A simple formula is derived to estimate the thickness of the bilayer based on the q{sub dip} of the profile obtained from the simulation. The resulting estimates of the thickness of the bilayer with harmonic motion showed accuracy within 1%. Moreover, the bilayer thicknesses estimated from the proposed formula show an excellent agreement with the SANS and SAXS experimental results available in the literatures. We also propose a curve fit model, which describes the relationship between the fluctuation amplitude and the normalized q{sub peak} ratio. The present results show the feasibility of the simple formula to estimate the fluctuation amplitude based on the SANS and SAXS profiles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural Evolution of Layered Hybrid Lead Iodide Perovskites in Colloidal Dispersions

Controlling the structure of layered hybrid metal halide perovskites, such as the Ruddlesden-Popper (R-P) phases, is challenging because of their tendency to form mixtures of varying composition. Colloidal growth techniques, such as antisolvent precipitation, forms colloidal dispersions with properties that match bulk layered R-P phases, but controlling the composition of these particles remains challenging. Here, we explore the microstructure of particles of R-P phases of methylammonium lead iodide prepared by antisolvent precipitation from ternary mixtures of alkylammonium cations, where one cation can form perovskite phases (CH 3 NH 3 + ) and the other two promote layered structures as spacers (e.g. C 4 H 9 NH 3 + and C 12 H 25 NH 3 + ). We determine that alkylammonium spacers pack with constant methylene density in the R-P interlayer, and exclude interlayer solvent in dispersed colloids, regardless of length or branching. Using this result, we illustrate how the competition between cations that act as spacers between layers, or as grain- terminating ligands, determines the colloidal microstructure of layered R-P crystallites in solution. Optical measurements reveal that quantum well dimensions can be tuned by engineering the ternary cation composition. Transmission synchrotron wide-angle X-ray scattering and small angle neutron scattering reveal changes in the structure of colloids in solvent and after deposition into thin films. In particular, we find that spacers can alloy between R-P layers if they share common steric arrangements, but tend to segregate into polydisperse R-P phases if they do not mix. In conclusion, this study provides a framework to compare the microstructure of colloidal layered perovskites and suggests clear avenues to control phase and colloidal morphology.

14 SOLAR ENERGY↗

Neutron Dark-Field Tomography

We report how a grating interferometer yields neutron dark-field scatter images for tomographic investigations. The image contrast is based on ultrasmall-angle scattering. It provides otherwise inaccessible spatially resolved information about the distribution of micrometer and submicrometer sized structural formations. Three complementary sets of tomographic data corresponding to attenuation, differential phase, and small-angle scattering can be obtained from one measurement. The method is compatible with conventional imaging and provides significantly higher efficiency than existing techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Decomposition of liquid-liquid extraction organic phase structure into critical and pre-peak contributions

Solution nanostructure induced by amphiphile self-association plays an important role in various chemical and physical processes, including liquid-liquid extraction (LLE). Small angle scattering techniques are an essential means of probing this structure, but, due to non-uniqueness of scattering patterns, their interpretation is not trivial. Here, in this study, we decompose small angle x-ray scattering (SAXS) patterns for a range of binary LLE organic phases into two components: Ornstein-Zernike and pre-peak contributions resulting from, respectively, critical concentration fluctuations and packing of the amphiphilic extractant molecules in the nonpolar aliphatic diluent. While we previously applied Ornstein-Zernike scattering models to similar organic phases, including the pre-peak explicitly in the fit allows us to measure weak fluctuations at high extractant concentration and simultaneously obtain information on the position and intensity of the correlation peak related to amphiphile packing. Scattering patterns and partial structure factors calculated from molecular dynamics simulations support this interpretation. We demonstrate how this minimal scattering model describes nanostructuring for a large number of extractant types over their entire extractant/diluent composition ranges, suggesting simple and universal behavior. The straightforward assignment of these structural contributions facilitates the comparison of these features between different classes of extractant molecules and will enable further studies of organic phase aggregation. Applicability to more complex, process-relevant organic phases is illustrated with post-contact organic phases containing significant quantities of extracted lanthanide nitrate salt, which we find are readily described by this model.

74 ATOMIC AND MOLECULAR PHYSICS↗

Small-angle X-ray scattering, synchrotron radiation, and the structure of bio- and nanosystems

Small-angle X-ray scattering is a universal diffraction method for studying the supra-atomic structure of matter. The potential of this technique has greatly increased in recent years due to the development of bright synchrotron radiation sources. The extensive use of these sources, in combination with new techniques for analyzing scattering data and structure modeling, made small-angle scattering one of the most effective analytical methods for studying nanoscale structures. In this review, after a brief outline of the basic principles of small-angle scattering by isotropic dispersed nanosystems, we consider two areas of nanodiagnostics, in which the progress in the small-angle experiment and the latest techniques for interpreting scattering data has become pronounced in recent years. These areas-the analysis of the structure of biological macromolecules in a solution and structural studies of metal nanoparticles synthesized in polymer and aqueous media-are illustrated by examples of practical biological and nanotechnologycal applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthesis of 1 nm Pd Nanoparticles in a Microfluidic Reactor: Insights from in Situ X ray Absorption Fine Structure Spectroscopy and Small-Angle X ray Scattering

In this paper we show that the temporal separation of nucleation and growth is not a necessary condition for the colloidal synthesis of monodisperse nanoparticles. The synthesis mechanism of Pd nanoparticles was determined by in situ XAFS and SAXS in a microfluidic reactor capable of millisecond up to an hour time resolution. The SAXS results showed two autocatalytic growth phases, a fast growth phase followed by a very slow growth phase. The steady increase in the number of particles throughout the two growth phases indicates the synthesis is limited by slow continuous nucleation. The transition from fast to slow growth was caused by rapid increase in bonding with the capping agent as shown by XAFS. Based on this fundamental understanding of the synthesis mechanism, we show that 1 nm monodisperse Pd nanoparticles can be synthesized at low temperature using a strong binding capping agent such as trioctylphosphine (TOP).

Environmental Molecular Sciences Laboratory↗

Spectral softening in the X-RAY afterglow of GRB 130925A as predicted by the dust scattering model

Gamma-ray bursts (GRBs) usually occur in a dense star-forming region with a massive circumburst medium. The small-angle scattering of intense prompt X-ray emission off the surrounding dust grains will have observable consequences and sometimes can dominate the X-ray afterglow. In most of the previous studies, only the Rayleigh-Gans (RG) approximation is employed for describing the scattering process, which works accurately for the typical size of grains (with radius of a ≤ 0.1 μm) in the diffuse interstellar medium. When the size of the grains may significantly increase, as in a more dense region where GRBs would occur, the RG approximation may not be valid enough for modeling detailed observational data. In order to study the temporal and spectral properties of the scattered X-ray emission more accurately with potentially larger dust grains, we provide a practical approach using the series expansions of anomalous diffraction (AD) approximation based on the complicated Mie theory. We apply our calculations to understand the puzzling X-ray afterglow of recently observed GRB 130925A that showed a significant spectral softening. We find that the X-ray scattering scenarios with either AD or RG approximation adopted could well reproduce both the temporal and spectral profile simultaneously. Given the plateau present in the early X-ray light curve, a typical distribution of smaller grains as in the interstellar medium would be suggested for GRB 130925A.

79 ASTRONOMY AND ASTROPHYSICS↗

The pore wall structure of porous semi-crystalline anatase TiO2

The structure of porous TiO2 prepared by electrochemical anodization in a fluoride-containing ethylene glycol electrolyte solution was quantitatively studied using small angle neutron scattering (SANS) and ultra small angle neutron scattering (USANS). The cylindrical pores along the coaxial direction were somewhat irregular shape, were broadly distributed in diameter, and seemed to have a broadly pseudo-hexagonal arrangement. The scattering from the pore wall showed a negative deviation from Porod scattering, indicating the interface between TiO2 and the pore was not sharp. A density gradient of around 40 ~ 60 at the pore wall (i.e. interface between the pore and the TiO2 matrix) was estimated using both constant and semi-sigmoidal interface models. This may be due to the presence of fluorine and carbon partially absorbed by the pore wall from the fluoride-containing electrolyte and sorbed water molecules on the wall. The neutron contrast-matching point between the TiO2 matrix and the pores filled with liquid H2O/D2O mixtures was 51/49 vol/vol H2O/D2O, yielding an estimated mass density of 3.32 g/cm3. The specific surface area of the sample derived from the (U)SANS data, S/V, was around 939 ~ 1003 m2/cm3 (283~ 302m2/g).

Kim, Dr Man-Ho↗

Periodic magnetic field as a polarized and focusing thermal neutron spectrometer and monochromator

A novel periodic magnetic field (PMF) optic is shown to act as a prism, lens, and polarizer for neutrons and particles with a magnetic dipole moment. The PMF has a two-dimensional field in the axial direction of neutron propagation. The PMF alternating magnetic field polarity provides strong gradients that cause separation of neutrons by wavelength axially and by spin state transversely. The spin-up neutrons exit the PMF with their magnetic spins aligned parallel to the PMF magnetic field, and are deflected upward and line focus at a fixed vertical height, proportional to the PMF period, at a downstream focal distance that increases with neutron energy. The PMF has no attenuation by absorption or scatter, as with material prisms or crystal monochromators. Embodiments of the PMF include neutron spectrometer or monochromator, and applications include neutron small angle scattering, crystallography, residual stress analysis, cross section measurements, and reflectometry. Presented are theory, experimental results, computer simulation, applications of the PMF, and comparison of its performance to Stern-Gerlach gradient devices and compound material and magnetic refractive prisms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure and phase behavior of polymer loaded non-ionic and anionic microemulsions

We investigate the structure and phase behavior of C{sub 12}E{sub 4} based reverse water in octane microemulsions with small angle x-ray scattering and small angle neutron scattering experiments to explore the phase diagram of the droplet structure. In the regime of stable droplets, these droplets are loaded with the hydrophilic polymer polyethyleneoxide (M{sub W} = 1500 g/mol) and compared with microemulsions based on the anionic surfactant AOT. In the small angle neutron scattering experiments, we use shell contrast to focus on the surfactant shell and its variation with addition of polymer. We observe, as predicted by indirect measurements such as dielectric spectroscopy, that the polymer interacts differently with a nonionic or an anionic surfactant shell: In the former case the addition of polymer does not seem to affect the surfactant shell. In the latter case, the obtained scattering data show that the anionic surfactant layer is strongly influenced leading to a higher polydispersity which may be attributed to a floppier surfactant shell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of the Decaheme c-Type Cytochrome OmcA in Solution and on Hematite Surfaces by Small Angle X-Ray Scattering and Neutron Reflectometry

The outer membrane protein OmcA is an 85 kDa decaheme c-type cytochrome located on the surface of the dissimilatory metal-reducing bacterium Shewanella oneidensis MR-1. It is assumed to mediate shuttling of electrons to extracellular acceptors that include solid metal oxides such as hematite (α-Fe 2 O 3 ). No information is yet available concerning OmcA structure in physiologically relevant conditions such as aqueous environments. We purified OmcA and characterized its solution structure by small angle x-ray scattering (SAXS), and its interaction at the hematite-water interface by neutron reflectometry. SAXS showed that OmcA is a monomer that adopts a flat ellipsoidal shape with an overall dimension of 34 × 90 × 65 Å 3 . To our knowledge, we obtained the first direct evidence that OmcA undergoes a redox state-dependent conformational change in solution whereby reduction decreases the overall length of OmcA by ~7 Å (the maximum dimension was 96 Å for oxidized OmcA, and 89 Å for NADH and dithionite-reduced OmcA). OmcA was also found to physically interact with electron shuttle molecules such as flavin mononucleotide, resulting in the formation of high-molecular-weight assemblies. Neutron reflectometry showed that OmcA forms a well-defined monomolecular layer on hematite surfaces, where it assumes an orientation that maximizes its contact area with the mineral surface. Finally, these novel insights into the molecular structure of OmcA in solution, and its interaction with insoluble hematite and small organic ligands, demonstrate the fundamental structural bases underlying OmcA's role in mediating redox processes.

Environmental Molecular Sciences Laboratory↗

Stability of the bituminous coal microstructure upon exposure to high pressures of helium

Small-angle neutron scattering (SANS) and ultra-small-angle neutron scattering (USANS) measurements of the structure of two Australian bituminous coals (particle size of 1-0.5 mm) before, during, and after exposure to 155 bar of helium were made to identify any effects of pressure alone on the pore size distribution of coal and any irreversible effects upon exposure to high pressures of helium in the pore size range from 3 nm to 10 {mu}m. No irreversible effects upon exposure were identified for any pore size. No effects of pressure on pore size distribution were observed, except for a small effect at a pore size of about 2 {mu}m for one coal. This study provides a convenient baseline for SANS and USANS investigations on sorption of gases at elevated pressures on coals, by distinguishing between the effect of pressure alone on coal pore size distribution and against the effect of the gas to be investigated. 35 refs., 5 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

The structure of water in the hydration shell of cations from x-ray Raman and small angle x-ray scattering measurements

X-ray Raman scattering (XRS) spectroscopy and small angle x-ray scattering (SAXS) are used to study water in aqueous solutions of NaCl, MgCl{sub 2}, and AlCl{sub 3} with the particular aim to provide information about the structure of the hydration shells of the cations. The XRS spectra show that Na{sup +} weakens the hydrogen bonds of water molecules in its vicinity, similar to the effect of increased temperature and pressure. Mg{sup 2+} and Al{sup 3+}, on the other hand, cause the formation of short and strong hydrogen bonds between the surrounding water molecules. The SAXS data show that Mg{sup 2+} and Al{sup 3+} form tightly bound hydration shells that give a large density contrast in the scattering data. From the form factors extracted from the SAXS data, we found that Mg{sup 2+} and Al{sup 3+} have, respectively, an equivalent of one and one and a half stable hydration shells that appear as a density contrast. In addition, we estimated that the density of water in the hydration shells of Mg{sup 2+} and Al{sup 3+} is, respectively, {approx}61% and {approx}71% higher than in bulk water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Mo-anode-based in-house source for small-angle X-ray scattering measurements of biological macromolecules

We demonstrate the use of a molybdenum-anode-based in-house small-angle X-ray scattering (SAXS) setup to study biological macromolecules in solution. Our system consists of a microfocus X-ray tube delivering a highly collimated flux of 2.5 × 10{sup 6} photons/s at a beam size of 1.2 × 1.2 mm{sup 2} at the collimation path exit and a maximum beam divergence of 0.16 mrad. The resulting observable scattering vectors q are in the range of 0.38 Å{sup −1} down to 0.009 Å{sup −1} in SAXS configuration and of 0.26 Å{sup −1} up to 5.7 Å{sup −1} in wide-angle X-ray scattering (WAXS) mode. To determine the capabilities of the instrument, we collected SAXS data on weakly scattering biological macromolecules including proteins and a nucleic acid sample with molecular weights varying from ∼12 to 69 kDa and concentrations of 1.5–24 mg/ml. The measured scattering data display a high signal-to-noise ratio up to q-values of ∼0.2 Å{sup −1} allowing for an accurate structural characterization of the samples. Moreover, the in-house source data are of sufficient quality to perform ab initio 3D structure reconstructions that are in excellent agreement with the available crystallographic structures. In addition, measurements for the detergent decyl-maltoside show that the setup can be used to determine the size, shape, and interactions (as characterized by the second virial coefficient) of detergent micelles. This demonstrates that the use of a Mo-anode based in-house source is sufficient to determine basic geometric parameters and 3D shapes of biomolecules and presents a viable alternative to valuable beam time at third generation synchrotron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗