An improved data structure for AVIRIS-type imaging spectrometer measurements

Imaging spectrometers, such as the Airborne Visible/Infrared Imaging (AVIRIS), measure spectra in the region from 400 to 2500 nm at nominally 10-nrn sampling. This gives approximately 200 continuous spectral channels of data for every spatial element measured. These spectroscopic measurements are used to determine the composition and infer processes of the Earth system through spectroscopy analysis. Spectroscopic analysis is based on the physics, chemistry, and biology revealed through the interaction of energy with matter recorded in each measured spectrum

Perez, Rosa M.↗

Imaging system and method for enhanced visualization of near surface vascular structures

A sub-dermal structure visualization system and method is disclosed. The system may use an illumination module including: a near-infrared (NIR) light source adapted to substantially uniformly illuminate an imaged area including sub-dermal regions thereof with NIR light; and a first optical system including at least one optical element for controlling at least one of spectral and polarization properties of the NIR light prior to illuminating the imaged area. An imaging module rejects unwanted signals from an imaged area while passing desired optical signals that are to be received by an image acquisition module. The desired optical signals can comprise a vein visualization signal to assist in visualizing a vascular structure below a skin layer of a patient.

Demos, Stavros G.↗

Enhancing Thomson scattering polychromator performance with multi-pass spectral filters

In photon-deficient, noncollective Thomson scattering diagnostics, filter polychromators are typically employed in the spectral analysis of Thomson-scattered signals to achieve acceptable signal-to-noise performance. Currently, the most common polychromator filter configuration employs a set of single-passband optical filters that define individual spectral channels. Here, we introduce a new spectral analysis method for Thomson scattering based on spectral filters with multiple passbands, referred to as Thomson scattering spectral multiplexing. Implementing multi-bandpass spectral filters on polychromators increases the achievable range of electron temperature measurement for a given number of filters employed. In addition, Thomson scattering spectral multiplexing reduces systematic measurement uncertainty, with fewer required spectral channels, thereby decreasing light loss from reduced optical element interactions. A multi-bandpass filter set, optimized by a genetic algorithm, has been successfully installed and tested on the Helically Symmetric eXperiment (HSX), demonstrating the benefits of the Thomson scattering spectral multiplexing method.

Instruments & Instrumentation↗

Polarized crystal-field spectra of micro particles of the moon

The instrumentation used in the investigation is considered, giving attention also to a block diagram of the apparatus used for measuring crystal-field spectra. The basic object of the studies was to identify the states of transition elements in lunar crystals in order to obtain information on the chemistry of their crystallization history. After spectral measurements were obtained, the crystals were analyzed for major and minor elements using the electron microprobe. Mineral spectra are considered, giving attention to pyroxene, olivine, plagioclase, and lunar glasses.

Mao, H. K.↗

Non-Detection of L-Band Line Emission from the Exoplanet HD 189733b

We attempt to confirm bright non-local thermodynamic equilibrium (non-LTE) emission from the exoplanet HD 189733b at 3.25 microns, as recently reported by Swain et al. based on observations at low spectral resolving power (lambda/delta lambda approximately equals 30). Non-LTE emission lines from gas in an exoplanet atmosphere will not be significantly broadened by collisions, so the measured emission intensity per resolution element must be substantially brighter when observed at high spectral resolving power. We observed the planet before, during, and after a secondary eclipse event at a resolving power lambda/delta lambda equals 27,000 using the NIRSPEC spectrometer on the Keck II telescope. Our spectra cover a spectral window near the peak found by Swain et al., and we compare emission cases that could account for the magnitude and wavelength dependence of the Swain et al. result with our final spectral residuals. To model the expected line emission, we use a general non-equilibrium formulation to synthesize emission features from all plausible molecules that emit in this spectral region. In every case, we detect no line emission to a high degree of confidence. After considering possible explanations for the Swain et at., results and the disparity with our own data, we conclude that an astrophysical source for the putative non-LTE emission is unlikely. We note that the wavelength dependence of the signal seen by Swain et al. closely matches the 2(sub 1/2) band of water vapor at 300 K, and we suggest that an imperfect correction for telluric water is the source of the feature claimed by Swain et al.

Mandell, Avi M.↗

Spectral Measurements of Meteorite Powders: Implications for 433 Eros

One of the goals of the NEAR-Shoemaker mission to 433 Eros was to determine if it has a meteoritic analog. The primary means of making such a link are the X-ray/gamma-ray spectrometers, which measure elemental compositions of the surface, and the multi-spectral imager (MSI) and near-infrared spectrometer (NIS), which measure spectral reflectance. For determining meteoritic analogs using the X-ray/gamma-ray spectrometer data, the primary data used for comparison is the set of bulk chemical analyses of meteorites done by Jarosewich. These bulk chemical analyses were done on samples now found in the Smithsonian's Analyzed Meteorite Powder collection (USNM 7073). For determining meteoritic analogs using MSI/NIS spectral data, the primary data used for comparison is the set of meteoritic spectra compiled by Gaffey. To expand the set of meteoritic spectra available to the scientific community, we have initiated a spectral study of over 70 samples (primarily ordinary chondrites) found in the Smithsonian's Analyzed Meteorite Powder collection and an electron microprobe study of their corresponding thin sections. This set of spectral and compositional data should allow for better constraints on the distribution of meteorites in plots of band area ratios versus Band I centers and the usefulness of equations for deriving mineralogic compositions from band parameters. These spectral data can also be combined with previous spectral studies of other meteorite types such as the primitive achondrites, eucrites, and angrites to determine how useful the derived band parameters are for differentiating between different meteorite classes. These spectral data can also be used for testing the Modified Gaussian Model (MGM) for determining modal abundances and mafic mineral chemistries from reflectance spectra.

Burbine, T. H.↗

Deriving Plasma Densities and Elemental Abundances from SERTS Differential Emission Measure Analysis

We use high-resolution spectral emission line data obtained by the SERTS instrument during three rocket flights to demonstrate a new approach for constraining electron densities of solar active region plasma.We apply differential emission measure (DEM) forward-fitting techniques to characterize the multithermal solar plasma producing the observed EUV spectra, with constraints on the high-temperature plasma from the Yohkoh Soft X-ray Telescope. In this iterative process, we compare line intensities predicted by an input source distribution to observed line intensities for multiple iron ion species, and search a broad range of densities to optimize chi-square simultaneously for the many available density-sensitive lines. This produces a density weighted by the DEM, which appears to be useful for characterizing the bulk of the emitting plasma over a significant range of temperature. This "DEM-weighted density" technique is complementary to the use of density-sensitive line ratios and less affected by uncertainties in atomic data and ionization fraction for any specific line. Once the DEM shape and the DEM-weighted density have been established from the iron lines, the relative elemental abundances can be determined for other lines in the spectrum. We have also identified spectral lines in the SERTS wavelength range that may be problematic

corona↗

Coso Geothermal Spectral Library for Rocks and Minerals

An integrated open mineral spectral library designed to enhance the utility and precision of mineral spectral data for geothermal exploration, developed from a reliable and comprehensive digital dataset for seamless sharing by integrating field data, the USGS spectral library, and pertinent information obtained from Coso geothermal field (Coso) in California. The ASD FieldSpec portable spectrometer was utilized for collecting spectral data, which was subsequently analyzed using the THOR Material Identification tool in ENVI, The Spectral Geologist (TSG) software by CSIRO, and the Fully Constrained Linear Spectral Unmixing algorithm (FCLSU) in MATLAB. Scanning Electron Microscopy (SEM) with a mineralogy-analyzing function was employed to assess the mineral composition of samples, ensuring precise mineralogical analysis. A portable X-ray fluorescence (pXRF) spectrometer was also utilized to gather information on elemental enrichment. A framework for developing spectra data and establishing spectral libraries for various geological cases was proposed within this study. The characteristic spectra of six alteration minerals - alunite, chalcedony, epidote, hematite, kaolinite, and opal - were acquired from Coso samples. The spectral library for the Coso alteration minerals was introduced for further application in academic study or industrial exploration. To browse the Coso Geothermal Spectral data and related figures from spreadsheets: #1 Unzip and store the following items in the same folder. 'Contact Probe Data.zip', 'Sample Photos.zip', and 'Coso spectra of higher-certainity minerals.xlsx'. #2 Open 'Coso spectra of higher-certainity minerals.xlsx'. The hyperlinks in the spreadsheet lead to the folders or figures of: spectra .asd file, spectra ASC II file, spectra plots, and sample photos. The spectra data is raw data without splice correction. Spectra .asd files require particular software to open. (These cannot be opened in GIS software such as ArcGIS.) Spectra ASC II files can be opened in a text editor or spread sheet program.

15 GEOTHERMAL ENERGY↗

Biplex, pipelined FFT

A method of implementing a pipelined fast Fourier transform (FFT) is presented that makes full use of the elements that comprise it. For a given bandwidth and spectral resolution, this approach requires 25 percent less memory, and needs only half the logic speed required for the conventional implementation. Since the spectrum is broken into two parts, two analog-to-digital converters, and attendant mixer-filters, are needed. These two input elements need only operate at half the speed of the one they replaced.

Emerson, R. F.↗

A laser spectrometer and wavemeter for pulsed lasers

The design, construction, calibration, and evaluation of a pulsed laser wavemeter and spectral analyzer are described. This instrument, called the Laserscope for its oscilloscope-like display of laser spectral structure, was delivered to NASA Langley Research Center as a prototype of a laboratory instrument. The key component is a multibeam Fizeau wedge interferometer, providing high (0.2 pm) spectral resolution and a linear dispersion of spectral information, ideally suited to linear array photodiode detectors. Even operating alone, with the classic order-number ambiguity of interferometers unresolved, this optical element will provide a fast, real-time display of the spectral structure of a laser output. If precise wavelength information is also desired then additional stages must be provided to obtain a wavelength measurement within the order-number uncertainty, i.e., within the free spectral range of the Fizeau wedge interferometer. A Snyder (single-beam Fizeau) wedge is included to provide this initial wavelength measurement. Difficulties in achieving the required wide-spectrum calibration limit the usefulness of this function.

Mckay, J. A.↗

Scales of North Atlantic wind stress curl determined from the comprehensive ocean-atmosphere data set

Nineteen years of wind data over the North Atlantic are used to calculate a field of wind stress curl. An empirical orthogonal function (EOF) analysis is performed on this field, resulting in spatial patterns of wind stress curl and associated time series. A Monte Carlo technique is used to establish the statistical significance of each spatial pattern, and the associated time series are spectrally analyzed. The first four statistically significant EOF modes represent more than 50 percent of the curl variance, and the spatial patterns of curl associated with these modes exhibit the major elements of North Atlantic climatology. Most of the time series spectral variance is contained in annual and semiannual frequencies. The features observed include the individual annual variation of the subtropical high and the subpolar low, the annual oscillation of intensity between pressure centers, the influence of localized strong SST gradients and associated cyclogenesis regions, and the constant nature of the trades.

Ehret, Laura L.↗

Attosecond Transient Grating Spectroscopy with Near-Infrared Grating Pulses and an Extreme Ultraviolet Diffracted Probe

Transient grating spectroscopy has become a mainstay among metal and semiconductor characterization techniques. Here, we extend the technique toward the shortest achievable time scales by using tabletop high-harmonic generation of attosecond extreme ultraviolet (XUV) pulses that diffract from transient gratings generated with sub-5 fs near-infrared (NIR) pulses. We demonstrate the power of attosecond transient grating spectroscopy (ATGS) by investigating the ultrafast photoexcited dynamics in an Sb semimetal thin film. ATGS provides an element-specific, background-free signal unfettered by spectral congestion, in contrast to transient absorption spectroscopy. With ATGS measurements in Sb polycrystalline thin films, we observe the generation of coherent phonons and investigate the lattice and carrier dynamics. Among the latter processes, we extract carrier thermalization, hot carrier cooling, and electron-hole recombination, which are on the order of 20 fs, 50 fs, and 2 ps time scales, respectively. Furthermore, the simultaneous collection of transient absorption and transient grating data allows us to extract the total complex dielectric constant in the sample dynamics with a single measurement, including the real-valued refractive index, from which we are also able to investigate carrier-phonon interactions and longer-lived phonon dynamics. The outlined experimental technique expands the capabilities of transient grating spectroscopy and attosecond spectroscopies by providing a wealth of information concerning carrier and lattice dynamics with an element-selective technique at the shortest achievable time scales.

Quintero-Bermudez, Rafael↗

Data acquisition and preprocessing techniques for remote sensing field research

A crops and soils data base has been developed at Purdue University's Laboratory for Applications of Remote Sensing using spectral and agronomic measurements made by several government and university researchers. The data are being used to (1) quantitatively determine the relationships of spectral and agronomic characteristics of crops and soils, (2) define future sensor systems, and (3) develop advanced data analysis techniques. Researchers follow defined data acquisition and preprocessing techniques to provide fully annotated and calibrated sets of spectral, agronomic, and meteorological data. These procedures enable the researcher to combine his data with that acquired by other researchers for remote sensing research. The key elements or requirements for developing a field research data base of spectral data that can be transported across sites and years are appropriate experiment design, accurate spectral data calibration, defined field procedures, and through experiment documentation.

Biehl, L. L.↗

Far-infrared observations of thermal dust emission from supernova 1987A

Observations of SN1987A in the spectral range 18-35 microns taken on November 16 and 23, 1988, 632 and 639 days after core collapse, are reported. A strong and rather flat continuum underlies weak fine-structure lines from heavy elements and declines slowly between 24 and 30 microns. The spectral shape indicates thermal emission from an almost featureless dust component, probably graphite, with silicates contributing less than 20 percent of the emitting dust mass. Some of the emission may be an 'echo' of supernova light reflected from a preexisting dust cloud, but a better explanation which can account for the entirety of emission from infrared to gamma wavelengths, is that dust is being formed in the supernova ejecta. This also accounts more naturally for the inferred dust composition.

Moseley, S. H.↗

Inorganic characterization of switchgrass biomass using laser-induced breakdown spectroscopy

The inorganic characterization of 74 samples of switchgrass using laser-induced breakdown spectroscopy (LIBS) was undertaken. Determination of ash and inorganic elements content in biomass materials is vital for feedstock screening for bioconversion processes. Hierarchical models using principal component analysis (PCA) and partial least square analysis (PLS) were used to determine the presence of specific elemental micronutrients that are important in determining plant health for robust biomass production. LIBS uses a 532 nm laser with 45 mJ of laser power to excite the samples of switchgrass plant material and the emission of all the elements present in the plant samples were recorded in single spectra with a wide wavelength range of 200–800 nm. The results were compared to the laboratory standard technique, e.g., ICP-OES technique, to determine the true values for major micronutrients such as, silicon (Si), potassium (K), calcium (Ca), magnesium (Mg), phosphorus (P), and sulfur (S). Overall, our objectives were: 1) To determine the spectral features of switchgrass containing different amounts of these elements and 2) To examine the viability of this technique for determining the quality of the feedstock in terms of its inorganic composition. Cross-validation results showed that the broad-based model developed is promising for inorganics prediction in switchgrass. The LIBS validation prediction for the micronutrient elements mentioned here have been obtained. The regression coefficients for Si, were obtained to be 0.995, 0.994 for calibration and validation respectively, in case of Ca the regression coefficients were, 0.994 and 0.992 for calibration and validation. Similarly, in the case of Mg and K these were calculated to be 0.992 and 0.985, and 0.994 and 0.993 respectively. The regression coefficients are not as good as those for the elements mentioned, in case of the two elements S and P. They are 0.957, and 0.878, and 0.952 and 0.894 respectively for calibration, validation for the two elements. This demonstrates that LIBS-based techniques are inherently well suited for diverse environmental applications. Furthermore, LIBS along with PLS model can show capability in determining the viability of switchgrass as a biomass in the production of biofuels and survivability of switchgrass in processes associated with climate change. LIBS can help determining which switchgrass would be appropriate for a specific conversion process that favors low ash content overall or low value of specific inorganics.

59 BASIC BIOLOGICAL SCIENCES↗

Time-resolved chemically-selective spectroscopic investigation of the redox reaction between hematite and aluminium

Thermite reactions –highly energetic redox processes between a metal and an oxide—are used in welding, propulsion, and the fabrication of advanced materials. When reduced to the nanoscale, these reactions exhibit enhanced energetic performance, but their ultrafast dynamics remain poorly understood. Gaining insight into charge transfer during these processes is essential for advancing applications in energy conversion and materials design. Here we show that the reaction between aluminium and hematite, a common iron oxide, can be tracked with femtosecond resolution using extreme ultraviolet (EUV) time-resolved absorption spectroscopy at the Fe M 2,3 and Al L 2,3 edges. By exciting the system with an ultrashort optical pulse and probing element-specific absorption changes, we observe an early spectral shift that reveals the formation of localized charge carriers (polarons). Comparing samples with different supporting substrates highlights ultrafast electron transfer from aluminium to hematite. These results demonstrate an approach to investigating charge flow in energetic materials and provide a basis for studying fast chemical reactions with chemical specificity.

Electron transfer↗

Commissioning the H i Observing Mode of the Beam Former for the Cryogenically Cooled Focal L-band Array for the GBT (FLAG)

We present the results of commissioning observations for a new digital beam-forming back end for the Focal plane L-band Array for the Robert C. Byrd Green Bank Telescope (FLAG), a cryogenically cooled Phased Array Feed (PAF) with the lowest measured T {sub sys}/η of any PAF outfitted on a radio telescope to date. We describe the custom software used to apply beam-forming weights to the raw element covariances to create research-quality spectral-line images for the new fine-channel mode, study the stability of the beam weights over time, characterize FLAG’s sensitivity over a frequency range of 150 MHz, and compare the measured noise properties and observed distribution of neutral hydrogen emission from several extragalactic and Galactic sources with data obtained with the current single-pixel L-band receiver. These commissioning runs establish FLAG as the preeminent PAF receiver currently available for spectral-line observations on the world’s major radio telescopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared coronal lines. II.

Wavelengths and intensities of IR coronal lines of silicon and magnesium ions from airborne total solar eclipse observations

CORONA↗