Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Experiment definition and integration study for the accommodation of magnetic spectrometer payload on Spacelab/shuttle missions

A super-cooled magnetic spectrometer for a cosmic-ray experiment is considered for application in the high energy astronomical observatory which may be used on a space shuttle spacelab mission. New cryostat parameters are reported which are appropriate to shuttle mission weight and mission duration constraints. Since a super-conducting magnetic spectrometer has a magnetic fringe field, methods for shielding sensitive electronic and mechanical components on nearby experiments are described.

Buffington, A.↗

Infrared Fabry-Perot and heterodyne spectrometers

The status of infrared instrumentation for astronomical investigations at U.C. Berkeley is described with emphasis on the techniques of high spectral and spatial resolution. Present instrumentation includes three Fabry-Perot spectrometers for the 10, 20, and 100 micron wavelength regions, a submillimeter receiver using an optically pumped laser, a 10 micron heterodyne spectrometer for studies of planetary atmospheres, and a 2-element 10 micron stellar interferometer for measuring the angular diameters of infrared stars.

Betz, A.↗

A technique for mass spectrometer measurements of atomic and molecular oxygen in the lower thermosphere

A neutral mass spectrometer with a quasi-open ion source was flown on each of the Atmosphere Explorer (AE) C, D, and E satellites. The three instruments provided an opportunity to study the effects of different source insert materials on the source surface chemistry. It was found that, after a period of conditioning in space, the recombination coefficient of atomic oxygen on gold appears to be substantially lower than it is on Nichrome V. The lower recombination coefficient on gold allows the spectrometer to directly measure a significant fraction of the incident atomic oxygen, making it possible to distinguish between ambient O and O2. Equations are developed to calculate the atomic and molecular oxygen densities. Preliminary measurements of molecular oxygen densities obtained by this technique agree well with measurements taken in the fly-through mode of operation.

Kayser, D. C.↗

A 10 micron laser heterodyne spectrometer for remote detection of trace gases

Infrared heterodyne spectroscopy provides a means of measuring the intensity profiles of individual rotation-vibration spectral lines with high sensitivity. Considerable effort has been expended on optimizing these instruments for remote measurements of gases in planetary atmospheres with the result that present-generation spectrometers are beginning to provide new and startling results on the planets. The fundamental principles of laser heterodyne spectroscopy are discussed. Detailed considerations of the optical design and the electronic design of the spectral-line receiver are given. Representative results obtained with this spectrometer are discussed, including precision frequency measurements of NH3 (nu-2) lines, detection of auroral emission from Jupiter, and measurements of terrestrial O3 and CO2.

Mumma, M. J.↗

Stratospheric ozone measurement with an infrared heterodyne spectrometer

Measurements of a stratospheric ozone concentration profile are made by detecting infrared absorption lines with a heterodyne spectrometer. The infrared spectrometer is based on a line-by-line tunable CO2 lasers, a liquid-nitrogen cooled HgCdTe photomixer, and a 64-channel spectral line receiver. The infrared radiation from the source is mixed with local-oscillator radiation. The difference frequency signal in a bandwidth above and below the local-oscillator frequency is detected. The intensity in each sideband is found by subtracting sideband contributions. It is found that absolute total column density is 0.32 plus or minus 0.02 cm-atm with a peak mixing ratio at about 24 km. The (7,1,6)-(7,1,7) O3 line center frequency is identified as 1043.1772/cm. Future work will involve a number of ozone absorption lines and measurements of diurnal variation. Completely resolved stratospheric lines may be inverted to yield concentration profiles of trace constituents and stratospheric gases.

Abbas, M. M.↗

Typhoon June /1975/ viewed by a scanning microwave spectrometer

Data were collected by the scanning microwave spectrometer onboard Nimbus 6 during the June 1975 typhoon in the Philippine Sea. The spectrometer was equipped with channels centered on 22.23 GHz (a water vapor band), 31.65 GHz (a transmittance window), and 52.85, 53.85, and 55.45 GHz (an oxygen band). Temperature maps, derived from oxygen band measurements, showed that the typhoon eye had a single peak varying in amplitude with time. Water line and window measurements were used to develop a coordinate system having mutually orthogonal atmospheric variables of column water-vapor content and cloud liquid-water content. Vapor measurements showed a maximum around the intensifying typhoon with a more developed structure during typhoon development. Values were extrapolated for surface wind speed and cloud liquid water vapor content by assuming the troposphere to be saturated with respect to the water vapor in the typhoon. Comparisons with infrared cloud imagery and aircraft flight data show different time variations, attributed to poor typhoon-eye resolution in the microwave images.

Rosenkranz, P. W.↗

The curved crystal X-ray spectrometer for the HEAO-B satellite

The Focal Plane Crystal Spectrometer on HEAO-B is a moderate to high resolution, curved-crystal, Bragg spectrometer which operates behind a grazing incidence X-ray telescope. It is designed to allow detailed spectral studies of both point and extended celestial X-ray sources in the energy range 0.2-3.3 keV, with resolutions of 50 to 1000. The analyzing elements are six torroidal diffractors, and the detectors are position-sensitive, flow, proportional counters. HEAO-B is scheduled for launch in June, 1978.

Canizares, C. R.↗

Balloon-borne photoionization mass spectrometer for measurement of stratospheric gases

A balloon-borne photoionization mass spectrometer used to measure stratospheric trace gases is described. Ions are created with photons from high-intensity krypton discharge lamps and a quadrupole mass analyzer is employed for ion identification. Differential pumping is achieved with liquid helium cryopumping. To insure measurement of unperturbed stratospheric air, the entire system is contained in a sealed gondola and the atmospheric sample is taken some distance away during descent. The photoionization technique allows the detection of a low ionization potential constituent, such as nitric oxide, at less than a part in one billion in the presence of the major atmospheric gases and their isotopes. Operation of the mass spectrometer system was demonstrated during a daytime flight from Palestine, Texas on 26 April 1977. The sensitivity achieved and the unique selectivity afforded by this technique offer a capability for trace constituent measurement not possible with the more conventional electron impact ionization approach.

Aikin, A. C.↗

Gas densities near 230 km from orbital drag and mass spectrometer measurements - A comparison

Perigee density data near 230 km for the Aeros satellite are analyzed for more than 1000 orbits. A comparison method for such data was developed which is based on the observed rate of change of orbital period as compared with the orbital decay computed from mass-spectrometer data obtained at discrete positions along the orbit. In general, the method confirms the good agreement of the average ratio of in-situ and orbit-drag-inferred perigee densities. In the case of Aeros, absolute densities measured by the NATE mass spectrometer are confirmed.

Roemar, M.↗

Recent developments and applications with gas cell correlation spectrometer

Gaspec, a gas filter correlation spectrometer, is described. Gaspec is a dual-gas three-channel instrument using two detectors which receive amplitude-shared source signals modulated at the frequency of the chopper. Several units for operation around the 3-5 micron and the 8-15 micron region have been constructed, and gases such as CO2, CO, CH4, HCl, NO, and hydrazines can be detected. Advantages of Gaspec are considered with reference to improvements developed for the basic Cospec (gas cell correlation spectrometer) instrument.

Barringer, A. R.↗

Si XIII and Si XIV line emission search with the ANS crystal spectrometer

The final results of the search for Si XIII and Si XIV line emission, using the ANS Bragg crystal spectrometer, are presented. No positive line detection was achieved in any of the measurements made on several types of cosmic object; i.e., a transient X-ray source, close binary systems, supernova remnants, GX sources, and clusters of galaxies. Three-sigma upper limits for discrete line emission from these objects are reported and compared with line strengths inferred from other proportional-counter and Bragg spectrometer data. The present upper limit of 1.0 eV for the equivalent width of a narrow Si XIV line emission from the X-ray nova A0620-00 is an order of magnitude lower than previous limits set by other experiments.

Parsignault, D. R.↗

An imaging X-ray spectrometer to study solar activity in conjunction with the SCADM program

An experiment is proposed to study solar active region dynamics and evolution. The experiment will employ an imaging X-ray spectrometer to study solar activity in conjunction with the SCADM program. A summary of the experiment is presented which includes the specifications and capabilities of the X-ray spectrometer, the scientific objectives, the method of approach, and a comparison of the experiment with other solar X-ray experiments. The experiment is proposed for use on the space shuttle due to its larger volume and weight capacity.

Blake, R. L.↗

Optical considerations in infrared heterodyne spectrometer design

The optical design considerations for optimization of sensitivity, tunability, and versatility of an infrared heterodyne spectrometer are discussed using the GSFC CO2 laser heterodyne spectrometer optical front end as an example. Problems related to the coherent nature of the laser local oscillator beam (e.g., interference effects at edges of optical elements and at the beam combining beamsplitter) are described and proper beamsplitter design discussed. Optimum matching to the telescope is discussed. The severe effects of large central obscuration on the coherent telescope efficiency are described and steps to partially recover the lost system sensitivity are proposed. Measurements made with the GSFC 48 inch telescope (linear obscuration rate = 0.5) and the KPNO McMathe telescope (no obscuration) are given as examples.

Kostiuk, T.↗

Acousto-optic spectrometer for radio astronomy

A prototype acousto-optic spectrometer which uses a discrete bulk acoustic wave Itek Bragg cell, 5 mW Helium Neon laser, and a 1024 element Reticon charge coupled photodiode array is described. The analog signals from the photodiode array are digitized, added, and stored in a very high speed custom built multiplexer board which allows synchronous detection of weak signals to be performed. The experiment is controlled and the data are displayed and stored with an LSI-2 microcomputer system with dual floppy discs. The performance of the prototype acousto-optic spectrometer obtained from initial tests is reported.

Chin, G.↗

Data acquisition techniques for exploiting the uniqueness of the time-of-flight mass spectrometer: Application to sampling pulsed gas systems

Mass spectra are produced in most mass spectrometers by sweeping some parameter within the instrument as the sampled gases flow into the ion source. It is evident that any fluctuation in the gas during the sweep (mass scan) of the instrument causes the output spectrum to be skewed in its mass peak intensities. The time of flight mass spectrometer (TOFMS) with its fast, repetitive mode of operation produces spectra without skewing or varying instrument parameters and because all ion species are ejected from the ion source simultaneously, the spectra are inherently not skewed despite rapidly changing gas pressure or composition in the source. Methods of exploiting this feature by utilizing fast digital data acquisition systems, such as transient recorders and signal averagers which are commercially available are described. Applications of this technique are presented including TOFMS sampling of vapors produced by both pulsed and continuous laser heating of materials.

Lincoln, K. A.↗

Solar maximum ultraviolet spectrometer and polarimeter

The objectives of the UVSP experiment are to study solar ultraviolet radiations, particularly from flares and active regions, and to measure constituents in the terrestrial atmosphere by the extinction of sunlight at satellite dawn and dusk. The instrument is designed to observe the Sun at a variety of spectral and spatial resolutions in the range from 1150 to 3600 A. A Gregorian telescope with effective focal length of 1.8 m is used to feed a 1 m Ebert-Fastie spectrometer. A polarimeter containing rotatable magnesium fluoride waveplates is included behind the spectrometer entrance slit and will allow all four Stokes parameters to be determined. Velocities on the Sun can also be measured. The instrument is controlled by a computer which can interact with the data stream to modify the observing program. The observing modes, including rasters, spectral scans, velocity measurements, and polarimetry, are also described along with plans for mission operations, data handling, and analysis of the observations.

Tandberg-Hanssen, E.↗

Further laboratory studies and stratospheric flight of a mass spectrometer beam system

A gas expansion system combined with a mass spectrometer has been tested and flown successfully in the stratosphere. Through a sequence of orifices and high speed pumping, gas particles were formed into a molecular beam and analyzed by a sensitive mass spectrometer. During two balloon flights, vertical profiles of all major atmospheric constituents as well as O3, CO2, H2O and others were obtained. Gases such as AR38 and O16;O17 provided in-flight calibration standards. The sensitivity of the system was such that gases with mixing ratios of 10 ppb at an ambient pressure of about 10 mbar were detectable.

Mauersberger, K.↗

The Ultraviolet Spectrometer and Polarimeter on the Solar Maximum Mission

The Ultraviolet Spectrometer and Polarimeter (UVSP) on the Solar Maximum Mission spacecraft is described, including the experiment objectives, system design, performance, and modes of operation. The instrument operates in the wavelength range 1150-3600 A with better than 2 arcsec spatial resolution, raster range 256 x 256 sq arcsec, and 20 mA spectral resolution in second order. Observations can be made with specific sets of four lines simultaneously, or with both sides of two lines simultaneously for velocity and polarization. A rotatable retarder can be inserted into the spectrometer beam for measurement of Zeeman splitting and linear polarization in the transition region and chromosphere.

Woodgate, B. E.↗