Search NASA⌕ Search

SEARCH · Search NASA

Results for “TELLURIDE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Fluorescence and phosphorescence of photomultiplier window materials under electron irradiation

The fluorescence and phosphorescence of photomultiplier window materials under electron irradiation were investigated using a Sr-90/Y-90 beta emitter as the electron source. Spectral emission curves of UV grade, optical grade, and electron-irradiated samples of MGF2 and LiF, CaF2, BaF2, sapphire, fused silica, and UV transmitting glasses were obtained over the spectral range of 200 nm to 650 nm. Fluorescence yields, expressed as the number of counts in a solid angle of 2 pi steradian per 1MeV of incident electron energy deposited, were determined on these materials utilizing photomultiplier tubes with cesium telluride, bialkali, and trialkali (S-20) photocathodes, respectively.

Viehmann, W.↗

Nuclear quadrupole resonance studies in semi-metallic structures

Both experimental and theoretical studies are presented on spectrum analysis of nuclear quadrupole resonance of antimony and arsenic tellurides. Numerical solutions for secular equations of the quadrupole interaction energy are also discussed.

Murty, A. N.↗

Skylab experiments on semiconductors and alkali halides

The space processing experiments performed during the Skylab missions included one on single crystal growth of germanium selenide and telluride, one on pure and doped germanium crystals, two on pure and doped indium antimonide, one on gallium-indium-antimony systems, and one on a sodium chloride-sodium fluoride eutectic. In each experiment, three ampoules of sample were processed in the multipurpose electric furnace within the Skylab Materials Processing Facility. All were successful in varying degrees and gave important information about crystal growth removed from the effects of earth surface gravity.

Lundquist, C. A.↗

Very high resolution radiometer

A primary sensor used in environmental and earth-resource observation, the Very High Resolution Radiometer (VHRR) was designed for use on the ITOS D series spacecraft. The VHRR provides a 0.47 mile resolution made possible with a mercury-cadmium-telluride detector cooled to approximately 105 K by a passive radiator cooler. The components of this system are described. The optical subsystem of the VHRR consists of a scanning mirror, a Dall-Kirkham telescope, a dichroic beam splitter, relay lenses, spectral filters, and an IR detector. Signal electronics amplify and condition the signals from the infrared and visible light detector. Sync generator electronics provides the necessary time signals. Scan-drive electronics is used for commutation of the motor winding, velocity, and phase control. A table lists the performance parameters of the VHRR.

Aronson, A. I.↗

Photomultiplier window materials under electron irradiation - Fluorescence and phosphorescence

The fluorescence and phosphorescence of photomultiplier window materials under electron irradiation have been investigated using a Sr-90/Y-90 beta emitter as the electron source. Spectral emission curves of UV-grade, optical-grade, and electron-irradiated samples of MgF2 and LiF, and of CaF2, BaF2, sapphire, fused silica, and UV-transmitting glasses were obtained over the 200-650-nm spectral range. Fluorescence yields were determined on these materials utilizing photomultiplier tubes with cesium telluride, bialkali, and trialkali (S-20) photocathodes, respectively. Optical-grade MgF2 and LiF, as well as electron-irradiated UV-grade samples of these two materials, show enhanced fluorescence due to color-center formation and associated emission bands in the blue and red wavelength regions. Large variations in fluorescence intensities were found in UV-grade sapphire samples of different origins, particularly in the red end of the spectrum, presumably due to various amounts of chromium-ion content. Phosphorescence decay with time is best described by a sum of exponential terms, with time constants ranging from a few minutes to several days.

Viehmann, W.↗

The four- and five-band multispectral scanners for Landsat

The earth resources sensing Multispectral Scanner (MSS) for the Landsat satellite has two versions; one with four spectral bands from 0.5 to 1.1 microns, and one with five bands, the added band being 10.4 to 12.6 microns. This paper describes optical design and performance. The instrument uses a flat, object-space scanning mirror of near-linear motion, with a sensitive optical position monitor to detect mirror angular position. The 22.9-cm aperture telescope images the scene on an array of fiber optics, which dissect and transmit the scene energy to photomultiplier tubes detecting in Bands 1, 2, and 3, and silicon photodiodes detecting Band 4. Band 5 energy passes the fiber optic assembly and is reimaged on a radiatively cooled mercury cadmium telluride (HgCdTe) detector. The orbiting four-band scanner is furnishing data registered to better than 50-m band-to-band and resolving 80-m repetitive pattern over a 185-km swath width from 907-km altitude.

Lansing, J. C., Jr.↗

CO2 laser communication systems for near-earth space applications

Projections of the growth of earth-sensing systems for the latter half of the 1980's show a data-transmission requirement of 300 Mbit/s and above. The most efficient technique to return the data from a sensing satellite to a ground station is through a geosynchronous data relay satellite. A laser system is most attractive for the space-to-space link. A five-year program was conducted which has shown the basic technical feasibility of accomplishing this link with a CO2 laser system operating at a wavelength near 10 microns. The system uses a mercury-cadmium-telluride infrared mixer cooled to approximately 100 K by a radiative cooler. The laser local oscillator and coupling-modulated laser transmitter use conductively cooled beryllium oxide construction. The optical antenna for transmission and reception has a gain of nominally 92 dB with a 3-dB beamwidth of 80 microrad. Tracking jitter is less than ten microrad, and signal acquisition occurs in less than 1 min. The receiver subsystem has a sensitivity of 10 to the -19th power W/Hz, accommodates a 300-Mbit/s data rate, and can track Doppler frequency variations over a + or - 700-MHz range.

Mcelroy, J. H.↗

Results of metallographical diagnostic examination of Navy half-watt thermoelectric converters degraded by accelerated tests

To verify the 15-year reliability of the Navy half-watt radioisotope thermoelectric generator (RTG), bismuth-telluride thermoelectric converters were submitted to testing at high temperatures which accelerated the degradation and caused failure of the converters. Metallographic diagnostic examination of failed units verified failure mechanisms. Results of diagnostic examinations are presented.

Rosell, F. E., Jr.↗

Multilayered (Hg,Cd)Te infrared detector

Multilayered mercury-cadmium telluride photoconductive detectors were developed which are capable of providing individual coverage of three separate spectral wavelength bands without the use of beam splitters. The multilayered "three-color" detector on a single dewar takes the place of three separate detector/filter/dewar units and enables simpler and more reliable mechanical and optical designs for multispectral scanners and radiometers. Wavelength channel design goals (in micrometers) were: 10.1 to 11.0, 11.0 to 12.0, and 13.0. Detectivity for all channels was 1 x 10 to the 10th power cm-Hz 1/2/Watt. A problem occurred in finding an epoxy layer which had good infrared transmission properties and which also was chemically and mechanically compatible with HgCdTe processing techniques. Data on 6 candidate bonding materials are surveyed and discussed.

Rae, W. G.↗

Life test results for an ensemble of CO2 lasers

The effects of cathode material, cathode operating temperature, anode configuration, window materials, and hydrogen additives on laser lifetime are determined. Internally oxidized copper and silber-copper alloy cathodes were tested. The cathode operating temperature was raised in some tubes through the use of thermal insulation. Lasers incorporating thermally insulated silver copper oxide cathodes clearly yielded the longest lifetimes-typically in excess of 22,000 hours. The use of platinum sheet versus platinum pin anodes had no observable effect on laser lifetime. Similarly, the choice of germanium, cadmium telluride, or zinc selenide as the optical window material appears to have no impact on lifetime.

Peruso, C. J.↗

Effects of systemic and non-systemic stresses on the thermal characteristics of corn

Experiments were conducted on corn plants using a calibrated spectroradiometer under field conditions in the indium antimonide channel (InSb, 2.8 to 5.6 mm) and the mercury cadmium telluride channel (HgCdTe, 7 to 14 mm). A ground cover experiment, an experiment on nonsystemic corn plants, and an experiment on systemic-stressed corn plants were included. The average spectral radiance temperature of corn plant populations was found (1) to be statistically significantly different for four healthy corn plant populations, (2) to increase with increased blight severity, and (3) to be statistically significantly different for varying rates of nitrogen applications.

Kumar, R.↗

New works in space

Goods and services that may be furnished by the Space Shuttle are described. A single multibeam antenna array capable of supplying satellite communication for 256 U.S. cities, a disaster warning network, and a TV link to remote areas is discussed. Attention is also given to such materials processing programs as crystal growth (for example, production of mercuric iodide crystals for gamma-ray detectors), eutectic growth of solid-solution crystals such as mercury-cadmium-telluride, manufacture of uniform latex spheres for medical applications, and development of small glass spheres for fusion power applications. In addition to the Space Telescope, a meter-class telescope on the Shuttle and a wide-field survey instrument are under study.

Kingsbury, J. E.↗

Infrared heterodyne spectroscopy for astronomical purposes

Heterodyne infrared astronomy was carried out using CO2 lasers and some solid state tunable lasers. The best available detectors are mercury cadmium telluride photodiodes. Their quantum efficiencies reach values near 0.5 and in an overall system an effective quantum efficiency, taking into account optical losses and amplifier noise, of about 0.25 was demonstrated. Initial uses of 10 micron heterodyne spectroscopy were for the study of planetary molecular spectra.

Townes, C. H.↗

Recent developments in low cost silicon solar cells for terrestrial applications

A variety of techniques may be used for photovoltaic energy systems. Concentrated or not concentrated sunlight may be employed, and a number of materials can be used, including silicon, gallium arsenide, cadmium sulfide, and cadmium telluride. Most of the experience, however, has been obtained with silicon cells employed without sunlight concentration. An industrial base exists at present for producing solar cells at a price in the range from $15 to $30 per peak watt. A major federal program has the objective to reduce the price of power provided by silicon solar systems to approximately $1 per peak watt in the early 1980's and $0.50 per watt by 1986. The approaches considered for achieving this objective are discussed.

Leipold, M. H.↗

High resolution spectrograph for the Space Telescope

The high resolution spectrograph (HRS) for ultraviolet astronomy with the Space Telescope will provide a spectral resolution of approximately 120,000 over a nominal wavelength range of 110-320 nm, together with a spatial resolution of about 0.25 arc seconds. The two detectors will consist of 512-element Digicons with cesium telluride and cesium iodide photocathodes, respectively. Photoelectrons in transit between the photocathodes and the diodes within the Digicons can be deflected in two axes with 12-bit resolution. This feature facilitates a design that emphasizes reliability since (once a hermetic seal is opened in orbit), only two moving parts, a grating carrousel and a shutter, are required for regular operation of the HRS. The instrument will be controlled by a computer in the spacecraft. The scientific objectives of the HRS investigation relate to interstellar matter in our own and nearby galaxies, physical processes of stellar mass loss and mass transfer, chemical abundances, bright quasars and Seyfert galaxy nuclei, and solar system phenomena.

Brandt, J. C.↗

Wide-field electrographic cameras for imagery and spectrography at visual and middle-UV wavelengths

The use of a Kron electrographic detector for wide-field, narrow-band imagery of faint emission nebulosity in the near-UV and visual (3100-6000 A) wavelength interval is described. As an example of the photometric quality of the imagery and of the sensitivity of the instrumentation to diffuse, low-contrast objects, imagery of the Cygnus Loop supernova remnant in the high excitation forbidden line of Ne V 3426 A is presented. In addition, a program to develop electrographic detectors which use cesium telluride photocathodes for broad-band imagery and spectrography in the middle-UV (1650-3100 A) wavelength range is described.

Heckathorn, H. M.↗