Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing Procedure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Fitting Leak Test Report: Ground-Based Cryogenic Leak Test of Fittings for Cryogenic Fluid Management

EXECUTIVE SUMMARY Mechanically connected joints used in cryogenic fluid lines as part of space flight elements need to survive launch vibrations and remain leak-free to minimize the loss of on-board commodity and hazardous gas accumulation. In 2020, a cryogenic test apparatus was developed which can evaluate the leak performance of pressurized threaded fluid fittings. The fittings were mounted in the TVAC and cooled to cryogenic test temperature and pressurized with helium while the leak rate was measured using a calibrated GHe leak detector. The test articles for the initial proof of concept testing were ¼ and 1 inch Swagelok VCR fittings with three different types of seal rings copper, nickel, and Ni. Each fitting configuration (size/seal material) was subjected to two consecutive cryogenic thermal cycles, followed by exposure to a launch vibration profile at ambient temperature, after which two additional TVAC cycle tests were performed. The testing reported here is a continuation of the 2020 tests with a statistically significant large number of samples and test runs. Three Swagelok VCR fitting sizes were tested ¼, ½ and 1 inch, and five (5) samples of each fitting size, each sample was tested with SST and Ni seal rings (Total of 30 unique test articles). Each test article was subjected to four (4) thermal cycles. Half of these cycles were performed before vibration testing and half were performed after vibration testing. The vibration testing was performed to evaluate the ability of the fittings to survive launch-type vibration profiles and remain leak-free. Leak checking of each fitting was completed at temperatures between 20K – 30K. The test procedure in Section 8.0 was designed to facilitate a qualification test program by allowing a higher test throughput rate coupled with repeatable test profiles. Results were very positive and show that out of the 30 samples they all passed with leak rates a factor of 2-3 lower than the established 10-6sccs GHe leak threshold. The result showed the Ni seals had lower leak rate, but the SST was more rugged. There were two deviations where damage to the Ni seal ring during assembly resulted in a leaky fitting, this is discussed in Section 10.7 Test Deviations. These fittings show great promise for space flight use and further testing is recommended to fully qualify the fittings per the ASTM F1387-19 and/or other relevant NASA specifications. The test equipment hardware and software capability developed for this testing is generic and not restricted to VCR fittings. It can be employed to evaluate/qualify the leak performance of other types of fittings and a wide range of other cryogenic fluid components such as valves, gages, connectors, etc.

Cryogenic↗

Prediction of stable crack growth and instability using the V sub R-curve method

A methodology is presented for predicting stable crack growth and instability of cracked structural components from results of laboratory tests on metallic materials under plane-stress conditions. The methodology is based on the displacement V sub R at the tip of a stably tearing crack. Basically, the V sub R-curve method is a resistance curve approach, such as K sub R and J sub R, except that the 'crack drive' is written in terms of crack-tip displacement instead of K or J. The relationship between crack-tip-opening displacement, crack length, specimen type, and tensile properties is derived from the Dugdale model for the cracked structure of interest. This report describes the laboratory test procedure and calculations used to obtain the V sub R resistance curve from fracture tests of compact or of middle-crack tension (formally center-crack) specimens. The analysis procedure used to predict stable crack growth and instability of any through-the-thickness crack configuration made of the same material and thickness, and tested under the same environmental conditions, is presented. The various limitations of the present V sub R curve method are given. Four example calculations and predictions are shown.

Newman, J. C., Jr.↗

Engine isolation for structural-borne interior noise reduction in a general aviation aircraft

Engine vibration isolation for structural-borne interior noise reduction is investigated. A laboratory based test procedure to simulate engine induced structure-borne noise transmission, the testing of a range of candidate isolators for relative performance data, and the development of an analytical model of the transmission phenomena for isolator design evaluation are addressed. The isolator relative performance test data show that the elastomeric isolators do not appear to operate as single degree of freedom systems with respect to noise isolation. Noise isolation beyond 150 Hz levels off and begins to decrease somewhat above 600 Hz. Coupled analytical and empirical models were used to study the structure-borne noise transmission phenomena. Correlation of predicted results with measured data show that (1) the modeling procedures are reasonably accurate for isolator design evaluation, (2) the frequency dependent properties of the isolators must be included in the model if reasonably accurate noise prediction beyond 150 Hz is desired. The experimental and analytical studies were carried out in the frequency range from 10 Hz to 1000 Hz.

Unruh, J. F.↗

Laser geodynamic satellite/thermal/optical vibrational analyses and testing. Volume 2: Technical report, book 3

The overall plan for accomplishing the various tests required to achieve the program objectives and tasks of the LAGEOS thermal/optical/vibration analysis and test program is described. The requirements for each test are identified for the purpose of program review for the design and fabrication of the required test article and test fixtures, for the allocation of test facilities, equipment and expendables, and for the generation of the detail test procedures by which the specified data will be obtained at specified test conditions. The current internal test program schedules, by which the various individual preparatory subtasks are to be accomplished to ensure that the individual test will be conducted within the time period required to meet program objectives are included.

Source record↗

Transonic wind tunnel tests of A.015 scale space shuttle orbiter model, volume 1

Transonic wind tunnel tests were run on a 0.015 scale model of the Space Shuttle Orbiter Vehicle in an eight-foot tunnel during August 1975. The purpose of the program was to obtain basic shuttle aerodynamic data through a full range of elevon and aileron deflections, verification of data obtained at other facilities, and effects of Reynolds numbers. The first part of a discussion of test procedures and results in both tabular and graphical form were presented. Tests were performed at Mach numbers from 0.35 to 1.20, and at Reynolds numbers for 3.5 million to 8.2 million per foot. The angle of attack was varied from -1 to +20 degrees at sideslip angles of -2, 0, +2 degrees. Sideslip was varied from -6 to +8 degrees at constant angles of attack from 0 to +20 degrees. Various aileron and ailevon settings were tested for various angles of attack.

Struzynski, N. A.↗

Transonic wind tunnel tests of a .015 scale space shuttle orbiter model, volume 2

Transonic wind tunnel tests were run on a 0.015 scale model of the Space Shuttle Orbiter Vehicle in an eight-foot tunnel during August 1975. The purpose of the program was to obtain basic shuttle aerodynamic data through a full range of elevon and aileron deflections, verification of data obtained at other facilities, and effects of Reynolds numbers. The second part of a discussion of test procedures and results in both tabular and graphical form were presented. Tests were performed at Mach numbers from 0.35 to 1.20, and at Reynolds numbers from 3.5 million to 8.2 million per foot. The angle of attack was varied from -2 to +20 degrees at sideslip angles of -2, 0, +2 degrees. Sideslip was varied from -6 to +8 degrees at constant angles of attack from 0 to +20 degrees. Various aileron and ailevon settings were tested for various angles of attack.

Struzynski, N. A.↗

Aerodynamic instability performance of an advanced high-pressure-ratio compression component

The data acquisition and reduction, test procedures, and results of in-stall and in-surge testing of a NASA high-pressure-ratio compression component are discussed, in addition to the compressor-rig configuration and instrumentation used. Data analysis revealed information about rotating stall hysteresis, rotating stall development and cessation times, and rotating-stall-cell flow blockage. It is found that hysteresis exists in the work coefficient as well as in the pressure coefficient. Airflow rakes were designed to study the in-surge transient response of the compressor. The quasi-steady compressor characteristics underlying the transient-surge data were investigated using a parameter-identification technique.

Hosny, W. M.↗

Using silicon diodes for detecting the liquid-vapor interface in hydrogen

Tests were performed using commercially available silicon diode temperature sensors to detect the location of the liquid-vapor interface in hydrogen during ground test programs. Results show that by increasing the current into the sensor, silicon diodes can be used as liquid level point sensors. After cycling the sensors from liquid to vapor several times, it was found that with a 30 mA (milliamps) input current, the sensors respond within 2 seconds by measuring a large voltage difference when transitioning from liquid to vapor across the interface. Nearly instantaneous response resulted during a transition form vapor to liquid. Detailed here are test procedures, experimental results, and guidelines for applying this information to other test facilities.

Dempsey, Paula J.↗

Using silicon diodes for detecting the liquid-vapor interface in hydrogen

Tests were performed using commercially available silicon diode temperature sensors to detect the location of the liquid-vapor interface in hydrogen during ground test programs. Results show that by increasing the current into the sensor, silicon diodes can be used as liquid level point sensors. After cycling the sensors from liquid to vapor several times, it was found that with a 30 mA (milliamps) input current, the sensors respond within 2 seconds by measuring a large voltage difference when transitioning from liquid to vapor across the interface. Nearly instantaneous response resulted during a transition from vapor to liquid. Detailed here are test procedures, experimental results, and guidelines for applying this information to other test facilities.

Dempsey, Paula J.↗

Measurements of a deep space station fractional frequency stability to the 10 exp -15 level

This article presents techniques for measuring frequency stability of a deep space station that was configured with a new X-band transmitter subsystem to enable high-quality radio science data to be obtained for a Gravity Wave Experiment. The instrument and test procedures for performing frequency stability measurements in the field are described. Test results from measurements made on various transmit receive subsystems, as well as the overall transmit-receive end-to-end systems below the antenna feed horn are presented. The subsystem test data proved to be useful for assessing the frequency stabilities of various subsystems. This assessment design improvements needed to meet stringent frequency stability requirements for forthcoming gravity wave experiments.

Otoshi, Tom Y.↗

Tension fracture of laminates for transport fuselage. Part 1: Material screening

Transport fuselage structures are designed to contain pressure following a large penetrating damage event. Application of composites to fuselage structures requires a data base and supporting analysis on tension damage tolerance. Tests with 430 fracture specimens were used to accomplish the following: (1) identify critical material and laminate variables affecting notch sensitivity, (2) evaluate composite failure criteria, and (3) recommend a screening test method. Variables studied included fiber type, matrix toughness, lamination manufacturing process, and intraply hybridization. The laminates found to have the lowest notch sensitivity were manufactured using automated tow placement. This suggests a possible relationship between the stress distribution and repeatable levels of material inhomogeneity that are larger than found in traditional tape laminates. Laminates with the highest notch sensitivity consisted of toughened matrix materials that were resistant to a splitting phenomena that reduces stress concentrations in load bearing plies. Parameters for conventional fracture criteria were found to increase with the crack length of the smallest notch sizes studied. Most materials and laminate combinations followed less than a square root singularity for the largest crack sizes studied. Specimen geometry, notch type, and notch size were evaluated in developing a screening test procedure. Results indicate that a range of notch sizes must be tested to determine notch sensitivity.

Walker, T. H.↗

Strength Analysis Report Flight Readiness Review (FRR) for SXI Stepper Motor/Encoder

The strength analysis report for FRR shall include only revisions to update the strength analysis reports for the flight design configuration. Since there have been no revisions to the design configuration since the PDR and the CDR this report shall consist of re-submitting the analysis previously performed. In addition the motors have been subjected to Sine vibration, Random vibration, and shock per the SM specification. Both motor/encoders have passed all three tests. There was no evidence of damage to the motor/encoder and the motor/encoder performed as required by the Acceptance test procedure. No degradation was seen between the before and after performance tests. The testing verified the analysis that there were adequate safety margins with regard to structural integrity. Separate reports are available from the test facility and are apart of the FRR submittal.

Source record↗

Microelectronics Instrument Products Shock and Vibration Electro-Optics: Strength Analysis - Section D

The strength analysis report for FRR shall include only revisions to update the strength analysis reports for the flight design configuration. Since there have been no revisions to the design configuration since the PDR and the CDR this report shall consist of re-submitting the analysis previously performed. In addition the motors have been subjected to Sine vibration, Random vibration, and shock per the SXI specification. Both motor/encoders have passed all three tests. There was no evidence of damage to the motor/encoder and the motor/encoder performed as required by the Acceptance test procedure. No degradation was seen between the before and after performance tests. The testing verified the analysis that there were adequate mf@ty margins with regard to structural integrity. Separate reports are available from the test facility and are apart of the FRR submittal.

Source record↗

Refinements to the Mixed-Mode Bending Test for Delamination Toughness

The mixed-mode bending (MMB) test for delamination toughness was first introduced in 1988. This simple test is a combination of the standard Mode I (opening) test and a Mode II (sliding) test. This MMB test has become widely used in the United States and around the world for mixed-mode toughness measurements. Because of the widespread use of this test method, it is being considered for standardization by ASTM Committee D30. This paper discusses several improvements to the original test method. The improvements to the MMB test procedure include an improved method for calculating toughness from the measured test quantities, a more accurate way of setting the mixed-mode ratio to be tested, and the inclusion of a new alignment criterion for improved consistency in measured values.

Reeder, James R.↗

Closeout Report for the Refractory Metal Accelerated Heat Pipe Life Test Activity

With the selection of a gas-cooled reactor, this heat pipe accelerated life test activity was closed out and its resources redirected. The scope of this project was to establish the long-term aging effects on Mo-44.5%Re sodium heat pipes when subjected to space reactor temperature and mass fluences. To date, investigators have demonstrated heat pipe life tests of alkali metal systems up to .50,000 hours. Unfortunately, resources have not been available to examine the effect of temperature, mass fluence, or impurity level on corrosion or to conduct post-test forensic examination of heat pipes. The key objective of this effort was to establish a cost/time effective method to systematically test alkali metal heat pipes with both practical and theoretical benefits. During execution of the project, a heat pipe design was established, a majority of the laboratory test equipment systems specified, and operating and test procedures developed. Procurements for the heat pipe units and all major test components were underway at the time the stop work order was issued. An extremely important outcome was the successful fabrication of an annular wick from Mo-5%Re screen (the single, most difficult component to manufacture) using a hot isostatic pressing technique. This Technical Publication (TP) includes specifics regarding the heat pipe calorimeter water-cooling system, vendor design for the radio frequency heating system, possible alternative calorimeter designs, and progress on the vanadium equilibration technique. The methods provided in this TP and preceding project documentation would serve as a good starting point to rapidly implement an accelerated life test. Relevant test data can become available within months, not years, and destructive examination of the first life test heat pipe might begin within 6 months of test initiation. Final conclusions could be drawn in less than a quarter of the mission duration for a long-lived, fission-powered, deep space probe.

Martin, J.↗

High Pressure Vent Line Mishap: Investigation Summary

During testing on the E-1 Test Stand, the High Pressure (HP) Liquid Hydrogen (LH) vent line was displaced off its supports, damaging the expansion joints (EJ), piping, and pipe supports of the line. The damage to the vent line is believed to have occurred during Cell 3 testing on Thursday, September 21, during the first test of the day. The fuel systems being used for Cell 3 testing are connected to the LP and HP LH Vent systems and are being used in Liquid Natural Gas (LNG) service. The Cell 3 interface bleed valve that discharges to the HP LH Vent system was inadvertently left at 100% open during the chill-in process for longer than the typical amount of time. Since this valve is usually at a lower set point or intermittently closed during the chill-in process, more than the typical amount of LNG flowed into the vent line as pre-test procedures continued as normal. The open bleed valve was noticed before test preparations were completed and prior to refilling of the HP LH Tank before test. The test sequence was started, run, and shutdown normally. Video of the flare stack showed an atypical discharge of liquid at the flare stack exit. Pressure downstream of the Cell 3 interface bleed valve (a valve connected to the southernmost part of the vent system) spiked to a higher-than-normal level. No evidence of damage was captured at the time of the event. The system was used in a typical fashion after the event and for 4 subsequent tests on Thursday and Friday, before the damage was observed. A drive-by inspection of the flare stack was performed on Friday (September 22nd) morning before sunrise and before test activities began, but no damage of the vent line was observed at that time. No abnormal system behavior was observed during testing on Friday. The damage was discovered and reported to NASA Test Operations on Monday, initiating the Incident Response Team. The Mishap appointment letter was issued September 27th to formally initiate the Mishap Investigation.

LNG↗

Final Status Report Confirming Completion of Mechanical Testing of HFIR Irradiated Nanocomposite Materials

This report provides a final status report on the in-cell mechanical testing of High Flux Isotope Reactor (HFIR)-irradiated nanodispersion-strengthened materials at the Irradiated Materials Examination and Testing (IMET) facility. All tension tests were performed at room temperature with a nominal strain rate of 0.018 mm/mm/min using shoulder-loading grip sets by following the standard testing procedure in ASTM E8/E8M. Round 1 (unirradiated) and round 2 (0.7 dpa) testing was completed in FY 2021. This report confirms completion of round 3 (1.4 dpa) and round 4 (2.1 dpa) tensile testing in FY 2022 with examples of test data collected on select sample conditions. Additionally, the report includes IDs of samples selected for shipment to Idaho National Laboratory (INL) for additional characterization.

36 MATERIALS SCIENCE↗

Energy Northwest - Horn Rapids Solar and Storage: An Assessment of Battery Technical Performance

Chartered in 1957 as a joint action agency of the state, Energy Northwest (ENW) is a consortium of 27 public utility districts and municipalities across Washington state. ENW takes advantage of economies of scale and shared services to help utilities run their operations more efficiently and at lower cost, to the benefit of more than 1.5 million customers. ENW develops, owns, and operates a diverse mix of electricity generating resources, including hydro, solar, and wind projects – and the Northwest’s only active nuclear energy facility. These projects provide enough reliable, affordable, and environmentally responsible energy to power more than a million homes each year, and that carbon-free electricity is provided at the cost of generation. The agency continually explores new generation projects to meet its members’ needs. In 2017, as part of the second round of funding from the Washington state Clean Energy Fund, the Washington State Department of Commerce granted up to $3 million in matching funds to develop an estimated $6.5 million project that deployed a 4-MW, 20-acre solar generating array of photovoltaic (PV) panels coupled with a 1 MW/5.5 MWh lithium-iron-phosphate battery energy storage system (BESS) in Richland, Washington. The combination of PV and BESS will provide a predictable, renewable generating source and will also serve as a training ground for solar and battery technicians throughout the nation. The City of Richland will purchase the power from the project and utilize the benefits of the energy storage. The project provides Washington state with its first opportunity to integrate a large-scale solar and storage facility into its clean mix of hydro, nuclear, and wind resources. This first-of-its-kind facility combines solar generation with battery storage and technician training. In 2019, Pacific Northwest National Laboratory (PNNL) worked with ENW to assess the integrated PV and BESS in representative use cases that could benefit the City of Richland. Between March and May 2022, extensive testing was conducted, and the results were used to assess the technical performance of the BESS subjected to actual field operations. Both reference performance and use case tests were performed: (A) Reference performance tests assess the general technical capabilities of the BESS, such as energy capacity, round-trip efficiency (RTE), ramp rate, and signal tracking capability. These are the first tests performed (baseline), and they are repeated after use case tests (post cycle). A standardized U.S. Department of Energy (DOE) energy storage performance protocol was used to characterize the BESS, including representative duty cycle profiles, test procedure guidance, and calculation guidance for determining key characteristics. (B) Use case tests examine the performance of the BESS for specific use cases using duty cycles developed by PNNL in collaboration with ENW. Five use cases were selected for testing: 1) demand charge reduction, 2) load shaping, 3) transmission charge reduction, 4) Volt-VAR service, and 5) outage mitigation. The use case duty cycles were developed based on utility and site-specific characteristics in addition to the technical characteristics and physical capabilities of the BESS. Use case tests were performed between the baseline and post cycle tests. This report describes the BESS and its components, presents testing and performance analysis results, and shares key insights and lessons learned from this project. Outcomes of the tests and analyses will help ENW understand the performance of the Horn Rapids BESS in its current state and design appropriate operational strategies for this and other BESSs over the long term.

14 SOLAR ENERGY↗