Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal control technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Advances in physics and applications of 3D magnetic perturbations on the J-TEXT tokamak

In the last two years, three major technical improvements have been made on J-TEXT in supporting of the expanded operation regions and diagnostic capabilities. (1) The successful commission of the 105 GHz/500 kW/1 s electron cyclotron resonance heating (ECRH) system increasing the core electron temperature from 0.9 keV up to around 1.5 keV. (2) The poloidal divertor configuration with an X-point in the high-field side has been achieved. In particular, the 400 kW electron cyclotron wave has also been successfully injected into the diverted plasma. (3) A 256-channel electron cyclotron emission imaging diagnostic system and two sets of four-channel Doppler backscattering diagnostics have been successfully developed on J-TEXT, allowing detailed measurement of the electron temperature and density fluctuations for turbulence and MHD research. The locked mode (LM), especially the 2/1 LM, is one of the biggest threats to the plasma operation. Both the thresholds of 2/1 and 3/1 LM are observed to vary non-monotonically on electron density. The electrode biasing was applied successfully to unlock the LM from either a rotating or static resonant magnetic perturbation (RMP) field. In the presence of 2/1 LM, three kinds of standing wave (SW) structures have been observed to share a similar connection to the island structure, i.e. the nodes of the SWs locate around the O- or X-points of the 2/1 island. The control and mitigation of disruption is essential to the safe operation of ITER, and it has been systematically studied by applying a RMP field, massive gas injection (MGI) and shattered pellet injection on J-TEXT. When the RMP-induced 2/1 LM is larger than a critical width, the MGI shutdown process can be significantly influenced. If the phase difference between the O-point of LM and the MGI valve is +90° (or –90°), the penetration depth and the assimilation of impurities can be enhanced (or suppressed) during the pre-thermal quench (TQ) phase and result in a faster (or slower) TQ. A secondary MGI can also suppress the runaway electron (RE) generation, if the additional high-Z impurity gas arrives at the plasma edge before TQ. When the secondary MGI has been applied after the formation of the RE current plateau, the RE current can be dissipated, and the dissipation rate increases with the injected impurity quantity but saturates with a maximum of 28 MA s –1 . The non-local transport is experimentally observed in the ion transport channel. The electron thermal diffusivity significantly increases with the ECRH power. Theoretical work shows that significant intrinsic current can be driven by electromagnetic turbulence, and the robust formation mechanism of the E × B staircase is identified from the Hasegawa–Wakatani system.

divertor↗

Nondestructive ultrasonic characterization of a triple-weld-bead wire arc additively manufactured ER70S-6 S-curved wall

Understanding build-scale microstructural variation in wire arc additive manufacturing (WAAM) of low-carbon steels is essential for ensuring consistent structure–property relationships throughout large components. Conventional destructive characterization techniques, such as scanning electron microscopy (SEM) and electron backscatter diffraction (EBSD), are time-intensive and limited to localized regions, making comprehensive evaluation of large WAAM structures challenging. In this study, a nondestructive ultrasonic approach was employed to characterize a 252 mm tall ER70S-6 S-curved WAAM wall produced using a triple-bead deposition strategy. Optical and SEM analysis revealed a repeating dual-region microstructure consisting of uniform polygonal ferrite at melt pool centers and heterogeneous ferrite with coarse and fine grains near melt pool boundaries, attributed to cyclic thermal conditions. Longitudinal ultrasonic backscatter imaging was used to evaluate the continuity of this periodicity along the full build height. The ultrasonic response exhibited a consistent repeating pattern that correlated with the observed layer-wise microstructural variation. X-ray computed tomography confirmed the absence of detectable porosity, indicating that ultrasonic contrast is primarily governed by grain morphology. Overall, the results indicate that longitudinal backscatter ultrasound is a promising nondestructive characterization technique for validating microstructural variations along the s-curved WAAM wall, with significant potential for microstructure optimization and process control.

36 MATERIALS SCIENCE↗

Relativistic non-thermal particle acceleration in two-dimensional collisionless magnetic reconnection

Magnetic reconnection, especially in the relativistic regime, provides an efficient mechanism for accelerating relativistic particles and thus offers an attractive physical explanation for non-thermal high-energy emission from various astrophysical sources. I present a simple analytical model that elucidates key physical processes responsible for reconnection-driven relativistic non-thermal particle acceleration in the large-system, plasmoid-dominated regime in two dimensions. The model aims to explain the numerically observed dependencies of the power-law index $p$ and high-energy cutoff $\gamma _c$ of the resulting non-thermal particle energy spectrum $f(\gamma )$ on the ambient plasma magnetization $\sigma$ , and (for $\gamma _c$ ) on the system size $L$ . In this self-similar model, energetic particles are continuously accelerated by the out-of-plane reconnection electric field $E_{\rm rec}$ until they become magnetized by the reconnected magnetic field and eventually trapped in plasmoids large enough to confine them. The model also includes diffusive Fermi acceleration by particle bouncing off rapidly moving plasmoids. I argue that the balance between electric acceleration and magnetization controls the power-law index, while trapping in plasmoids governs the cutoff, thus tying the particle energy spectrum to the plasmoid distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CryoTARPOS Vibration Mitigation System for Layered Experiments

The goal of this project is to implement a system that can eliminate or mitigate vibration so that clear images can be taken without bypassing the cryocooler. By allowing for layer characterization and cryocooler operation at the same time, cooling capacity and thermal stability of the target would be improved, and more layer characterization data could be taken. Increased cooling capacity and thermal stability could allow for layering during occasional off normal conditions that would typically result in a loss of temperature control and NIF operational delays ranging from several hours to several days per month. The increased cooling capacity and thermal stability could also allow for layering of new target platforms that have less cooling margin. Additional layer images could be used for better characterization of defects and non-uniformities in the layer and would reduce the likelihood of layer seed loss, which typically adds ~12 hours per week in layering time. Motion blur from vibration due to off normal activity in the NIF Target Bay could also be mitigated that would usually result in NIF operational delays of several hours every month.

42 ENGINEERING↗

Influence of Irradiation-induced Microstructural Defects on Thermal Transport in Single Crystal Thorium Dioxide

Microstructural defects formed as a result of fission fragment damage are known to drastically alter thermal conductivity, a fuel property that governs the efficiency of a nuclear reactor. A fundamental understanding of radiation-induced effects on thermal transport is critical for the development of advanced fuels. Ion-irradiation has widely been used to simulate the effects of neutron-irradiation by seeding atomic-to-nanoscale defects of controllable size and density. In this work, we investigate the influence of microstructural defects, induced by ion-irradiation, on the thermal properties of single crystal thorium dioxide samples grown using the hydrothermal technique. The samples were irradiated using 2 MeV protons at room temperature. A laser-based modulated thermoreflectance technique was used to measure the thermal diffusivity and conductivity within the damaged ThO2 region. The experimentally measured thermal properties were compared with Boltzmann Transport Equation predictions, to determine the impact of various defect types on the thermal properties of ThO2.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Remediating neutron damage in large area planar Ge-DSSD with amorphous germanium contacts through annealing and pulse-height correction

Large area, position sensitive planar germanium detectors offer new opportunities in -ray spectroscopy. For in-beam studies remediating neutron damage is important. This work studied a mechanically cooled circular planar 9 × 1 cm wafer with orthogonal 16 × 16 amorphous germanium strip electrodes. Before neutron irradiation the wafer was heated in-cryostat to above 373 K for more than 24 h in order to test the robustness of the contacts and the mechanical cooler. No deterioration in performance was observed. The detector was then exposed to controlled doses of 2.2 MeV neutrons, produced from the 7 Li(p,n) 7 Be reaction until substantial damage was observed. Averaged over the surface of the wafer, a flux of 1.9(1) x 10 9 n/cm 2 was delivered. The detector then survived thermal cycling and 350 K (~77°C) annealing for 70 h which substantially reduced hole trapping. pulse-height correction is investigated to further mitigate the neutron damage. Higher temperature annealing at 365 K was not successful.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Low Cost SIPM Evaluation and Control Prototyping System including accurate bias voltage generation, leakage current measurement, and temperature control using Peltier cooling

We describe an electronics system to operate SIPMs in the laboratory. The system is comprised of a single channel amplifier board (SIPM Amp) and a 4-channel control board to which up to 4 SIPM Amp boards can be connected. The control board supplies a common low voltage power for the amplifiers. All channels feature individually regulated bias and Peltier power voltages, along withPt10K RTD readout. A graphical user interface allows control of the bias voltages, amplifier voltage, Peltier voltages, and also provides for readback of leakage currents and other voltages. The GUI app has a feedback loop to measure the SIPM temperature (with the PT10K) and generate correction voltages to the Peltier to regulate the temperature. The temperatures, which can be achieved by Peltier cooling depend on the thermal design of the setup, the practical limit being about 50C below ambient. The SIPM Amp. board is a small (3x5cm) PCB that has a single SIPM readout channel. The SIPM scan be surface mounted on the pcb or connected to a 2-pin 0.100" socket. The area around the SIPM footprint is thermally isolated by perforations in the PCB. The RTD is located inside the thermal break. Onboard is BV and LV filtering. The 10X amplifier is based on MiniCircuits' GALI-S66+ integrated circuit, tweaked for a 6V power. The amplifier was selected for a combination of high bandwidth, low noise, and low power. An accoupled amplifier output is connected to an SMA connector. For best operation of this inverting amplifier the output signal should be in the range of 0 to -1V.The Amplifier board is connected to the Control board with a 10-conductor 0.025" pitch ribbon cable, carrying all the services. Peltier power for currents more than 1A should use a separate 2-contact connector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Multiscale Investigation of the Mechanisms Controlling Materials Degradation in the Fusion Energy Environment (DE-SC0006661: Final Report)

Realizing the promise of fusion as a commercially attractive energy source requires the development of advanced structural materials capable of sustained operation in an incredibly hostile environment. The fusion environment presents many challenges associated with high cyclic thermal-mechanical loadings, welding and joining disparate materials, and achieving chemical compatibility with coolants and tritium breeders. Yet, the overarching concern is the degradation of physical and mechanical properties, resulting from a neutron energy spectrum peaked at 14 MeV. The high-energy fusion neutron irradiation produces both displacement damage and high levels of hydrogen and helium through transmutation reactions. Advanced materials development for use in such a hostile environment is predicated on understanding the underlying mechanisms responsible for physical and material property degradation. This project has closely combined computational, theoretical and experimental techniques within a multiscale materials science paradigm to determine the mechanisms controlling material degradation in the fusion environment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intelligent Surrogate Model Development: Boosting Computational Efficiency for Autonomous Control of Advanced Reactors

Advanced reactors promise enhanced safety, greater efficiency, and waste reductions. To fully realize these benefits, it is crucial to address the need for autonomous or semi-autonomous control systems that require fewer operators. This research primarily supports the MARVEL autonomous control system, which requires real-time operation. However, the current RELAP5 reactor thermal hydraulic transient simulation is excessively time-consuming. Therefore, this study aims to leverage deep learning techniques to develop a surrogate model, providing a more efficient and accurate alternative for real-time performance. The model was trained using a combination of one-timestep prediction and scheduled sampling. It was then used for recursive prediction of the reactor state. This developed surrogate model significantly improves computational efficiency, achieving a 12 times acceleration.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

An evaluation of the demand response potential of integrated dynamic window and HVAC systems

Demand response (DR) increases the flexibility and reliability of the electricity grid as use of intermittent renewable energy sources increases. HVAC and envelope DR measures present the largest aggregate energy and peak demand savings potential of all commercial building end uses because their net demand savings occur during critical peak demand periods. Controllable envelope measures include switchable electrochromic windows, operable window attachments such as outdoor louvers, roller shades, and awnings, as well as other innovative facade technologies that can modulate both solar heat gain and daylight admission over a broad solar-optical range. This study evaluated the technical potential of DR-enabled dynamic windows to reduce critical peak demand for a prototypical medium office building situated in all 16 U.S. climates. Model predictive control (MPC) algorithms were designed to minimize electricity cost in daylit perimeter office zones through control of an electrochromic window with and without HVAC thermostat setpoint control. Conventional and time-of-use rates were used to shape the degree of DR. Median annual peak demand savings with window and thermostat control across all climate zones were 24.3 kW (4.4 W/m 2 ) per building or 15.9 W/m 2 for non-north perimeter zones. Resource adequacy at the whole building level was estimated to be 13.1 to 43.4 $/kW per year over the 30-year life of the installation. Co-benefits were increased energy efficiency, and reduced electricity cost and emissions. Visual and thermal comfort requirements were met at all times. Dynamic facades controlled by MPC have substantial technical potential for DR across all U.S. climates and warrant serious consideration for inclusion in DR portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nondestructive Modular Leak Detection in 3D Printed 316L Stainless Steel Pipes via Laser Powder Bed Fusion

This research investigates the leak detection features of 316L Stainless Steel pipe structures manufactured via Laser Powder Bed Fusion (LPBF). This work involves the design of a modular sensor system integrating nondestructive evaluation (NDE) methods, including thermal imaging and ultrasonic frequency detection to detect and characterize leaks in components. This aims to improve leak detection sensitivity within medium-pressure gas systems, during continuous operation without halting flow or introducing safety risks. The system could be adaptable for use on unmanned aerial vehicles (UAVs), enabling remote leak detection in active environments. A custom pneumatic system incorporating temperature and pressure sensors was assembled to detect leaks in LPBF-printed 316L SS tee pipes. Experimental results and simulations confirm the system’s effectiveness in leak detection and material evaluation. This research program also integrated a Python-based image recognition platform based on a metallography and optical microscopy to assess the porosity and complement the leak detection data on the printed structures. This allows a detailed analysis of pore distribution and internal leak paths, which could compromise structural integrity, critical for quality control during manufacturing. Findings suggest that the investigated approach holds potential for enhancing leak detection technologies and adapt them for advanced manufactured parts.

36 MATERIALS SCIENCE↗

Predictive Integrated Modeling of Heated Tokamak Plasmas (Final Technical Report)

The research carried out by the Lehigh University fusion group during this reporting period: (1) Self-consistent predictive core-pedestal ITER scenario modeling; (2) Microtearing instabilities and electron thermal transport in standard and spherical tokamak discharges; (3) Neural network model of the Multi-Mode anomalous transport module; (4) Anomalous transport in KSTAR, JET, EAST, Alcator C-Mod and DIII-D discharges; (5) Theory for transport in magnetized plasmas; (6) Control-oriented modeling of the q-profile dynamic response in preparation for advanced scenario control in KSTAR and in EAST; (7) Modeling of edge harmonic oscillation in DIII-D QH mode discharges; (8) Elucidating plasma dynamics in Hasegawa-Wakatani turbulence by information geometry; (9) Non-linear Langevin and Fractional Fokker–Planck equations for anomalous diffusion by Levy stable processes; and (10) Investigation of the plasma shaping effects on the H-mode pedestal structure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Substituted ALPO-5 Zeolites as Promising O 2 Sorption Pump Materials: A Density Functional Theory Study

Many chemical processes depend on having an environment that is low in oxygen partial pressure (P O2 < 100 Pa); sorption pumps are a promising route to establishing that environment by either oxygen pumping or oxygen separation from an inert gas. Near ambient sorption-based processes rely on either pressure or thermal swings, requiring no moving parts, no electricity, and neither very high nor very low temperatures. In this work, we use ab initio calculations to explore zeolites as a class of materials for sorption based oxygen pumping/separation. Our calculations indicate that while the neat ALPO-5 zeolite does not adsorb O 2 , O 2 does adsorb on zeolites selectively substituted with transition metals and metalloids and hence, can enable separation and pumping. ALPO-5 substituted with Si, Ge, Sn, Pd, Pt, Ti, V, Cr, Mn, Zr, Mo, Hf, W, Ce, and Pr provides adsorption energies ranging from -0.19 to -3.92 eV, (-) indicates exothermic process. Additionally, we provide a comprehensive understanding of what controls the adsorption energy: 1) the substi-tutions must be able to adopt an oxidation state that is more positive than the cation it replaces, and 2) the size of the pore into which the O 2 adsorbs to the wall. Additionally, we conduct a ther-modynamic analysis of a thermal swing cycle to approximate the optimal O 2 binding energy for 2 low energy O 2 pumping/separation. We find that the minimum energy cost likely occurs when the adsorption energy is in the range of 0.75 – 1.00 eV (72 – 97 kJ·mol -1 ), which corresponds to Ge, V, Pt, or Ce substituted ALPO-5.

36 MATERIALS SCIENCE↗

Investigation of modified uni-traveling carrier photodiode for cryogenic microwave photonic links

Quantum devices present the potential for unparalleled computing and communications capabilities; however, the cryogenic temperatures required to successfully control and read out many qubit platforms can prove to be very challenging to scale. Recently, there has emerged an interest in using microwave photonics to deliver control signals down to ultracold stages via optical fiber, thereby reducing thermal load and facilitating dense wavelength multiplexing. Photodetectors can then convert this optical energy to electrical signals for qubit control. The fidelity of the quantum operations of interest therefore depend heavily upon the characteristics of the photodiode, yet experimental demonstrations of fiber-coupled photodetection systems at low temperatures are relatively few in number, leaving important open questions regarding how specific detectors may perform in real-world cryogenic settings. In this work, we examine a highly linear modified uni-traveling carrier photodiode (MUTC-PD) under C-band illumination (1530–1565 nm) at three temperature regimes (300 K, 80 K, and ∼4 K) and multiple bias conditions. Our findings of reduced responsivity but preserved bandwidth are consistent with previous studies, while our saturation tests suggest a variety of potential applications for MUTC-PDs in cryogenic microwave photonics with and without electrical bias. Overall, our results should provide a valuable foundation for the continued and expanding use of this detector technology in quantum information processing.

47 OTHER INSTRUMENTATION↗

Thermal Performance of Neutron Sensor Qualification Device

The neutron sensor qualification device was developed to provide a temperature-controlled environment for neutron sensors and dosimetry, enabling irradiation in a neutron field at the Armed Forces Radiobiology Research Institute (AFRRI) TRIGA reactor facility. The device, constructed from low-activation and low neutron cross-section materials, features a modular tube furnace design with three independently controlled heating zones for controlling axial temperature distribution. Laboratory testing validated the device's thermal performance, including uniform temperature distribution with less than 6°C variation across the central region, a steady-state operational temperature of 350°C achieved in approximately 3 hours, and a cooling time constant of 3.5 hours. External surface temperatures remained safe for handling, with the surrounding aluminum structure remaining at ambient conditions. The results confirm the device’s suitability for neutron sensor qualification experiments, with potential for future operation at higher temperatures and further optimization of performance.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Selective CW Laser Synthesis of MoS2 and Mixture of MoS2 and MoO2 from (NH4)2MoS4 Film

Very recently, the synthesis of 2D MoS2 and WS2 through pulsed laser-directed thermolysis can achieve wafer-scale and large-area structures, in ambient conditions. In this paper, we report the synthesis of MoS2 and MoS2 oxides from (NH4)2MoS4 film using a visible continuous-wave (CW) laser at 532 nm, instead of the infrared pulsed laser for the laser-directed thermolysis. The (NH4)2MoS4 film is prepared by dissolving its crystal powder in DI water, sonicating the solution, and dip-coating onto a glass slide. We observed a laser intensity threshold for the laser synthesis of MoS2, however, it occurred in a narrow laser intensity range. Above that range, a mixture of MoS2 and MoO2 is formed, which can be used for a memristor device, as demonstrated by other research groups. We did not observe a mixture of MoS2 and MoO3 in the laser thermolysis of (NH4)2MoS4. The laser synthesis of MoS2 in a line pattern is also achieved through laser scanning. Due to of the ease of CW beam steering and the fine control of laser intensities, this study can lead toward the CW laser-directed thermolysis of (NH4)2MoS4 film for the fast, non-vacuum, patternable, and wafer-scale synthesis of 2D MoS2.

(NH4)2MoS4↗

High-Temperature Latent Heat Storage System using Transportable Heat Pipes for Versatile Integration with Emerging Microreactors

With the growing interest in the development of micro nuclear reactors and their application to microgrid, high-temperature thermal energy storage (TES) has also been receiving great attention as a technology to reinforce the energy utilization and profitability of this class of reactors. Given the importance and research needs of the TES technology, a research project is underway at Idaho National Laboratory (INL) to develop high-temperature TES that can be easily interfaced with emerging micro nuclear reactors. Currently under development is the Heat pipe-Integrated Thermal Battery (HITB), a novel latent heat storage design that enables flexible and robust integration with any design of currently considered micro nuclear reactors. The development of detailed design based on the proposed TES concept, HITB, requires not only development and validation of modeling and simulation capabilities, but also research that spans thermal performance analysis, component- and system-scale design optimization, and experimental demonstrations including high-temperature feasibility testing. The current research efforts (and plans) are divided into the following four areas: (i) Thermal and structural modeling and analysis at both system- and component-scales for evaluating performance and conducting design optimization, (ii) Small-scale experimental demonstrations for the key components of the proposed HITB design, (iii) Modelica-based dynamic model development for developing a control strategy under dynamic operation within integrated energy systems configuration, (iv) Integrated experimental testing and demonstration. This paper introduces the overall research efforts that have been and are being conducted to develop and demonstrate the novel design of the high-temperature latent heat storage device, HITB. The key design features, ongoing research efforts including the development of modeling and simulation capabilities, small-scale demonstrations of the HITB’s key functionalities prior to scaled-up experimental demonstration, are discussed. Then, this paper concludes with a remark on the future research plans for this project.

25 ENERGY STORAGE↗