Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Constant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Measurement in multiphase reacting flows

A survey is presented of diagnostic techniques and measurements made in multiphase reacting flows. The special problems encountered by the presence of liquid droplets, soot and solid particles in high temperature chemically reacting turbulent environments are outlined. The principal measurement techniques that have been tested in spray flames are spark photography, laser anemometry, thermocouples and suction probes. Spark photography provides measurement of drop size, drop size distribution, drop velocity, and angle of flight. Photographs are analysed automatically by image analysers. Photographic techniques are reliable, inexpensive and proved. Laser anemometers have been developed for simultaneous measurement of velocity and size of individual particles in sprays under conditions of vaporization and combustion. Particle/gas velocity differentials, particle Reynolds numbers, local drag coefficients and direct measurement of vaporization rates can be made by laser anemometry. Gas temperature in sprays is determined by direct in situ measurement of time constants immediately prior to measurement with compensation and signal analysis by micro-processors. Gas concentration is measured by suction probes and gas phase chromatography. Measurements of particle size, particle velocity, gas temperature, and gas concentration made in airblast and pressure atomised liquid spray flames are presented.

Chigier, N. A.↗

Ammonia photolysis and the greenhouse effect in the primordial atmosphere of the earth

Photochemical calculations indicate that in the prebiotic atmosphere of earth ammonia would have been irreversibly converted to N2 in less than 40 years if the ammonia surface mixing ratio were no more than 0.0001. However, if a continuous outgassing of ammonia were maintained, radiative-equilibrium calculations indicate that a surface mixing ratio of ammonia of 0.0001 or greater would provide a sufficient greenhouse effect to keep the surface temperature above freezing. With a 0.0001 mixing ratio of ammonia, 60% to 70% of the present-day solar luminosity would be adequate to maintain surface temperatures above freezing. A lower limit to the time constant for accumulation of an amount of nitrogen equivalent to the present day value is 10 my if the outgassing were such as to provide a continuous surface mixing ratio of ammonia of at least 0.00001.

Kuhn, W. R.↗

A comparison of kinesthetic-tactual and visual displays via a critical tracking task

The feasibility of using the critical tracking task to evaluate kinesthetic-tactual displays was examined. The test subjects were asked to control a first-order unstable system with a continuously decreasing time constant by using either visual or tactual unidimensional displays. The results indicate that the critical tracking task is both a feasible and a reliable methodology for assessing tactual tracking. Further, that the critical tracking methodology is as sensitive and valid a measure of tactual tracking as visual tracking is demonstrated by the approximately equal effects of quickening for the tactual and visual displays.

Jagacinski, R. J.↗

Spatially resolved infrared observations of Saturn. III - 10- and 20-micron disk scans at B prime = -11.8 deg

Disk scans of Saturn at 10 and 20 microns were obtained when the Saturnicentric solar declination B prime was -11.8 deg. The scans show little change from scans obtained when B prime was -16.3 deg. This could result from the long radiative time constant of the Saturnian atmosphere. The observations at 20 microns, in the H2 continuum, show positively that the temperature inversion at the south pole has a higher temperature than at any other point on the disk. In addition, the 12.1- and 20-micron scans indicate that the temperature of the inversion region is higher at the equator compared to the temperate zone. The data also suggest that enhanced 20-micron emission is correlated with the strength of the ultraviolet absorption.

Tokunaga, A. T.↗

Continuous control of phase-locked-loop bandwidth

Tracking loop filter with continuous bandwidth control smooths transition from wide to narrow band. Circuit was designed for Space Shuttle where bandwidth varied between 320 Hz for acquisition and 20 Hz for tracking. Field-effect transitor (FET) acts as voltage controlled variable resistance, changing time constant of filter between phase detector and voltage-controlled oscillator in phase-locked loop.

Motal, G. W.↗

Indoor tests of the concentric-tube solar collector

Report describes performance tests on 12-tube, liquid-filled collector. Thermal efficiency, change in efficiency with sun position, and time constant for temperature drop after solar flux is cut are described.

Source record↗

Evacuated-tube solar collector--performance evaluation

Report gives thermal performance test procedures and results for commercially produced, water-filled, 8-tube collectors. Tests include efficiency, time constant for temperature drop after solar flux is cut, change in efficiency as function of sun angle, and test to see if tubes break when filled with hot water.

Source record↗

Glycol/water evacuated-tube solar collector

Report describes performance of 8 tube and 10 tube commercially produced solar collectors. Tests include thermal efficiency, time constant for temperature drop after solar flux is cut, change in efficiency with Sun angle, and temperature rise if circulation is stopped.

Source record↗

Semiconductor millimeter and centimeter wave radiometer for the study of the radiation of an underlying surface

A theoretical and experimental investigation of a superheterodyne radiometer system with input frequency converter and intermediate frequency modulation is presented. Conditions are found, at which the temperature sensitivity of the device does not deteriorate. A sensitivity function to external parameters (temperature, heterodyne power) of a radiometer system with intermediate frequency modulation and a Schottky diode frequency converter is presented and calculated. Use of a frequency converter at the second harmonic of the heterodyne permitted simplication of the radiometer design and the use of a semiconductor heterodyne. A 3 cm range intermediate frequency amplifier permitted the use of centimeter wave radiometer signals. Fluctuation sensitivity of radiometers with a 1 sec time constant is 0.3 K at 3.4 mm and 0.06 K at 3 cm.

Bordonskiy, G. S.↗

Solid-state switch modeling

A model for predicting voltages and currents of passive loads during turn on and turn off of remote power controllers is presented. The model is concerned with two devices, a five ampere device and a twenty ampere device. The model is presented as a general circuit diagram. The load current is determined by the load parameters and the conditions at switching and the steady state conditions are reached according to time constants determined by the load. The model is used to analyze the turn on and turn off conditions of certain loads including a R-C load and a R-L load.

Raburn, W. D.↗

MPD thruster operation with inductively stored energy

Magnetoplasmadynamic (MPD) thrusters with 10-cm and 2.5-cm long thoriated tungsten cathodes have been operated with both inductive and capacitive energy sources at currents up to 8 kA. Voltage-current characteristics and magnetic field measurements show that over most of the operating range, the inductively driven thruster acts as a continuously varying quasi-steady accelerator at the same current. However, at values of a specified parameter near the onset condition for voltage fluctuations and electrode and insulator erosion, the voltage for the inductively driven thruster is higher than its quasi-steady counterpart. This higher voltage occurs because the equilibration time constant of the MPD discharge, is too large to allow the terminal voltage to attain a quasi-steady value as the inductively driven current decreases.

Clark, K. E.↗

Switching transients in high-frequency high-power converters using power MOSFET's

The use of MOSFETs in a high-frequency high-power dc-to-dc converter is investigated. Consideration is given to the phenomena associated with the paralleling of MOSFETs and to the effect of stray circuit inductances on the converter circuit performance. Analytical relationships between various time constants during the turning-on and turning-off intervals are derived which provide estimates of plateau and peak levels during these intervals.

Sloane, T. H.↗

On the cause of plasma-sheet thinning during magnetospheric substorms

It is proposed that the thinning of the plasma sheet during magnetospheric substorms is caused by an earthward gradient of the rate of magnetic merging (field annihilation) in the tail current sheet, which is in turn caused by the velocity-dependent access of plasma mantle particles to the current sheet. A simple model calculation based on this effect predicts a thinning time constant of the order of 1 hour, consistent with observations. The mechanism is also consistent with the observed correlation between plasma-sheet thinning and southward-directed magnetic field components in the solar wind.

Hill, T. W.↗

A numerical model of the zonal mean circulation of the middle atmosphere

The paper presents a simulation of the zonally averaged circulation in the middle atmosphere using a numerical model based on the primitive equations in log pressure coordinates. The circulation is driven radiatively by heating due to solar ultraviolet absorption by ozone and infrared cooling due to carbon dioxide and ozone; Rayleigh friction with a a short time constant above 70 km is included to simulate the strong mechanical dissipation which is hypothesized to exist in the vicinity of the mesopause due to turbulence associated with gravity waves and tides near the mesopause.

Holton, J. R.↗

Optoacoustic measurement of vibrational-translational /V-T/ rates using a short pulse CO2 laser

A technique for measuring the V-T transfer rates of polyatomic species based on the optoacoustic effect discovered by Bell, Tyndall, and Rontgen (1881) is investigated experimentally. The technique makes use of a coincidental resonance between one of the molecules vibration rotation bands and a CO2 laser line. By this absorption, the molecules can be excited to a known vibrational mode. Since typical time constants for V-T transfer are about 0.00001 sec torr, this method can be used in the pressure region up to 1 torr. The results obtained for CH3F agree with the measurements performed by other techniques.

Lawandy, N. M.↗

Propagation of trans-equatorial deuteron whistlers in the low latitude topside ionosphere

The high latitude limit of transequatorial deuteron whistlers is found to occur at latitudes where B(m) = B/2, in which B is the local magnetic field at the satellite and B(m) is the minimum magnetic field on the field line through the satellite. The high latitude limit of transequatorial proton whistlers, often extends to the latitude where B(m) = B/4 in the autumn and winter. Transequatorial deuteron whistlers have a constant time interval for an echo train. The damping rate of the cyclotron resonant interaction with rare deuteron is large enough to generate deuteron whistlers. Ray tracing results for nonducted propagation of transequatorial deuteron whistlers show that rays are guided by the geomagnetic field within one degree in invariant latitude for several bounces between the two hemispheres.

Watanabe, S.↗

Estimation of Kalman filter model parameters from an ensemble of tests

A methodology for estimating initial mean and covariance parameters in a Kalman filter model from an ensemble of nonidentical tests is presented. In addition, the problem of estimating time constants and process noise levels is addressed. Practical problems such as developing and validating inertial instrument error models from laboratory test data or developing error models of individual phases of a test are generally considered.

Gibbs, B. P.↗

Design data package and operating procedures for MSFC solar simulator test facility

Design and operational data for the solar simulator test facility are reviewed. The primary goal of the facility is to evaluate the performance capacibility and worst case failure modes of collectors, which utilize either air or liquid transport media. The facility simulates environmental parameters such as solar radiation intensity, solar spectrum, collimation, uniformity, and solar attitude. The facility also simulates wind conditions of velocity and direction, solar system conditions imposed on the collector, collector fluid inlet temperature, and geometric factors of collector tilt and azimuth angles. Testing the simulator provides collector efficiency data, collector time constant, incident angle modifier data, and stagnation temperature values.

Source record↗