Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Equatorial wave activity derived from fluctuations in observed convection

The spectrum of equatorial wave activity propagating vertically into the stratosphere is calculated from high-resolution imagery of the global convective pattern. Synoptic Global Cloud Imagery (GCI), constructed from six satellites simultaneously observing the earth, is used to diabatically force the linearized primitive equations. Having resolution of 0.5 deg and 3 h, that imagery captures the dominant scales of organized convection, including several harmonics of the diurnal cycle. Its global coverage with high space-time resolution allows the GCI to represent heating variability and dynamical behavior excited by it over a wide range of scales. The dynamical response above the heating is evaluated globally in terms of a space-time spectrum of Hough modes, one which includes planetary-scale Kelvin waves, Rossby waves, and gravity waves down to the resolution of the GCI. The geopotential response, which is indicative of temperature fluctuations observed by satellite, is very red in frequency. Therefore, planetary-scale waves with periods longer than two days dominate the spectrum of geopotential, while high-frequency gravity waves make a comparatively small contribution. Some 80% of the geopotential variance is accounted for by the Kelvin and gravest-symmetric Rossby modes, while the Rossby-gravity mode is comparatively weak. In horizontal eddy motion, the excited wave spectrum is still dominated by planetary-scale components. However, meridional wind fluctuations associated with the Rossby-gravity mode have variance comparable to that of zonal wind fluctuations associated with the Kelvin mode, even though the Rossby-gravity mode is nearly invisible in the geopotential response. Estimates of tropospheric heating lead to amplitudes and propagation characteristics that are broadly consistent with satellite and radiosonde observations of wave activity in the lower stratosphere. The space-time spectrum of EP flux is significantly whiter than the response in either geopotential or motion. Gravity waves of small scale and high frequency carry a large fraction of the upward flux. Although it dominates eastward variance of geopotential and motion, the Kelvin mode carries only about 50% of the eastward EP flux at phase speeds of 20-40 m/s and only 35% of the total eastward flux transmitted to the stratosphere. The remainder is carried by the gravity wave spectrum, which carries nearly all of the westward flux at phase speeds greater than 20 m/s. The gravity wave spectrum also contributes significantly at phase speeds of 10-20 m/s, where only 25% of the flux is accounted for by zonal wavenumbers less than 20. The broad nature of the gravity wave spectrum suggests its absorption at critical levels will be distributed over a deep layer of the middle atmosphere.

Bergman, John W.↗

Measurements of a LYSO crystal array from threshold to 100 MeV

We report measurements of ten custom-made high-homogeneity LYSO crystals. The investigation is motivated by the need for a compact, high-resolution, and fast electromagnetic calorimeter for a new rare pion decay experiment. Each 2.5 x 2.5 x 18 cm 3 crystal was first characterized for general light yield properties and then its longitudinal response uniformity and energy resolution were measured using low-energy gamma sources. The ten crystals were assembled as an array and subjected to a 30–100 MeV positron beam with excellent momentum definition. The energy and timing resolutions were measured as a function of energy, and the spatial resolution was determined at 70 MeV. An additional measurement using monoenergetic 17.6 MeV gammas produced through a p-Li resonance was later made after the photosensors used in positron testing were improved. Here, as an example of the results, the energy resolution at 70 MeV of (1.52 ± 0.03) % is more than two times better than reported results using previous generation LYSO crystals.

Electromagnetic calorimeter↗

Limits on rapid X-ray pulsing in X-ray binaries

A recent sounding rocket experiment in which the X-ray variations of Cir X-1 and Vela X-1 were investigated at time resolutions down to 1 msecond is described. Sporadic flaring activity in the X-ray sources was observed on time scales from 1 to several seconds, corresponding to intensity changes of about 20% in Cir X-1 and up to 100% in Vela X-1. Periodic, aperiodic, or quasi-periodic pulsations were not detected with time constants less than 1 second. The limits of rapid X-ray pulsations are shown to range from 3 to 15% for Cir X-1, Cyg X-1, Vela X-1, and 3U 1700-37.

Spada, G.↗

Tunable-diode laser absorption spectrometry

Tunable-diode laser absorption spectrometry (TDLAS) affords a number of advantages for atmospheric measurements. It is a universal method, applicable, in principle, to all gases of atmospheric interest. Because of its extremely high spectral resolution it provides unequivocal identification of the target species, with no interferences from other gases. It provides real-time, in situ measurements with time resolutions better than 1 minute. The sensitivity of the current TDLAS system is marginally capable of measuring HO2. This species exists in the troposphere at concentrations which are up to 2 orders of magnitude higher than those of HO and, in addition, is much less susceptible to removal by the surfaces of the instrument and its sampling system. HO2 is an important HO sub x species in its own right but can also give direct information on the HO concentration by virtue of the rapid partitioning between these two species. The addition of the high-frequency modulation technique to the TDLAS system would ensure its ability to measure HO2 under most atmospheric conditions. The ability of the TDLAS to measure hydrogen peroxide (H2O2) in the ambient atmosphere was also demonstrated. H2O2 measurements give a clear indication of HO sub x mixing ratios and are also important as a photolytic source of HO and as an important oxidant for other atmospheric consitituents such as SO2.

Schiff, H. I.↗

Rapid temporal evolution of radiation from non-thermal electrons in solar flares

Solutions of the time dependent Fokker-Planck equation was found for accelerated electrons undergoing Coulomb collisions in a magnetized, fully ionized plasma. An exact solution was found for arbitrary pitch angle and energy distribution in a uniform background plasma. Then, for an inhomogeneous plasma, a solution was found for particles with small pitch angles. These solutions were used to calculate the temporal evolution of bremsstrahlung x-rays from short bursts of nonthermal electron beams, and these spectra were compared with observed high time resolution spectra of short timescale solar hard x-ray bursts. It is shown that the observed softening in time of the spectra rules out a homogeneous background and therefore the possibility of electrons being confined to the corona either because of converging magnetic field or high densities. The inhomogeneous solution was also applied to a model with constant coronal density and exponentially rising chromospheric density. The spectra are shown to be consistent with that produced by a collimated beam of electrons accelerated in the corona with certain given conditions. These conditions could be violated if large pitch angle electrons are present.

Lu, Edward T.↗

Dynamic spectrum of a radio flare on UV Ceti

The dMe flare star UV Ceti (L726-8B) was observed at four frequencies simultaneously in the 1385-1652 MHz band using the Very Large Array. A flare lasting 10 minutes was observed with 6.67 s time resolution 'Dynamic spectrum'-type images in the Stokes parameters I and V show considerable complexity in the frequency-time domain; some features show a positive frequency drift with time, while others are more complex, involving both positive and negative frequency drifts. The positive drift features would be consistent with disturbances traveling downward in the star's corona.

Jackson, Peter D.↗

Rapid temporal evolution of radiation from nonthermal electrons in solar flares

Solutions of the time dependent Fokker-Planck equation was found for accelerated electrons undergoing Coulomb collisions in a magnetized, fully ionized plasma. An exact solution was found for arbitrary pitch angle and energy distribution in a uniform background plasma. Then, for an inhomogeneous plasma, a solution was found for particles with small pitch angles. These solutions were used to calculate the temporal evolution of bremsstrahlung X-rays from short bursts of nonthermal electron beams, and these spectra were compared with observed high time resolution spectra of short timescale solar hard X-ray bursts. It is shown that the observed softening in time of the spectra rules out a homogeneous background and therefore the possibility of electrons being confined to the corona either because of converging magnetic field or high densities. The inhomogeneous solution was also applied to a model with constant coronal density and exponentially rising chromospheric density. The spectra are shown to be consistent with that produced by a collimated beam of electrons accelerated in the corona with certain given conditions. These conditions could be violated if large pitch angle electrons are present.

Lu, Edward T.↗

Air Quality Science and Regulatory Efforts Require Geostationary Satellite Measurements

Air quality scientists and regulatory agencies would benefit from the high spatial and temporal resolution trace gas and aerosol data that could be provided by instruments on a geostationary platform. More detailed time-resolved data from a geostationary platform could be used in tracking regional transport and in evaluating mesoscale air quality model performance in terms of photochemical evolution throughout the day. The diurnal cycle of photochemical pollutants is currently missing from the data provided by the current generation of atmospheric chemistry satellites which provide only one measurement per day. Often peak surface ozone mixing ratios are reached much earlier in the day during major regional pollution episodes than during local episodes due to downward mixing of ozone that had been transported above the boundary layer overnight. The regional air quality models often do not simulate this downward mixing well enough and underestimate surface ozone in regional episodes. Having high time-resolution geostationary data will make it possible to determine the magnitude of this lower-and mid-tropospheric transport that contributes to peak eight-hour average ozone and 24-hour average PM2.5 concentrations. We will show ozone and PM(sub 2.5) episodes from the CMAQ model and suggest ways in which geostationary satellite data would improve air quality forecasting. Current regulatory modeling is typically being performed at 12 km horizontal resolution. State and regional air quality regulators in regions with complex topography and/or land-sea breezes are anxious to move to 4-km or finer resolution simulations. Geostationary data at these or finer resolutions will be useful in evaluating such models.

Pickering, Kenneth E.↗

Stereoscopic Imaging in Hypersonics Boundary Layers using Planar Laser-Induced Fluorescence

Stereoscopic time-resolved visualization of three-dimensional structures in a hypersonic flow has been performed for the first time. Nitric Oxide (NO) was seeded into hypersonic boundary layer flows that were designed to transition from laminar to turbulent. A thick laser sheet illuminated and excited the NO, causing spatially-varying fluorescence. Two cameras in a stereoscopic configuration were used to image the fluorescence. The images were processed in a computer visualization environment to provide stereoscopic image pairs. Two methods were used to display these image pairs: a cross-eyed viewing method which can be viewed by naked eyes, and red/blue anaglyphs, which require viewing through red/blue glasses. The images visualized three-dimensional information that would be lost if conventional planar laser-induced fluorescence imaging had been used. Two model configurations were studied in NASA Langley Research Center's 31-Inch Mach 10 Air Wind tunnel. One model was a 10 degree half-angle wedge containing a small protuberance to force the flow to transition. The other model was a 1/3-scale, truncated Hyper-X forebody model with blowing through a series of holes to force the boundary layer flow to transition to turbulence. In the former case, low flowrates of pure NO seeded and marked the boundary layer fluid. In the latter, a trace concentration of NO was seeded into the injected N2 gas. The three-dimensional visualizations have an effective time resolution of about 500 ns, which is fast enough to freeze this hypersonic flow. The 512x512 resolution of the resulting images is much higher than high-speed laser-sheet scanning systems with similar time response, which typically measure 10-20 planes.

Danehy, Paul M.↗

The 2 Pi Charged Particles Analyzer: All-Sky Camera Concept and Development for Space Missions

Increasing the temporal resolution and instant coverage of velocity space of space plasma measurements is one of the key issues for experimentalists. Today, the top-hat plasma analyzer appears to be the favorite solution due to its relative simplicity and the possibility to extend its application by adding a mass-analysis section and an electrostatic angular scanner. Similarly, great success has been achieved in MMS mission using such multiple top-hat analyzers to achieve unprecedented temporal resolution. An instantaneous angular coverage of charged particles measurements is an alternative approach to pursuing the goal of high time resolution. This was done with 4-D Fast Omnidirectional Nonscanning Energy Mass Analyzer and, to a lesser extent, by DYMIO instruments for Mars-96 and with the Fast Imaging Plasma Spectrometer instrument for MErcury Surface, Space ENvironment, GEochemistry, and Ranging mission. In this paper we describe, along with precursors, a plasma analyzer with a 2 electrostatic mirror that was developed originally for the Phobos-Soil mission with a follow-up in the frame of the BepiColombo mission and is under development for future Russian missions. Different versions of instrument are discussed along with their advantages and drawbacks.

Vaisberg, O.↗

Multiscale Studies of the Three-Dimensional Dayside X-Line

We review recent experience from the Cluster, Double Star, and THEMIS missions for lessons that apply to the upcoming Magnetospheric Multiscale Mission (MMS) being developed for launch in 2014. On global scales, simulation and statistical studies lead to mean congurations of dayside reconnection, implying specific relative alignments of the inflow magnetic fields and X-line, with implications for MMS operations designed to maximize the number of close encounters with the diffusion region. At intermediate MHD-to-ion scales, reconstruction of features created by one or two X-lines have developed to the point where data from a cluster of spacecraft can determine their temporal trends and the approximate three-dimensional X-line structure. Recent petascale particle-in-cell (PIC) simulations of reconnection encompass three spatial dimensions with excellent resolution, and make striking predictions of electron scale physics that creates complex interacting flux ropes under component reconnection. High time resolution measurements from MMS will determine the detailed electron scale kinetics embedded within the global and MHDion scale contexts. These developments will lead to the refinement of our three-dimensional multiscale picture of reconnection, yielding improved understanding of the global, MHD, and local physics controlling the onset or quenching, variability, and mean rate of reconnection. This in turn will enable improved predictability of the structural features created by transient reconnection, and their space weather consequences.

Reconnection↗

Deciphering Photoinduced Catalytic Reaction Mechanisms in Natural and Artificial Photosynthetic Systems on Multiple Temporal and Spatial Scales Using X-ray Probes

Utilization of renewable energies for catalytically generating value-added chemicals is highly desirable in this era of rising energy demands and climate change impacts. Artificial photosynthetic systems or photocatalysts utilize light to convert abundant CO 2 , H 2 O, and O 2 to fuels, such as carbohydrates and hydrogen, thus converting light energy to storable chemical resources. Here, the emergence of intense X-ray pulses from synchrotrons, ultrafast X-ray pulses from X-ray free electron lasers, and table-top laser-driven sources over the past decades opens new frontiers in deciphering photoinduced catalytic reaction mechanisms on the multiple temporal and spatial scales. Operando X-ray spectroscopic methods offer a new set of electronic transitions in probing the oxidation states, coordinating geometry, and spin states of the metal catalytic center and photosensitizers with unprecedented energy and time resolution. Operando X-ray scattering methods enable previously elusive reaction steps to be characterized on different length scales and time scales. The methodological progress and their application examples collected in this review will offer a glimpse into the accomplishments and current state in deciphering reaction mechanisms for both natural and synthetic systems. Looking forward, there are still many challenges and opportunities at the frontier of catalytic research that will require further advancement of the characterization techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two-dimensional correlation analysis for x-ray photoelectron spectroscopy

Abstract X-ray photoelectron spectroscopy (XPS) measures the binding energy of core-level electrons, which are well-localised to specific atomic sites in a molecular system, providing valuable information on the local chemical environment. The technique relies on measuring the photoelectron spectrum upon x-ray photoionisation, and the resolution is often limited by the bandwidth of the ionising x-ray pulse. This is particularly problematic for time-resolved XPS, where the desired time resolution enforces a fundamental lower limit on the bandwidth of the x-ray source. In this work, we report a novel correlation analysis which exploits the correlation between the x-ray and photoelectron spectra to improve the resolution of XPS measurements. We show that with this correlation-based spectral-domain ghost imaging method we can achieve sub-bandwidth resolution in XPS measurements. This analysis method enables XPS for sources with large bandwidth or spectral jitter, previously considered unfeasible for XPS measurements.

47 OTHER INSTRUMENTATION↗

Spatiotemporal characterization of the field-induced insulator-to-metal transition

Watching a metal filament grow Resistive switching is a process in which the electrical resistance of a sample changes abruptly in response to a voltage pulse, often by orders of magnitude. This process is at the heart of many neuromorphic computing approaches but visualizing it in both space and time is tricky. del Valle et al . monitored the resistive switching in three different vanadium oxide compounds by measuring time- and space-resolved optical reflectivity (see the Perspective by Hilgenkamp and Gao). A characteristic conducting filament was quickly nucleated on the inhomogeneities in the sample and then propagated due to Joule heating. —JS

Science & Technology - Other Topics↗

Decoupling of the onset of anharmonicity between a protein and its surface water around 200 K

The protein dynamical transition at ~200 K, where the biomolecule transforms from a harmonic, non-functional form to an anharmonic, functional state, has been thought to be slaved to the thermal activation of dynamics in its surface hydration water. Here, by selectively probing the dynamics of protein and hydration water using elastic neutron scattering and isotopic labeling, we found that the onset of anharmonicity in the two components around 200 K is decoupled. The one in protein is an intrinsic transition, whose characteristic temperature is independent of the instrumental resolution time, but varies with the biomolecular structure and the amount of hydration, while the one of water is merely a resolution effect.

59 BASIC BIOLOGICAL SCIENCES↗

System for locating the sources of wideband dE/dt from lightning

A system has been developed to measure wideband electic field derivatives (dE/dt) at five ground stations in a 15 km x 15 km network at Kennedy Space Center. Individual station responses are normalized using digital filters. Pulse-timing resolution is improved to much less than 50-ns sample interval by interpolation using packing in the frequency domain. A time tag for each pulse is defined as the mean of the times of the rising-edge half peak, peak, and falling-edge half peak. The standard deviation in these times defines the timing error and is shown to be a function of noise and bandwidth rather than digitization rate. Each of the four unknowns for a pulse source location (x,y,z) and time of occurrence (t) is found from the five time-tag measurements using different weightings for all five combinations of the four-station hyperbolic equations. Weighting factors and errors in x,y,z and t are estimated using error propagation techniques.

Thomson, E. M.↗

Studying cataclysmic variables with the Hubble Space Telescope

The Hubble Space Telescope with its UV and imaging capabilities will allow new methods of investigating cataclysmic variables to be used. It provides the first opportunity to obtain high-time-resolution UV observations of cataclysmic variables, both spectroscopically and photometrically. Phase-resolved observations of eclipses can now be obtained which will allow the UV surface-brightness distributions in accretion disks to be studied. Eclipses of white dwarfs that were not visible in optical light will be detected in some systems. Other variations such as dips (in dwarf novae, intermediate polars, and polars), flickering, and oscillations can also be resolved for the first time in the UV. High-spatial-resolution, long-slit spectroscopy, and imaging with the FOC and WF/PC can be used to study the physical condition and morphology of ejected material around novae, recurrent novae, and precataclysmic variables. The UV and H-alpha imaging capabilities will also enable searches for cataclysmic variables in globular clusters to be carried out further into their cores than has been possible before.

Wood, Janet H.↗

Dynamic measurements of thermophysical properties of metals and alloys at high temperatures by subsecond pulse heating techniques

Rapid (subsecond) heating techniques developed at the National Institute of Standards and Technology for the measurements of selected thermophysical and related properties of metals and alloys at high temperatures (above 1000 C) are described. The techniques are based on rapid resistive self-heating of the specimen from room temperature to the desired high temperature in short times and measuring the relevant experimental quantities, such as electrical current through the specimen, voltage across the specimen, specimen temperature, length, etc., with appropriate time resolution. The first technique, referred to as the millisecond-resolution technique, is for measurements on solid metals and alloys in the temperature range 1000 C to the melting temperature of the specimen. It utilizes a heavy battery bank for the energy source, and the total heating time of the specimen is typically in the range of 100-1000 ms. Data are recorded digitally every 0.5 ms with a full-scale resolution of about one part in 8000. The properties that can be measured with this system are as follows: specific heat, enthalpy, thermal expansion, electrical resistivity, normal spectral emissivity, hemispherical total emissivity, temperature and energy of solid-solid phase transformations, and melting temperature (solidus). The second technique, referred to as the microsecond-resolution technique, is for measurements on liquid metals and alloys in the temperature range 1200 to 6000 C. It utilizes a capacitor bank for the energy source, and the total heating time of the specimen is typically in the range 50-500 micro-s. Data are recorded digitally every 0.5 micro-s with a full-scale resolution of about one part in 4000. The properties that can be measured with this system are: melting temperature (solidus and liquidus), heat of fusion, specific heat, enthalpy, and electrical resistivity. The third technique is for measurements of the surface tension of liquid metals and alloys at their melting temperature. It utilizes a modified millisecond-resolution heating system designed for use in a microgravity environment.

Cezairliyan, Ared↗