Search NASA⌕ Search

SEARCH · Search NASA

Results for “Utility Scale Solar Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Optimization of adsorption processes for climate control and thermal energy storage

Adsorption based heat-pumps have received significant interest owing to their promise of higher efficiencies and energy savings when coupled with waste heat and solar energy compared to conventional heating and cooling systems. While adsorption systems have been widely studied through computational analysis and experiments, general design guidelines to enhance their overall performance have not been proposed. In this work, we identified conditions suitable for the maximum utilization of the adsorbent to enhance the performance of both intermittent as well as continuously operating adsorption systems. A detailed computational model was developed based on a general framework governing adsorption dynamics in a single adsorption layer and pellet. We then validated the computational analysis using experiments with a model system of zeolite 13X-water for different operating conditions. A dimensional analysis was subsequently carried out to optimize adsorption performance for any desired operating condition, which is determined by the choice of adsorbent-vapor pair, adsorption duration, operational pressure, intercrystalline porosity, adsorbent crystal size, and intracrystalline vapor diffusivity. The scaling analysis identifies the critical dimensionless parameters and provides a simple guideline to determine the most suitable geometry for the adsorbent particles. Based on this selection criterion, the computational model was used to demonstrate maximum utilization of the adsorbent for any given operational condition. By considering a wide range of parametric variations for performance optimization, these results offer important insights for designing adsorption beds for heating and cooling systems. (C) 2014 Elsevier Ltd. All rights reserved.

Narayanan, S↗

Operating Strategies for Dispatchable PEM Electrolyzers that Enable Low-Cost Hydrogen Production

Hydrogen is a pathway to enabling decarbonization across multiple economic sectors that cannot be directly decarbonized with electricity including heat for industrial operations, medium- and heavy-duty transportation applications, long-duration energy storage, and as a feedstock for chemical synthesis. Producing hydrogen at low costs and carbon footprint is likely essential to economically decarbonize these otherwise "hard to decarbonize" sectors. Low-temperature polymer electrolyte membrane (PEM) electrolysis produces hydrogen from water and electricity and is a rapidly developing pathway towards making hydrogen at the scales required for decarbonization applications. The levelized cost of electrolytic hydrogen is dependent on the capital cost, efficiency, and durability of the electrolyzer system as well as the price of electricity supplied to the electrolyzer and the annual utilization of the electrolyzer (capacity factor). Electricity price and capacity factor depend on the source of energy that the system uses and impact other economic factors. Electricity price and capacity factor and the connections between other aspects of hydrogen production via PEM electrolyzers are the focus of this work. PEM electrolyzers have conventionally been operated at high capacity factors using electricity purchased from utilities with a constant price throughout the year. To achieve lower effective electricity prices, recent work has investigated opportunities for electrolyzers to purchase electricity in wholesale markets, where the cost of electricity varies hourly. This option can lead to lower electricity costs when the electrolyzer is a controllable load that ramps up and down rapidly and turns on and off frequently. This configuration and operating strategy capitalizes on times of low wholesale electricity prices and results in lower hydrogen levelized costs than constant operation due to reduced electricity costs even though the reduced capacity factor increases the cost of recovering the capital investment. Cycling on and off frequently also has implications for electrolyzer durability. An electrolyzer configuration where it is directly connected to renewable generation such as wind or solar, only running when the generator is producing energy, has similar implications on operating strategy, hydrogen levelized cost, capacity factor, and durability. This work provides insight into the relationships between dispatchable electrolyzer operating strategies and the cost of producing hydrogen from these systems, outlining strategies and opportunities to minimize production costs while minimizing operations that are likely to negatively impact system durability and efficiency. We find strategies that minimize electrolyzer cycling and the resulting durability impacts while increasing the hydrogen levelized cost only slightly above the minimum. We also find opportunities for batteries to minimize the number of cycles in systems directly connected to renewable generation. These findings outline key opportunities for future electrolyzer deployments and the synergistic benefits between electrolyzers and increased deployment of renewable energy generation like wind and solar. They also inform research and development that is reducing electrolyzer capital cost while managing durability impacts.

electricity markets↗

A Vision for Co-optimized T&D System Interaction with Renewables and Demand Response

The evolution of the power system to the reliable, effi- cient and sustainable system of the future will involve development of both demand- and supply-side technology and operations. The use of demand response to counterbalance the intermittency of re- newable generation brings the consumer into the spotlight. Though individual consumers are interconnected at the low-voltage distri- bution system, these resources are typically modeled as variables at the transmission network level. In this paper, a vision for co- optimized interaction of distribution systems, or microgrids, with the high-voltage transmission system is described. In this frame- work, microgrids encompass consumers, distributed renewables and storage. The energy management system of the microgrid can also sell (buy) excess (necessary) energy from the transmission system. Preliminary work explores price mechanisms to manage the microgrid and its interactions with the transmission system. Wholesale market operations are addressed through the devel- opment of scalable stochastic optimization methods that provide the ability to co-optimize interactions between the transmission and distribution systems. Modeling challenges of the co-optimization are addressed via solution methods for large-scale stochastic op- timization, including decomposition and stochastic dual dynamic programming.

14 SOLAR ENERGY↗

Mitigation of Dust Impact on Solar Collectors by Water-Free Cleaning With Transparent Electrodynamic Films: Progress and Challenges

Energy-yield loss caused by soiling of photovoltaic modules and concentrated solar power (CSP) mirrors in utility- scale power plants installed in semiarid lands and deserts would result in unsustainable demands for fresh water needed for clean- ing. This paper reviews the progress of the electrodynamic screen (EDS) film technology for frequent water-free cleaning with low- energy requirements. Results presented here, based on laboratory- scale EDS-film-laminated solar panel cleaning, show that the output power can be restored higher than 95% of the initial power under clean conditions. For solar mirrors, the specular reflection efficiency can be maintained over 90% ensuring high efficiency of the CSP plants. Operation of the EDS film for main- taining high optical efficiency of solar collectors requires less than 0.2 Wh/ma 2 /cleaning cycle. Here, principles, optical modeling, construc- tion, lamination of the EDS films on modules and mirrors, and experimental data showing optical efficiency restoration without water consumption are presented. Lastly, current challenges in developing electrodes that would meet optical and conduction properties

14 SOLAR ENERGY↗

Feasibility Study of Large-Scale Energy Storage in the Earth

Energy storage systems on a large scale are needed when there is a mismatch between electricity generation and demand rates. The mismatch may be due to a variety of reasons: 1. Generation rates of solar are cyclic and are often out of phase with the demand cycles. 2. Generation rates of wind are unpredictable. Furthermore, high-efficiency, low-carbon power plants (e.g., nuclear) typically have high capital cost and low operating cost. Such plants are designed for continuous base-load operation and require a high capacity factor for economic viability (Forsberg, 2017). For these reasons, it is advantageous to be able to store energy when not needed and use it when needed. Our proposed process, called the Air Earth Battery, has been developed to accomplish the task of energy storage and dispatch, using a combination of compressors, expanders, heat exchangers, and subsurface porous, permeable rock formations. This technology utilizes two issued U.S. Patents (Buscheck, 2017a; 2017b), one filed U.S. Patent Application (Buscheck, 2017c), and one filed U.S. Provisional Patent Application (Buscheck and Upadhye, 2018).

25 ENERGY STORAGE↗

Queued Up: Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2020

Proposed large-scale electric generation and storage projects must apply for interconnection to the bulk power system via interconnection queues. While many projects that apply for interconnection are not subsequently built, data from these queues nonetheless provide a general indicator for mid-term trends in developer interest. Berkeley Lab compiled and analyzed data from all seven ISOs/RTOs in concert with 35 non-ISO utilities, representing an estimated 85% of all U.S. electricity load. We include all "active" projects in these generation interconnection queues through the end of 2020, as well as data on "completed" and "withdrawn" projects for five of the ISOs (CAISO, ISO-NE, MISO, NYISO, PJM). We find that the total capacity active in the queues is growing year-over-year, with over 750 GW of generation and an estimated 200 GW of storage capacity as of the end of 2020. Solar (462 GW) accounts for a large – and growing – share of generator capacity in the queues. Substantial wind (209 GW) capacity is also in development, 29% of which is for offshore projects (61 GW). In total, about 680 GW of zero-carbon capacity is currently seeking transmission access, as is 74 GW of natural gas capacity. Hybrids now comprise a large – and increasing – share of proposed projects, particularly in CAISO and the non-ISO West. 159 GW of solar hybrids (primarily solar+battery) and 13 GW of wind hybrids are currently active in the queues. However, much of this proposed capacity will not ultimately be built. Among a subset of queues for which data are available, only 24% of the projects seeking connection from 2000 to 2015 have subsequently been built. Completion percentages appear to be declining, and are even lower for wind and solar than other resources. Additionally, wait times are on the rise: in four ISOs, the typical duration from connection request to commercial operation increased from ~1.9 years for projects built in 2000-2009 to ~3.5 years for those built in 2010-2020. There are growing calls for queue reform to reduce cost, lead times, and speculation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Direct Current Arc-Flash Hazards of Solar Photovoltaic Systems

An arc-flash is a rapid release of thermal energy, pressure waves, and electromagnetic interference from a high-power electrical system, caused by such events as unintentional shorting or equipment malfunction. Arc-flashes are hazardous to people and equipment. Incident energy (IE) is a means of quantifying the degree of thermal hazard posed by an arc-flash event. The calculated IE value dictates what level of personal protective equipment (PPE) workers are required to wear when servicing equipment. Overly burdensome PPE may increase a worker’s discomfort and decrease dexterity, which could lead to unintentional shorting, while inadequate PPE also comes with increased safety risks. The majority of arc-flash research to date has focused on alternating current (ac) systems. For example, IE calculations and PPE for ac systems are relatively well understood and have been applied across many equipment types and voltages. IE calculation methodologies in ac systems are backed by a wide range of industry tests and are included in Institute of Electrical and Electronics Engineers (IEEE) and National Fire Protection Association (NFPA) standards. However, very little is known about direct current (dc) arc-flash and its hazards. This is a significant knowledge gap, as an increasing number of dc systems are being deployed: solar photovoltaic (PV) plants, battery storage, and electric vehicles and their charging infrastructure. The dc arc-flash hazard publications are rooted primarily in theory, and their IE calculation methods contradict each other. Insufficient knowledge and data are preventing the formation of industry consensus and standards around dc arc-flash hazard assessment. Here, this white paper highlights the current status and research opportunities for assessing arc-flash hazards in dc systems, with a focus on PV plants. The nonlinear current-voltage characteristics of PV modules make them unique in comparison to other linear dc sources, such as batteries. Also, PV equipment has rapidly evolved from 600 Vdc to 1,500 Vdc (in the United States), increasing potential arc-flash hazards. The operating regime of a PV-array within its I-V characteristic curve during an arc-flash event and the sustainability of arc-flash events in a utility-scale PV plant need to be investigated. Arc-flash experiments on a 1-MWdc nameplate capacity utility-owned ground-mount photovoltaic plant suggest that the PV array acts as a constant-current supply with currents near the short-circuit portion of the I-V characteristic curve of the array, with median arc voltage as 1/3 of the rated voltage. Various engineering software packages (CYME7 by EATON, PTW by SKM, ArcFlash™ by EasyPower, ETAP, and so on) have started offering dc arc-flash calculation features to estimate the risk of arc-flash in dc and PV systems. However, they are reliant on the same simplified arc-flash models, which contradict each other due to differences in assumptions such as characteristics of the power source, arc current, voltage and impedance, arc-operating regime, and so on. Physical arc-flash testing and improved physics-based modeling with correct assumptions representing practical scenarios are two methods to improve understanding and quantify the risks associated with dc arc-flash hazards. The results would inform development of a more accurate calculation procedure for IE and proper PPE levels.

14 SOLAR ENERGY↗

Queued Up: Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2021 [Slides]

Proposed large-scale electric generation and storage projects must apply for interconnection to the bulk power system via interconnection queues. While most projects that apply for interconnection are not subsequently built, data from these queues nonetheless provide a general indicator for mid-term trends in developer interest. Berkeley Lab compiled and analyzed data from all seven ISOs/RTOs in concert with 35 non-ISO utilities, representing an estimated 85% of all U.S. electricity load. We include all "active" projects in these generation interconnection queues through the end of 2021, as well as data on "operational" and "withdrawn" projects where those data are available. We find that the amount of new electric capacity in these queues is growing dramatically, with over 1,400 gigawatts (GW) of total generation and storage capacity now seeking connection to the grid (over 90% of which is for zero-carbon resources like solar, wind, and battery storage). Solar (676 GW) and battery storage (~420 GW) are – by far – the fastest growing resources in the queues; combined they accounted for nearly 85% of new capacity entering the queues in 2021. Substantial wind (247 GW) capacity is also seeking interconnection, 31% of which is for offshore projects (77 GW). In total, about 930 GW of zero-carbon generating capacity is currently seeking transmission access, as is 74 GW of natural gas capacity. Hybrids now comprise a large – and increasing – share of proposed projects, particularly in CAISO and the non-ISO West. 286 GW of solar hybrids (primarily solar+battery) and 19 GW of wind hybrids are currently active in the queues; nearly half of battery storage in the queues is paired with generation. However, much of this proposed capacity will be withdrawn from the queues and not built. Among a subset of queues for which data are available, only 23% of the projects seeking connection from 2000 to 2016 have subsequently been built. Completion percentages appear to be declining and are even lower for wind and solar than other resources. Additionally, wait times are on the rise: for the regions with available data, the typical duration from connection request to commercial operation increased from ~2.1 years for projects built in 2000-2010 to ~3.7 years for those built in 2011-2021.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Queued Up: Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2022 [Slides]

Proposed large-scale electric generation and storage projects must apply for interconnection to the bulk power system via interconnection queues. While most projects that apply for interconnection are not subsequently built, data from these queues nonetheless provide a general indicator for mid-term trends in developer interest. Berkeley Lab compiled and analyzed data from all seven ISOs/RTOs in concert with 35 non-ISO utilities, representing an estimated 85% of all U.S. electricity load. We include all "active" projects in these generation interconnection queues through the end of 2022, as well as data on "operational" and "withdrawn" projects where those data are available. We find that the amount of new electric capacity in these queues is growing dramatically, with over 2,000 gigawatts (GW) of total generation and storage capacity now seeking connection to the grid (over 95% of which is for zero-carbon resources like solar, wind, and battery storage). Solar (947 GW) and battery storage (~680 GW) are – by far – the fastest growing resources in the queues; combined they accounted for over 80% of new capacity entering the queues in 2022. Substantial wind (300 GW) capacity is also seeking interconnection, 38% of which is for offshore projects (113 GW). In total, about 1,250 GW of zero-carbon generating capacity is currently seeking transmission access, as is 82 GW of natural gas capacity. Hybrids projects (co-locating multiple generation and/or storage types) comprise a large – and increasing – share of proposed projects, particularly in CAISO and the non-ISO West. 457 GW of solar hybrids (primarily solar+battery) and 24 GW of wind hybrids are currently active in the queues; over half of battery storage in the queues is paired with generation. However, much of this proposed capacity will be withdrawn from the queues and not built. Among a subset of queues for which data are available, only 21% of the projects (and 14% of capacity) seeking connection from 2000 to 2017 have been built as of the end of 2022. Additionally, interconnection wait times are on the rise: The typical duration from connection request to commercial operation increased from <2 years for projects built in 2000-2007 to nearly 4 years for those built in 2018-2022 (with a median of 5 years for projects built in 2022).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating the Cost Benefits of U.S. Utility-Scale Photovoltaics Plus Energy Storage Systems

Utility-scale photovoltaics (PV) system market growth has been rapid for several years. Today, with the cost reductions of energy storage technologies, the application of combing PV and energy storage has become feasible and beneficial, especially for the areas that only have PV standalone systems and need to shift the peak load to meet the evening electricity demand. Overall, the utility-scale PV plus energy storage systems can provide dispatchable energy and reliable capacity. This study details cost factors, including labor costs, material costs, overhead, and permitting costs using a systemlevel bottom-up cost modeling approach. We use this model to benchmark PV plus storage installation system cost and identify cost difference for AC and DC coupled systems and duration variation. Finally, we assess the cost reduction opportunities of co-locating PV system with energy storage system in order to indicate the possible economic impacts of PV plus storage configuration and help future research and development (R&D) effects in the context of U.S. energy storage policymaking.

14 SOLAR ENERGY↗

Advanced Solar and Load Forecasting Incorporating HD Sky Imaging (Phase III)

Due to rapidly changing sky conditions, the available solar irradiance for energy generation is subject to wide swings in amplitude. As the market penetration of solar energy continues to increase rapidly, these variations in solar power generation are beginning to have an impact on grid stability and increased wear on power switches. Solar power forecasting plays a critical role in operations for Independent System Operators (ISOs) and utilities. Accurate forecasts help maintain grid reliability, optimize generation from renewables, and reduce operating costs. Of particular interest to the ISOs and utilities are sudden changes in solar irradiance, termed “ramp events,” due to the movement of clouds. One significant impact of ramp events on the grid is additional ancillary service requirements necessary to manage such variability. Ramp events can also cause voltage fluctuations in the distribution grids and trigger actions of automated line equipment (e.g., tap changers), leading to additional maintenance costs. In high penetration solar regions, forecasts must be made for both transmission-connected and distribution-connected resources – either behind the meter or in front of it. Particularly for distributed solar energy resources, forecasting can be a challenge due to the lack of visibility of the energy resource. Brookhaven National Laboratory (BNL) has been working towards nowcasting Global Horizontal Irradiance (GHI) using low-cost technologies for several years now. The Solar NowCasting technology being developed by BNL is a 0 – 30 min solar “nowcasting” technology applicable to a scale covering both large generating facilities and residential, distributed solar installations that relies on a network of ground-based high-definition (HD) cameras and surface pyranometers. GHI forecasts are being produced for both regions using 8 ground-based HD cameras and at least 2 surface pyranometers. When stitched together, the camera images can be used to forecast the impact of clouds on available solar irradiance over a domain of ~50 km 2 . Phase I of the project was the engineering scale up conceptual design stage. Phase II was the initial field test and demonstration, in which the technology was scaled up by a factor of 20 times and successfully demonstrated in eastern Long Island. In Phase III, an additional forecasting network was added in upstate NY and both networks are currently being operated until at least a full year of data is gathered by the Albany network to allow for the collection of sufficient data to evaluate performance against the persistence and smart persistence models using the Solar Arbiter.

14 SOLAR ENERGY↗

Using Encapsulated Phase Change Material in Thermal Storage for Baseload Concentrating Solar Power Plants

Terrafore successfully demonstrated and optimized the manufacturing of capsules containing phase-changing inorganic salts. The phase change was used to store thermal energy collected from a concentrating solar-power plant as latent heat. This latent heat, in addition to sensible heat increased the energy density (energy stored per unit weight of salt) by over 50%, thus requiring 40% less salt and over 60% less capsule container. Therefore, the cost to store high-temperature thermal energy collected in a concentrating solar power plant will be reduced by almost 40% or more, as compared to conventional two-tank, sensible-only storage systems. The cost for thermal energy storage (TES) system is expected to achieve the Sun Shot goal of $\$ $15 per kWh(t). Costs associated with poor heat-transfer in phase change materials (PCM) were also eliminated. Although thermal energy storage that relies on the latent heat of fusion of PCM improves energy density by as much as 50%, upon energy discharge the salt freezes and builds on the heat transfer surfaces. Since these salts have low thermal conductivity, large heat-transfer areas, or larger conventional heat-exchangers are needed, which increases costs. By encapsulating PCM in small capsules we have increased the heat transfer area per unit volume of salt and brought the heat transfer fluid in direct contact with the capsules. These two improvements have increased the heat transfer coefficient and boosted heat transfer. The program was successful in overcoming the phenomenon of melt expansion in the capsules, which requires the creation of open volume in the capsules or shell to allow for expansion of the molten salt on melting and is heated above its melting point to 550°C. Under contract with the Department of Energy, Terrafore Inc. and Southwest Research Institute, developed innovative method(s) to economically create the open volume or void in the capsule. One method consists of using a sacrificial polymer coating as the middle layer between the salt prill and the shell material. The selected polymer decomposes at temperatures below the melting point of the salt and forms gases which escape through the pores in the capsule shell thus leaving a void in the capsule. We have demonstrated the process with a commonly used inorganic nitrate salt in a low-cost shell material that can withstand over 10,000 high-temperature thermal cycles, or a thirty-year or greater life in a solar plant. The shell used to encapsulate the salt was demonstrated to be compatible with molten salt heat transfer fluid typically used in CSP plants to temperatures up to 600 °C. The above findings have led to the concept of a cascaded arrangement. Salts with different melting points can be encapsulated using the same recipe and contained in a packed bed by cascading the salt melting at higher melting point at the top over the salt melting at lower melting point towards the bottom of the tank. This cascaded energy storage is required to effectively transfer the sensible heat collected in heat transfer fluids between the operating temperatures and utilize the latent heat of fusion in the salts inside the capsule. Mathematical models indicate that over 90% of the salts will undergo phase change by using three salts in equal proportion. The salts are selected such that the salt at the top of the tank melts at about 15°C below the high operating-temperature, and the salt at the bottom of the tank melts 15°C above the low operating-temperature. The salt in the middle of tank melts in-between the operating temperature of the heat transfer fluid. A cascaded arrangement leads to the capture of 90% of the latent-heat of fusion of salts and their sensible heats. Thus the energy density is increased by over 50% from a sensible-only, two-tank thermal energy storage. Furthermore, the Terrafore cascaded storage method requires only one tank as opposed to the two-tanks used in sensible heat storage. Since heat is transferred from the heat transfer fluid by direct contact with capsules, external heat-exchangers are not required for charging storage. Thus, the cost of the thermal storage system is reduced due to smaller containers and less salt. The optimum salt proportions, their melting temperature and the number of salts in the cascade are determined by raw materials costs and the mathematical model. We estimate the processing cost of the encapsulation to be low, where the major cost of the capsule will be the cost of the phase-change salt(s). Our economic analyses show that the cost of EPCM-TES is about $\$ $17.98 per kWh(t), which is about 40% lower than the $\$ $28.36 per kWh(t) for a two-tank sensible heat TES for a large scale CSP-TES design. Finally, additional improvements in the heat-transfer fluids, currently in development elsewhere will further improve the energy density to achieve the SunShot goal of $\$ $15 per kWh(t).

14 SOLAR ENERGY↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Summary Report of the INL-JISEA Workshop on Nuclear Hybrid Energy Systems

Hybrid energy systems utilize two or more energy resources as inputs to two or more physically coupled subsystems to produce one or more energy commodities as outputs. Nuclear hybrid energy systems can be used to provide load-following electrical power to match diurnal to seasonal-scale changes in power demand or to compensate for the variability of renewable wind or solar generation. To maintain economical, full rate operation of the nuclear reactor, its thermal energy available when power demand is low could be diverted into making synthetic vehicle fuels of various types. The Institute for Nuclear Energy Science and Technology (INEST) and the Joint Institute for Strategic Energy Analysis (JISEA) co-sponsored an international workshop to identify research topics important in advancing the potential use of hybrid systems with a specific focus on nuclear-renewable hybrid systems. The workshop included presentations ranging from energy challenges and research and development (R&D) directions being pursued by nations to multiple options for hybrid systems. Those options include one that is being commercialized to other opportunities and analysis results quantifying them. The workshop also involved two breakout sessions - one focused on thermal energy management issues especially at unit-operation scale and the second focused on system operations issues including system controls, regulatory issues, technical and economic analysis, and market challenges. A discussion involving the full group focused on more general issues such as societal involvement and participation. Key criteria for selecting hybrid energy system projects and metrics for comparing them were also identified by the full group. The workshop's findings are being used initially by INEST to define topics for a research preproposal solicitation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrogen's Expanding Role in the Energy System

Realizing the vision of H2@Scale will require research and investment in efficient hydrogen production methods and upgraded infrastructure. Advances in hydrogen production will allow new applications, such as steelmaking, biofuels production, and fuel cell electric vehicles, to thrive. H2@Scale is a U.S. Dept. of Energy (DOE) initiative that brings together stakeholders to advance affordable hydrogen production, transport, storage, and utilization in multiple energy sectors. H2@Scale will improve the resiliency and reliability of the energy supply chain, increase the competitiveness of U.S. manufacturing, create jobs, and reduce emissions, thereby improving environmental sustainability. Hydrogen has a unique ability to transfer energy across time and economic sectors. The electric grid was designed so that the generated load varies with changes in demand. However, wind and solar power technologies can only generate electricity when each resource is available, making it more difficult to balance the grid. Because hydrogen production can be a large-scale controllable load, it can help address that challenge. Hydrogen can serve as a clean feedstock for diverse applications within the transportation, process industries, and energy sectors. This article describes hydrogen production, application, and infrastructure opportunities. The first part of the article discusses hydrogen production and describes current costs and potential cost reductions that could be enabled by research and development (R&D). The second section discusses key applications that take advantage of hydrogen's chemical properties and its potential as an energy carrier. The final section of the article describes the current hydrogen infrastructure and how it must grow to meet the H2@Scale vision.

08 HYDROGEN↗

Directed-Assembly of Block Copolymers for Large-Scale, Three-Dimensional, Optical Metamaterials at Visible Wavelengths. Final LDRD Report

Metamaterials are composites with patterned subwavelength features where the choice of materials and subwavelength structuring bestows upon the metamaterials unique optical properties not found in nature, thereby enabling optical applications previously considered impossible. However, because the structure of optical metamaterials must be subwavelength, metamaterials operating at visible wavelengths require features on the order of 100 nm or smaller, and such resolution typically requires top-down lithographic fabrication techniques that are not easily scaled to device-relevant areas that are square centimeters in size. In this project, we developed a new fabrication route using block copolymers to make over large device-relevant areas optical metamaterials that operate at visible wavelengths. Our structures are smaller in size (sub-100 nm) and cover a larger area (cm 2 ) than what has been achieved with traditional nanofabrication routes. To guide our experimental efforts, we developed an algorithm to calculate the expected optical properties (specifically the index of refraction) of such metamaterials that predicts that we can achieve surprisingly large changes in optical properties with small changes in metamaterials’ structure. In the course of our work, we also found that the ordered metal nanowires meshes produced by our scalable fabrication route for making optical metamaterials may also possibly act as transparent electrodes, which are needed in electrical displays and solar cells. We explored the ordered metal nanowires meshes’ utility for this application and developed design guidelines to aide our experimental efforts.

36 MATERIALS SCIENCE↗

2018 U.S. Utility-Scale Photovoltaics-Plus-Energy Storage System Costs Benchmark

Market growth for utility-scale photovoltaic (PV) systems has been rapid for several years. Today, with the cost reductions of energy storage technologies, the combining PV and energy storage has become feasible and beneficial, especially for the areas that have only PV standalone systems and need to shift the peak load to meet electricity demand in the evening. Overall, utility-scale PV plus energy storage systems can provide dispatchable energy and reliable capacity. This study details cost factors, including labor costs, material costs, overhead, and permitting costs using a system-level bottom-up cost modeling approach. We use this model to benchmark PV-plus-storage installation system cost and identify the cost difference for AC- and DC-coupled systems and duration variation. Finally, we assess the cost reduction opportunities of colocating PV systems with energy storage systems in order to indicate the possible economic impacts of the PV-plus-storage configuration and help future research and development (R&D) effects in the context of U.S. energy storage policymaking.

14 SOLAR ENERGY↗

2018 U.S. Utility-Scale Photovoltaics-Plus-Energy Storage System Costs Benchmark

Market growth for utility-scale photovoltaic (PV) systems has been rapid for several years. Today, with the cost reductions of energy storage technologies, the combining PV and energy storage has become feasible and beneficial, especially for the areas that have only PV standalone systems and need to shift the peak load to meet electricity demand in the evening. Overall, utility-scale PV plus energy storage systems can provide dispatchable energy and reliable capacity. This study details cost factors, including labor costs, material costs, overhead, and permitting costs using a system-level bottom-up cost modeling approach. We use this model to benchmark PV-plus-storage installation system cost and identify the cost difference for AC- and DC-coupled systems and duration variation. Finally, we assess the cost reduction opportunities of colocating PV systems with energy storage systems in order to indicate the possible economic impacts of the PV-plus-storage configuration and help future research and development (R&D) effects in the context of U.S. energy storage policymaking.

14 SOLAR ENERGY↗