Mechanization of and experience with a triplex fly-by-wire backup control system

A redundant three-axis analog control system was designed and developed to back up a digital fly-by-wire control system for an F-8C airplane. Forty-two flights, involving 58 hours of flight time, were flown by six pilots. The mechanization and operational experience with the backup control system, the problems involved in synchronizing it with the primary system, and the reliability of the system are discussed. The backup control system was dissimilar to the primary system, and it provided satisfactory handling through the flight envelope evaluated. Limited flight tests of a variety of control tasks showed that control was also satisfactory when the backup control system was controlled by a minimum-displacement (force) side stick. The operational reliability of the F-8 digital fly-by-wire control system was satisfactory, with no unintentional downmodes to the backup control system in flight. The ground and flight reliability of the system's components is discussed.

Lock, W. P.↗

Lightning effects on the NASA F-8 digital-fly-by-wire airplane

The effects of lightning on a Digital Fly-By-Wire (DFBW)aircraft control system were investigated. The aircraft was a NASA operated F-8 fitted with a modified Apollo guidance computer. Current pulses similar in waveshape to natural lightning, but lower in amplitude, were injected into the aircraft. Measurements were made of the voltages induced on the DFBW circuits, the total current induced on the bundles of wires, the magnetic field intensity inside the aircraft, and the current density on the skin of the aircraft. Voltage measurements were made in both the line-to-ground and line-to-line modes. Voltages measured at the non-destructive test level were then scaled upward to determine how much would be produced by actual lightning. A 200,000 ampere severe lightning flash would produce between 40 and 2000 volts in DFBW circuits. Some system components are expected to be vulnerable to these voltages.

Plumer, J. A.↗

F-8 digital fly-by-wire flight test results viewed from an active controls perspective

The results of the NASA F-8 digital fly-by-wire flight test program are presented, along with the implications for active controls applications. The closed loop performance of the digital control system agreed well with the sampled-data system design predictions. The digital fly-by-wire mechanization also met pilot flying qualities requirements. The advantages of mechanizing the control laws in software became apparent during the flight program and were realized without sacrificing overall system reliability. This required strict software management. The F-8 flight test results are shown to be encouraging in light of the requirements that must be met by control systems for flight-critical active controls applications.

Zalai, K. J.↗

Preliminary system design study for a digital fly-by-wire flight control system for an F-8C aircraft

The design of a fly-by-wire control system having a mission failure probability of less than one millionth failures per flight hour is examined. Emphasis was placed on developing actuator configurations that would improve the system performance, and consideration of the practical aspects of sensor/computer and computer/actuator interface implementation. Five basic configurations were defined as appropriate candidates for the F-8C research aircraft. Options on the basic configurations were included to cover variations in flight sensors, redundancy levels, data transmission techniques, processor input/output methods, and servo actuator arrangements. The study results can be applied to fly by wire systems for transport aircraft in general and the space shuttle.

Seacord, C. L.↗

Mechanization of and experience with a triplex fly-by-wire backup control system

A redundant three axis analog control system was designed and developed to back up a digital fly by wire control system for an F-8C airplane. The mechanization and operational experience with the backup control system, the problems involved in synchronizing it with the primary system, and the reliability of the system are discussed. The backup control system was dissimilar to the primary system, and it provided satisfactory handling through the flight envelope evaluated. Limited flight tests of a variety of control tasks showed that control was also satisfactory when the backup control system was controlled by a minimum displacement (force) side stick. The operational reliability of the F-8 digital fly by wire control system was satisfactory, with no unintentional downmodes to the backup control system in flight. The ground and flight reliability of the system's components is discussed.

Lock, W. P.↗

Use of miniature, single-wire, sheathed thermocouples

Temperature measurement with small thermocouples is improved by device. Each wire is sheathed separately which increases the interelement insulation by factor of 2 1/2. Each wire in its separate sheath can be brought to junction by independent paths.

Glawe, G. E.↗

Automated inspection of wire-frame assemblies

System improves accuracy of measurement between spaces of wire mesh and other wire frame assemblies while significantly reducing inspection time. Device operates automatically producing printout of measured spacings through use of optical scanner.

Etzel, J. G.↗

Voltages and currents induced on wiring

Aircraft lightning strikes were investigated in regard to their effects on voltages and currents in aircraft wiring. An electrical conductor's response to magnetic fields and electric fields was examined as part of the voltage and current calculations. The wiring system of the space shuttle was briefly considered as an example.

Franklin A Fisher↗

Buried wire gage for wall shear stress measurements

A buried wire gage for measuring wall shear stress in fluid flow was studied and further developed. Several methods of making this relatively new type of gage were examined to arrive at a successful technique that is well-suited for wind-tunnel testing. A series of measurements was made to demonstrate the adequacy of a two-point calibration procedure for these gages. The buried wire gage is also demonstrated to be ideally suited for quantitative measurement of wall shear stress in wind-tunnel testing.

Murthy, V. S.↗

A hybrid technique for wire antennas in a cavity

An evaluation is conducted of two numerical techniques developed by Richmond (1961, 1966) for wire antennas and scattering bodies. It is concluded that a more efficient and accurate scheme can be devised by suitably combining the two techniques. This scheme, which is called the 'hybrid method', is well suited for a wire antenna mounted in a cavity. Reaction matching is employed in the case of the antenna, while point matching is used for the support structure. The described approach makes it possible to consider voltage generators without the use of any equivalent magnetic frill current sources. The number of unknown currents to be determined is essentially optimized by this combination of reaction matching and point matching. The resulting current distribution is a quantized distribution on the support structure and is continuous on the main radiator.

Agrawal, P. K.↗

Hot-wire, laser anemometer and force balance measurements of cross-sectional planes of single and interacting trailing vortices

Single and multiple trailing vortices shed from semi-span wings and a transport model in a wind tunnel were studied by means of a laser-velocimeter, hot-wire anemometer, and a trailing model incorporating a 6-component force balance. Velocity profile and turbulence data from the laser-velocimeter and hot-wire anemometer are presented and shown to compare well with the Betz inviscid circulation model. Lift and rolling moment measurements on the following model are compared with those predicted from the flow field measurements.

Iversen, J. D.↗

On the measurement of turbulent fluctuations in high-speed flows using hot wires and hot films

A hot wire has a limited life in high speed wind-tunnel flows because it is typically subjected to large dynamic loads. As a consequence hot films and modified hot wires are frequently used for turbulence measurements in such flows. However, the fluctuation sensitivities of such probes are reduced because of various factors, leading to erroneous results. This paper describes the results of tests on some sensors in both subsonic and supersonic boundary-layer flows. A simple technique to determine dynamic calibration correction factors for the sensitivities is also presented.

Acharya, M.↗

Steady-state analysis of a faulted three-phase four-wire system supplying induction motors with neutrals connected and other single-phase line-to-neutral loads

Four wire Wye connected ac power systems exhibit peculiar steady state fault characteristics when the fourth wire of three phase induction motors is connected. The loss of one phase of power source due to a series or shunt fault results in currents higher than anticipated on the remaining two phases. A theoretical approach to compute the fault currents and voltages is developed. A FORTRAN program is included in the appendix.

Wood, M. E.↗

Wall proximity corrections for hot-wire readings in turbulent flows

This note describes some details of recent (successful) attempts of wall proximity corrections for hot-wire measurements performed in a three-dimensional incompressible turbulent boundary layer. A simple and quite satisfactory method of estimating wall proximity effects on hot-wire readings is suggested.

Hebbar, K. S.↗

Add-On Shielding for Unshielded Wire

Fabrication sequence used to produce compact shields slipped into place from free ends of wires already soldered into connectors at other ends. Single shields are formed into harnesses by connecting grounding jumpers. Technique is especially useful for small diameter wire attached to microminiature connectors.

Koenig, J. C.↗

Wire Electrical-Discharge Machining Aid

Rerouting cutting wire by adding idler rollers allows standard wire electrical-discharge machine (WEDM) temporarily modified to permit some types of cuts otherwise blocked.

Gollihugh, T.↗