Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Concept, implementation and commissioning of the automation system for the accelerator module test facility AMTF

The European XFEL project launched on June 5, 2007 will require about 103 accelerator modules as a main part of the XFEL linear accelerator. All superconducting components constituting the accelerator module like cavities and magnets have to be tested before the assembly. For the tests of the individual cavities and the complete modules an XFEL Accelerator Module Test Facility (AMTF) has been erected at DESY. The process control system EPICS (Experimental Physics and Industrial Control System) is used to control and operate the cryogenic plant and all its subcomponents. A complementary component of EPICS is the Open Source software suit CSS (Control System Studio). CSS is an integrated engineering, maintenance and operating tool for EPICS. CSS enables local and remote operating and monitoring of the complete system and thus represents the human machine interface. More than 250 PROFIBUS nodes work at the accelerator module test facility. DESY installed an extensive diagnostic and condition monitoring system. With these diagnostic tools it is possible to examine the correct installation and configuration of all PROFIBUS nodes in real time. The condition monitoring system based on FDT/DTM technology shows the state of the PROFIBUS devices at a glance. This information can be used for preventive maintenance which is mandatory for continuous operation of the AMTF facility. The poster will describe all steps form engineering to implementation and commissioning.

43 PARTICLE ACCELERATORS↗

NuMI proton beam diagnostics and control: achieving 2 megawatt capability

The NuMI proton beam at Fermilab currently delivers 120 GeV protons to the neutrino production target with design beam power capability to 400 kW. Upgrade capability to 700 kW is being prepared, with planning toward delivering 2.3 MW beam provided by the Project X accelerator upgrade plan. We report on the system of beam diagnostics and control used in operation of the NuMI beam. Also considered are the steps to provide a robust system for transport and targeting beam of 2 MW and beyond.

43 PARTICLE ACCELERATORS↗

In vivo measurement of bone aluminum in population living in southern Ontario, Canada

The harmful biological effect of excessive aluminum (Al) load in humans has been well documented in the literature. Al stored in bone, for instance due to dialysis treatment or occupational exposure, can interfere with normal bone remodeling leading to osteodystrophy, osteoarthritis, or osteomalacia. On the other hand, the relationship between chronic Al exposure and the risk of Alzheimer's disease remains controversial. In this work, the feasibility of in vivo neutron activation analysis (IVNAA) for measuring Al levels in the human hand bone, using the thermal neutron capture reaction {sup 27}Al(n,{gamma}){sup 28}Al, is reported. This noninvasive diagnostic technique employs a high beam current Tandetron accelerator based neutron source, an irradiation/shielding cavity, a 4{pi} NaI(Tl) detector system, and a new set of hand bone phantoms. The photon spectra of the irradiated phantom closely resemble those collected from the hands of nonexposed healthy subjects. A protocol was developed using the newly developed hand phantoms, which resulted in a minimum detectable limit (MDL) of 0.29 mg Al in the human hand. Using the ratio of Al to Ca as an index of Al levels per unit bone mass, the MDL was determined as 19.5{+-}1.5 {mu}g Al/g Ca, which is within the range of the measured levels of 20-27 {mu}g Al/g Ca[ICRP, Report of the Task Group on Reference Man, Publication 23 (Pergamon, Oxford, 1975)] found in other in vivo and in vitro studies. Following the feasibility studies conducted with phantoms, the diagnostic technique was used to measure Al levels in the hand bones of 20 healthy human subjects. The mean hand bone Al concentration was determined as 27.1{+-}16.1 ({+-}1 SD) {mu}g Al/g Ca. The average standard error (1{sigma}) in the Al/Ca is 14.0 {mu}g Al/g Ca, which corresponds to an average relative error of 50% in the measured levels of Al/Ca. These results were achieved with a dose equivalent of 17.6 mSv to a hand and an effective dose of 14.4 {mu}Sv. This effective dose is approximately half of that received in a chest radiograph examination. It is recommended to investigate the use of the bone Al IVNAA diagnostic technique for in vivo measurements of patients with documented overload of Al in bone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cyclotron Requirements for Multi-disciplinary Programs

As time has passed, the various Cyclotron programs have changed over the years. In the ''early'' times of Cyclotron operations, the emphasis was on a more single sided approach such as Clinical or Research or Production. However, as time passed, the disciplines became more interconnected until today, it is unusual to have a Cyclotron and only have a single program unless it is pure production. More and more, especially in public areas such as Universities or Health Centers, you are seeing programs that do all three types of disciplines: Production; Clinical or Patient Diagnostics and/or Treatment; and Research, either in the development and manufacture of new Radio-Isotopes, new Diagnostic or Therapeutic Compound Development, or Clinical Research involving subject testing. While all three of these disciplines have some common requirements, they also have some very different requirements that may be completely counterproductive to other requirements. For a program where all three disciplines are required to be successful, it is necessary come up with some sort of compromise that meets all the various requirements. During this talk, we will try to identify some of these different requirements for the various disciplines and how these could impact the other disciplines. We will also discuss ideas for some possible compromises that might reduce the conflict between the various disciplines.

43 PARTICLE ACCELERATORS↗

TEXES OBSERVATIONS OF M SUPERGIANTS: DYNAMICS AND THERMODYNAMICS OF WIND ACCELERATION

We have detected [Fe II] 17.94 {mu}m and 24.52 {mu}m emission from a sample of M supergiants ({mu} Cep, {alpha} Sco, {alpha} Ori, CE Tau, AD Per, and {alpha} Her) using the Texas Echelon Cross Echelle Spectrograph on NASA's Infrared Telescope Facility. These low opacity emission lines are resolved at R {approx_equal} 50, 000 and provide new diagnostics of the dynamics and thermodynamics of the stellar wind acceleration zone. The [Fe II] lines, from the first excited term (a {sup 4} F), are sensitive to the warm plasma where energy is deposited into the extended atmosphere to form the chromosphere and wind outflow. These diagnostics complement previous Kuiper Airborne Observatory and Infrared Space Observatory observations which were sensitive to the cooler and more extended circumstellar envelopes. The turbulent velocities of V{sub turb} {approx_equal} 12-13 km s{sup -1} observed in the [Fe II] a {sup 4} F forbidden lines are found to be a common property of our sample, and are less than that derived from the hotter chromospheric C II] 2325 A lines observed in {alpha} Ori, where V{sub turb} {approx_equal} 17-19 km s{sup -1}. For the first time, we have dynamically resolved the motions of the dominant cool atmospheric component discovered in {alpha} Ori from multiwavelength radio interferometry by Lim et al. Surprisingly, the emission centroids are quite Gaussian and at rest with respect to the M supergiants. These constraints combined with model calculations of the infrared emission line fluxes for {alpha} Ori imply that the warm material has a low outflow velocity and is located close to the star. We have also detected narrow [Fe I] 24.04 {mu}m emission that confirms Fe II is the dominant ionization state in {alpha} Ori's extended atmosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

Very low frequency waves stimulated by an electron accelerator in the auroral ionosphere

The sounding rocket, Polar 5, carrying a 10 keV electron accelerator in a mother-daughter configuration and other diagnostic instruments, was launched into a slightly disturbed ionosphere with weak auroral activity on February 1, 1976 from Northern Norway to study VLF wave phenomena. The rocket trajectory crossed two auroral regions: one, between 86 and 111 s flight time, and a secondary region between 230 and 330 s. The daughter, carrying the accelerator, was separated axially from the mother in a forward direction at an altitude of 90 km. The VLF experiment, carried by the mother payload, recorded both electromagnetic and electrostatic waves. The receiving antenna was an electric dipole, 0.3 m tip-to-tip, oriented 90 degrees to the rocket spin axis. The onboard particle detector recorded increased electron fluxes in the two auroral regions. A double peaked structure was observed in the fluxes of 4-5 and 12-27 keV electrons within the northern auroral form. The number density of thermal plasma varied during the flight, with maximum density within the main auroral region. To the north of this aurora a slow, steady decrease in the density was observed, with no enhancement in the region of the second aurora.

Holtet, J. A.↗

Diagnostic and Power Feed Upgrades to the MAIZE Facility

The Michigan Accelerator for Inductive Z-pinch experiments (MAIZE) is a one stage, 1 MA, Linear Transformer Driver (LTD) at the University of Michigan. The MAIZE facility has been the site of various experimental studies, including wire array z-pinches for x-ray source development and cylindrical foil loads for implosion stability analysis. Here, in order to better understand and investigate these and other experiments, a 4- frame extreme ultraviolet (EUV) camera was implemented, the optical stability of a 12-frame laser shadowgraphy system was improved, B-dot probes were upgraded, and a Rogowski coil was constructed. New conical load hardware was also developed to reduce the inductance of the transmission line and thus improve the current delivered to the loads.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physics of the inner heliosphere 1-10R sub O plasma diagnostics and models

The physics of solar wind flow in the acceleration region and impulsive phenomena in the solar corona is studied. The study of magnetohydrodynamic wave propagation in the corona and the solutions for steady state and time dependent solar wind equations gives insights concerning the physics of the solar wind acceleration region, plasma heating and plasma acceleration processes and the formation of shocks. Also studied is the development of techniques for placing constraints on the mechanisms responsible for coronal heating.

Withbroe, G. L.↗

Summary Report on Beam and Radiation Generation, Monitoring and Control

The discussions of the working group on beam and radiation generation, monitoring, and control (working group 6) at the 2008 advanced accelerator concepts workshop are summarized. The discussions concerned electron injectors, phase space manipulation, beam diagnostics, pulse train generation, intense beam physics, and radiation generation.

43 PARTICLE ACCELERATORS↗

A study of sacrificial mirrors for use prior to a laser wakefield accelerator driven by the Z-Petawatt laser

Many experiments at Sandia’s Z Pulsed Power Facility require x-ray backlighting diagnostics to understand experiment performance. Due to limitations in present-day source/detection modalities, most x-ray diagnostics at Z are restricted to photon energies <20 keV, ultimately limiting the density, amount, and atomic number of targets diagnosable in experiments. These limitations force the use of low-Z materials like Beryllium, and they prevent acquisition of important backlighting data for materials/densities that are opaque to soft x-rays and where background emission from the Z load and transmission lines overwhelm diagnostics. In this LDRD project, we have investigated the design and development of a laser wakefield acceleration platform driven by the Z-Petawatt laser – a platform that would enable the generation of a pulsed, collimated beam of high energy x-rays up to 100 keV. Geometrical considerations for implementation on the Z Machine require the use of sacrificial mirrors, which have been tested in offline experiments in the Chama target chamber in building 983. Our results suggest the use of sacrificial mirrors would not necessarily inhibit the laser wakefield x-ray process, particularly with the benefits stemming from planned laser upgrades. These conclusions support the continuation of laser wakefield source research and the development of the necessary infrastructure to deliver the Z-Petawatt laser to the Z center section along the appropriate lines of sight. Ultimately, this new capability will provide unprecedented views through dense states of matter, enabling the use of previously incompatible target materials/designs, and uncovering a new set of observables accessible through diffraction and spectroscopy in the hard x-ray regime. These will amplify the data return on precious Z shots and enhance Sandia’s ability to investigate fundamental physics in support of national security.

43 PARTICLE ACCELERATORS↗

Microdose-Induced Drug–DNA Adducts as Biomarkers of Chemotherapy Resistance in Humans and Mice

Here, we report progress on predicting tumor response to platinum-based chemotherapy with a novel mass spectrometry approach. Fourteen bladder cancer patients were administered one diagnostic microdose each of [ 14 C]carboplatin (1% of the therapeutic dose). Carboplatin–DNA adducts were quantified by accelerator mass spectrometry in blood and tumor samples collected within 24 hours, and compared with subsequent chemotherapy response. Patients with the highest adduct levels were responders, but not all responders had high adduct levels. Four patient-derived bladder cancer xenograft mouse models were used to test the possibility that another drug in the regimen could cause a response. The mice were dosed with [ 14 C]carboplatin or [ 14 C]gemcitabine and the resulting drug–DNA adduct levels were compared with tumor response to chemotherapy. At least one of the drugs had to induce high drug–DNA adduct levels or create a synergistic increase in overall adducts to prompt a corresponding therapeutic response, demonstrating proof-of-principle for drug–DNA adducts as predictive biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗

The Accelerator and Beam Physics of the Muon g-2 Experiment at Fermilab

The physics case of the Muon g-2 Experiment at Fermilab is outstanding and has recently attracted significant attention from its first official results. Although its measurements involve high energy physics methods, such as counting positron production rates with the use of calorimeters and beam diagnostics with tracking detectors, this experiment is strongly bound to accelerator and beam physics. This paper reviews the principles of the experiment and the details necessary to provide a solid ground for the beam-dynamics uncertainties and the corrections of the systematic effects influencing the output of the experiment: a single numerical value, which may unveil new physics.

43 PARTICLE ACCELERATORS↗

Helical Tomotherapy-Based STAT RT: Dosimetric Evaluation for Clinical Implementation of a Rapid Radiation Palliation Program

Helical tomotherapy-based STAT radiation therapy (RT) uses an efficient software algorithm for rapid intensity-modulated treatment planning, enabling conformal radiation treatment plans to be generated on megavoltage computed tomography (MVCT) scans for CT simulation, treatment planning, and treatment delivery in one session. We compared helical tomotherapy-based STAT RT dosimetry with standard linac-based 3D conformal plans and standard helical tomotherapy-based intensity-modulated radiation therapy (IMRT) dosimetry for palliative treatments of whole brain, a central obstructive lung mass, multilevel spine disease, and a hip metastasis. Specifically, we compared the conformality, homogeneity, and dose with regional organs at risk (OARs) for each plan as an initial step in the clinical implementation of a STAT RT rapid radiation palliation program. Hypothetical planning target volumes (PTVs) were contoured on an anthropomorphic phantom in the lung, spine, brain, and hip. Treatment plans were created using three planning techniques: 3D conformal on Pinnacle{sup 3}, helical tomotherapy, and helical tomotherapy-based STAT RT. Plan homogeneity, conformality, and dose to OARs were analyzed and compared. STAT RT and tomotherapy improved conformality indices for spine and lung plans (CI spine = 1.21, 1.17; CI lung = 1.20, 1.07, respectively) in comparison with standard palliative anteroposterior/posteroanterior (AP/PA) treatment plans (CI spine = 7.01, CI lung = 7.30), with better sparing of heart, esophagus, and spinal cord. For palliative whole-brain radiotherapy, STAT RT and tomotherapy reduced maximum and mean doses to the orbits and lens (maximum/mean lens dose: STAT RT = 2.94/2.65 Gy, tomotherapy = 3.13/2.80 Gy, Lateral opposed fields = 7.02/3.65 Gy), with an increased dose to the scalp (mean scalp dose: STAT RT = 16.19 Gy, tomotherapy = 15.61 Gy, lateral opposed fields = 14.01 Gy). For bony metastatic hip lesions, conformality with both tomotherapy techniques (CI = 1.01 each) is superior to AP/PA treatments (CI = 1.21), as expected. Helical tomotherapy-based STAT RT treatment planning provides clinically acceptable dosimetry, with conformality and homogeneity that is superior to standard linac-based 3D conformal planning and is only slightly inferior to standard helical tomotherapy IMRT dosimetry. STAT RT facilitates rapid treatment planning and delivery for palliative radiation of patients with metastatic disease, with relative sparing of adjacent OARs compared with standard 3D conformal plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

The High Energy Materials Science Beamline (HEMS) at PETRA III

The HEMS Beamline at the German high-brilliance synchrotron radiation storage ring PETRA III is fully tunable between 30 and 250 keV and optimized for sub-micrometer focusing. Approximately 70 % of the beamtime will be dedicated to Materials Research. Fundamental research will encompass metallurgy, physics and chemistry with first experiments planned for the investigation of the relationship between macroscopic and micro-structural properties of polycrystalline materials, grain-grain-interactions, and the development of smart materials or processes. For this purpose a 3D-microsctructure-mapper has been designed. Applied research for manufacturing process optimization will benefit from high flux in combination with ultra-fast detector systems allowing complex and highly dynamic in-situ studies of micro-structural transformations, e.g. during welding processes. The beamline infrastructure allows accommodation of large and heavy user provided equipment. Experiments targeting the industrial user community will be based on well established techniques with standardized evaluation, allowing full service measurements, e.g. for tomography and texture determination. The beamline consists of a five meter in-vacuum undulator, a general optics hutch, an in-house test facility and three independent experimental hutches working alternately, plus additional set-up and storage space for long-term experiments. HEMS is under commissioning as one of the first beamlines running at PETRA III.

43 PARTICLE ACCELERATORS↗

Plasma dynamics in laboratory-produced current sheets

Evolution of currents and Ampere forces in current sheets are analyzed on the basis of magnetic measurements. Two new effects are observed in the current distributions at the later stage of the sheet evolution: first, a broadening of the current area at the side edges of the current sheet; second, a generation of reverse currents followed by their propagation from the edges to the center of the sheet. Super-thermal plasma flows moving across the width of the current sheet are observed by spectroscopic methods. The energies of plasma jets are consistent with the spatial structure and time dependences of the Ampere forces in the current sheets. The assumption is advanced that plasma acceleration may be more effective at the regions with lower plasma density, which are located at some distances from the sheet mid-plane. Generation of reverse currents provides an additional confirmation of transfer of energetic plasma jets toward the sheet edges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active spectroscopy measurements of the deuterium temperature, rotation, and density from the core to scrape off layer on the DIII-D tokamak (invited)

Main-ion charge exchange recombination spectroscopy (MICER) uses the neutral beam induced D α spectrum to measure the local deuterium ion ( D + ) temperature, rotation, and density, as well as parameters related to the neutral beams, fast ions, and magnetic field. An edge MICER system consisting of 16 densely packed chords was recently installed on DIII-D, extending the MICER technique from the core to the pedestal and steep gradient region of H-mode plasmas where the D + and commonly measured impurity ion properties can differ significantly. A combination of iterative collisional radiative modeling techniques and greatly accelerated spectral fitting allowed the extension of this diagnostic technique to the plasma edge where the steep gradients introduce significant diagnostic challenges. The importance of including the fast ion Dα emission in the fit to the spectrum for the edge system is investigated showing that it is typically not important except for cases which can have significant fast ion fractions near the plasma edge such as QH-mode. Example profiles from an Ohmic L-mode and a high power ITER baseline case show large differences in the toroidal rotation of the two species near the separatrix including a strong co-current D + edge rotation. As a result, the measurements and analysis demonstrate the state of the art in active spectroscopy and integrated modeling for diagnosing fusion plasmas and the importance of direct main ion measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗