Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Data Release Report for the Source Physics Experiment Phase II: Dry Alluvium Geology Experiments (DAG-1 through DAG-4), Nevada National Security Site

The Dry Alluvium Geology (DAG) project was Phase II of the Source Physics Experiment and consisted of a series of four chemical explosive tests conducted in the same source hole on the Nevada National Security Site. This hole is located at 37.1146°N and -116.0693°W, with a surface elevation of 1,285.2 meters (m) (4,216.5 feet [ft]) above sea level. The first test (DAG-1) was conducted on July 20, 2018, at 16:51:52.67838 Coordinated Universal Time (UTC). The explosive source for DAG-1 was nitromethane initiated by a small plastic-bonded explosive (PBX) charge, detonated at the depth of 385.0 m (1,263.2 ft) below ground surface. DAG-1 had a trinitrotoluene (TNT) equivalent yield of 0.908 metric tons (2,002 pounds [lbs]). DAG-2 was conducted on December 19, 2018, at 18:45:56.92115 UTC. This test was the largest in the series, with a TNT equivalent yield of 50.997 metric tons (112,429 lbs). The explosive source for DAG-2 was nitromethane initiated by a small PBX charge, detonated at the depth of 299.8 m (983.6 ft) below ground surface. DAG-3 was conducted on April 27, 2019, at 15:49:01.84183 UTC. The explosive source for this test was nitromethane initiated by a small PBX charge, detonated at the depth of 149.9 m (492.0 ft) below ground surface. DAG-3 had a TNT equivalent yield of 0.908 metric tons (2,002 lbs). The final DAG test (DAG-4) was conducted on June 22, 2019, at 21:06:19.87632 UTC. The explosive source for DAG-4 was nitromethane initiated by a small PBX charge, detonated at the depth of 51.6 m (169.3 ft) below ground surface. DAG-4 had a TNT equivalent yield of 10.357 metric tons (22,833 lbs). The four tests were recorded by an extensive set of instrumentation that included sensors both at near-field (less than 200 m) and far-field (200 m or greater) distances. The near-field instruments consisted of three-component (3C) accelerometers installed at various depths ranging from 51.6 to 385 m (169.3 to 1,263.1 ft) below ground surface in boreholes positioned around the source hole, and arrays of single-component and 3C accelerometers on the surface. The far-field network comprised a variety of seismic and acoustic sensors, including short-period geophones, broadband seismometers, and 3C accelerometers at distances of 200 m to 400 kilometers. In addition, the DAG-2, DAG-3, and DAG-4 explosions were recorded by a temporary array of 496 geophones arranged in a densely spaced grid pattern known as “Large N.” This report coincides with the release of these data for analysts and organizations that are not participants in this program. This report describes the four DAG tests and the various types of near-field, far-field, and other data that are available. Assembled data sets are accessible through: Incorporated Research Institutions for Seismology, Data Management Center 1408 NE 45th Street, Suite 201, Seattle, Washington 98105 USA. www.iris.washington.edu

58 GEOSCIENCES↗

A Test for the Existence of Mach Effects with a Rotary Device

Owing to the variation in the results of several experiments designed to produce thrust with devices employing Mach effects, it was decided to design an experiment with the simple purpose of determining whether or not Mach effects actually exist, and if they can be produced when the ''bulk'' acceleration and internal energy changes required to produce them are separately supplied. In the experiment arrays of eight 500 pf high voltage capacitors are mounted on the end of a rotor and spun to and from speeds of about 60 Hz (3600 rpm) while they are excited with a 40 KHz voltage signal with amplitudes up to 6 KV. The capacitors are sandwiched between two accelerometers and any Mach effect mass fluctuation is detected as a weight fluctuation that produces signals in the accelerometers that are antiphase. Those signals are subtracted with a differential instrumentation amplifier that suppresses other signals as common mode noise. Signals with the properties sought have been found and recorded with video equipment. They suggest that Mach effects are real, and that the bulk accelerations and internal energy changes that produce them can in fact be separately supplied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Online Robot Dead Reckoning Localization Using Maximum Relative Entropy Optimization With Model Constraints

The principle of Maximum relative Entropy optimization was analyzed for dead reckoning localization of a rigid body when observation data of two attached accelerometers was collected. Model constraints were derived from the relationships between the sensors. The experiment's results confirmed that accelerometers each axis' noise can be successfully filtered utilizing dependency between channels and the dependency between time series data. Dependency between channels was used for a priori calculation, and a posteriori distribution was derived utilizing dependency between time series data. There was revisited data of autocalibration experiment by removing the initial assumption that instantaneous rotation axis of a rigid body was known. Performance results confirmed that such an approach could be used for online dead reckoning localization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

YCa{sub 4}O(BO{sub 3}){sub 3} (YCOB) high temperature vibration sensor

A shear-mode piezoelectric accelerometer using YCa{sub 4}O(BO{sub 3}){sub 3} (YCOB) single crystal was designed, fabricated and successfully tested for high temperature vibration sensing applications. The prototyped sensor was tested at temperatures ranging from room temperature to 1000 deg. C and at frequencies ranging from 80 Hz to 1 kHz. The sensitivity of the sensor was found to be 5.7 pC/g throughout the tested frequency and temperature range. In addition, YCOB piezoelectric accelerometers remained the same sensitivity at 1000 deg. C for a dwell time of four hours, exhibiting high stability and reliability.

36 MATERIALS SCIENCE↗

Incorporation of the stress concentration slots into the flexures for a high-performance microaccelerometer

Presented in this paper is a development of a high-performance piezoresistive microaccelerometer based on the slot etching in the quad flexures for the vibration detection of high speed spindle. The proposed structure consists of a proof mass supported by four thin flexures with slots etched in the middle. Boron diffused piezoresistors located near the stress concentration regions are used for sensing the localized stress resulting from the incorporation of the slots into the flexures. Theoretical analysis and finite element analysis show satisfactory results of an improved sensitivity and favorable natural frequency higher than 10 kHz, conforming to the initial design requirements. The microfabrication techniques are described to prototype the two accelerometer chips, one with slots and the other one without slots. The tested microaccelerometers with 3 V DC power supply show an average sensitivity of 0.424 mV/g normal to the proof mass plane, increased by 60.6% than the ones without slots. An average transverse sensitivity is found to be 9.2 {mu}V/g along X axis and 14.2 {mu}V/g along Y axis, either of which is less than 3.5% of prime-axis sensitivity. Concerning the resonant frequency, dynamic experiment shows about 12.46 kHz and is available for the proposed design with a tiny loss of 3.5% compared with the quad-beam design. When taking the product of sensitivity and natural frequency as judgment criteria, an inspiring increase by 28.6% of the figure of merit is accomplished for the proposed accelerometer. Overall, the findings of this study confirm the feasibility of incorporating slots into the conventional configurations to improve the sensor sensitivity while maintaining a comparatively high natural frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fission-powered in-core thermoacoustic sensor

A thermoacoustic engine is operated within the core of a nuclear reactor to acoustically telemeter coolant temperature (frequency-encoded) and reactor power level (amplitude-encoded) outside the reactor, thus providing the values of these important parameters without external electrical power or wiring. We present data from two hydrophones in the coolant (far from the core) and an accelerometer attached to a structure outside the reactor. Furthermore, these signals have been detected even in the presence of substantial background noise generated by the reactor's fluid pumps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EGS Collab Experiment 2: Continuous Active Source Seismic Monitoring (CASSM)

The dataset contains continuous active-source seismic monitoring (CASSM) data collected during EGS Collab Experiment 2, conducted from February to September 2022 at the Sanford Underground Research Facility in Lead, South Dakota. This experiment aimed to investigate enhanced geothermal systems through high-pressure fluid injections at depths of 1200-1500 meters. The seismic monitoring system included 16 three-component piezoelectric accelerometers and 24 hydrophones installed in boreholes around the injection zones, recording signals from piezoelectric seismic sources. Data were acquired using both continuous and triggered recording systems, with sampling rates of up to 100 kHz. The raw data are organized by timestamps and stored in .dat format, with accompanying log files. Calibration certificates for selected accelerometers are provided to aid in correcting sensor responses, though users are advised to consider possible effects of enclosures and installation on sensor performance. Users are strongly advised to consult the accompanying report, which outlines the experimental setup, data acquisition, sensor specifications, and recording systems.

15 GEOTHERMAL ENERGY↗

Phase Space Dissimilarity Measures for Structural Health Monitoring

A novel method for structural health monitoring (SHM), known as the Phase Space Dissimilarity Measures (PSDM) approach, is proposed and developed. The patented PSDM approach has already been developed and demonstrated for a variety of equipment and biomedical applications. Here, we investigate SHM of bridges via analysis of time serial accelerometer measurements. This work has four aspects. The first is algorithm scalability, which was found to scale linearly from one processing core to four cores. Second, the same data are analyzed to determine how the use of the PSDM approach affects sensor placement. We found that a relatively low-density placement sufficiently captures the dynamics of the structure. Third, the same data are analyzed by unique combinations of accelerometer axes (vertical, longitudinal, and lateral with respect to the bridge) to determine how the choice of axes affects the analysis. The vertical axis is found to provide satisfactory SHM data. Fourth, statistical methods were investigated to validate the PSDM approach for this application, yielding statistically significant results.

47 OTHER INSTRUMENTATION↗

The application of quaternions and other spatial representations to the reconstruction of re-entry vehicle motion.

The analysis of spacecraft kinematics and dynamics requires an efficient scheme for spatial representation. While the representation of displacement in three dimensional Euclidean space is straightforward, orientation in three dimensions poses particular challenges. The unit quaternion provides an approach that mitigates many of the problems intrinsic in other representation approaches, including the ill-conditioning that arises from computing many successive rotations. This report focuses on the computational utility of unit quaternions and their application to the reconstruction of re-entry vehicle (RV) motion history from sensor data. To this end they will be used in conjunction with other kinematic and data processing techniques. We will present a numerical implementation for the reconstruction of RV motion solely from gyroscope and accelerometer data. This will make use of unit quaternions due to their numerical efficacy in dealing with the composition of many incremental rotations over a time series. In addition to signal processing and data conditioning procedures, algorithms for numerical quaternion-based integration of gyroscope data will be addressed, as well as accelerometer triangulation and integration to yield RV trajectory. Actual processed flight data will be presented to demonstrate the implementation of these methods.

47 OTHER INSTRUMENTATION↗

Low-Power, Flexible Sensor Arrays with Solderless Board-to-Board Connectors for Monitoring Soil Deformation and Temperature

Landslides are a global and frequent natural hazard, affecting many communities and infrastructure networks. Technological solutions are needed for long-term, large-scale condition monitoring of infrastructure earthworks or natural slopes. However, current instruments for slope stability monitoring are often costly, require a complex installation process and/or data processing schemes, or have poor resolution. Wireless sensor networks comprising low-power, low-cost sensors have been shown to be a crucial part of landslide early warning systems. Here, we present the development of a novel sensing approach that uses linear arrays of three-axis accelerometers for monitoring changes in sensor inclination, and thus the surrounding soil’s deformation. By combining these deformation measurements with depth-resolved temperature measurements, we can link our data to subsurface thermal–hydrological regimes where relevant. In this research, we present a configuration of cascaded I2C sensors that (i) have ultra-low power consumption and (ii) enable an adjustable probe length. From an electromechanical perspective, we developed a novel board-to-board connection method that enables narrow, semi-flexible sensor arrays and a streamlined assembly process. The low-cost connection method relies on a specific FR4 printed circuit board design that allows board-to-board press fitting without using electromechanical components or solder connections. The sensor assembly is placed in a thin, semi-flexible tube (inner diameter 6.35 mm) that is filled with an epoxy compound. The resulting sensor probe is connected to an AA-battery-powered data logger with wireless connectivity. We characterize the system’s electromechanical properties and investigate the accuracy of deformation measurements. Our experiments, performed with probes up to 1.8 m long, demonstrate long-term connector stability, as well as probe mechanical flexibility. Furthermore, our accuracy analysis indicates that deformation measurements can be performed with a 0.390 mm resolution and a 95% confidence interval of ±0.73 mm per meter of probe length. This research shows the suitability of low-cost accelerometer arrays for distributed soil stability monitoring. In comparison with emerging low-cost measurements of surface displacement, our approach provides depth-resolved deformation, which can inform about shallow sliding surfaces.

deformation monitoring↗

Vibration-based health characterization of multiple IMUs in UAV applications

Inertial measurement units (IMUs) are vital in UAV navigation for vehicle attitude and position estimation, especially in the frequently-occurring case of temporary loss of GPS capabilities. Degradation in these units could yield inaccurate position estimates, resulting in incorrect input for vehicle control systems. A wide variety of these units exist to meet the needs of UAV operators, general aviation, and military vehicles. In recent decades, lightweight and inexpensive MEMS sensors have grown in popularity with respect to UAVs. Studies into the failure modes of MEMS devices suggest that vibration is one of the leading causes of MEMS degradation. MEMS sensors are generally encased in their own hermetic packaging, as their small size and sensitivity cause them to be particularly vulnerable to air damping and particulate contamination when exposed. Exposure to excessive vibration can cause cracking in this packaging as well as damage to connecting electronics, with recorded results that cause sensors to act outside of their specifications, potentially providing unreliable input to controllers. A prior study from the Politecnico di Torino looked into the degradation of MEMS IMUs, specifically the AXIS-AIS402, for aerospace and vibrating environments. In the study, the authors found that after exposing MEMS IMUs to simulated vibrations from working conditions of aerospace applications, the sensors showed increased noise and increased bias instability. At NASA Ames, several widely-used MEMS IMUs were selected for a new IMU degradation study, comparing accelerometer performance before and after exposure to similar levels of vibration simulating aerospace conditions. The IMUs were selected from the Pixhawk autopilot systems, hobby sUAS, or prior experimental studies at NASA. Additionally, the industrial grade VectorNav-100 IMU was selected as a ground truth reference point to which the performance of the test sensors can be compared. In the study, each sensor is exposed to functional levels of UAV vibration as replicated on a single-frequency vibratory table in the NASA Ames SHARP Laboratory, and each accelerometer is characterized for bias, drift, and noise characteristics both before and after vibratory exposure. The focus of this study is to monitor the health of the IMU sensors and determine if sensor degradation can be detected from output error and frequency spectrum analysis, rather than from microscopic examination of the sensors. In this case, sensor degradation and faulty data can be more easily detectable by non-experts hoping to use these sensors as an important piece of an integrated package. In addition, specific sensor degradation modes potentially leading to in-flight hazards could be identified, such as accelerated levels of drift and altered temperature response. The overall goal of this work is to increase levels of safety for future users of these sensors and to provide a clear analysis of sensor limitations currently lacking in most sensor specification documentation.

IMUs↗

Robust and optimal alignment of high-dimensional data using maximum likelihood estimation through a random sample consensus framework

Abstract Correcting spatial orientations of groups of high-dimensional data sets such that they are all in a consistent coordinate system is often a time-consuming and error-prone process. Automation of this process can be accomplished by using Generalized Procrustes Analysis to estimate the relative orientations among a population of high-dimensional data sets. A least squares Procrustes solution is applied through a maximum likelihood estimation and random sample consensus framework for robustness. The likelihood model is comprised of a mixture distribution where inliers are modeled using t -distribution and outliers from a uniform distribution. Applications will focus on a synthetic data set that emulates triaxial acceleration data and also real shock data from a population of triaxial accelerometers. Outliers represent either non-rigid body responses, environmental noise, and/or sensor and data acquisition issues. The intended application for the methodology is to robustly automate the rotation of populations of experimentally collected triaxial accelerometer data sets to a single global coordinate system.

LOSAC↗

Direct measurement of building transient and residual drift using an optical sensor system

Interstory drift (ID) is a key response parameter for buildings subjected to lateral loads and is used to define performance-based limit states, allowable deformations and damage states in a number of seismic design codes and standards. Here, an ability to rapidly and accurately measure both transient and residual ID during an earthquake would provide important observables for understanding the seismic demands and post-earthquake condition of a building. Accurate retrieval of ID from accelerometer-based instrumentation systems can be very challenging, if not impossible, as a result of instrumentation limitations and the post-processing associated with strong motion accelerometer data. This is particularly true for the case in which residual drifts occur during inelastic building response. In the study presented herein, a newly developed optical sensor system, designed specifically for directly measuring both transient and residual ID, was experimentally evaluated through shake table testing and computational simulations. The ability of the sensor to accurately measure ID is demonstrated and key operational considerations for sensor system deployment are examined through a model-based investigation.

42 ENGINEERING↗

Structural response reconstruction using a system-equivalent singular vector basis

Here, this paper develops a novel method for reconstructing the full-field response of structural dynamic systems using sparse measurements. The singular value decomposition is applied to a frequency response matrix relating the structural response to physical loads, base motion, or modal loads. The left singular vectors form a non-physical reduced basis that can be used for response reconstruction with far fewer sensors than existing methods. The contributions of the singular vectors to measured response are termed singular-vector loads (SVLs) and are used in a regularized Bayesian framework to generate full-field response estimates and confidence intervals. The reconstruction framework is applicable to the estimation of single data records and power spectral densities from multiple records. Reconstruction is successfully performed in configurations where the number of SVLs to identify is less than, equal to, and greater than the number of sensors used for reconstruction. In a simulation featuring a seismically excited shear structure, SVL reconstruction significantly outperforms modal FRF-based reconstruction and successfully estimates full-field responses with as few as two uniaxial accelerometers. SVL reconstruction is further verified in a simulation featuring an acoustically excited cylinder. Finally, response reconstruction and uncertainty quantification are performed on an experimental structure with three shaker inputs and 27 triaxial accelerometer outputs.

42 ENGINEERING↗

Comparison of sleep parameters from wrist-worn ActiGraph and Actiwatch devices

Abstract Sleep and physical activity, two important health behaviors, are often studied independently using different accelerometer types and body locations. Understanding whether accelerometers designed for monitoring each behavior can provide similar sleep parameter estimates may help determine whether one device can be used to measure both behaviors. Three hundred and thirty one adults (70.7 ± 13.7 years) from the Baltimore Longitudinal Study of Aging wore the ActiGraph GT9X Link and the Actiwatch 2 simultaneously on the non-dominant wrist for 7.0 ± 1.6 nights. Total sleep time (TST), wake after sleep onset (WASO), sleep efficiency, number of wake bouts, mean wake bout length, and sleep fragmentation index (SFI) were extracted from ActiGraph using the Cole–Kripke algorithm and from Actiwatch using the software default algorithm. These parameters were compared using paired t-tests, Bland–Altman plots, and Deming regression models. Stratified analyses were performed by age, sex, and body mass index (BMI). Compared to the Actiwatch, the ActiGraph estimated comparable TST and sleep efficiency, but fewer wake bouts, longer WASO, longer wake bout length, and higher SFI (all p < .001). Both devices estimated similar 1-min and 1% differences between participants for TST and SFI (β = 0.99, 95% CI: 0.95, 1.03, and 0.91, 1.13, respectively), but not for other parameters. These differences varied by age, sex, and/or BMI. The ActiGraph and the Actiwatch provide comparable absolute and relative estimates of TST, but not other parameters. The discrepancies could result from device differences in movement collection and/or sleep scoring algorithms. Further comparison and calibration is required before these devices can be used interchangeably.

Liu, Fangyu (ORCID:0000000315541478)↗

Surface recogniton for cars: A comprehensive approach for neural networks

This paper explores the viability of neural-networkbased classification of ground surface for vehicles. By classifying road surface in near realtime, improvements in vehicle performance (e.g. braking and cornering) may be possible. Classification performance for many combinations of feature encoding and neural network types are compared. The vehicle used here was an An Audi “S3” with a magnetic suspension system on the sport mode. An NI CompactRIO (or cDAQ) module was used to record from a lowing the cDAQ to communicate with the PCB 352C03 one-axis accelerometer. The accelerometer was firmly attached to the windshield of the car. This work focuses on the classification of four road surfaces (asphalt, dirt, concrete, and sand), though larger target sets were also considered. The most accurate method involved a MATLAB feature extraction package with a back-propagation neural network, yielding an overall accuracy of 97%. Lessons learned from this wide exploration of options may extend to other related classification problems.

33 ADVANCED PROPULSION SYSTEMS↗

Fast estimation of the look-elsewhere effect using Gaussian random fields

Abstract We discuss the use of Gaussian random fields to estimate the look-elsewhere effect correction. We show that Gaussian random fields can be used to model the null-hypothesis significance maps from a large set of statistical problems commonly encountered in physics, such as template matching and likelihood ratio tests. Some specific examples are searches for dark matter using pixel arrays, searches for astronomical transients, and searches for fast-radio bursts. Gaussian random fields can be sampled efficiently in the frequency domain, and the excursion probability can be fitted with these samples to extend any estimation of the look-elsewhere effect to lower p values. In addition, in cases where the Gaussian random field is stationary and the parameter space is Euclidean, the look-elsewhere effect correction can be computed analytically. We demonstrate these methods using two example template matching problems. Finally, we apply these methods to estimate the trial factor of a $$4^3$$ 4 3 accelerometer array for the detection of dark matter tracks in the Windchime project. When a global significance of $$3\sigma $$ 3 σ is required, the estimated trial factor for such an accelerometer array is $$10^{14}$$ 10 14 for a one-second search, and $$10^{22}$$ 10 22 for a 1-year search.

Qin, Juehang (ORCID:0000000182288949)↗

A vibro-haptic human-machine interface for structural health monitoring

The structural health monitoring (SHM) community’s goal has been to endow physical systems with a nervous system not unlike those commonly found in living organisms. Typically the SHM community has attempted to do this by instrumenting structures with a variety of sensors, and then applying various signal processing and classification procedures to the data in order to detect the presence of damage, the location of damage, the severity of damage, and to estimate the remaining useful life of the structure. This procedure has had some success, but we are still a long way from achieving the performance of nervous systems found in biology. This is primarily because contemporary classification algorithms do not have the performance required. In many cases expert judgment is superior to automated classification. This work introduces a new paradigm. We propose interfacing the human nervous system to the distributed sensor network located on the structure and developing new techniques to enable human-machine cooperation. Results from the field of sensory substitution suggest this should be possible. This study investigates a vibro-haptic human-machine interface for SHM. The investigation was performed using a surrogate three-story structure. The structure features three nonlinearity-inducing bumpers to simulate damage. Accelerometers are placed on each floor to measure the response of the structure to a harmonic base excitation. The accelerometer measurements are preprocessed. As a result, the preprocessed data is then encoded encoded as a vibro-tactile stimulus. Human subjects were then subjected to the vibro-tactile stimulus and asked to characterize the damage in the structure.

42 ENGINEERING↗