Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Safeguards Technology Development Program 1st Quarter FY 2018 Report

LLNL will evaluate the performance of a stilbene-based scintillation detector array for IAEA neutron multiplicity counting (NMC) applications. This effort will combine newly developed modeling methodologies and recently acquired high-efficiency stilbene detector units to quantitatively compare the prototype system performance with the conventional He-3 counters and liquid scintillator alternatives.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Safeguards Technology Development Program 3rd Quarter FY 2018 Report

LLNL will evaluate the performance of a stilbene-based scintillation detector array for IAEA neutron multiplicity counting (NMC) applications. This effort will combine newly developed modeling methodologies and recently acquired high-efficiency stilbene detector units to quantitatively compare the prototype system performance with the conventional He-3 counters and liquid scintillator alternatives.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Expanded beam deflection method for simultaneous measurement of displacement and vibrations of multiple microcantilevers

Here we present an extension of optical beam deflection (OBD) method for measuring displacement and vibrations of an array of microcantilevers. Instead of focusing on the cantilever, the optical beam is either focused above or below the cantilever array, or focused only in the axis parallel to the cantilevers length, allowing a wide optical line to span multiple cantilevers in the array. Each cantilever reflects a part of the incident beam, which is then directed onto a photodiode array detector in a manner allowing distinguishing between individual beams. Each part of reflected beam behaves like a single beam of roughly the same divergence angle in the bending sensing axis as the incident beam. Since sensitivity of the OBD method depends on the divergence angle of deflected beam, high sensitivity is preserved in proposed expanded beam deflection (EBD) method. At the detector, each spot's position is measured at the same time, without time multiplexing of light sources. This provides real simultaneous readout of entire array, unavailable in most of competitive methods, and thus increases time resolution of the measurement. Expanded beam can also span another line of cantilevers allowing monitoring of specially designed two-dimensional arrays. In this paper, we present first results of application of EBD method to cantilever sensors. We show how thermal noise resolution can be easily achieved and combined with thermal noise based resonance frequency measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SNM neutron detection using a time-gated synthetic aperture hybrid approach

This work focuses on using forward and adjoint transport in a hybrid application of 3-D deterministic (PENTRAN) and Monte Carlo (MCNP5) codes to model a series of neutron detector blocks. These blocks, or 'channels, ' contain a unique set of moderators with 4 atm He-3 detectors tuned to detect and profile a gross energy spectrum of a passing neutron (SNM) source. Ganging the units together as a large area system enables one to apply time gating the source-detector response to maximize signal to noise responses from a passing source with minimal background; multiple units may be positioned as a collective synthetic aperture detector array to be used as a way of performing real time neutron spectroscopy for detecting special nuclear materials in moving vehicles. The initial design, detector response coupling, confirmation of initial design functionality using adjoint transport calculations, and realistic simulation using PENTRAN and MCNP5 are presented. Future work will include optimization and application to realistic scenarios and additional sources. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Readout IC requirement trends based on a simplified parametric seeker model.

Modern space based optical sensors place substantial demands on the focal plane array readout integrated circuit. Active pixel readout designs offer direct access to individual pixel data but require analog to digital conversion at or near each pixel. Thus, circuit designers must create precise, fundamentally analog circuitry within tightly constrained areas on the integrated circuit. Rapidly changing phenomena necessitate tradeoffs between sampling and conversion speed, data precision, and heat generation adjacent the detector array, especially of concern for thermally sensitive space grade infrared detectors. A simplified parametric model is presented that illustrates seeker system performance and analog to digital conversion requirements trends in the visible through mid-wave infrared, for varying sample rate. Notional limiting-case Earth optical backgrounds were generated using MODTRAN4 with a range of cloud extremes and approximate practical albedo limits for typical surface features from a composite of the Mosart and Aster spectral albedo databases. The dynamic range requirements imposed by these background spectra are discussed in the context of optical band selection and readout design impacts.

47 OTHER INSTRUMENTATION↗

CORRELATIONS OF THE ARRIVAL DIRECTIONS OF ULTRA-HIGH ENERGY COSMIC RAYS WITH EXTRAGALACTIC OBJECTS AS OBSERVED BY THE TELESCOPE ARRAY EXPERIMENT

We search for correlations between the positions of extragalactic objects and the arrival directions of ultra-high energy cosmic rays (UHECRs) with primary energy E ≥ 40 EeV as observed by the surface detector array of the Telescope Array (TA) experiment during the first 40 months of operation. We examine several public astronomical object catalogs, including the Veron-Cetty and Veron catalog of active galactic nuclei. We count the number of TA events correlated with objects in each catalog as a function of three parameters: the maximum angular separation between a TA event and an object, the minimum energy of the events, and the maximum redshift of the objects. We determine the combination of these parameters that maximizes the correlations, and we calculate the probability of having the same levels of correlations from an isotropic distribution of UHECR arrival directions. No statistically significant correlations are found when penalties for scanning over the above parameters and for searching in several catalogs are taken into account.

79 ASTRONOMY AND ASTROPHYSICS↗

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials↗

Octupole collectivity in {sup 94}Zr

The Zr isotopes between {sup 90}Zr and {sup 96}Zr are expected to be spherical based on the almost complete subshell closures at Z = 40 and N = 50, 56. On the other hand, they have low-lying 3{sup -} states and show the characteristics of low frequency octupole oscillation which arise as a superposition of particle-hole excitations. A 380 MeV {sup 94}Zr beam from the tandem accelerator at the Japan Atomic Energy Agency (JAEA) was excited on a self-supporting {sup nat}Pb target. The gamma-ray detector array GEMINI-II was used to detect deexcitation gamma rays. The scattered beam ({sup 94}Zr) was detected with a position-sensitive particle detector system. The gamma-ray intensities were used as an input to the least-squares search code GOSIA to determine the E3 matrix element of the first 3{sup -} excited state of {sup 94}Zr. The B(E3;0{sup +}{yields}3{sup -}) value of 0.21(6)e{sup 2}b{sup 3} in {sup 94}Zr has been obtained by Coulomb excitation experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Capabilities of the INL ZPPR to Support Active Interrogation Research with SNM

For over 40 years Idaho National Laboratory (INL) and its predecessor organizations have maintained and operated the Zero-Power Physics Reactor (ZPPR) as a test bed for studying reactor physics and nuclear reactor design. Although the ZPPR is no longer operated as an active research reactor, it’s infrastructure (radiation shielding, safety systems, physical safeguards) and special nuclear material (SNM) inventory (variably enriched uranium and plutonium fuels available in metallic, oxide, alloy, and other forms) still makes the facility a unique national resource for research and development activities involving the use of SNM. Recently INL has utilized this facility to serve as a test and evaluation facility for active interrogation research and development. This facility is currently hosting scoping experiments using neutron and x-ray radiation sources to characterize SNM active interrogation signatures and to develop tools and techniques to detect and identify shielded SNM. This paper presents an overview of the facility’s infrastructure and assets and describes recent active interrogation experiments that have taken place using high-energy x-ray sources and compact electronic neutron generators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-compact optical true time delay device for wideband phased array radars.

An ultra-compact optical true time delay device is demonstrated that can support 112 antenna elements with better than six bits of delay in a volume 16-inch x 5-inch x 4-inch including the box and electronics. Free-space beams circulate in a White cell, overlapping in space to minimize volume. The 18 mirrors are slow-tool diamond turned on two substrates, one at each end, to streamline alignment. Pointing accuracy of better than 10 {micro}rad is achieved, with surface roughness {approx}45 nm rms. A MEMS tip-style mirror array selects among the paths for each beam independently, requiring {approx}100 {micro}s to switch the whole array. The micromirrors have 1.4{sup o} tip angle and three stable states (east, west, and flat). The input is a fiber-and-microlens array, whose output spots are re-imaged multiple times in the White cell, striking a different area of the single MEMS chip in each of 10 bounces. The output is converted to RF by an integrated InP wideband optical combiner detector array. Delays were accurate to within 4% (shortest delay) to 0.03% (longest mirror train). The fiber-to-detector insertion loss is 7.82 dB for the shortest delay path.

47 OTHER INSTRUMENTATION↗

Study of the Photon Strength Functions for Gadolinium Isotopes with the DANCE Array

The gadolinium isotopes are interesting for reactor applications as well as for medicine and astrophysics. The gadolinium isotopes have some of the largest neutron capture cross sections. As a consequence they are used in the control rod in reactor fuel assembly. From the basic science point of view, there are seven stable isotopes of gadolinium with varying degrees of deformation. Therefore they provide a good testing ground for the study of deformation dependent structure such as the scissors mode. Decay gamma rays following neutron capture on Gd isotopes are detected by the DANCE array, which is located at flight path 14 at the Lujan Neutron Scattering Center at Los Alamos National Laboratory. The high segmentation and close packing of the detector array enable gamma-ray multiplicity measurements. The calorimetric properties of the DANCE array coupled with the neutron time-of-flight technique enables one to gate on a specific resonance of a specific isotope in the time-of-flight spectrum and obtain the summed energy spectrum for that isotope. The singles gamma-ray spectrum for each multiplicity can be separated by their DANCE cluster multiplicity. Various photon strength function models are used for comparison with experimentally measured DANCE data and provide insight for understanding the statistical decay properties of deformed nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-spin structures in Xe 132 and Xe 133 and evidence for isomers along the N = 79 isotones

In this study, the transitional nuclei 132 Xe and 133 Xe are investigated after multinucleon-transfer (MNT) and fusion-evaporation reactions. Both nuclei are populated (i) in 136 Xe + 208 Pb MNT reactions employing the high-resolution Advanced GAmma Tracking Array (AGATA) coupled to the magnetic spectrometer PRISMA, (ii) in the 136 Xe + 198 Pt MNT reaction employing the GAMMASPHERE spectrometer in combination with the gas-detector array CHICO, and (iii) as an evaporation residue after a 130 Te (α,xn) 134-xn Xe fusion-evaporation reaction employing the HORUS γ -ray array at the University of Cologne. The high-spin level schemes are considerably extended above the J π = (7 - ) and (10 + ) isomers in 132 Xe and above the 11/2 - isomer in 133 Xe. The results are compared to the high-spin systematics of the Z = 54 as well as the N = 78 and N = 79 chains. Furthermore, evidence is found for a long-lived (T 1/ 2 » 1 μs) isomer in 133 Xe which closes a gap along the N = 79 isotones. Finally, shell-model calculations employing the SN100PN and PQM130 effective interactions reproduce the experimental findings and provide guidance to the interpretation of the observed high-spin features.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First demonstration of 30 eVee ionization energy resolution with RICOCHET germanium cryogenic bolometers

The future RICOCHET experiment aims to search for new physics in the electroweak sector by measuring the Coherent Elastic Neutrino-Nucleus Scattering process from reactor antineutrinos with high precision down to the sub-100 eV nuclear recoil energy range. While the RICOCHET collaboration is currently building the experimental setup at the reactor site, it is also finalizing the cryogenic detector arrays that will be integrated into the cryostat at the Institut Laue Langevin in early 2024. In this paper, we report on recent progress from the Ge cryogenic detector technology, called the CryoCube. More specifically, we present the first demonstration of a 30 eVee (electron equivalent) baseline ionization resolution (RMS) achieved with an early design of the detector assembly and its dedicated High Electron Mobility Transistor (HEMT) based front-end electronics with a total input capacitance of about 40 pF. This represents an order of magnitude improvement over the best ionization resolutions obtained on similar phonon-and-ionization germanium cryogenic detectors from the EDELWEISS and SuperCDMS dark matter experiments, and a factor of three improvement compared to the first fully-cryogenic HEMT-based preamplifier coupled to a CDMS-II germanium detector with a total input capacitance of 250 pF. Additionally, we discuss the implications of these results in the context of the future RICOCHET experiment and its expected background mitigation performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The GERDA Neutrinoless Double Beta-Decay Experiment

Neutrinoless double beta (0{nu}{beta}{beta})-decay is the key process to gain understanding of the nature of neutrinos. The GErmanium Detector Array (GERDA) is designed to search for 0{nu}{beta}{beta}-decay of the isotope {sup 76}Ge. Germanium crystals enriched in {sup 76}Ge, acting as source and detector simultaneously, will be submerged directly into an ultra pure cooling medium that also serves as a radiation shield. This concept will allow for a reduction of the background by up to two orders of magnitudes with respect to earlier experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photon noise limited radiation detection with lens-antenna coupled microwave kinetic inductance detectors

Microwave kinetic inductance detectors (MKIDs) have shown great potential for sub-mm instrumentation because of the high scalability of the technology. Here, we demonstrate for the first time in the sub-mm band (0.1-2 mm) a photon noise limited performance of a small antenna coupled MKID detector array and we describe the relation between photon noise and MKID intrinsic generation-recombination noise. Additionally, we use the observed photon noise to measure the optical efficiency of detectors to be 0.8 {+-} 0.2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron capture cross section measurements at the beam line 04 of J-PARC/MLF

An Accurate Neutron-Nucleus Reaction measurement Instrument (ANNRI) at the beam line 04 of MLF (Material and Life Sciences Experimental Facilities) of J-PARC (Japan Proton Accelerator Research Complex) was installed to measure neutron capture cross sections related to the research and development of innovative nuclear systems, the study on nuclear astrophysics, etc. ANNRI has two gamma-ray spectrometers: one is a Ge detector array placed at 22 m from the coupled type moderator of the spallation neutron source of J-PARC/MLF and the other is a pair of NaI(Tl) detectors at 28 m. Until the 11th of March, 2011, when we had big earthquakes, we measured capture cross sections of Zr-93, Tc-99, Pd-107, I-129, Cm-244, Cm-246, etc. After checking and repairing ANNRI, we restarted measurements, and ANNRI has been open to worldwide users at present.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-374: Sensitivity of ArcCHECK to Tomotherapy Delivery Errors: Dependence On Analysis Technique

Purpose: ArcCHECK (Sun Nuclear) is a cylindrical diode array detector allowing three-dimensional sampling of dose, particularly useful in treatment delivery QA of helical tomotherapy. Gamma passing rate is a common method of analyzing results from diode arrays, but is less intuitive in 3D with complex measured dose distributions. This study explores the sensitivity of gamma passing rate to choice of analysis technique in the context of its ability to detect errors introduced into the treatment delivery. Methods: Nine treatment plans were altered to introduce errors in: couch speed, gantry/sonogram synchronization, and leaf open time. Each plan was then delivered to ArcCHECK in each of the following arrangements: “offset,” when the high dose area of the plan is delivered to the side of the phantom so that some diode measurements will be on the order of the prescription dose, and “centered,” when the high dose is in the center of the phantom where an ion chamber measurement may be acquired, but the diode measurements are in the mid to low-dose region at the periphery of the plan. Gamma analysis was performed at 3%/3mm tolerance and both global and local gamma criteria. The threshold of detectability for each error type was calculated as the magnitude at which the gamma passing rate drops below 90%. Results: Global gamma criteria reduced the sensitivity in the offset arrangement (from 2.3% to 4.5%, 8° to 21°, and 3ms to 8ms for couch-speed decrease, gantry-error, and leaf-opening increase, respectively). The centered arrangement detected changes at 3.3%, 5°, and 4ms with smaller variation. Conclusion: Each arrangement has advantages; offsetting allows more sampling of the higher dose region, while centering allows an ion chamber measurement and potentially better use of tools such as 3DVH, at the cost of positioning more of the diodes in the sometimes noisy mid-dose region.

60 APPLIED LIFE SCIENCES↗

SU-D-BRE-04: Evaluating the Dose Accuracy of a 2D Ion Chamber Array in High Dose Rate Pencil Beam Scanning Proton Beam

Purpose: To evaluate the absolute dose accuracy of the PTW Octavius 729 XDR 2D ion chamber array at a high dose rate pencil beam scanning proton therapy facility. Methods: A set of 18 plans were created in our treatment planning system, each of which comprising a unique combination of field sizes (FS), length of spread out of Bragg peaks (SOBP) and depths. The parameters used were: FS of 5×5cm{sup 2}, 10×10cm{sup 2} and 15×15cm{sup 2}; flat SOBP of 5cm and 10cm; and isocenter depths of 10cm, 15cm and 20cm, which coincides with the center of the SOBP. The 2D array detector was positioned at the machine isocenter and the appropriate amount of solid water was used to match the planned depths of 10, 15 and 20 cm water equivalent depth. Subsequently, we measured the absolute dose at isocenter using a CC04 ion chamber in a 1D water tank. Both 2D array and CC04 were previously cross calibrated. We also collected the MU rates used by our proton machine from the log files. Results: The relative differences between the CC04 and the 2D array can be summarized into two groups, one with 5 cm SOBP and another with 10 cm SOBP. Plotting these datasets against FS shows that the 2D array response for high dose rate fields (FS of 5×5cm{sup 2} and 5cm SOBP) can be up to 2% lower. Similarly, plotting them against isocenter depths reveals the detector's response can be up to 2% lower for higher energy beams (about 200MeV nominal). The MU rate found in the machine log files for 5cm SOBP's were as high as twice the MU rate for the 10cm SOBP. Conclusion: The 2D array dose response showed a dose rate effect in scanning pencil beam delivery, which needs to be corrected to achieve a better dose accuracy.

07 ISOTOPE AND RADIATION SOURCES↗