Search NASA⌕ Search

SEARCH · Search NASA

Results for “bragg diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Patterned probes for high precision 4D-STEM bragg measurements

Nanoscale strain mapping by four-dimensional scanning transmission electron microscopy (4D-STEM) relies on determining the precise locations of Bragg-scattered electrons in a sequence of diffraction patterns, a task which is complicated by dynamical scattering, inelastic scattering, and shot noise. These features hinder accurate automated computational detection and position measurement of the diffracted disks, limiting the precision of measurements of local deformation. Here, we investigate the use of patterned probes to improve the precision of strain mapping. We imprint a "bullseye" pattern onto the probe, by using a binary mask in the probe-forming aperture, to improve the robustness of the peak finding algorithm to intensity modulations inside the diffracted disks. We show that this imprinting leads to substantially improved strain-mapping precision at the expense of a slight decrease in spatial resolution. In experiments on an unstrained silicon reference sample, we observe an improvement in strain measurement precision from 2.7% of the reciprocal lattice vectors with standard probes to 0.3% using bullseye probes for a thin sample, and an improvement from 4.7% to 0.8% for a thick sample. Additionally, we use multislice simulations to explore how sample thickness and electron dose limit the attainable accuracy and precision for 4D-STEM strain measurements.

47 OTHER INSTRUMENTATION↗

One dimensional focusing with high numerical aperture multilayer Laue lens

Multilayer Laue lenses (MLLs) capitalize on the developments in multilayer deposition technologies for fabricating reflective coatings, specifically undertaken for EUV lithography, where layer thicknesses of several nanometers can be achieved. MLLs are deposited layer by layer, with their thicknesses following the zone plate law, and then pieces are sliced and extracted for use in focusing. Rays are reflected in the Laue geometry. The efficiency of a MLL can be very high, and is maximized by making the slice equal to about a half Pendellosung period so that most energy is transferred from the undiffracted to the diffracted beam, and by ensuring that the Bragg condition is met at each point in the zone plate. This latter condition requires that the layers are tilted to the beam by an amount that varies with layer position; e.g. for focusing a collimated beam, the layers should be normal to a cylinder of radius of twice the focal length. We have fabricated such tilted-zone MLLs and find that they exhibit improved efficiency across their entire pupil as compared with parallel-zone MLLs. This leads to a higher effective NA of the optic and hence higher resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-energy focusing Laue monochromator for the diamond light source x-ray pair distribution function beamline I15-1

The I15-1 beamline, the new side station to I15 at the Diamond Light Source, will be dedicated to the collection of atomic pair distribution function data. A Laue monochromator will be used consisting of three silicon crystals diffracting X-rays at a common Bragg angle of 2.83°. The crystals use the (1 1 1), (2 2 0), and (3 1 1) planes to select 40, 65, and 76 keV X-rays, respectively, and will be bent meridionally to horizontally focus the selected X-rays onto the sample. All crystals will be cut to the same optimized asymmetry angle in order to eliminate image broadening from the crystal thickness. Finite element calculations show that the thermal distortion of the crystals will affect the image size and bandpass.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Zr-based bulk metallic glass as a cylinder material for high pressure apparatuses

Zirconium-based bulk metallic glass (Zr-based BMG) has outstanding properties as a cylinder mate- rial for piston-cylinder high pressure apparatuses and is especially useful for neutron scattering. The piston-cylinder consisting of a Zr-based BMG cylinder with outer/inner diameters of 8.8/2.5 mm sustains pressures up to 1.81 GPa and ruptured at 2.0 GPa, with pressure values determined by the superconduct- ing temperature of lead. The neutron attenuation of Zr-based BMG is similar to that of TiZr null-scattering alloy and more transparent than that of CuBe alloy. No contamination of sharp Bragg reflections is observed in the neutron diffraction pattern for Zr-based BMG. The magnetic susceptibility of Zr-based BMG is similar to that of CuBe alloy; this leads to a potential application for measurements of magnetic properties under pressure.

36 MATERIALS SCIENCE↗

Structure and magnetism of the triangular lattice material YbBO 3

Abstract YbBO 3 is a member of the orthoborate family of materials which contains a triangular arrangement of Yb 3+ ions. Here we study the physical properties of YbBO 3 with neutron diffraction, inelastic neutron scattering, specific heat, and ac susceptibility measurements. The neutron diffraction measurements confirm that our samples of YbBO 3 crystallize in the monoclinic space group C 2 / c (#15) which contains two crystallographically distinct Yb 3+ sites decorating a slightly distorted triangular lattice. Heat capacity and ac susceptibility measurements indicate a potential transition to magnetic order at 0.4 K. In agreement with these observations, neutron diffraction measurements at 0.044 K observe magnetic Bragg peaks which can be indexed by a propagation vector of (0 0 1). Although determining a unique spin configuration corresponding to the observed magnetic Bragg peaks is not possible, model refinements indicate that the ordered moments are likely in the range of 0.4–0.9 μ B and, notably, require moments on both Yb sites. In addition to the magnetic Bragg peaks, diffuse scattering at low Q is observed indicating that the transition does not correspond to complete long range magnetic order. The two-site picture for YbBO 3 is further evidenced by the number of crystal field excitations observed by inelastic neutron scattering measurements. Together these results show that YbBO 3 is a two-site triangular lattice material with signatures of long-range order as well as shorter ranged spin correlations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrafast Structural Dynamics along the β – γ Phase Transition Path in MnAs

We investigate the orthorhombic distortion and the structural dynamics of epitaxial MnAs layers on GaAs(001) using static and time-resolved x-ray diffraction. Laser-induced intensity oscillations of Bragg reflections allow us to identify the optical phonon associated with orthorhombic distortion and to follow its softening along the path towards an undistorted phase of hexagonal symmetry. Furthermore, the frequency of this mode falls in the THz range, in agreement with recent calculations. Incomplete softening suggests that the β–γ transformation deviates from a purely second-order displacive transition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time-domain sampling of x-ray pulses using an ultrafast sample response

We employ the ultrafast response of a 15.4 nm thin SrRuO{sub 3} layer grown epitaxially on a SrTiO{sub 3} substrate to perform time-domain sampling of an x-ray pulse emitted from a synchrotron storage ring. Excitation of the sample with an ultrashort laser pulse triggers coherent expansion and compression waves in the thin layer, which turn the diffraction efficiency on and off at a fixed Bragg angle during 5 ps. This is significantly shorter than the duration of the synchrotron x-ray pulse of 100 ps. Cross-correlation measurements of the ultrafast sample response and the synchrotron x-ray pulse allow to reconstruct the x-ray pulse shape.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interplay of pressure and temperature in modulating the magnetic properties of Cr 2 O 3

The spin-lattice interaction is pivotal in tailoring materials properties and is crucial for developing novel spintronic devices. Here, in the current work, we aim to explore the effects of pressure and temperature on the magnetic properties of Cr 2 O 3 to gain insights into its spin-lattice interaction. Through high-pressure neutron diffraction experiments, we observed an enhancement of the magnetic Bragg intensity with increasing pressure and it becomes more pronounced as the temperature increases. Results from first-principles calculations reveal a strengthening of the easy-axis magnetic anisotropy, doubling from 0 to 20 GPa. The exchange parameters, calculated based on this spin orientation, show an enhancement of the dominant magnetic interactions and an increase of magnetic ordering temperature when pressure increases. These findings suggest that the contributions from these two mechanisms are responsible for the observed increase in magnetic Bragg intensity.

Cr2O3↗

Magnetic properties of (Mo 2/3 Dy 1/3 ) 2 AlC arc melted polycrystalline samples

Here, this study investigates the structural and magnetic properties of arc-melted (Mo 2/3 Dy 1/3 ) 2 AlC polycrystalline samples, a member of the i-MAX phase family. Temperature-dependent magnetization and specific heat measurements confirm the low-temperature antiferromagnetic transitions around 14 K and 17 K. Neutron diffraction data collected at 4 K reveal the emergence of magnetic Bragg peaks that are not allowed in the paramagnetic space group C2/c, further confirming the presence of antiferromagnetic ordering. The detection of a secondary phase, DyAl 2 , is complicated by overlapping Bragg peaks with the monoclinic phase of (Mo 2/3 Dy 1/3 ) 2 AlC in powder XRD patterns. However, magnetization and neutron diffraction data suggest the presence of DyAl 2 , evidenced by a ferromagnetic phase transition around 62 K.

36 MATERIALS SCIENCE↗

X-ray diffraction effect from surface acoustic waves traveling on a deposited multilayer

We investigate the x-ray diffraction effects from surface acoustic waves (SAW) traveling along a multilayer. The diffraction intensity distribution depends on the incidence angle and the multilayer SAW (MLSAW) amplitude. Particularly, a small departure deviating from the Bragg incidence angle at a certain amplitude will produce a larger variation of the intensity distribution. This shows that the diffraction intensity from MLSAW has an extremely high sensitivity to the Bragg incidence angle, which is different from a SAW traveling along a solid surface without deposited layers. By carefully analyzing the relationship between the intensity distribution I and the incidence angle {theta}, the corresponding analytic expression of the intensity distribution is theoretically derived. Our theoretical prediction is in great agreement with the experimental results previously obtained. A theoretical model that can be applied to study the x-ray diffraction effect from MLSAW is developed. The extremely high sensitivity to the Bragg angle will help us in acousto-optic instrument research with MLSAW.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for octupolar order in NpO 2 by neutron powder diffraction

The magnetic structure of neptunium dioxide (NpO 2 ) remains a mystery despite decades of research. We revisited the search for magnetic ordering in NpO 2 by performing a powder neutron diffraction experiment at low temperatures and relatively large values of Q. Diffraction data were collected for 300 MK, 15 K, and 35 K to understand the phase transition near 25 K. However, no significant changes in the neutron diffraction pattern were identified. Using the octupolar magnetic form factor j 6 , the maximum theoretical expected value of the magnetic moment (3.27 μ B ), the calculated magnetic Bragg peak intensities would not be observable in neutron powder diffraction data. This value is much larger than the previously estimated magnetic moment of ~0.1 μ B . In conclusion, supported by experimental results, these calculations suggest that unpolarized neutron powder diffraction is unsuitable for measuring octupolar ordering in NpO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic and thermodynamic properties of NdT{sub 2}Ge{sub 2} (T=Pd, Ag) compounds

Physical properties of NdPd{sub 2}Ge{sub 2} and NdAg{sub 2}Ge{sub 2}, crystallizing with the tetragonal ThCr{sub 2}Si{sub 2}-type crystal structure, were investigated by means of magnetic, calorimetric, electrical transport as well as by neutron diffraction measurements. The specific heat studies and neutron diffraction measurements were performed down to 0.30 K and 0.47 K, respectively. Both compounds exhibit antiferromagnetic ordering below T{sub N} equal to 1.5 K for NdPd{sub 2}Ge{sub 2} and 1.8 K for NdAg{sub 2}Ge{sub 2}. Neutron diffraction data for the latter germanide indicate antiferromagnetic collinear structure described by the propagation vector k=(0.5, 0, 0.5). The Nd magnetic moments equal to 2.24(5) mu{sub B} at 0.47 K are aligned along the a-axis and have the +- sequence within the crystal unit cell. For NdPd{sub 2}Ge{sub 2} only very small Bragg peaks of magnetic origin were observed in the neutron diffraction patterns measured below T{sub N}, thus hampering determination of the magnetic structure. Both compounds exhibit metallic-like electrical conduction. From the specific heat data the crystal electric field (CEF) levels schemes were determined. Difference between the overall CEF splitting in the two compounds is correlated with their structural parameters. - Graphical abstract: Low-temperature specific heat of NdAg{sub 2}Ge{sub 2} under external magnetic fields. The lambda-like anomaly originates from onset of magnetic ordering below 1.80 K. Shifting the anomaly position towards the lower temperatures, when raising the magnetic field, hints at antiferromagnetic behaviors.

36 MATERIALS SCIENCE↗

Improved crystal orientation and physical properties from single-shot XFEL stills

X-ray free-electron laser crystallography relies on the collection of still-shot diffraction patterns. New methods are developed for optimal modeling of the crystals’ orientations and mosaic block properties. X-ray diffraction patterns from still crystals are inherently difficult to process because the crystal orientation is not uniquely determined by measuring the Bragg spot positions. Only one of the three rotational degrees of freedom is directly coupled to spot positions; the other two rotations move Bragg spots in and out of the reflecting condition but do not change the direction of the diffracted rays. This hinders the ability to recover accurate structure factors from experiments that are dependent on single-shot exposures, such as femtosecond diffract-and-destroy protocols at X-ray free-electron lasers (XFELs). Here, additional methods are introduced to optimally model the diffraction. The best orientation is obtained by requiring, for the brightest observed spots, that each reciprocal-lattice point be placed into the exact reflecting condition implied by Bragg’s law with a minimal rotation. This approach reduces the experimental uncertainties in noisy XFEL data, improving the crystallographic R factors and sharpening anomalous differences that are near the level of the noise.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Asymmetric-cut variable-incident-angle monochromator

A novel asymmetric-cut variable-incident-angle monochromator was constructed and tested in 1997 at the Advanced Photon Source of Argonne National Laboratory. The monochromator was originally designed as a high heat load monochromator capable of handling 5-10 kW beams from a wiggler source. This was accomplished by spreading the x-ray beam out on the surface an asymmetric-cut crystal and by using liquid metal cooling of the first crystal. The monochromator turned out to be a highly versatile monochromator that could perform many different types of experiments. The monochromator consisted of two 18 deg. asymmetrically cut Si crystals that could be rotated about 3 independent axes. The first stage ({Phi}) rotates the crystal around an axis perpendicular to the diffraction plane. This rotation changes the angle of the incident beam with the surface of the crystal without changing the Bragg angle. The second rotation ({Psi}) is perpendicular to the first and is used to control the shape of the beam footprint on the crystal. The third rotation ({Theta}) controls the Bragg angle. Besides the high heat load application, the use of asymmetrically cut crystals allows one to increase or decrease the acceptance angle for crystal diffraction of a monochromatic x-ray beam and allows one to increase or decrease the wavelength bandwidth of the diffraction of a continuum source like a bending-magnet beam or a normal x-ray-tube source. When the monochromator is used in the doubly expanding mode, it is possible to expand the vertical size of the double-diffracted beam by a factor of 10-15. When this was combined with a bending magnet source, it was possible to generate an 8 keV area beam, 16 mm wide by 26 mm high with a uniform intensity and parallel to 1.2 arc sec that could be applied in imaging experiments.

43 PARTICLE ACCELERATORS↗

λ/2 contamination in X-ray diffraction data – the impact of heavy atoms

The impact of very different values of f ' and f " and of absorption coefficients for the wavelengths λ and λ/2 for heavy elements, and the effect of the difference in wavelength dispersion on the profile of the corresponding Bragg reflections, are discussed with respect to the correction of diffraction data for λ/2 contamination. The impact on the results of four charge-density studies is discussed.

Chemistry↗

Lawrence Bragg, microdiffraction and X-ray lasers

We trace the historical development of W. L. Bragg's `law' and the key experimental observation which made it possible using polychromatic radiation at a time when neither X-ray wavelengths nor cell constants were known. This led, through his phasing and solving large mineral structures (without use of a computer), to work on metals, proteins, bubble rafts and his X-ray microscope. The relationship of this to early X-ray microdiffraction is outlined, followed by a brief review of electron microdiffraction methods, where electron-probe sizes smaller than one unit cell can be formed with an interesting `failure' of Bragg's law. We end with a review of recent femtosecond X-ray `snapshot' diffraction from protein nanocrystals, using an X-ray laser which generates pulses so short that they terminate before radiation damage can commence, yet subsequently destroy the sample. Using short pulses instead of freezing, the nexus between dose, resolution and crystal size has been broken, opening the way to time-resolved diffraction without damage for a stream of identical particles.

36 MATERIALS SCIENCE↗

Measuring and modeling diffuse scattering in protein X-ray crystallography

X-ray diffraction has the potential to provide rich information about the structural dynamics of macromolecules. To realize this potential, both Bragg scattering, which is currently used to derive macromolecular structures, and diffuse scattering, which reports on correlations in charge density variations, must be measured. Until now, measurement of diffuse scattering from protein crystals has been scarce because of the extra effort of collecting diffuse data. Here, we present 3D measurements of diffuse intensity collected from crystals of the enzymes cyclophilin A and trypsin. The measurements were obtained from the same X-ray diffraction images as the Bragg data, using best practices for standard data collection. To model the underlying dynamics in a practical way that could be used during structure refinement, we tested translation–libration–screw (TLS), liquid-like motions (LLM), and coarse-grained normal-modes (NM) models of protein motions. The LLM model provides a global picture of motions and was refined against the diffuse data, whereas the TLS and NM models provide more detailed and distinct descriptions of atom displacements, and only used information from the Bragg data. Whereas different TLS groupings yielded similar Bragg intensities, they yielded different diffuse intensities, none of which agreed well with the data. In contrast, both the LLM and NM models agreed substantially with the diffuse data. In conclusion, these results demonstrate a realistic path to increase the number of diffuse datasets available to the wider biosciences community and indicate that dynamics-inspired NM structural models can simultaneously agree with both Bragg and diffuse scattering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗