Search NASA⌕ Search

SEARCH · Search NASA

Results for “clock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Data processor with conditionally supplied clock signals

Parallel data processor clock pulses are conditionally supplied to processing unit in response to relative values of binary bit of control source and binary bit derived on single lead. Use of single lead simplifies fabrication of large-scale integrated networks.

Lesniewski, R. J.↗

An analysis and demonstration of clock synchronization by VLBI

A prototype of a semi-real time system for synchronizing the Deep Space Net station clocks by radio interferometry was successfully demonstrated on August 30, 1972. The system utilized an approximate maximum likelihood estimation procedure for processing the data, thereby achieving essentially optimum time sync estimates for a given amount of data, or equivalently, minimizing the amount of data required for reliable estimation. Synchronization accuracies as good as 100 ns rms were achieved between Deep Space Stations 11 and 12, both at Goldstone, Calif. The accuracy can be improved by increasing the system bandwidth until the fundamental limitations due to baseline and source position uncertainties and atmospheric effects are reached. These limitations are under 10 ns for transcontinental baselines.

Hurd, W. J.↗

An analysis and demonstration of clock synchronization by VLBI

A prototype of a semireal-time system for synchronizing the DSN station clocks by radio interferometry was successfully demonstrated. The system utilized an approximate maximum likelihood estimation procedure for processing the data, thereby achieving essentially optimum time synchronization estimates for a given amount of data, or equivalently, minimizing the amount of data required for reliable estimation. Synchronization accuracies as good as 100 nsec rms were achieved between DSS 11 and DSS 12, both at Goldstone, California. The accuracy can be improved by increasing the system bandwidth until the fundamental limitations due to position uncertainties of baseline and source and atmospheric effects are reached. These limitations are under ten nsec for transcontinental baselines.

Hurd, W. J.↗

Demonstration of intercontinental DSN clock synchronization by VLBI

The prototype system for Deep Space Network clock synchronization by VLBI has been demonstrated to operate successfully over intercontinental baselines in a series of experiments between Deep Space Stations at Madrid, Spain, and Goldstone, California. As predicted by analysis and short baseline demonstration, the system achieves reliable synchronization between 26m and 64m antenna stations with 17 and 37K nominal system temperatures using under one million bits of data from each station. Semi-real-time operation is feasible since this small amount of data can be transmitted to JPL and processed within minutes. The system resolution is 50 to 400ns, depending on the amount of data processed and the source intensity. The accuracy is believed to be comparable to the resolution, although it could be independently confirmed to only about 5 microseconds using LORAN C.

Hurd, W. J.↗

Gravitational clock: A proposed experiment for the measurement of the gravitational constant G

The increased importance and the fundamental significance of accurately measuring the gravitational constant G are discussed along with recent or proposed experimental measurements of G. The method of using mutually gravitating bodies in the clock mode in a drag-free satellite is described. A satellite experiment consisting of the flat-plate spherical mass oscillator proposed combines the mathematical and experimental conveniences most simply. It is estimated that accuracies of 1 part in 1,000,000 are easily obtainable by careful fabrication of parts. The use of cryogenic techniques, thin films, and superconductors allows increased accuracies of two or three orders of magnitude or better. These measurements can be increased to the level of 1 part in 10 to the 11th power at which time-variations, and other variations, in G can be observed.

Smalley, L. L.↗

Preliminary demonstration of precision DSN clock synchronization by radio interferometry

A wideband digital data acquisition system has been developed to measure the clock offsets to the 10-ns accuracy required to facilitate three-way spacecraft ranging, to monitor the hydrogen maser frequency standard rates to 1 part in 10 to the forteenth power and to potentially reduce operational costs by replacing the current DSN operational time sync system.

Hurd, W. J.↗

Hybrid clock generator

Clock driver hybrid for hand-held vital signs monitor generates all frequencies required for operation of vital signs system in compact low power configuration.

Rinard, G. A.↗

Speed of light as measured by two terrestrial stable clocks

Despite the recent criticism within the special theory of relativity, there exists an arrangement of stable clocks rotating with the earth which predicts diurnal variations of the one-way speed of light, as suggested previously.

Hsu, J. P.↗

Shielding of longitudinal magnetic fields with thin, closely, spaced concentric cylindrical shells with applications to atomic clocks

A general formula is given for the longitudinal shielding effectiveness of N closed concentric cylinders. The use of these equations is demonstrated by application to the design of magnetic shields for hydrogen maser atomic clocks. Examples of design tradeoffs such as size, weight, and material thickness are discussed. Experimental results on three sets of shields fabricated by three manufacturers are presented. Two of the sets were designed employing the techniques described. Agreement between the experimental results and the design calculations is then demonstrated.

Wolf, S. A.↗

Fiber optics transmit clock signal more reliably

Optical automatic gain control smooths maser clock amplitude fluctuations without phase shift. Uncomplicated optical system is more reliable than electrical transmission circuits which require phase-locked loops to compensate for shift. Maser feeds reference signal to linear fiber-optic analog transmitter which emits modulated laser beam directed to splitter. Splitter consists of dichroic mirrors and associated lenses for distributing beam to output ports. Cables attached there guide signals to receiving station.

Lutes, G. F., Jr.↗

Limitations on long-term stability and accuracy in atomic clocks

The limits to accuracy and long term stability in present atomic clocks are examined. Recent proposals for new frequency standards are discussed along with the advantages and disadvantages of frequency standards based on such ideas as laser transitions, single atoms, and atom cooling. The applicability of some of these new techniques to existing standards is examined.

Wineland, D. J.↗

Early results from a prototype VLBI clock monitoring system

Four sets of experiments were conducted to measure the relative epoch offsets between atomic clocks in California, Australia, and Spain by means of very long baseline interferometry (VLBI). The experiments were conducted using an incomplete R & D VLBI system with a number of inherent limitations. The results indicate that the measurement objective of epoch offset to 10 nanoseconds will be met. Tables show the measured offset, the residual to fit, and the square root Allan variance. Graphs show the rate change and the rate reset.

Yunck, T. P.↗

Short turn-around intercontinental clock synchronization using very-long-baseline interferometry

During the past year work was accomplished to bring into regular operation a VLBI system for making intercontinental clock comparisons with a turn around of a few days from the time of data taking. Earlier VLBI systems required several weeks to produce results. The present system, which is not yet complete, incorporates a number of refinements not available in earlier systems, such as dual frequency inosopheric delay cancellation and wider synthesized bandwidths with instrumental phase calibration.

Madrid, G. A.↗

Digital processing clock

Tthe digital processing clock SG 1157/U is described. It is compatible with the PTTI world where it can be driven by an external cesium source. Built-in test equipment shows synchronization with cesium through 1 pulse per second. It is built to be expandable to accommodate future time-keeping needs of the Navy as well as any other time ordered functions. Examples of this expandibility are the inclusion of an unmodulated XR3 time code and the 2137 modulate time code (XR3 with 1 kHz carrier).

Phillips, D. H.↗

Intercontinental clock synchronization with the block 1 VLBI system

The Block 1 very long baseline interferometer (VLBI) operated by the Deep Space Network (DSN) to make weekly measurements of the relative epoch and rate offsets between the time standards in the global network of DSN stations is discussed. The precision of these measurements routinely achieves sub-microsecond levels for epoch offset and accuracies of better than one part in 10 to the 12th power for rate offset. The implementation of the phase calibrator system permits absolute measurement of epoch offset to better than 10 nanoseconds. With the near-real-time play-back and on-line storage of VLBI data, the Block 1 system typically produces clock parameters within 48 hours from the time of observation.

Roth, M. G.↗

The effects of transmitter/receiver clock time-base instability on coherent communication system performance

The purpose of this paper is to present a model and associated analysis of the deleterious effects which both transmitter and receiver data clock time-base instability have on bit-error probability. The types of time-base instability modeled and analyzed include what is commonly referred to as bit jitter (epoch jitter), bit-jitter rate (time interval jitter), and data asymmetry. The bit-error probability is determined as a function of the statistical characteristics of the time-base instability, the data-transition density, the signal-to-noise ratio in the bit-rate bandwidth and the mechanizations of both the data-bit detector and bit synchronizer. The latter is manifested through the bit synchronizer's natural frequency and loop-damping parameters. Numerical results which indicate the sensitivity of the system bit-error rate to various parameters of the model are provided.

Chie, C. M.↗

A rubidium clock for SEEK-TALK

The development of a tactical rubidium frequency standard (TRFS) for the SEEK-TALK program is discussed. This effort, which is entering the prototype stage, is directed toward the establishment of a production capability for miniature rubidium clocks of medium stability capable of fast warmup and extreme ruggedness for military avionics applications. The overall unit consists of an ultraminiature physics package and four plug-in circuit boards inside a 2 1/2-inch square by 4-inch box. This size is achieved without the extensive use of hybrid microcircuitry, yet is believed to be the smallest atomic frequency standard yet developed.

Riley, W. J.↗