Search NASA⌕ Search

SEARCH · Search NASA

Results for “coherence measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Doppler Lidar for Wind Measurements on Venus

NASA Langley Research Center has a long history of developing 2-micron laser transmitter for wind sensing. With support from NASA Laser Risk Reduction Program (LRRP) and Instrument Incubator Program (IIP), NASA Langley Research Center has developed a state-of-the-art compact lidar transceiver for a pulsed coherent Doppler lidar system for wind measurement. The transmitter portion of the transceiver employs the high-pulse-energy, Ho:Tm:LuLiF, partially conductively cooled laser technology developed at NASA Langley. The transceiver is capable of 250 mJ pulses at 10 Hz. It is very similar to the technology envisioned for coherent Doppler lidar wind measurements from Earth and Mars orbit. The transceiver is coupled to the large optics and data acquisition system in the NASA Langley VALIDAR mobile trailer. The large optics consists of a 15-cm off-axis beam expanding telescope, and a full-hemispheric scanner. Vertical and horizontal vector winds are measured, as well as relative backscatter. The data acquisition system employs frequency domain velocity estimation and pulse accumulation. It permits real-time display of the processed winds and archival of all data. This lidar system was recently deployed at Howard University facility in Beltsville, Mary-land, along with other wind lidar systems. Coherent Doppler wind lidar ground-based wind measurements and comparisons with other sensors will be presented. A simulation and data product for wind measurement at Venus will be presented.

Singh, Upendra N.↗

Structural properties of aqueous grown polydopamine thin films determined by neutron reflectometry

Here, in this work, neutron reflectometry (NR) studies of the bio-mimetic polymer, polydopamine (PDA), deposited from differing initial concentrations of precursor material dopamine hydrochloride for a range of polymerization times, is reported. PDA can form a complex and highly versatile polymer film, with many structure studies having been performed previously, but a comprehensive structural determination of PDA by NR is lacking in the literature. It was found that simple box models were incapable of fully explaining the observed data, necessitating the use of a composite model consisting of the weighted average of both the 1 and 2 box models to fully capture the heterogeneous nature of the PDA film structure. Confocal laser scanning microscopy (CLSM) and atomic force microscopy (AFM) were performed to capture the surface structure and relative mechanical difference between the separate domains of the PDA. The CLSM results provide evidence that the PDA domains are larger than the coherent scattering length of a neutron used in these measurements, 10μm, supporting the need for a composite model. The AFM measurements show complex structure below the coherence length provide physical justification for the two box model. It was determined that film structure and quality are both heavily impacted by the initial concentration of dopamine hydrochloride and the polymerization time, giving confidence to the highly customizable nature of PDA as an adhesion promoting interface treatment in composite systems, such as plastic bonded explosives (PBX).

36 MATERIALS SCIENCE↗

Toward coherent quantum computation of scattering amplitudes with a measurement-based photonic quantum processor

In recent years, applications of quantum simulation have been developed to study the properties of strongly interacting theories. This has been driven by two factors: on the one hand, needs from theorists to have access to physical observables that are prohibitively difficult to study using classical computing; on the other hand, quantum hardware becoming increasingly reliable and scalable to larger systems. In this work, we discuss the feasibility of using quantum optical simulation for studying scattering observables that are presently inaccessible via lattice QCD and are at the core of the experimental program at Jefferson Laboratory, the future Electron-Ion Collider, and other accelerator facilities. We show that recent progress in measurement-based photonic quantum computing can be leveraged to provide deterministic generation of required exotic gates and implementation in a single photonic quantum processor. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Considerations for Designing a Space Based Coherent Doppler Lidar

An orbiting coherent Doppler lidar for measuring winds is required to provide two basic pieces of data to the user community. The first is the line of sight wind velocity and the second is knowledge of the position at which the measurement was made. In order to provide this information in regions of interest the instrument is also required to have a certain backscatter sensitivity level. This paper outlines some of the considerations necessary in designing a coherent Doppler lidar for this purpose.

Spiers, Gary D.↗

Continuous Feedback and Macroscopic Coherence

We show that a model, recently introduced for quantum nondemolition measurements of a quantum observable, can be adapted to obtain a measurement scheme which is able to slow down the destruction of macroscopic coherence due to the measurement apparatus.

Tombesi, Paolo↗

Use of coherence and phase data between two receivers in evaluation of noise environments

For certain types of noise control problems, where transducers cannot be mounted on suspected sources, valuable information can often be obtained by comparing the coherence and phase data measured between two closely spaced microphones with analytical models deduced from the physics of the problem. However, the application of such analysis techniques must be pursued with care, particularly when the measurements are made in a reverberant area. A simple illustration is presented where the acoustic field in the test section of a wind tunnel is evaluated by modelling the field as a combination of diffuse noise due to the boundary layer turbulence in the test section and propagating noise generated by the tunnel fan and possible flow disturbances outside the test section. The coherence and phase between two closely spaced microphones in the tunnel test section are predicted for various ratios of diffuse to propagating noise contributions and compared to actual measurements under several different tunnel operating conditions.

Piersol, A. G.↗

SPARCLE Optical System Design and Operational Characteristics

The SPAce Readiness Coherent Lidar Experiment (SPARCLE) is the first demonstration of a coherent Doppler wind lidar in space. SPARCLE will be flown aboard a space shuttle In the middle part of 2001 as a stepping stone towards the development and deployment of a long-life-time operational instrument in the later part of next decade. SPARCLE is an ambitious project that is intended to evaluate the suitability of coherent lidar for wind measurements, demonstrate the maturity of the technology for space application, and provide a useable data set for model development and validation. This paper describes the SPARCLE's optical system design, fabrication methods, assembly and alignment techniques, and its anticipated operational characteristics. Coherent detection is highly sensitive to aberrations in the signal phase front, and to relative alignment between the signal and the local oscillator beams. Consequently, the performance of coherent lidars is usually limited by the optical quality of the transmitter/receiver optical system. For SPARCLE having a relatively large aperture (25 cm) and a very long operating range (400 km), compared to the previously developed 2-micron coherent lidars, the optical performance requirements are even more stringent. In addition with stringent performance requirements, the physical and environment constraints associated with this instrument further challenge the limit of optical fabrication technologies.

Amzajerdian, Farzin↗

Mean-field model for the Curie-Weiss temperature dependence of coherence length in metallic liquids

The coherence length of the medium-range order (MRO) in metallic liquids is known to display a Curie-Weiss temperature dependence; its inverse is linearly related to temperature, and when extrapolated from temperatures above the glass transition, the coherence length diverges at a negative temperature with a critical exponent of unity. We propose a mean-field pseudospin model that explains this behavior. Specifically, we model the atoms and their local environment as Ising spins with antiferromagnetic exchange interactions. We further superimpose an exchange interaction between dynamical heterogeneities, or clusters of atoms undergoing cooperative motion. The coherence length in the metallic liquid is thus the correlation length between dynamical heterogeneities. Overall, our results reaffirm the idea that the MRO coherence length is a measure of point-to-set correlations, and that local frustrations in the interatomic interactions are prominent in metallic liquids.

36 MATERIALS SCIENCE↗

Coherence and phase techniques applied to noise diagnosis in the NASA Ames 7 times 10-foot wind tunnel no. 1

Measurements have been made of coherence and phase spectra for the acoustic field in a subsonic wind tunnel. The data are interpreted in terms of simple analytical models for propagating and diffuse noise fields, including the presence of uncorrelated noise signals. It is found that low frequency noise propagates upstream and downstream from the fan, with the noise in the test section arriving in the upstream direction. High frequency sound is generated in the test section and propagates upstream and downstream. In the low frequency range, the ratio of diffuse to propagating energy is about eight for all locations in the test section, diffuser, and settling chamber; the value of the ratio increases with frequency.

Wilby, J. F.↗

Doppler and range determination for deep space vehicles using active optical transponders

This paper describes and analyzes two types of laser system employing active transponders that could accurately determine Doppler and range to deep space vehicles from earth-orbiting satellites. The first is a noncoherent optical system in which the Doppler effect on an intensity-modulating subcarrier is measured. The second is a coherent optical system in which the Doppler effect of the optical carrier itself is measured. Doppler and range measurement errors are mathematically modeled and, for three example systems, numerically evaluated.

Kinman, Peter W.↗

Atmospheric backscatter vertical profiles at 9.2 and 10.6 microns - A comparative study

The paper reports a series of atmospheric aerosol backscatter measurements at two widely spaced CO2 laser wavelengths: 9.25 and 10.6 microns. Comparisons are made between backscatter coefficient profiles at these two wavelengths up to 20-km altitude. Measurements such as those reported here can be used to assess the feasibility of coherent CO2 lidar for wind measurements, and they also provide a partial test of backscatter model predictions.

Ancellet, Gerard M.↗

Analysis of Technology for Compact Coherent Lidar

In view of the recent advances in the area of solid state and semiconductor lasers has created new possibilities for the development of compact and reliable coherent lidars for a wide range of applications. These applications include: Automated Rendezvous and Capture, wind shear and clear air turbulence detection, aircraft wake vortex detection, and automobile collision avoidance. The work performed by the UAH personnel under this Delivery Order, concentrated on design and analyses of a compact coherent lidar system capable of measuring range and velocity of hard targets, and providing air mass velocity data. The following is the scope of this work. a. Investigate various laser sources and optical signal detection configurations in support of a compact and lightweight coherent laser radar to be developed for precision range and velocity measurements of hard and fuzzy targets. Through interaction with MSFC engineers, the most suitable laser source and signal detection technique that can provide a reliable compact and lightweight laser radar design will be selected. b. Analyze and specify the coherent laser radar system configuration and assist with its optical and electronic design efforts. Develop a system design including its optical layout design. Specify all optical components and provide the general requirements of the electronic subsystems including laser beam modulator and demodulator drivers, detector electronic interface, and the signal processor. c. Perform a thorough performance analysis to predict the system measurement range and accuracy. This analysis will utilize various coherent laser radar sensitivity formulations and different target models.

Amzajerdian, Farzin↗

WIND MEASUREMENTS WITH HIGH-ENERGY DOPPLER LIDAR

Coherent lidars at 2-micron wavelengths from holmium or thulium solid-state lasers have been in use to measure wind for applications in meteorology, aircraft wake vortex tracking, and turbulence detection [1,2,3] These field-deployed lidars, however, have generally been of a pulse energy of a few millijoules, limiting their range capability or restricting operation to regions of high aerosol concentration such as the atmospheric boundary layer. Technology improvements in the form of high-energy pulsed lasers, low noise detectors, and high optical quality telescopes are being evaluated to make wind measurements to long ranges or low aerosol concentrations. This research is aimed at developing lidar technology for satellite-based observation of wind on a global scale. The VALIDAR project was initiated to demonstrate a high pulse energy coherent Doppler lidar. VALIDAR gets its name from the concept of validation lidar, in that it can serve as a calibration and validation source for future airborne and spaceborne lidar missions. VALIDAR is housed within a mobile trailer for field measurements.

Koch, Grady J.↗

Measuring solar wind velocity with spacecraft phase scintillations

The measurement of spacecraft phase scintillations with a coherent dual-frequency radio system permits solar-wind velocity measurements based on multiple-station phase scintillations. Advantages of measuring solar-wind velocity on the basis of multiple-station phase scintillations are discussed with respect to amplitude scintillations. These advantages include the ability to carry out observations closer to the sun, a much wider range of possible baselines, a lower S/N ratio for long-baseline phase measurements, and a wider range of antenna sizes and receiver noise temperatures. NASA antennas particularly suitable for these measurements are identified, and observations with the coherent S/X radio system aboard various NASA spacecraft intended for deep-space missions are proposed.

Woo, R.↗

TPSAS-NF1676L-18834-DND

This presentation will give an overview of the 20-plus years of pulsed transmit laser development at NASA Langley Research Center (LaRC) to enable a coherent Doppler wind lidar to measure global winds from earth orbit. Our group at LaRC has been developing the pulsed laser and other coherent lidar technologies for the global wind mission since the late 1980s. The causal path followed has been from space mission requirements to coherent lidar requirements to component requirements to technology development and finally to ground and aircraft validation. We will describe the development and deployment of Doppler Aerosols Wind Lidar (DAWN) for airborne measurement of wind velocity and direction. The will also present the status of ongoing fully conductively-cooled 2-micron wind lidar transmitter for NASA 3-D winds mission.

Upendra N Singh↗