Status of NASA's Stirling space power converter program

An overview is presented of the NASA free-piston stirling space power converter technology program. The authors discuss Stirling experience in space and progress toward 1050 K and 1300 K Stirling space power converters. Fabrication is nearly completed for the 1050 K component test power converter (CTPC); results of motoring tests of the cold end (525 K), are presented. The success of these and future designs is dependent upon supporting research and technology efforts including heat pipes, bearings, superalloy joining technologies, high efficiency alternators, life and reliability testing and predictive methodologies. The authors provide an update of progress in some of these technologies.

Dudenhoefer, James E.↗

Description of a pressure measurement technique for obtaining surface static pressures of a radial turbine

The aerodynamic performance of a solid uncooled version of a cooled radial turbine was evaluated in the Small Engine Components Test Facility Turbine rig at the NASA Lewis Research Center. Specifically, an experiment was conducted to rotor surface static pressures. This was the first time surface static pressures had been measured on a radial turbine at NASA Lewis. These pressures were measured by a modified Rotating Data Package (RDP), a standard product manufactured by Scanivalve, Inc. Described here are the RDP, and the modifications that were made, as well as the checkout, installation, and testing procedures. The data presented are compared to analytical results obtained from NASA's MERIDL TSONIC BLAYER (MTSB) code.

Dicicco, L. D.↗

A phase one AR/C system design

The Phase One AR&C System Design integrates an evolutionary design based on the legacy of previous mission successes, flight tested components from manned Rendezvous and Proximity Operations (RPO) space programs, and additional AR&C components validated using proven methods. The Phase One system has a modular, open architecture with the standardized interfaces proposed for Space Station Freedom system architecture.

Kachmar, Peter M.↗

In-step Two-phase Flow (TPF) Thermal Control Experiment

The Two-Phase Flow Thermal Control Experiment is part of the NASA/OAST In-Space Technology Experiments (In-STEP) Program. The experiment is configured for the Hitchhiker Shuttle payload system and consists of a capillary pumped loop, heatpipe radiator, and two-phase flow heat exchanger. The flight experiment design approach, test plan, payload design, and test components are described in outline and graphic form.

Source record↗

A practical approach to determining the uncertainty of a pressure measurement system

The pressure measurement systems located at three propulsion component test stands at the Marshall Space Flight Center (MSFC) were evaluated for their specific measurement uncertainty levels. An elemental error source evaluation was performed to provide an analytical estimate of uncertainty. Applied loads tests were also conducted at the different MSFC test sites to derive an empirical estimate of uncertainty for the measurement system process. The analytical results are compared to those obtained empirically. The data from MFSC was also compared to data reported from other comparable test facilities. Methods for acquiring and processing the data from calibration, acquisition, and reduction error sources are also addressed.

Fish, James E.↗

John C. Stennis Space Center Overview

An overview of research being conducted at the John C. Stennis Space Center is given. The Space Center is not only a NASA Space Flight Center, but also houses facilities for 22 other governmental agencies. The programs described are Stennis' High Heat Flux Facility, the Component Test Facility (used to test propulsion rockets and for the development of the National Aerospace Plane), oceanographic and remote sensing research, and contributions to the development of Space Station Freedom.

Source record↗

Aerospace applications of magnetic bearings

Magnetic bearings have traditionally been considered for use in aerospace applications only where performance advantages have been the primary, if not only, consideration. Conventional wisdom has been that magnetic bearings have certain performance advantages which must be traded off against increased weight, volume, electric power consumption, and system complexity. These perceptions have hampered the use of magnetic bearings in many aerospace applications because weight, volume, and power are almost always primary considerations. This paper will review progress on several active aerospace magnetic bearings programs at SatCon Technology Corporation. The magnetic bearing programs at SatCon cover a broad spectrum of applications including: a magnetically-suspended spacecraft integrated power and attitude control system (IPACS), a magnetically-suspended momentum wheel, magnetic bearings for the gas generator rotor of a turboshaft engine, a vibration-attenuating magnetic bearing system for an airborne telescope, and magnetic bearings for the compressor of a space-rated heat pump system. The emphasis of these programs is to develop magnetic bearing technologies to the point where magnetic bearings can be truly useful, reliable, and well tested components for the aerospace community.

Downer, James↗

Design of scaled down structural models

In the aircraft industry, full scale and large component testing is a very necessary, time consuming, and expensive process. It is essential to find ways by which this process can be minimized without loss of reliability. One possible alternative is the use of scaled down models in testing and use of the model test results in order to predict the behavior of the larger system, referred to herein as prototype. This viewgraph presentation provides justifications and motivation for the research study, and it describes the necessary conditions (similarity conditions) for two structural systems to be structurally similar with similar behavioral response. Similarity conditions provide the relationship between a scaled down model and its prototype. Thus, scaled down models can be used to predict the behavior of the prototype by extrapolating their experimental data. Since satisfying all similarity conditions simultaneously is in most cases impractical, distorted models with partial similarity can be employed. Establishment of similarity conditions, based on the direct use of the governing equations, is discussed and their use in the design of models is presented. Examples include the use of models for the analysis of cylindrical bending of orthotropic laminated beam plates, of buckling of symmetric laminated rectangular plates subjected to uniform uniaxial compression and shear, applied individually, and of vibrational response of the same rectangular plates. Extensions and future tasks are also described.

Simitses, George J.↗

Non-intrusive measurements in a rocket engine combustor

In recent years analytical tools to characterize combustor flow have been developed in order to support design. To facilitate anchoring of combustion related physical models and the CFD codes in which they are incorporated, considerable development and application of non-intrusive combustion diagnostic capabilities has occurred. Raman spectroscopy can be used to simultaneously detect all polyatomic molecules present in significant concentrations and to determine gas temperature. This is because all molecules possess a distinct temperature dependent Raman spectrum. A multi-point diagnostic system for non-intrusive temperature and species profiling in rocket engines has been developed at Rocketdyne. In the present effort, the system has been undergoing validation for application to rocket engine component testing. A 4 inch diameter windowed combustor with a coaxial gas-gas injector was chosen for this series of validation experiments. Initially an excimer-pumped tunable dye laser and later a solid state Nd-Yag laser served as excitation sources. The Raman signal was dispersed by a monochromator and detected by a gated, intensified Charged Coupled Device (CCD) array. Experiments were carried out prior to each series of hot fire tests to ensure that the Raman signal detected was due to a spontaneous rather than a stimulated Raman emission process. Over sixty hot fire tests were conducted during the first series of tests with the excimer/dye laser. All hot fire testing was at a mixture ratio of 0.5 and chamber pressures of approximately 100 and approximately 300 psia. The Raman spectra of hydrogen, water vapor and oxygen recorded during single element hot fire tests were reduced and analyzed. A significant achievement was the attainment of single shot Raman spectra in cold flow tests. Unfortunately, the single shot signal-to-noise ratio deteriorated to an unacceptable level during the hot fire testing. Attempts to obtain temperature data from the hydrogen Q1-branch profiles obtained in hot fire tests suggest that potentially complicating factors may render the approach of averaging data on the photodiode array invalid. A second series of hot fire tests was conducted with a 4 element coaxial injector using the Nd-Yag laser. A very compact and portable diagnostics set up was assembled for ease of alignment, relocation and flexibility. Measurements were made at several regions in the chamber in order to map concentration profiles. High spatial resolution and improved signal to noise characteristics were demonstrated.

Farhangi, S.↗

Aerodynamic Evaluation of Two Compact Radial-Inflow Turbine Rotors

The aerodynamic evaluation of two highly loaded compact radial turbine rotors was conducted at the NASA Lewis Research Center Small Engine Component Test Facility (SECTF). The experimental results were used for proof-of-concept, for modeling radial inflow turbine rotors, and for providing data for code verification. Two rotors were designed to have a shorter axial length, up to a 10-percent reduced diameter, a lighter weight, and equal or higher efficiencies with those of conventional radial inflow turbine rotors. Three configurations were tested: rotor 1, having a 40-percent shorter axial length, with the design stator (stator 1); rotor 1 with the design stator vanes closed down (stator 2); and rotor 2, slightly shorter axially and having higher loading, with stator 2. The stator had 36 vanes and the rotors each had 14 solid blades. Although presently uncooled, the rotor blades were designed for thicknesses which would allow cooling passages to be added. The overall stage performance measurements and the rotor and stator exit flow field surveys were obtained. Measurements of steady state temperatures, pressures, mass flow rates, flow angles, and output power were made at various operating conditions. Data were obtained at corrected speeds of 80, 90, 100, 110, and 120 percent of design over a range of equivalent inlet-to-exit pressure ratios of 3.5, 4.0, 4.5, and 5.0, the maximum pressure ratio achieved. The test showed that the configuration of rotor 1 with stator 1 running at the design pressure ratio produced a flow rate which was 5.6 percent higher than expected. This result indicated the need to close down the stator flow area to reduce the flow. The flow area reduction was accomplished by restaggering the vanes. Rotor 1 was retested with the closed-down stator vanes and achieved the correct mass flow. Rotor 2 was tested only with the restaggered vanes. The test results of the three turbine configurations were nearly identical. Although the measured efficiencies of the compact designs fell 2 to 3 points below the predicted efficiency of 91 percent, they did meet and exceed by up to 2.5 percentage points the efficiences of state-of-the-art turbines found in the literature.

Simonyi, P. Susan↗

Low Temperature Characterization of Ceramic and Film Power Capacitors

Among the key requirements for advanced electronic systems is the ability to withstand harsh environments while maintaining reliable and efficient operation. Exposures to low temperature as well as high temperature constitute such stresses. Applications where low temperatures are encountered include deep space missions, medical imaging equipment, and cryogenic instrumentation. Efforts were taken to design and develop power capacitors capable of wide temperature operation. In this work, ceramic and film power capacitors were developed and characterized as a function of temperature from 20 C to -185 C in terms of their dielectric properties. These properties included capacitance stability and dielectric loss in the frequency range of 50 Hz to 100 kHz. DC leakage current measurements were also performed on the capacitors. The manuscript presents the results that indicate good operational characteristic behavior and stability of the components tested at low temperatures.

Hammoud, Ahmad↗

A Proof of Concept Experiment for Reducing Skin Friction by Using a Micro-Blowing Technique

A proof of concept experiment for reducing skin friction has been conducted in the Advanced Nozzle and Engine Components Test Facility at the NASA Lewis Research Center. In this unique concept, called the micro-blowing technique (MBT), an extremely small amount of air was blown vertically through very small holes to reduce the surface roughness and to control the gradient of the flow velocity profile on the surface thereby reducing skin friction. Research revealed that the skin was the most important factor to make this concept achievable. The proposed skin consisted of two layers. The inner layer was a low permeable porous skin for distributing the blowing air evenly while the outer layer with small holes controlled the vertical or nearly vertical blowing air. Preliminary experimental results showed that the MBT has the potential of a very large reduction in skin friction below the skin friction of a nonporous plain flat plate. Of the skins tested, three have been identified as the MBT skins. They provided very low unblown skin friction such that a large skin friction reduction, below a flat plate value, was achieved with very small amounts of blowing air. The reduction in skin friction of 55 percent was achieved at the Mach number of 0.3 for the exhaust pressure of 0.85 atm, and 60 percent reduction was obtained for the exhaust pressure of 0.24 atm (corresponding to 10 700-m altitude) at the same Mach number. A significant reduction in skin friction of over 25 percent was achieved for the exhaust pressure of 0.24 atm at the Mach number of 0.7. This implied that the MBT could be applied to a wide range of flight conditions. It is also believed that additional 10 percent reduction could be obtained by eliminating the gap between the inner layer and the outer layer. The aspect ratio of the vertical small holes for the outer layer of the MBT skin should be larger than 4 based on the preliminary conclusion from this test. Many experiments are needed to find out the optimal MBT skin. The penalty associated with the MBT needs to be assessed. However, preliminary results indicated that the MBT could provide a 25 to 35 percent reduction for real-world application. The concept can be applied to not only an airplane, but also a missile, a submarine (micro-blow water instead of air), and an ocean liner.

Hwang, Danny P.↗

Experimental Evaluation of the Penalty Associated With Micro-Blowing for Reducing Skin Friction

A micro-blowing technique (MBT) experiment was conducted in the Advanced Nozzle and Engine Components Test Facility at the NASA Lewis Research Center. The objectives of the test were to evaluate the pressure-drag penalty associated with the MBT and to provide additional information about the porous plates used for micro-blowing. The results showed that 1 of 12 plates tested could reduce the total drag (skin-friction drag plus pressure drag) below a solid flat plate value. The results of this experiment and prior data showed that a total drag reduction below a solid flat plate value was possible. More tests are needed to find an optimal MBT skin and to find a technique to reduce pressure drag.

Hwang, Danny P.↗

Virtual Build: Low-Tech Simulations Can Be High on IPPD Content

After two years of design, component testing, and parts fabrication, the project team was within months of starting assembly on the first major elements of a new product assembly. Schedules were extremely tight and there was no room for error in the first unit build-up for test. The first draft of the assembly drawing was nearing completion and needed to be approved by key members of the Integrated Product Team (IPT) before release. Only then could the manufacturing planning be finalized and released for assembly to begin. What could we do to improve the quality of our first build effort? How could we minimize all the changes inherent in the first-time build of a complex mechanical system? Why not a dress rehearsal of the build process with all the participating players, hardware, and build documentation? A "virtual build simulation". In an organization employing integrated product teams there is no substitute for clear communication between the various cross-functional members. Despite team collocation, integrated solid modeling, and frequent coordination meetings. elements of the product-process design can still slip through the cracks and show up on the assembly floor. The virtual build exercise was designed to provide one intensive hands-on experience for all members of the design and assembly team in time to make corrections without schedule impact.

Hilscher, Rick↗

MC-1 LOX Pump Rotating Cavitation: Issue and Investigation

Leading edge tip deformation was noted on the LOX inducer from the component test unit at disassembly. The damage was in a location similar to a previous Fastrac water flow inducer failure. A team was formed to investigate the anomaly.

VanHooser, Katherine↗

Adjustable Focus Optical Correction Lens (AFOCL)

This report describes a metrology plan that was developed for the characterization of PLZT-based devices, such as the Adjustable Focus Optical Correction Lens (AFOCL) in support of and as part of the deliverables for NASA contract NAS8-00118. The areas to be investigated include intensiometric effects (those that limit or alter the intensity of the light transmitted through the optic); interferometric effects (the phase change induced through the optic); and polarimetric effects (evaluating the differential lag between two polarization states propagating through the optic). These distinct phenomena are often coupled together in real applications consequently, there is a need to develop different standardized testing apparatus to: (1) isolate one effect from another; (2) gather information for understanding the physical effects; (3) anchor wavefront corrector modeling efforts; (4) develop the ability to decouple different effects; (5) demonstrate the suitability of PLZT technology to perform wavefront correction. The Center for Applied Optics (CAO) at the University of Alabama in Huntsville (UAH) is skilled in the characterization of transmission wavefront shaping devices using traditional interferometers available within the CAO Optical Metrology Laboratory and their Advanced Polarization Test Facility. Besides the imaging and interferometers available, the polarimetry facility has at its disposal, a Mueller Matrix Imaging Polarimeter (MMIP) which is well suited to the characterization of SLMs, polarizers, and thin film coatings within the visible and near-IR spectrums. In addition, the phase-shifting interferometry facilities at NASA-MSFC and the unique interferometers they processes are some of the most advanced available and may be of value especially for performing real-time optical performance evaluation of AFOCL test components.

Peters, Bruce R.↗

Piping Connector

In Stennis Space Center's Component Test Facility, piping lines carry rocket propellants and high pressure cryogenic fuels. When the lines are chilled to a pretest temperature of 400 degrees below zero, ordinary piping connectors can leak. Under contract to Stennis, Reflange, Inc. developed the T-Con connector, which included a secondary seal that tolerates severe temperature change. Because of the limited need for the large and expensive T-Con product, Reflange also developed the less costly E-Con, a smaller more compact design with the same technical advantages as the T-Con.

Source record↗

Piping Connector

A complex of high pressure piping at Stennis Space Center carries rocket propellants and other fluids/gases through the Center's Component Test Facility. Conventional clamped connectors tend to leak when propellant lines are chilled to extremely low temperatures. Reflange, Inc. customized an existing piping connector to include a secondary seal more tolerant of severe thermal gradients for Stennis. The T-Con connector solved the problem, and the company is now marketing a commercial version that permits testing, monitoring or collecting any emissions that may escape the primary seal during severe thermal transition.