Search NASA⌕ Search

SEARCH · Search NASA

Results for “control simulation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Impact Studies and Cooperative Voltage Control for High PV Penetration

The drastically increasing penetration of photovoltaic (PV) has posed tremendous challenges in operation, control, and protection in distribution networks. The over-voltage issue is one of major concerns for extremely high PV penetration (e.g. 100%). It is critical to identify the most sensitive locations to high PV penetration and apply effective methods to mitigate the over-voltage issue. This paper introduced a novel greedy search algorithm to locate worst-case scenarios of over-voltage in both distributed and centralized PV configurations, as well as a cooperative voltage control method to mitigate over-voltage. The search algorithm has the computational advantage over existing stochastic approach and provides more insights in impact studies. The cooperative control method relies upon reactive power compensation to converge system voltage to a predefined value within standard limits. Moreover, a clustering strategy is applied to divide the network into several clusters, within which all nodes share information with neighboring nodes following a scalable communication architecture. The control algorithms and communication hierarchies presented in this paper have been implemented into OpenDSS to form the Multi Agent (MA) OpenDSS package, which has been made available to the reader. The effectiveness of developed methods are demonstrated through simulation studies on the IEEE 123-node test feeder under four different load levels.

Cooperative control↗

Innovative Patient Room Lighting System with Integrated Spectrally Adaptive Control

In December of 2013, the U.S. Department of Energy’s SSL R&D Program released a Funding Opportunity Announcement (FOA), that for the first time, contained opportunities for comprehensive application-specific system development. The FOA included opportunities for two applications, one of which was a Patient Room. Philips Lighting Research North America, submitted a proposal for the Patient Room application, and was selected for the complete project award. The award amount was for $497,127, with a Philips Research co-funding commitment 165,709 dollars. The total project value was 662,836 dollars. This project sought to redefine lighting for the patient room application. The goal was to deliver an innovative LED patient suite (patient room and bathroom) lighting system solution that was 40% more energy-efficient than traditional fluorescent incumbent technologies, and would meet all the visual and non-visual needs of patients, caregivers and visitors, and improve the patient experience. State-of-the-art multichannel LED platforms and control technologies that would provide spectral tuning and become part of an intelligent, connected lighting system drove the solution. The project was scoped into four main task areas that included a) System Concept Creation, b) Identification of the Luminaire Portfolio, c) Development of the Connected Lighting Infrastructure, and d) System Performance Validation. Each of the four main tasks were completed and validated extensively over the course the 2 ½ year project. The system concept was created by first developing a lighting design that demonstrated best practices for patient room lighting – illuminance and uniformity for task performance, reduced glare, and convenient controls, in addition to giving patients control over the lighting in their environment. A framework was defined to deliver circadian support via software behaviors. Through that process luminaires were identified from the Philips portfolio that were adaptable – by their form, dimensions, and optical materials – to mix multicolor LED platforms uniformly and deliver target design lumen levels. The Blue Sky luminaire was selected for the patient bed area to give the illusion of skylight while providing white light on the patient bed. Luminaires used existing 2-channel tunable white LED boards, and newly developed 4-channel LED boards. Red-Orange, Blue, Green, and Blue-shifted Yellow LED chips were selected based on spectral characteristics and their ability to produce high quality white light. 4-channel Power over Ethernet (PoE) drivers were developed and firmware written so they would communicate with both 2- and 4-channel boards. These components formed the backbone of the connected lighting infrastructure. Software, flexible and nuanced in its complexity, was written to set behaviors for myriad lighting scenes in the room throughout the 24 hour day – and all could be overridden by manual controls. This included a dynamic tunable white program, three color changing automatic programs that simulated degrees of sunrise to sunset palettes, and an amber night lighting system that offered visual cues for postural stability to minimize the risk of falls. All programs were carefully designed to provide visual comfort for all occupants, support critical task performance for staff, and to support the patient’s 24hr rhythms. A full scale mockup room was constructed in the Philips Cambridge Lab. The lighting system was installed, tested and functionality demonstrated to ensure smooth operation of system components – luminaires, drivers, PoE switches, wall controls, patient remote, and daylight and occupancy sensors. How did the system perform? It met visual criteria, confirmed by calculations, simulations and measurements in the field. It met non-visual criteria, confirmed by setting circadian stimulus (CS) targets and performing calculations using the calculator developed by the Lighting Research Center. Finally, human factors validation studies were conducted to gain insight from real end users in the healthcare profession; surveys were administered, data analyzed, and audio comments captured. The general consensus was positive, with requests to pilot the system in their hospitals. The importance of the research completed under this grant is that it allowed the exploration and development of a unique lighting system, one that would deliver a blend of visual and non-visual criteria in patient room design for today’s healthcare environment. The research investigated the area of multichannel LED technology, multichannel Power over Ethernet (PoE) drivers and their integration with automatic and manual controls as a system – uncovering and meeting challenges along the way. It married visual needs of patients and staff with support for 24 hour rhythms, placing value on the wellbeing of the patient – while successfully saving energy over incumbent technologies. Indications are that the market is ready and willing to invest – multiple healthcare facilities are in line to pilot this system, recognizing its value beyond energy to patient and staff well-being. Its value to the public can best be expressed by a patient support coordinator who, after spending several hours in the room being immersed in the lighting, analyzing all its features, commented: “This re-writes lighting for healthcare”.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long–short-term memory encoder–decoder with regularized hidden dynamics for fault detection in industrial processes

The ability of recurrent neural networks (RNN) to model nonlinear dynamics of high dimensional process data has enabled data-driven RNN-based fault detection algorithms. Previous studies have focused on detecting faults by identifying the discrepancies in data distribution between the faulty and normal data, as reflected in prediction errors generated by RNN models. However, in industrial processes, variations in data distribution can also result from changes in normal control setpoints and compensatory control adjustments in response to disturbances, making it hard to differentiate between normal and faulty conditions. This paper proposes a fault detection method utilizing a long short-term memory (LSTM) encoder–decoder structure with regularized hidden dynamics and reversible instance normalization (RevIN) to compactly represent high-dimensional measurements for effective monitoring. During training, the hidden states of the model are regularized to form a low-dimensional latent space representation of the original multivariate time series data. As a result, the prediction errors of the latent states can be used to monitor the abnormal dynamic variations, while the reconstruction errors of the measured variables are used to monitor the abnormal static variations. Furthermore, the proposed indices can reflect operating conditions, even when the distribution of test data changes, which helps distinguish faults from normal adjustments and disturbances that controllers can settle. Here, data from numerical simulation and the Tennessee Eastman process are used to illustrate the effectiveness of the proposed fault detection method.

42 ENGINEERING↗

Self-welding of Inconel 617 under high-pressure-high-temperature conditions for nuclear reactors

In response to continuously declining availability of fossil fuels, nuclear power has become an important alternative source of power generation. Growing application of nuclear power has relieved the shortage of electricity. However, it is also accompanied with new drawbacks, such as radioactive waste, and potential catastrophic consequences in case of major accidents. For nuclear power plants, severe accidents mostly originate from the reactor, making the reliability of the reactor of paramount importance to the overall safety of a nuclear power plant. Massive heat generation through nuclear fission/fusion and heat exchange render the whole reactor operating at extremely high temperatures (i.e., 900–1000 °C), which, in conjunction with large load from subsystems/ components made of special heavy alloys, renders the reactor under the risk of self-welding, a phenomenon that could lead to strong bonding between components and paralyze the operability of the nuclear reactor. This paper investigates the self-welding behavior of Inconel 617, a primary candidate nickel alloy for key components of the next generation gas cooled nuclear plant, inside a controlled atmospheric furnace with preset static load, simulating the high-pressure high-temperature conditions inside nuclear reactors. Therefore, test results show that Inconel 617 experiences self-welding through common oxide zone at the interface, and it has remarkable bonding strength, requiring 4114 N (57.15 MPa) and 4338 N (60.25 MPa) to break apart a mated sample pair, under an apparent contact pressure of 0.341 MPa after 50-h aging, in helium and air atmospheres, respectively. The higher oxygen presence in air results in slightly stronger oxide bond at the interface, compared to helium, and the bond strength increases with dwell time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Longitudinal train dynamics model for a rail transit simulation system

The paper develops a longitudinal train dynamics model in support of microscopic railway transportation simulation. The model can be calibrated without any mechanical data making it ideal for implementation in transportation simulators. The calibration and validation work is based on data collected from the Portland light rail train fleet. The calibration procedure is mathematically formulated as a constrained non-linear optimization problem. The validity of the model is assessed by comparing instantaneous model predictions against field observations, and also evaluated in the domains of acceleration/deceleration versus speed and acceleration/deceleration versus distance. A test is conducted to investigate the adequacy of the model in simulation implementation. The results demonstrate that the proposed model can adequately capture instantaneous train dynamics, and provides good performance in the simulation test. Thus, the model provides a simple theoretical foundation for microscopic simulators and will significantly support the planning, management and control of railway transportation systems.

42 ENGINEERING↗

Impact of carbonation on leaching of constituents from a cementitious waste form for treatment of low activity waste at the DOE Hanford site

Carbonation can be a major aging process during disposal of alkaline cementitious waste forms and can impact constituent leaching by changes in material alkalinity, pore structure, and controlling mineral phases. The effect of carbonation on the leaching of major and trace constituents from Cast Stone, a cementitious waste form developed to treat high salt content low activity waste, was studied through a combination of leaching experiments and reactive transport simulations. Diffusive transport of constituents in the waste form was evaluated using reactive transport modeling of diffusion-controlled leaching test results and a geochemical speciation model derived from pH-dependent leaching. Comparisons between Cast Stone materials aged under nitrogen, air, and 2% carbon dioxide in nitrogen showed that carbonation impacts solubility, physical retention and observed diffusivity of major and trace constituents. Carbonation under 2% CO 2 decreased the diffusion-controlled leaching of chromium by two orders of magnitude. Finally, modeling results suggest that carbonation may also decrease solubility of technetium while changes to microstructure by carbonation increases effective diffusivity of constituents in Cast Stone.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Towards fast and accurate predictions of radio frequency power deposition and current profile via data-driven modelling: applications to lower hybrid current drive

Three machine learning techniques (multilayer perceptron, random forest and Gaussian process) provide fast surrogate models for lower hybrid current drive (LHCD) simulations. A single GENRAY/CQL3D simulation without radial diffusion of fast electrons requires several minutes of wall-clock time to complete, which is acceptable for many purposes, but too slow for integrated modelling and real-time control applications. The machine learning models use a database of more than 16 000 GENRAY/CQL3D simulations for training, validation and testing. Latin hypercube sampling methods ensure that the database covers the range of nine input parameters ( $n_{e0}$ , $T_{e0}$ , $I_p$ , $B_t$ , $R_0$ , $n_{\|}$ , $Z_{{\rm eff}}$ , $V_{{\rm loop}}$ and $P_{{\rm LHCD}}$ ) with sufficient density in all regions of parameter space. The surrogate models reduce the inference time from minutes to $\sim$ ms with high accuracy across the input parameter space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Common Mode Voltage Compensation for Capacitor Voltage Ripple Reduction of 7-kV SiC-based Modular Multilevel Converter

Abstract -Modular multilevel converters (MMCs), with the filterless and transformer-less features, are considered as a promising topology for high-efficiency medium voltage (MV) high voltage (HV) drive systems. However, a large current ripple flowing through the capacitors of each submodule will cause significant capacitor voltage fluctuation. This paper proposes a new compensation method in common mode voltage injection to further reduce the magnitude of the fundamental component in capacitor voltages. The capacitor voltage ripples are reduced significantly by using the proposed control method, which means that smaller size of capacitors can be used for same voltage ripple requirements. Simulation and experimental test results verify the proposed compensation method using a three-phase permanent magnet synchronous machine (PMSM).

Common mode voltage injection↗

Factors Influencing Building Demand Flexibility

The U.S. Department of Energy’s National Roadmap for Grid-interactive Efficient Buildings (GEB) acknowledged that building demand flexibility (DF) is both an important strategy to decarbonizing the buildings sector and an important resource for meeting the changing needs of the electrical grid such as improving grid reliability. However, understanding the complexity and uncertainties in real building field performance of DF strategies is a large gap hindering stakeholders on both grid and buildings side to make investments on deploying such strategies. The research work in this report intended to advance understanding of the variability and influential factors in building demand flexibility. Adding such knowledge based on lab testing results and measured performance data from real buildings is an important contribution. The report uses standardized metrics and methods to quantify DF performance from field-measured DF datasets of two significant building groups of big-box retail and medium office buildings to present the challenge of building DF variability in multiple dimensions. The report presents findings related to how several key factors influence building demand flexibility from implementing a common, cost-effective DF control strategy (i.e., adjusting zone temperatures). The findings are supported by full-scale lab testing, field data analysis and simulation research. The authors also provided application-oriented recommendations to stakeholders such as building aggregators, utility program design professionals, sophisticated building portfolio owners, and more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardware-in-the-loop Testing of Signal Temporal Logic Frequency Control in a Microgrid

This paper presents a hardware-in-the-loop (HITL) testing and lessons learned for a signal temporal logic (STL) frequency control in a microgrid setting. In contrast to most, if not all, traditional control mechanisms, the STL control allows for including temporal constraints in the control formulation to handle sophisticated specifications from grid codes and protection relays. This feature provides richer descriptions of control specifications to address both magnitude and time simultaneously, hence a valuable tool for power system operation and control. An ultra-low voltage (24V) HITL microgrid platform consisting of two type-3 wind turbine generators and one diesel generator is used to test the proposed STL frequency control. In experimental case studies, we demonstrate that the HITL frequency responses closely match the simulated ones and strictly satisfy the designed STL control specifications.

Ferrari Maglia, Max↗

NBSR reactor control room upgrade - 215

The maintenance and modernization of the National Institute of Standards and Technology (NIST) Center for Neutron Research (NCNR) reactor, known as the NBSR, is an ongoing process to endure until the eventual decommissioning of the reactor. As part of the renovation effort, the reactor control system is to be upgraded. Following some initial outsourcing efforts, the NBSR reactor control system upgrade has been restructured to be implemented by in-house means. The beginning stage of the upgrade involved the development of a simulator environment based on a PC system and digitization of the majority of nuclear reactor monitoring data. The NBSR reactor surveillance data consists of approximately thirteen hundred input/output points, including analog/digital sensor signals, signal conditioners, and relay logic. The aim of the current phase is to implement a new reactor data acquisition and display system (RDS) and lay out the infrastructure for the upgrade of the reactor control system (RCS). Key design criteria are to implement a reliable, redundant, diverse, modular and candid system where any complex digital manipulations are taken outside of the control room. Basically, the data analytics and custom codes are separated from reactor operation control and decision making logic. Furthermore, the new RDS is designed such that it could be maintained internally by NCNR personnel. The RDS is unique in design and modularity, minimizing custom codes and testing, making it ideal for research reactors. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Model-Predictive Hierarchical-Control Framework for Aggregating Residential DERs to Provide Grid Regulation Services: Preprint

This paper develops a hierarchical control fram-ework to aggregate and control behind-the-meter distributed energy resources (DERs), which will be ubiquitous in future distribution systems. Even though the increasing penetration of DERs will strain the power networks in terms of voltage regul-ation and coordination issues with existing transmission-level conventional generators, the distribution-level DERs can also be utilized to help provide flexibility to the power network while providing cost savings to the DER owners. Therefore, this paper develops a model-predictive control strategy to determine the available power flexibility, and to utilize the flexibility in an aggregated form to provide grid regulation services. Numerical simulations performed on the IEEE 37-bus test system demonstrate the efficacy of the proposed approach.

14 SOLAR ENERGY↗

Hybrid Heavy Duty Diesel Powertrain for Off-Road Applications (Final Technical/Scientific Report)

In this program, a heavy-duty hybrid powersystem, consisting of a 30% downsized diesel engine and a front-end accessory drive (FEAD) incorporating a high-speed flywheel (HSFW) energy storage system, a mechanical-drive turbocharger (SuperTurbo), and motor-generator units (MGU) was developed and demonstrated. The high efficiency core 13L engine coupled with the hybrid elements was physically validated across various off-road machine and transient work cycles with the ultimate goal of demonstrating 17% efficiency improvement with equivalent transient response as the 18L diesel engine this concept powersystem would replace. The project culminated in a physical demonstration of the high-efficiency powersystem in a high-capability test cell with the engine, all the hybrid devices, controls, and required performance and emissions measurements. Based on the combination of physical validation and rigorous system simulation, the following program conclusions may be drawn: (1) The developed hybrid H2D2 powersystem demonstrated a range of efficiency improvement of 10.5 - 25.6%, with a midpoint of 17.9%; (2) Transient load response on; (3) The HSFW system was validated to achieve peak assisting of 110kW at 12,000 Nm/sec ramp rates; (4) The powersystem was validated to be capable of meeting U.S. EPA Tier 4 Final off-road emissions through transient NRTC testing; (5) A Total Cost of Ownership (TCO) analysis and found that the core 13L engine would pay back immediately (adoption of start/stop would pay back in less than one year, and the full hybrid system payback was three years.)

33 ADVANCED PROPULSION SYSTEMS↗

Experimental and computational study of phase space dynamics in strongly coupled plasmas with steep density gradients

Understanding how plasmas thermalize when density gradients are steep remains a fundamental challenge in plasma physics, with direct implications for fusion experiments and astrophysical phenomena. Standard hydrodynamic models break down in these regimes, and kinetic theories make predictions that have never been directly tested. Here, we present the first detailed phase-space measurements of a strongly coupled plasma as it evolves from sharp density gradients to thermal equilibrium. Using laser-induced fluorescence imaging of an ultracold calcium plasma, we track the complete ion distribution function f(x,v,t). We discover that commonly used kinetic models (Bhatnagar–Gross–Krook and Lenard–Bernstein) overpredict thermalization rates, even while correctly capturing the initial counterstreaming plasma formation. Our measurements reveal that the initial ion acceleration response scales linearly with electron temperature, and that the simulations underpredict the initial ion response. In our geometry we demonstrate the formation of well-controlled counterpropagating plasma beams. This experimental platform enables precision tests of kinetic theories and opens new possibilities for studying plasma stopping power and flow-induced instabilities in strongly coupled systems.

Bergeson, Scott (ORCID:0000000231249226)↗

Evaluations of Silica Aerogel-Based Flexible Blanket as Passive Thermal Control Element for Spacecraft Applications

The feasibility of utilizing commercially available silica aerogel-based flexible composite blankets as passive thermal control element in applications such as extraterrestrial environments is investigated. Differential scanning calorimetry showed that aerogel blanket was thermally stable over – 150 to 126 °C. The outgassing behavior, e.g., total mass loss, collected volatile condensable materials, water vapor regained and recovered mass loss, was within acceptable range recommended for the space applications. ASTM tension and tear tests confirmed the material’s mechanical integrity. The thermo-optical properties remained nearly unaltered in simulated space environmental tests such as relative humidity, thermal cycling and thermo-vacuum tests and confirmed the space worthiness of the aerogel. Aluminized Kapton stitched or anchored to the blanket could be used to control the optical transparency of the aerogel. These outcomes highlight the potential of commercial aerogel composite blankets as passive thermal control element in spacecraft. Structural and chemical characterization of the material was also done using scanning electron microscopy, Fourier transform infrared spectroscopy and x-ray photoelectron spectroscopy.

36 MATERIALS SCIENCE↗

Latent Neural ODE for Integrating Multi-Timescale Measurements in Smart Distribution Grids

Under a smart grid paradigm, there has been an increase in sensor installations to enhance situational awareness. The measurements from these sensors can be leveraged for real-time monitoring, control, and protection. However, these measurements are typically irregularly sampled. These measure-ments may also be intermittent due to communication bandwidth limitations. To tackle this problem, this paper proposes a novel latent neural ordinary differential equations (LODE) approach to aggregate the unevenly sampled multivariate time-series measurements. The proposed approach is flexible in performing both imputations and predictions while being computationally efficient. Simulation results on IEEE 37 bus test systems illustrate the efficiency of the proposed approach.

multi time-scale measurements↗

Silicon Dioxide Deposited Using Atmospheric Pressure Plasma Chemical Vapor Deposition for Improved Adhesion and Water Intrusion Resistance for Lightweight Manufacturing

This work aims to demonstrate the barrier coating, and adhesion promoting properties of silica-based coatings deposited using an atmospheric pressure plasma torch (APPT). This is achieved by applying an industrial grade adhesive to silica thin films deposited, on the surfaces to be joined, using atmospheric pressure plasma chemical vapor deposition (APP-CVD), to make single joint lap shear samples of different metal combinations commonly found in lightweight manufacturing such as aluminum and magnesium as well as steel. To deposit these thin films, two separate silicon based organic precursors, hexamethyldisiloxane (HMDSO), and tetraehylorthosilicate (TEOS), are used. Here, samples are bonded using DuPont Betamate 1486 adhesive, and the lap shear results for these films are compared to the lap shear results of a chemically cleaned control using the same adhesive. The APPT uses a microwave power supply and gas mixtures of N 2 and Ar. The adhesion of the films are tested using lap shear, and elevated temperature water soaks are conducted on the joints as well to simulate environmental exposure. Lap shear results from samples with silica thin films max shear stress are 25%-115% increase compared to control samples depending on material. After exposure to water soak the max shear strength of the joints decreased by less than 15%, which demonstrates the films capabilities as a water barrier. Film morphology is examined using Scanning Electron Microscopy (SEM), and the film’s composition and approximate thickness are obtained using Rutherford Backscattering Spectroscopy (RBS).

36 MATERIALS SCIENCE↗

SAS4A/SASSYS-1 Validation with EBR-II Tests Performed During the SHRT Testing Program (Rev. 2)

The EBR-II sodium-cooled fast reactor supported a wide range of fast reactor research activities. The final fifteen years of operations at EBR-II were used for experiments and tests to demonstrate the importance of passive safety in liquid metal reactors and the capability of such systems to provide strong passive responses during off-normal conditions. The Shutdown Heat Removal Test program at EBR-II provided test data supporting the validation of computer codes for design, licensing, and operation of LMRs, among other objectives. The program included nearly sixty tests, most of which were protected and unprotected loss of flow and loss of heat sink tests run at various initial powers and flow rates. This report documents the results of modeling and simulation of tests from the Shutdown Heat Removal Test program to support validation of Argonne’s SAS4A/SASSYS-1 fast reactor safety analysis code. SHRT-17 and SHRT-6 were protected loss of flow tests where a loss of electrical power to all sodium coolant pumps was simulated to demonstrate the effectiveness of natural circulation cooling characteristics. SHRT-45R, SHRT-39, and SHRT-43R were unprotected loss of flow tests where the control rod scram function of the plant protection system was disabled to demonstrate the effectiveness of EBR-II’s passive reactivity feedbacks. BOP-301 and BOP-302R were unprotected loss of heat sink tests that demonstrated how reactivity feedback effects driven by changes to the core inlet temperature can shut down the fission process. PICT-5/6 demonstrated how core power could be increased and decreased via changes in the intermediate sodium and feedwater flow rates. This validation activity leverages modeling and simulation efforts that originated under an International Atomic Energy Agency Coordinated Research Project for benchmark analysis of the EBR-II Shutdown Heat Removal Tests. The SAS4A/SASSYS-1 models originally developed for the CRP have been modernized to utilize new code features and modeling practices. Differences between the predicted and measured test data were explored and the causes of these differences were identified as being due to modeling approximations, uncertainty in transient component behavior, and instrumentation uncertainties. Overall, it was concluded that for all tests simulated there was good agreement between the flow, power, and temperature predictions and the measured data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗