Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogen”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Autogenous Pressurization of a Cryogenic Tank Using Computational Fluid Dynamics

Well-validated simulation tools can be used to predict long-term storage and transfer of cryogenic propellants, which are essential to NASA’s mission plan to return to the Moon and continue to Mars. Autogenous pressurization of propellant tanks is used to supply rocket engine turbopumps with pressurized liquid fuel and oxidizer, preventing cavitation. Additionally, autogenous pressurization can be used to pressurize propellant tanks to support on-orbit propellant transfer. In lieu of expensive tests conducted on-orbit, accurate predictive computational models of these processes can be used to reduce system and propellant mass as well as mission risk. Using simulation tools also reduces the cost of analyzing and developing this technology. This study presents a multiphase computational fluid dynamics model capable of simulating autogenous pressurization of a large cryogenic tank using the commercial code STAR-CCM+. Experimental data from a full-scale tank pressurization test under terrestrial gravity is compared to simulation results using transient error metrics. Comparisons show good agreement and give confidence in using these and other validated simulation tools to develop cryogenic pressurization systems.

Cryogenics↗

Autogenous Pressurization of a Cryogenic Tank using Computational Fluid Dynamics

Well-validated simulation tools can be used to predict long-term storage and transfer of cryogenic propellants, which are essential to NASA’s mission plan to return to the Moon and continue to Mars. Autogenous pressurization of propellant tanks is used to supply rocket engine turbopumps with pressurized liquid fuel and oxidizer, preventing cavitation. Additionally, autogenous pressurization can be used to pressurize propellant tanks to support on-orbit propellant transfer. In lieu of expensive tests conducted on-orbit, accurate predictive computational models of these processes can be used to reduce system and propellant mass as well as mission risk. Using simulation tools also reduces the cost of analyzing and developing this technology. This study presents a multiphase computational fluid dynamics model capable of simulating autogenous pressurization of a large cryogenic tank using the commercial code STAR-CCM+. Experimental data from a full-scale tank pressurization test under terrestrial gravity is compared to simulation results using transient error metrics. Comparisons show good agreement and give confidence in using these and other validated simulation tools to develop cryogenic pressurization systems. Note: There is no audio file included or available for this presentation.

cryogenics↗

Design, Calibration, and Application of A Cryogenic Low-Background Infrared Radiometer for Spectral Irradiance and Radiance Measurements From 4- to 20-μm Wavelength

We have constructed, calibrated, and tested a cryogenic low-background infrared (IR) radiometer for both spectral radiance and irradiance measurements over the 4- to 20-μm wavelength range. The primary purpose of the Missile Defense Transfer Radiometer (MDXR) is to measure absolute irradiance or radiance from cryogenic IR test chamber sources using a photoconductive Si:As blocked-impurity band (BIB) detector and a set of spectral filters. The MDXR also includes an absolute cryogenic radiometer (ACR) and a Fourier-transform spectrometer (FTS). For irradiance measurements, the ACR is used to provide the primary power scale for the BIB detector in conjunction with spectral filters, whereas the FTS/BIB configuration derives its scale from an internal blackbody source. The two measurement scales show agreement for the irradiance of highly collimated (<1 mrad) IR beams from 10 -13 to 10 -8 W / μm / cm 2 within the combined relative uncertainties of 2.6% (coverage factor k = 1.) We have also calibrated the radiometer for radiance measurements using a large cavity fluid bath blackbody that overfills the spatial and angular extent of the radiometer entrance pupil. The radiometric calibration uncertainty analysis of the radiometer and its maintenance and stability are discussed.

radiometry↗

Molecular Accumulation during JWST’s Optical Telescope Cryogenic Thermal Vacuum Testing

Maintaining molecular cleanliness during the JWST’s Optical Telescope/Instrument Module (OTIS) Cryogenic Thermal Vacuum (TV) test campaign was critical to the success of its optical mission on orbit. In the thermal vacuum tests leading up to the final cryogenic test to validate the OTIS flight hardware, NASA Johnson Space Center’s (JSC’s) TV Chamber A was fully characterized for molecular contamination. It was found to contain common volatile condensable materials (VCM), including hydrocarbons, plasticizers, and silicones, all of which absorb in JWST’s infrared wavelength region. Due to the risks involved, cleaning molecular contamination from the OTIS mirrors was not an option and heating the Primary Mirror (PM) segments would have also been a risky and expensive endeavor. As a result, a monitoring process was developed and implemented during four different Pathfinder or risk reduction tests that were scheduled to occur prior to the flight hardware test. The goal was to quantify and assess the risk of molecular contamination depositing on the PM resulting from relatively warm chamber shrouds “leading” colder PM mirrors during warmup, by a margin of 10-50 Kelvin (K). This was accomplished using Cryogenic Quartz Crystal Microbalances (CQCMs), held at temperatures slightly cooler than the segments to signal the onset of contamination events. Per the JWST Contamination Control Plan (CCP)1, the total Primary Mirror molecular allocation requirement was 50 angstroms. In all tests, the results showed an average accumulated molecular contamination of <10 angstroms.

molecular, contamination, thermal vacuum, cryogeni↗

Analysis of Cryogenic Propellant Liquefaction Rates in Cooled Constant-Wall-TemperatureTanks

NASA has been focused on developing technology that would allow the production of cryogenic propellants on the Lunar and Martian surfaces. Utilizing Lunar/Martian resources, the produced gaseous propellants must first be liquefied and stored prior to use on the Moon or Mars ascent vehicle. Liquefaction of cryogenic propellants is a necessary technical development to enable NASA’s future spaceflight goals. This paper presents an overview of a proposed model for a propellant liquefaction system, and the effect of tank wall temperature and the ullage pressure control band on cryogenic propellant liquefaction rates. The propellant system was assumed to be a receiver of a gas from an In-Situ Resource Utilization (ISRU) harvester and condensed the gas by cooling the tank walls. First, the heat transfer principles pertinent to condensation are summarized, followed by an overview of the model which performed the analysis, including a summary of the Fortran algorithm implementation. The sensitivity of the condensation rate relative to varying tank wall temperatures is also discussed.

cryogenics↗

Analysis of Cryogenic Propellant Liquefaction Rates in Cooled Constant-Wall-Temperature Tanks

NASA has been focused on developing technology that would allow the production of cryogenic propellants on the Lunar and Martian surfaces. Utilizing Lunar/Martian resources, the produced gaseous propellants must first be liquefied and stored prior to use on the Moon or Mars ascent vehicle. Liquefaction of cryogenic propellant is a necessary technical development to enable NASA’s future spaceflight goals. This paper presents an overview of the effect of spacecraft propellant system parameters on cryogenic propellant liquefaction rates. The propellant system was assumed to be a receiver of a gas from an In-Situ Resource Utilization (ISRU) harvester and condensed the gas by cooling the tank walls. First, the general thermodynamic principles pertinent to condensation are summarized, followed by an overview of the model which performed the analysis, including a summary of the Fortran implementation. Comparisons between the model results and test data are discussed, as well as sensitivity of the condensation rate to various parameters.

cryogenics↗

Analysis of Cryogenic Propellant Liquefaction Rates in Cooled Constant-Wall-TemperatureTanks

NASA has been focused on developing technology that would allow the production of cryogenic propellants on the Lunar and Martian surfaces. Utilizing Lunar/Martian resources, the produced gaseous propellants must first be liquefied and stored prior to use on the Moon or Mars ascent vehicle. Liquefaction of cryogenic propellant is a necessary technical development to enable NASA’s future spaceflight goals. This paper presents an overview of the effect of spacecraft propellant system parameters on cryogenic propellant liquefaction rates. The propellant system was assumed to be a receiver of a gas from an In-Situ Resource Utilization (ISRU) harvester and condensed the gas by cooling the tank walls. First, the general thermodynamic principles pertinent to condensation are summarized, followed by an overview of the model which performed the analysis, including a summary of the Fortran implementation. Comparisons between the model results and test data are discussed, as well as sensitivity of the condensation rate to various parameters.

cryogenics↗

Single and Multi-Node Modeling of Direct, Submerged, and Self-Pressurization of A Cryogenic Propellant Tank Using Nodal Tools

The pressurization of cryogenic propellant tanks will always be an important process so long as cryogenic liquids are being considered as fuel sources or used for other in-space applications. Pressure control of the tank ullage is necessary for managing propellant flowrates to an engine or a receiver tank, and modeling of the process is used to predict the pressurant requirements and the amount of propellant boiloff. Direct ullage pressurization is the more traditional approach to tank pressurization, as the physics are straight-forward, and ample test (flight) data have been collected and analyzed over the past several decades. Submerged injection pressurization is an alternate method for tank pressurization and has been shown to reduce pressurant requirements, subcool the propellant, and reduce the risk of ullage collapse. Additionally, the pressurant gas entering the ullage is usually much colder when using the submerged pressurization approach, resulting in reduced propellant boiloff. These benefits are at the expense of vaporizing a small percentage of the propellent. Both tank pressurization methods are viable options for current and future space missions, and it is important to have the capability of analyzing the tank ullage conditions for both approaches. Our previous work has demonstrated the development of a Generalized Fluid System Simulation Program (GFSSP) model, which contains a thermodynamic equilibrium heat and mass transfer subroutine capable of effectively analyzing both direct and submerged pressurization systems [1-2]. This subroutine has most recently been enhanced to include the non-equilibrium effect of pressurant dissolution into the propellant. To date the ullage has always been represented as a single node, and although the simulated single-node temperatures have good comparison with the volume-averaged ullage temperatures computed from test data, the physics of the thermal stratification in the ullage were never captured, and adjustment factors in the model were required. The purpose of this paper is to introduce the development of a multi-node ullage model using GFSSP and to discuss the improvements of the simulated ullage temperature distribution and its resulting effects on ullage heat transfer processes. Test data from the Cryogenic Propellant Storage and Transfer Engineering Developmental Unit (CPST EDU) was used for model validation. For additional comparison, a Thermal Desktop (TD) model was also developed to analyze the CPST EDU direct ullage pressurization tests using both a single node and multi-node approach. The model includes the direct pressurant line, vent line, fill/drain line, and a TD FloCAD Compartment. The TD FloCAD Compartment is employed to represent the liquid and ullage as single volumes inside the tank, to include a liquid/vapor interface, and to generate network level objects such as lumps (analogous to nodes in GFSSP), paths, and ties between the fluid and thermal elements. An established heat load on the model tank was leveraged from a pre-existing higher-fidelity model correlated to CPST EDU test data.

pressurization↗

Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Helium

Understanding two-phase cryogenic propellant behavior is key to enabling technologies for future spaceflight missions. Developing accurate models of two-phase flow phenomena, particularly flow boiling in the heating configuration is relevant to the propellant transfer process both in microgravity and on other planetary surfaces. Currently there is a need for more accurate, direct cryogenic data anchored models for various boiling phenomena. Recently, universal correlations for cryogens flowing in heated tubes have been developed for a wide variety of fluids, thermodynamic conditions, and various regimes across the boiling curve, and have been patched to provide a smooth, continuous predictive curve. This paper demonstrates how these correlations have been ported into Thermal Desktop to improve predictive performance. To test the validity of the new correlations, Thermal Desktop is validated against a historical dataset of flow boiling experiments in the heating configuration using liquid helium. Based on results, the new correlations show a substantial improvement over the original built-in flow boiling correlations in Thermal Desktop in predicting the wall temperature as a function of preponderant parameters for this quantum fluid.

cryogenic propellant transfer↗

Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Helium

Understanding two-phase cryogenic propellant behavior is key to enabling technologies for future spaceflight missions. Developing accurate models of two-phase flow phenomena, particularly in the current work, flow boiling in the heating configuration, is relevant to the propellant transfer process both in 1-g and microgravity. Currently there is a need for more accurate, direct cryogenic data anchored models for various boiling phenomena. Recently, universal correlations for cryogens flowing in heated tubes have been developed for a wide variety of fluids, thermodynamic conditions, and various regimes across the boiling curve, and have been patched to provide a smooth, continuous predictive curve. This paper describes implementation and validation of these correlations into Thermal Desktop to improve predictive performance, with a focus on liquid helium. Results from Thermal Desktop using both the built-in and new correlations are validated against a historical dataset of flow boiling experiments in the heating configuration using liquid helium. Based on results, the new correlations show a substantial improvement over the original built-in flow boiling correlations in Thermal Desktop in predicting the wall temperature as a function of preponderant parameters for this quantum fluid at temperatures greater than the lambda temperature, T λ = 2.17K.

cryogenic propellant transfer↗

Conceptual Design of a Test Section for a Cryogenic Transfer Line Experiment

This project presents the development of a comprehensive computer-aided design (CAD) model for the Transfer Line test section, which is an upcoming test module for the Flow Boiling and Condensation Experiment (FBCE) aboard the International Space Station. The FBCE aims to serve as the primary platform to study two-phase flow in microgravity, and the Transfer Line module aims to utilize its existing hardware to study cryogenic chilldown; a critical component of cryogenic propellant transfer in space. The CAD model was created using SolidWorks software and includes the test section’s main components: a heat transfer line, a flow visualization line, insulation, high-speed visible imaging, and infrared imaging. The heat transfer line primarily consists of a stainless steel tube that will be heated via Joule heating. The flow visualization line consists of segmented Indium-Titanium-Oxide coated sapphire tubes, which allow for visualization of flow regimes by high-speed and infrared cameras, similar thermal properties as the stainless steel tube, and Joule heating via the ITO coating resistance. Polyether Ether Ketone was used to insulate and encapsulate the two sections. High-speed visible imaging and infrared imaging were also incorporated to view the propagation of fluid during inverted annular flow and map out the thermal profile of the ITO-coated sapphire tube. This model serves as the guiding concept design for the Transfer Line project and will assist the project team during future safety reviews and concept design reviews. Overall, this work is significant in two-phase flow research and offers a promising path towards an established facility for cryogenic transfer line research in microgravity.

Flow boiling↗

Experimental Investigation of Flow Orientation Effects on Cryogenic Flow Boiling

Cryogenic flow boiling physics is of paramount importance for future cryogenic space applications employing Cryogenic Fluid Management (CFM) technologies. This experimental study investigates the two-phase flow and heat transfer performance of LN 2 flow boiling across five distinct flow orientations: vertical upflow, vertical downflow, horizontal flow, 45° inclined upflow, and 45° inclined downflow. The study employed the steady- state heating method within a circular heated tube featuring an 8.5-mm inner diameter and a 680-mm heated length. High-speed video recordings were utilized to capture two-phase flow patterns and interfacial behaviors across various flow orientations. The experiments covered a wide range of operating conditions, including mass velocities ranging from 351.80 to 1572.77 kg/m 2 s and inlet pressures from 297.14 to 1032.97 kPa, primarily with near-saturated inlet subcooling. Distinct two-phase flow patterns and regime transitions were identified for each flow orientation. Symmetrical flow patterns were evident in vertical orientations, whereas non-vertical orientations exhibited asymmetric flow stratifications, primarily influenced by the buoyancy force in a terrestrial gravity environment. Bubble dynamic parameters were quantified, and bubble collision and dispersion phenomena were visualized. Analyzing heat transfer performance based on local flow boiling curves and variations in heat transfer coefficients (HTCs), it was observed that vertical upflow demonstrated the most enhanced heat transfer performance, while vertical downflow exhibited the lowest. As mass velocity exceeded 830 kg/ m 2 s, the differences in heat transfer among orientations became less distinct, emphasizing the role of flow inertia in mitigating the influence of flow orientation. A direct comparison of microgravity HTC data from a recent study by the authors against the 1-𝘨 e HTC data indicated enhanced heat transfer performance in microgravity for flow orientation configurations in terrestrial gravity. However, this enhancement progressively diminished as the heat flux increased. Distinct HTC trends were observed as mass velocity increased for different flow orientations and gravity levels.

Cryogens↗

Development of Cryogenic Phase Change Materials for Lunar Sample Return

One of the scientific goals of NASA’s Artemis missions is to return regolith samples from the lunar surface. To maintain scientific integrity of these samples, including any volatiles that may exist, cryogenic stowage is desired. FROSTE (Frozen Return Of Samples To Earth) is the element of the Moon to Mars architecture that is tasked with developing and advancing concepts related to this goal. Both active and passive solutions are being considered, but active solutions (cryo-coolers) have high mass and cost penalties. Phase change materials (PCMs) are commonly used as passive thermal management solutions, particularly for sensitive scientific samples. However, there are currently no PCMs capable of providing cooling at the cryogenic temperatures needed to enable lunar sample return with volatiles intact (<120 K). FROSTE has identified two possible candidate materials that could fill this gap. Testing is required to verify the thermal performance of these materials, as well as gain experience with their handling characteristics. We are conducting this testing at the Marshall Space Flight Center’s Space Environmental Effects laboratory, in vacuum, with liquid nitrogen providing cooling ability below the freezing point of the materials. In this talk, we will present an overview of the FROSTE program element and share results from the initial development testing of two cryogenic phase change materials.

phase change material↗

Radioisotope dating of nuclear materials using cryogenic decay energy spectrometry

Cryogenic decay energy spectrometry provides high energy resolution and enables absolute decay counting, offering an alternative measurement technique for radiochronometry. A cryogenic decay energy spectrometry experiment was conducted using a magnetic microcalorimeter to determine the age of a plutonium sample. The energy resolution was measured at 0.05% from 5 to 6 MeV. The time since sample purification was determined using the measured concentration ratio of the 241 Am/ 241 Pu radiochronometer. Sample age estimates based on 241 Pu alpha-decay and beta-decay counts, along with 241 Am decay counts, align with the expected sample age within expanded uncertainty (k = 2), supporting the accuracy of cryogenic decay energy spectrometry as a radiochronometric method.

and nuclear chemistry↗

Reduced-order CFD modeling of cryogenic hydrogen isotope extrusion for pellet fueling

This study presents a reduced-order model (ROM) for computational fluid dynamics (CFD) simulations of cryogenic hydrogen isotope extrusions, focusing on protium (H₂) and deuterium (D₂) piston extruders. Using a 2D axisymmetric ROM in ANSYS-Polyflow, significant computational savings were achieved (runtime reduced from 9∼24 h to 3∼5 min), with extrusion force discrepancies between the 2D ROM and 3D models being on the order of 1%. Parametric studies identified optimal cutoff shear rates in the viscosity model (0.01/s for H₂ and 0.001/s for D₂), providing recommendations for future simulations. Finally, a comprehensive comparison of ROM results with experimental data was performed across varying geometries, cryogenic materials, temperatures, extrusion lengths, and piston velocities. Predictions at low extrusion temperatures met the objective of providing quick and efficient solutions with an acceptable extrusion force error of approximately 10% or less, validating the effectiveness of the 2D ROM approach. However, at high temperatures closer to the triple point, extrusion force error grows, which necessitates developing an improved model that accounts for temperature effects, e.g. melting. Nevertheless, the findings still represent a significant improvement in efficiency of CFD modeling of cryogenic hydrogenic extrusion. The ROM framework can also be extended to tritium (T2) and screw extruders, which will ultimately provide a fast and effective tool for optimizing pellet injector design for ITER and future reactor systems.

Fan, Joy [ORNL] (ORCID:0000000229751735)↗

Tandem Mass-Selective Cryogenic Digital Ion Traps for Enhanced Cluster Formation

We present the implementation of tandem mass-selective cryogenic ion traps, designed to enhance the range of ion processing capabilities that can be performed prior to spectroscopic interrogation. We show that both the formation of ion clusters and mass filtering steps can be combined in a single cryogenic linear quadrupole ion trap driven by RF square waves. Mass filtering and mass isolation can be achieved by manipulation of the RF frequency and duty cycle. Very importantly, this scheme circumvents the need for high-amplitude RF voltages that can be incompatible with typical cryogenic ion processing conditions. In addition, proper adjustment of the stability boundaries during the clustering process allows for the preferential formation of a specific cluster size rather than a broad distribution of sizes. Lastly, we show that a specific cluster size can be formed, mass-selected, and then transferred to another ion trap for a second completely separate ion processing step. Furthermore, the instrumentation and modular design developed here expand the scope of ionic species and clusters that can be accessed by processing electrosprayed ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of mApple as a Red Fluorescent Protein for Cryogenic Single-Molecule Imaging with Turn-Off and Turn-On Active Control Mechanisms

Single-molecule superresolution microscopy is a powerful tool for the study of biological structures on size scales smaller than the optical diffraction limit. Imaging samples at cryogenic temperatures (77 K) reduces the quantum yield of photobleaching for many fluorescent labels, yielding localization precisions below 10 nm. Cryogenic imaging further enables correlation with cryogenic electron tomography. A key limitation in applying methods such as PALM and STORM to samples maintained at 77 K is the limited number of fluorophores known to undergo efficient turn-on and turn-off mechanisms necessary to control the sparsity of active emitters. Here we find that mApple, a red-emitting fluorescent protein, undergoes a novel turn-off mechanism in response to simultaneous illumination with two colors of light. This turn-off mechanism enables localization of many individual molecules in initially bright samples, but the final density of localizable emitters is limited by relatively inefficient turn-on (photoactivation). Bulk excitation and emission spectroscopy shows that mApple has access to two distinct emissive states as well as dark states accessible optically or through changes in pH. The bright and stable emission of mApple enables widefield collection of single-molecule emission spectra, which highlight the complex nature and environmental sensitivity of states observed in red fluorescent proteins.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical interference for the guidance of cryogenic focused ion beam milling beyond the axial diffraction limit

Cryogenic focused ion beam (Cryo-FIB) milling has become a standard step in the cryogenic electron tomography (Cryo-ET) workflow and is required to thin cells to electron-semitransparency. However, this destructive process removes the vast majority of the cellular material and raises a critical question: what thin section should be preserved for Cryo-ET analysis? Using a tri-coincident cryogenic FIB-SEM-LM system, we identify an interferometric optical response that can be used for targeting lamella production to fluorescently labeled structures with accuracy beyond the diffraction limit. Here we demonstrate this approach using synthetic samples of fluorescent beads embedded in micron-scale droplets of amorphous ice. We then apply the approach to capture virions inside host cells. Successful targeting is confirmed by Cryo-ET revealing clusters of virions in intracellular vesicles. The method does not require any fluorescent fiducials or axial registration and can be performed on any fluorescently labeled structure that is visible in widefield fluorescence microscopy.

Cryoelectron microscopy↗