Search NASA⌕ Search

SEARCH · Search NASA

Results for “customize”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Estimating the cost of saving electricity through U.S. utility customer-funded energy efficiency programs

The program administrator and total cost of saved energy allow comparison of the cost of efficiency across utilities, states, and program types, and can identify potential performance improvements. Comparing program administrator cost with the total cost of saved energy can indicate the degree to which programs leverage investment by participants. Based on reported total costs and savings information for U.S. utility efficiency programs from 2009 to 2013, here we estimate the savings-weighted average total cost of saved electricity across 20 states at 0.046 per kilowatt-hour (kW h), comparing favorably with energy supply costs and retail rates. Programs targeted on the residential market averaged 0.030 per kW h compared to 0.053 per kW h for non-residential programs. Lighting programs, with an average total cost of 0.018 per kW h, drove lower savings costs in the residential market. We provide estimates for the most common program types and find that program administrators and participants on average are splitting the costs of efficiency in half. More consistent, standardized and complete reporting on efficiency programs is needed. Differing definitions and quantification of costs, savings and savings lifetimes pose challenges for comparing program results. Reducing these uncertainties could increase confidence in efficiency as a resource among planners and policymakers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Custom fabrication of biomass containment devices using 3-D printing enables bacterial growth analyses with complex insoluble substrates

Physiological studies of recalcitrant polysaccharide degradation are challenging for several reasons, one of which is the difficulty in obtaining a reproducibly accurate real-time measurement of bacterial growth using insoluble substrates. Current methods suffer from several problems including (i) high background noise due to the insoluble material interspersed with cells, (ii) high consumable and reagent cost and (iii) significant time delay between sampling and data acquisition. A customizable substrate and cell separation device would provide an option to study bacterial growth using optical density measurements. To test this hypothesis we used 3-D printing to create biomass containment devices that allow interaction between insoluble substrates and microbial cells but do not interfere with spectrophotometer measurements. Evaluation of materials available for 3-D printing indicated that UV-cured acrylic plastic was the best material, being superior to nylon or stainless steel when examined for heat tolerance, reactivity, and ability to be sterilized. Cost analysis of the 3-D printed devices indicated they are a competitive way to quantitate bacterial growth compared to viable cell counting or protein measurements, and experimental conditions were scalable over a 100-fold range. The presence of the devices did not alter growth phenotypes when using either soluble substrates or insoluble substrates. Furthermore, we applied biomass containment to characterize growth of Cellvibrio japonicus on authentic lignocellulose (non-pretreated corn stover), and found physiological evidence that xylan is a significant nutritional source despite an abundance of cellulose present.

3-D printing↗

A custom high-stability pulse generator for the test of a novel in-situ magnetic sensor developed to detect radiation damage in undulators

High-performance analog-to-digital converters (ADC) have been widely applied in many areas of science. For instance, magnetic field measurements based on the Faraday’s induction law require high-precision voltmeters to measure induced voltages. In this study in the context of free-electron lasers technology, the Magnetic Measurements Team at SLAC National Accelerator Laboratory proposed a novel in-situ radiation damage detection system (RDDS) for detecting small field variations in undulators. The system measures the flux change in a flexible printed-circuit coil attached to the magnet array during the undulator gap movement. The gap movement changes the magnetic field, which induces a voltage signal in the coil that is measured and integrated with an ADC. Although the system is capable of detecting relative flux changes better than 100 ppm, drift in the ADC’s gain or offset can cause apparent changes in the relative flux. This paper describes the first attempt to developed a high-precision verification circuit to perform ADC testing in the framework of the novel RDDS. The circuit generates a reference voltage pulse with a voltage–time integral relative precision better than 50 ppm for a few hundreds of mVs — the typical order of magnitude measured with the RDDS. The circuit’s design combines a fast and precise switch with a low-noise voltage reference. Long-term measurements allowed statistical analysis and showed that averaging the voltage–time integral of ten pulses gives the required 50 ppm stability. Moreover, reproducibility tests confirmed that the circuit’s output is invariable under small power supply instabilities and equipment shutdown. Instruments and applications designed to quantify the magnetic field by integrating voltage signals may use the pulse generator proposed in this paper for verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced manufacturing of 3D custom boron-carbide collimators designed for complex environments for neutron scattering

Scattered-beam collimation is a very useful method to reduce unwanted backgrounds and to boost the desired sample signal instead. This approach is of particular interest for samples contained within a complex environment that gives rise to much unwanted parasitic scatter. As neutron scattering instrument and techniques advances, small samples are becoming of more and more interest, which necessitates optimized collimation. Here, in this work, we describe a concept for the design and fabrication of advanced scattered-beam collimation 3D printed from B 4 C specifically tailored for samples contained within a complex environment. This concept is demonstrated through the use of a diamond anvil cell for high pressure experimentation, a technique that very typically requires small samples. The collimators here are designed through a modeling procedure via Monte Carlo neutron ray tracing that encompasses the entire system: the instrument, the complex environment and the collimator. Since the first approach of simply scaling up of the print-size was not successful, a novel concept of a multi-part alternate-blade collimator was developed. This approach addresses printing constraints but gives greater flexibility in design. Its performance is computationally compared against an unprintable progressively tighter blade collimator to assess the effect of alternating blades. No strong difference was observed. Its performance was validated through experimentation at the Spallation Neutron Source. The results emphasize the critical importance of ultra-high precision alignment while showing good overall agreement between simulation and experiment and underscore the feasibility of the method and its real-world application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A methodology for customizing implantation profiles of light ions using a single thin foil energy degrader

We report a method was developed to quantify the spatial distribution and implantation depth of energy-degraded light ions with a thin foil rotating energy degrader for use during multiple ion beam irradiation. The methodology covers three physical phenomena: ions passing through the thin foil, ions travelling through the vacuum to the target, and ion implantation into the target, and accounts for the distribution of ions both in depth and in plane. The processes of energy straggling and scattering were calculated using SRIM. The effects of raster-scanning, and the geometry of the system were implemented in scripts handling the SRIM output files. Elastic backscattering (EBS) using 2.38 MeV H+ protons was used to measure the helium depth profiles after implantation with and without thin foil energy degradation. Defect analysis with transmission electron microscopy confirmed the implantation profiles measured with EBS and calculated with SRIM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D printed polymer gaskets for custom-form batteries

Additive manufacturing (AM) processes, like 3D printing, help to facilitate complex and customizable battery geometries which can provide design freedom and enhance volumetric energy density within electronic devices. AM materials must have the thermal and mechanical properties that enable printability, and when used in batteries, AM materials must also be chemically and electrochemically compatible with the battery chemistry. The compatibility between AM materials and the battery is of particular importance for the cell packaging materials which must be inert and are often overlooked. This study systematically studies AM-compatible polymeric materials for use as gaskets in lithium-ion cells. The materials investigated include three thermoplastics suitable for material extrusion printing: polylactic acid (PLA), polycarbonate, and polypropylene/polyethylene copolymer (PPPEC); and two photoresins suitable for vat photopolymerization (VPP) printing: an acrylate-based photoresin and a polyethylene glycol diacrylate photoresin. The AM gasket materials were tested in comparison to a conventional commercial polypropylene gasket. Mechanical testing (swell measurements and material stiffness) and electrochemical testing (linear sweep voltammetry and galvanostatic cycling of full cells) demonstrated that PLA and the VPP polymers were the least compatible with the lithium-ion battery chemistry, despite their prevalent use in studies of AM batteries, and that PPPEC was the most compatible.

3D printing↗