Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Thin film photoelectrodes for solar water splitting

Photoelectrochemical (PEC) water splitting has been intensively studied in the past decades as a promising method for large-scale solar energy storage. Among the various issues that limit the progress of this field, the lack of photoelectrode materials with suitable properties in all aspects of light absorption, charge separation and transport, and charge transfer is a key challenge, which has attracted tremendous research attention. A large variety of compositions, in different forms, have been tested. This review aims to summarize efforts in this area, with a focus on materials-related considerations. Issues discussed by this review include synthesis, optoelectronic properties, charge behaviors and catalysis. In the recognition that thin-film materials are representative model systems for the study of these issues, we elected to focus on this form, so as to provide a concise and coherent account on the different strategies that have been proposed and tested. Because practical implementation is of paramount importance to the eventual realization of using solar fuel for solar energy storage, we pay particular attention to strategies proposed to address the stability and catalytic issues, which are two key factors limiting the implementation of efficient photoelectrode materials. To keep the overall discussion focused, all discussions were presented within the context of water splitting reactions. Finally, how the thin-film systems may be applied for fundamental studies of the water splitting chemical mechanisms and how to use the model system to test device engineering design strategies are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plastic recovery and self-healing in longitudinally twinned SiGe nanowires

This paper reports on plastic recovery and self-healing behavior in longitudinally-twinned and [112] orientated SiGe nanowire (NW) beams when they are subjected to large bending strains. The NW alloys are comprised of lamellar nanotwin platelet(s) sandwiched between two semi-cylindrical twins. The loading curves, which are acquired from atomic force microscope (AFM) based three-point bending tests, reveal the onset of plastic deformation at a characteristic stress threshold, followed by further straining of the NWs. This ductility is attributed to dislocation activity within the semi-cylindrical crystal portions of the NW, which are hypothesized to undergo a combination of elastic and plastic straining. On the other hand, the lamellar nanoplatelets undergo purely elastic stretching. During the unloading process, the release of internal elastic stresses enables dislocation backflow and escape at the surface. As a result, the dislocations are predominantly annihilated and the NW samples evidenced self-healing via plastic recovery even at ultra-large strains, which are estimated using finite-element models at 16.3% in one of the tested devices. Finite element analysis also establishes the independence of the observed nanomechanical behavior on the relative orientation of the load with respect to the nanoplatelet. This first observation of reversible plasticity in the SiGe material system, which is aided by a concurrent evolution of segmented elastic and plastic deformation within its grains during the loading process, presents an important new pathway for mechanical stabilization of technologically important group-IV semiconductor nanomaterials.

36 MATERIALS SCIENCE↗

In situ X-ray spatial profiling reveals uneven compression of electrode assemblies and steep lateral gradients in lithium-ion coin cells

Coin cells are used extensively as test devices in battery research for evaluation of new materials and optimization of cycling protocols. Here, in situ X-ray diffraction profilometry is used to characterize spatial distribution of the active materials, lithiation, and phase distribution in electrodes of NCM523/graphite coin cells. The X-ray data indicate uneven areal compression of the electrode assembly in such cells, which we trace to a specific design feature that leads to elastic deformation of a metal spacer. Steep lithiation gradients observed in the electrodes imply radially-dependent resistivity, for which uneven compression of the separator is a likely cause. Electrochemical model calculations suggest that variable porosity of the polymer separator would account for the salient features of spatial profiles observed in these coin cells.

25 ENERGY STORAGE↗

Morphology-driven oxygen evolution performance of NiO x nanostructures and implications for hole transport in perovskite solar cells

Morphology-controlled nanostructures provide an effective strategy to modulate both oxygen evolution reaction (OER) activity and photovoltaic performance in perovskite solar cells (PSCs). However, achieving low OER overpotentials and high power conversion efficiency (PCE) simultaneously through morphology engineering remains challenging. In this work, nickel oxide (NiO x ) nanostructures with spindle-like (NiO x -NS) and plate-like (NiO x -NP) morphologies were synthesized and evaluated as bi-functional OER catalysts and hole transport layers (HTLs) in inverted PSCs. Structural and thermal analyses reveal that NiO x -NS crystallizes into a cubic phase at a lower temperature (300 °C), whereas NiO x -NP requires higher calcination temperatures, reflecting differences in precursor microstructure. Electrochemical measurements indicate that NiO x -NS calcined at 300 °C delivers the lowest OER overpotential (395 mV at 10 mA cm −2 ), outperforming NiO x -NP calcined at 400 °C (565 mV) and 500 °C (474 mV). This enhanced activity is ascribed to favorable surface strain, increased defect density, and advantageous facet exposure. When used as HTLs, NiO x -NS also delivers the highest PCE (13.25%) among all tested devices, exceeding those based on NiO x -NP and commercial NiO x , owing to improved hole extraction and interfacial contact. Overall, this study highlights the importance of morphology control and thermal processing in tailoring NiO x for multifunctional nanomaterials in electrocatalytic and photovoltaic applications.

36 MATERIALS SCIENCE↗

Note: Reliable low-vibration piezo-mechanical shutter

We present a mechanical shutter based on a bending piezo-actuator. The shutter features an active aperture of about 2 mm, allowing for full extinction and lossless transmission of a beam. Acoustic noise and mechanical vibrations produced are very low and the shutter is outstandingly long-lived; a test device has undergone 20 × 10{sup 6} cycles without breaking. A reflector makes the shutter capable of reliably interrupting a beam with at least 2 W of cw power at 780 nm. The shutter is well suited to create pulses as short as 16 ms, while pulse lengths down to 1 ms are possible. The rise and fall times are approximately 120 µs, with a delay of 2 ms. Jitter stays below 10 µs, while long-term drifts stay well below 500 µs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tb{sub 2}O{sub 3} thin films: An alternative candidate for high-k dielectric applications

We are reporting the growth and structural, optical, and dielectric properties of Tb{sub 2}O{sub 3}, a relatively unexplored high-k dielectric material. A pulsed-laser deposition technique was used to grow Tb{sub 2}O{sub 3} thin-films on four different substrates: Si(100), SrTiO{sub 3}(100), LaAlO{sub 3}(100), and MgO(100). High-resolution X-ray diffraction and transmission electron microscopy results confirmed that film growth in an oxygen-rich (10{sup −1 }Torr) environment yields nearly single-crystal C-phase films, while a low-oxygen (10{sup −6 }Torr) environment growth results in the formation of monoclinic polycrystalline B-phase films. Optical transmission measurements showed that the bandgap of Tb{sub 2}O{sub 3} is direct in nature with a value of 2.8 eV and 3.4 eV for the cubic and monoclinic phases, respectively. By measuring the capacitance of test devices, quite high dielectric constants of 13.5 and 24.9 were obtained for the B- and C-phase Tb{sub 2}O{sub 3} films, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theoretical and experimental analysis of AlGaInP micro-LED array with square-circle anode

An array of 320 × 240 micro-light-emitting diodes (micro-LEDs) based on an AlGaInP epitaxial wafer and with a unit size of 100 µm×100 µm was designed and fabricated. The optimum width of the isolation groove between adjacent light-emitting units was determined based on a compromise between full isolation of each LED and maximization of the light emitting area, and was found to be 20 µm. The grooves were filled with a mixed Si granule-polyurethane composite medium, because this type of insulating material can reflect part of the emitted light from the sidewall to the window layer in each light-emitting unit, and could thus improve lighting output efficiency. The 10-µm-wide square-circle anode was designed to increase the light emitting area while simultaneously being simple to fabricate. The device current used was in the 0.42–1.06 mA range to guarantee internal quantum efficiency of more than 85%, with a corresponding voltage range of 2–2.3 V. The layered temperature distribution in a single unit was simulated under a drive voltage of 2.2 V, and the maximum device temperature was 341 K. The micro-opto-electro-mechanical systems (MOEMS) technology-based fabrication process, experimental images of the device and device test results are presented here.

36 MATERIALS SCIENCE↗

Efficient and robust analysis of complex scattering data under noise in microwave resonators

Superconducting microwave resonators are reliable circuits widely used for detection and as test devices for material research. A reliable determination of their external and internal quality factors is crucial for many modern applications, which either require fast measurements or operate in the single photon regime with small signal to noise ratios. Here, we use the circle fit technique with diameter correction and provide a step by step guide for implementing an algorithm for robust fitting and calibration of complex resonator scattering data in the presence of noise. The speedup and robustness of the analysis are achieved by employing an algebraic rather than an iterative fit technique for the resonance circle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact anti-radon facility

Suppression of radon background is one of main tasks in ultra-low background experiments. The most promising technique for suppression of radon is its adsorption on charcoal. Within the frame of the NEMO-3 experiment, radon trapping facility (RTF) was installed in Modane underground laboratory in 2004. Based on long-term experience with this facility a new compact transportable anti-radon facility was constructed in cooperation among IEAP CTU, SÚRO and ATEKO company. The device provides 20m{sup 3}/h of purified air (air radon activity at the output ∼10mBq/m{sup 3}). The basic features and preliminary results of anti-radon device testing are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accuracy improvement in a calibration test bench for accelerometers by a vision system

A procedure is described in this paper for the accuracy improvement of calibration of low-cost accelerometers in a prototype rotary test bench, driven by a brushless servo-motor and operating in a low frequency range of vibrations (0 to 5 Hz). Vibration measurements by a vision system based on a low frequency camera have been carried out, in order to reduce the uncertainty of the real acceleration evaluation at the installation point of the sensor to be calibrated. A preliminary test device has been realized and operated in order to evaluate the metrological performances of the vision system, showing a satisfactory behavior if the uncertainty measurement is taken into account. A combination of suitable settings of the control parameters of the motion control system and of the information gained by the vision system allowed to fit the information about the reference acceleration at the installation point to the needs of the procedure for static and dynamic calibration of three-axis accelerometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Non-neutral plasma manipulation techniques in development of a high-capacity positron trap

Preliminary experiments have been performed toward the development of a multi-cell Penning–Malmberg trap for the storage of large numbers of positrons (≥10 10 e + ). We introduce the master-cell test trap and the diagnostic tools for first experiments with electrons. The usage of a phosphor screen to measure the z-integrated plasma distribution and the number of confined particles is demonstrated, as well as the trap alignment to the magnetic field ( B = 3.1 T) using the m = 1 diocotron mode. The plasma parameters and expansion are described along with the autoresonant excitation of the diocotron mode using rotating dipole fields and frequency chirped sinusoidal drive signals. We analyze the reproducibility of the excitation and use these findings to settle on the path for the next generation multi-cell test device.

Singer, M.↗

Emerging opportunities for hybrid perovskite solar cells using machine learning

While there are several bottlenecks in hybrid organic–inorganic perovskite (HOIP) solar cell production steps, including composition screening, fabrication, material stability, and device performance, machine learning approaches have begun to tackle each of these issues in recent years. Different algorithms have successfully been adopted to solve the unique problems at each step of HOIP development. Specifically, high-throughput experimentation produces vast amount of training data required to effectively implement machine learning methods. Here, we present an overview of machine learning models, including linear regression, neural networks, deep learning, and statistical forecasting. Experimental examples from the literature, where machine learning is applied to HOIP composition screening, thin film fabrication, thin film characterization, and full device testing, are discussed. These paradigms give insights into the future of HOIP solar cell research. As databases expand and computational power improves, increasingly accurate predictions of the HOIP behavior are becoming possible.

Hering, Abigail R. (ORCID:0000000270806953)↗

Achieving high power factor and output power density in p-type half-Heuslers Nb 1-x Ti x FeSb

Significance Thermoelectric technology can boost energy consumption efficiency by converting some of the waste heat into useful electricity. Heat-to-power conversion efficiency optimization is mainly achieved by decreasing the thermal conductivity in many materials. In comparison, there has been much less success in increasing the power factor. We report successful power factor enhancement by improving the carrier mobility. Our successful approach could suggest methods to improve the power factor in other materials. Using our approach, the highest power factor reaches ∼106 μW⋅cm −1 ⋅K −2 at room temperature. Such a high power factor further yields a record output power density in a single-leg device tested between 293 K and 868 K, thus demonstrating the importance of high power factor for power generation applications.

36 MATERIALS SCIENCE↗

The 2023 terahertz science and technology roadmap

Abstract Terahertz (THz) radiation encompasses a wide spectral range within the electromagnetic spectrum that extends from microwaves to the far infrared (100 GHz–∼30 THz). Within its frequency boundaries exist a broad variety of scientific disciplines that have presented, and continue to present, technical challenges to researchers. During the past 50 years, for instance, the demands of the scientific community have substantially evolved and with a need for advanced instrumentation to support radio astronomy, Earth observation, weather forecasting, security imaging, telecommunications, non-destructive device testing and much more. Furthermore, applications have required an emergence of technology from the laboratory environment to production-scale supply and in-the-field deployments ranging from harsh ground-based locations to deep space. In addressing these requirements, the research and development community has advanced related technology and bridged the transition between electronics and photonics that high frequency operation demands. The multidisciplinary nature of THz work was our stimulus for creating the 2017 THz Science and Technology Roadmap (Dhillon et al 2017 J. Phys. D: Appl. Phys. 50 043001). As one might envisage, though, there remains much to explore both scientifically and technically and the field has continued to develop and expand rapidly. It is timely, therefore, to revise our previous roadmap and in this 2023 version we both provide an update on key developments in established technical areas that have important scientific and public benefit, and highlight new and emerging areas that show particular promise. The developments that we describe thus span from fundamental scientific research, such as THz astronomy and the emergent area of THz quantum optics, to highly applied and commercially and societally impactful subjects that include 6G THz communications, medical imaging, and climate monitoring and prediction. Our Roadmap vision draws upon the expertise and perspective of multiple international specialists that together provide an overview of past developments and the likely challenges facing the field of THz science and technology in future decades. The document is written in a form that is accessible to policy makers who wish to gain an overview of the current state of the THz art, and for the non-specialist and curious who wish to understand available technology and challenges. A such, our experts deliver a ‘snapshot’ introduction to the current status of the field and provide suggestions for exciting future technical development directions. Ultimately, we intend the Roadmap to portray the advantages and benefits of the THz domain and to stimulate further exploration of the field in support of scientific research and commercial realisation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Collisionless losses of fast ions in the Divertor Tokamak Test due to toroidal field ripple

In this paper we analyze fast ion motion in the Divertor Tokamak Test device. DTT is planned to be heated through a mix of 45 MW heating power, including 15 MW negative-ion-based Neutral Beam heating (NNBI) which is currently being developed by Consorzio RFX in Padova, Italy. An issue for DTT is that a Toroidal Field (TF) ripple with a maximum value of about 0.42% (with respect to the on-axis magnetic field $B_0$) is expected on the low-field side (LFS), and this ripple interacts with fast ions through rather well-known phenomena of ripple-precession resonances, in addition to prompt losses of ions which do not complete a full orbit in the poloidal plane. We will show that, with the planned geometry of NNBI, prompt losses are negligible, and ripple-precession losses amount to a maximum 0.15%. The calculations are performed with the guiding center code ORBIT using two different equilibria, and a beam with energy 400 keV and injection angle $\alpha_{inj} = 40^{\circ}$ (measured w.r.t. the first wall), which corresponds to a pitch of injected particles $\lambda = v_{\parallel}/v \approx \sin{\alpha_{inj}} = 0.65$. Main resonances are of the form $\omega_b - n N \omega_d = 0$, $\omega_b$ and $\omega_d$ being the bounce and precession frequency, respectively, $N=18$ the ripple periodicity and $3 \le n \le 6$ are the toroidal wavenumbers of the resonances. Although collisionless interaction with the TF ripple does not pose a serious threat to the NNBI project, an open question remains whether the presence of these resonances will interact with fast particles accelerated by \alfven eigenmodes, and if stochastization of the resonances is possible in DTT, as it was observed in the past in TORE SUPRA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing Sensor Count and Placement to Detect Bond Wire Lift-Offs and Surface Defects in High-Power IGBT Modules Using Low-Cost Piezo-Electric Resonators

This manuscript presents the most recent results and findings to identify bond wire lift-offs and surface defects in high-power isolated gate bipolar junction transistor (IGBT) modules. The authors of this manuscript formerly proposed a low-cost, piezoelectric resonator-based measurement unit to detect bond wire related degradation in larger IGBT modules. Since high-power IGBT modules are expensive, it was apparent that evaluating our proposed method by inducing controlled damage to fresh (new) IGBTs may not be cost-effective especially when multiple sets of data need to be captured by inducing damage to different levels. In order to overcome this limitation, IGBT bond wires have been mimicked using a 3D printed enclosure, a PCB, and copper wires with dimensions very closely resembling a real IGBT. Using this method, multiple test devices can be built at the cost of a real IGBT, and the proposed technique could be fine-tuned without damaging expensive, real IGBTs. Our recent findings can be used to determine real IGBT degradation and bond wire lift-offs using only two sensors, as opposed to six transducers used in the first iteration of the setup. In addition to optimizing the sensor count, we have also identified the best possible locations of these sensors by attempting multiple placements inside the IGBT casing.

condition monitoring↗

DQE of wireless digital detectors: Comparative performance with differing filtration schemes

Purpose: Wireless flat panel detectors are gaining increased usage in portable medical imaging. Two such detectors were evaluated and compared with a conventional flat-panel detector using the formalism of the International Electrotechnical Commission (IEC 62220-1) for measuring modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE) using two different filtration schemes.Methods: Raw images were acquired for three image receptors (DRX-1C and DRX-1, Carestream Health; Inc., Pixium 4600, Trixell) using a radiographic system with a well-characterized output (Philips Super80 CP, Philips Healthcare). Free in-air exposures were measured using a calibrated radiation meter (Unfors Mult-O-Meter Type 407, Unfors Instruments AB). Additional aluminum filtration and a new alternative combined copper-aluminum filtration were used to conform the x ray output to IEC-specified beam quality definitions RQA5 and RQA9. Using the IEC 62220-1 formalism, each detector was evaluated at X{sub N}/2, X{sub N}, and 2X{sub N}, where the normal exposure level to the detector surface (X{sub N}) was set to 8.73 μGy (1.0 mR). The prescribed edge test device was used to evaluate the MTF, while the NNPS was measured using uniform images. The DQE was then calculated from the MTF and NNPS and compared across detectors, exposures, and filtration schemes.Results: The three DR systems had largely comparable MTFs with DRX-1 demonstrating lower values above 1.0 cycles/mm. At each exposure, DRX-1C and Pixium detectors demonstrated better noise performance than that of DRX-1. Zero-frequency DQEs for DRX-1C, Pixium, and DRX-1 detectors were approximately 74%, 63%, and 38% for RQA5 and 50%, 42%, and 28% for RQA9, respectively.Conclusions: DRX-1C detector exhibited superior DQE performance compared to Pixium and DRX-1. In terms of filtration, the alternative filtration was found to provide comparable performance in terms of rank ordering of different detectors with the added convenience of being less bulky for in-the-field measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effective DQE (eDQE) for monoscopic and stereoscopic chest radiography imaging systems with the incorporation of anatomical noise

Purpose: Stereoscopic chest biplane correlation imaging (stereo/BCI) has been proposed as an alternative modality to single view chest x-ray (CXR). The metrics effective modulation transfer function (eMTF), effective normalized noise power spectrum (eNNPS), and effective detective quantum efficiency (eDQE) have been proposed as clinically relevant metrics for assessing clinical system performance taking into consideration the magnification and scatter effects. This study compared the metrics eMTF, eNNPS, eDQE, and detectability index for stereo/BCI and single view CXR under isodose conditions at two magnifications for two anthropomorphic phantoms of differing sizes.Methods: Measurements for the eMTF were taken for two phantom sizes with an opaque edge test device using established techniques. The eNNPS was measured at two isodose conditions for two phantoms using established techniques. The scatter was measured for two phantoms using an established beam stop method. All measurements were also taken at two different magnifications with two phantoms. A geometrical phantom was used for comparison with prior results for CXR although the results for an anatomy free phantom are not expected to vary for BCI.Results: Stereo/BCI resulted in improved metrics compared to single view CXR. Results indicated that magnification can potentially improve the detection performance primarily due to the air gap which reduced scatter by ∼20%. For both phantoms, at isodose, eDQE(0) for stereo/BCI was ∼100 times higher than that for CXR. Magnification at isodose improved eDQE(0) by ∼10 times for stereo/BCI. Increasing the dose did not improve eDQE. The detectability index for stereo/BCI was ∼100 times better than single view CXR for all conditions. The detectability index was also not improved with increased dose.Conclusions: The findings indicate that stereo/BCI with magnification may improve detectability of subtle lung nodules compared to single view CXR. Results were improved with magnification for the smaller phantom but not for the larger phantom. The effective DQE and the detectability index did not improve with increasing dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗