Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Leveraging Inequality-Constrained Data for Enhanced Liquidus Temperature Prediction in Nuclear Waste Glass Melts

Inequality-constrained data are frequently discarded in engineering, leading to significant information loss in data-scarce domains like glass characterization in nuclear waste vitrification. This paper presents a nonparametric censored-data regression framework based on an l1-norm optimization criterion that leverages slack variables to integrate left-, right-, and interval-constrained observations into training without distributional assumptions. Validated on synthetic data and a Physics-Informed Neural Network (PINN) for predicting liquidus temperature (TL), the method improved R2 from 0.60 to 0.89 and reduced Mean Absolute Error (MAE) by 48% (51.46 to 26.89?rC) on deterministic values. The traditional models failed to satisfy any inequality constraints while the proposed l1-norm PINN satisfies 81.25% of the constraints. The proposed framework effectively extracts actionable information from previously unusable data to enhance predictive accuracy, reduce epistemic uncertainty, and ensure physical consistency in complex industrial applications.

Garcia-Morado, Erick↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Management in the Continuum: Cross-facility Object-based Data Transfers

Scientific workflows are evolving from relying on a monolithic storage subsystem at a single High-Performance Computing (HPC) facility to using geographically distributed file systems, repositories, and cloud storage. As a result, storing, accessing, transferring, and managing scientific data have become highly complex and prone to performance inefficiencies. This paper delves into these challenges by exploring an optimized end-to-end interface designed to seamlessly connect various local and remote storage systems, enabling efficient data movement of objects across HPC–Cloud and HPC–HPC environments. We showcase this capability through an object-focused data management runtime system, discuss the effects of relaxed consistency semantics in distributed object scenarios, and illustrate its application in an earthquake simulation workflow. Besides reducing the amount of data by selectively transferring regions of interest, our facility-local results achieved a speedup of 45 × over an optimized HDF5 usage and 15 × over the HDF5 with caching by using the new interface in PDC-XF.

Bez, Jean Luca↗

A Scalable Solution for Grid Optimization and DER Integration (CRADA Final Report)

Utilidata Inc. is an energy software company that provides clean energy and digital solutions for utilities. This work was the result of Utilidata Inc. being awarded a New York State Energy Research and Development Agency award to integrate Utilidata volt-VAR optimization (VVO) software with smart inverters to explore enhanced voltage control. This project was conducted in partnership with Utilidata Inc., National Grid, the New York State Energy and Research Development Authority, and the National Renewable Energy Laboratory (NREL). As part of the project NREL conducted modeling and simulation analysis, developed cost-benefit analysis framework, and conducted laboratory testing to understand the potential for smart inverter integration to a centralized VVO control scheme. The remainder of the report provides an executive summary of the work, an introduction to the challenges, sections detailing specific aspects of the work, and the overall findings and conclusions.

14 SOLAR ENERGY↗

Demonstration of Algorithm for Sensor Placement Optimization using Simulation Data

This deliverable reports FY26 progress in advancing a neural-network-based Green’s-function framework for reconstructing neutron-flux distributions from ex-core measurements and for translating reconstruction requirements into a practical detector-layout strategy. Building on the FY25 formulation, the present work had two main objectives: (1) refine and re-evaluate the reconstruction methodology on an updated Purdue University Reactor Number One (PUR-1) model, and (2) develop a systematic, Green’s-function-guided procedure for boundary detector placement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design and fabrication of a four-rod radio frequency quadrupole with a variable aperture

Radiofrequency quadrupole (RFQ) linear accelerators with variable aperture cell parameters offer an effective means of accelerating high-intensity ion beams exceeding 100 mA and have been implemented in various RFQ designs. However, in a four-rod RFQ, the use of dielectric perturbation methods to measure the voltage distribution behind the rod electrodes is not applicable when implementing variable aperture geometries, because changes in the rod shape influence the electric field at the location of the perturbation element. Therefore, it was necessary to design the rod profile for each cell such that the electric field distribution behind the rods remains unaffected by changes in the aperture. In this study, we present a method to adjust the voltage distribution by modifying the geometry of the rod electrodes according to each cell's aperture parameters. This design approach enables the integration of variable aperture cells into a four-rod RFQ linac, significantly enhancing the achievable beam current. To ensure uniform capacitance and maintain a constant rod-electrode voltage despite variations in the average aperture radius, we developed a systematic method for shaping the rod electrodes. This method was refined using two-dimensional (2D) and three-dimensional (3D) electromagnetic field simulations to optimize the electrode cross-sectional profiles. The fabricated rod electrodes were then installed in a four-rod RFQ, and the electric field distribution was measured using the perturbation method and tuned by adjusting the base plates. As a result, the measured variation of ±1.1 % confirms that this design methodology can produce a sufficiently uniform voltage distribution for high-current beam acceleration. These results demonstrate the practical feasibility of a variable-aperture four-rod RFQ linac.

43 PARTICLE ACCELERATORS↗

Multilaminate Energy Storage Films from Entropy‐Driven Self‐Assembled Supramolecular Nanocomposites

Abstract Composite materials comprising polymers and inorganic nanoparticles (NPs) are promising for energy storage applications, though challenges in controlling NP dispersion often result in performance bottlenecks. Realizing nanocomposites with controlled NP locations and distributions within polymer microdomains is highly desirable for improving energy storage capabilities but is a persistent challenge, impeding the in‐depth understanding of the structure–performance relationship. In this study, a facile entropy‐driven self‐assembly approach is employed to fabricate block copolymer‐based supramolecular nanocomposite films with highly ordered lamellar structures, which are then used in electrostatic film capacitors. The oriented interfacial barriers and well‐distributed inorganic NPs within the self‐assembled multilaminate nanocomposites effectively suppress leakage current and mitigate the risk of breakdown, showing superior dielectric strength compared to their disordered counterparts. Consequently, the lamellar nanocomposite films with optimized composition exhibit high energy efficiency (>90% at 650 MV m −1 ), along with remarkable energy density and power density. Moreover, finite element simulations and statistical modeling have provided theoretical insights into the impact of the lamellar structure on electrical conduction, electric field distribution, and electrical tree propagation. This work marks a significant advancement in the design of organic–inorganic hybrids for energy storage, establishing a well‐defined correlation between microstructure and performance.

Li, He↗

Computing material volume fractions on a superimposed mesh as applied to Monte Carlo particle transport simulations

Here, we present a newly implemented ray tracing algorithm in OpenMC for efficiently computing material volume fractions on superimposed meshes in complex geometries. By firing rays along each coordinate direction through the geometry, the approach accumulates track-length data in each mesh element, thereby determining the fractional composition of each material. Scaling studies on three different models—a random tetrahedra configuration, the Frascati Neutron Generator ITER dose rate benchmark, and a stellarator design—show excellent parallel performance, with nearly linear speedup on modern multi-threaded and distributed-memory systems. An analysis of the residual error relative to high-resolution reference solutions demonstrated that under optimal conditions it decreases as 1/R, where R is the number of rays fired, making it straightforward to achieve user-prescribed accuracy. This new functionality enables practical, mesh-based approaches for detailed nuclear analyses in production Monte Carlo workflows without resorting to expensive, fully conformal or unstructured meshing.

Monte Carlo↗

Compensating slice emittance growth in high brightness photoinjectors using sacrificial charge

Achieving maximum electron beam brightness in photoinjectors requires detailed control of the 3D bunch shape and precise tuning of the beam focusing. Even in state-of-the-art designs, slice emittance growth due to nonlinear space charge forces and partial nonlaminarity often remains non-negligible. In this work, we introduce a new means to linearize the transverse slice phase space: a sacrificial portion of the bunch’s own charge distribution, formed into a wavebroken shock front by highly nonlinear space charge forces within the gun, whose downstream purpose is to dynamically linearize the desired bunch core. We show that linearization of an appropriately prepared bunch can be achieved via strongly nonlaminar focusing of the sacrificial shock front, while the inner core focuses laminarly. This leads to a natural spatial separation of the two distributions: a dense core surrounded by a diffuse halo of sacrificial charge that can be collimated. Multiobjective genetic algorithm optimizations of the ultracompact x-ray free electron laser injector employ this concept, and we interpret it with an analytic model that agrees well with the simulations. In simulation, we demonstrate a final bunch charge of 100 pC, peak current ∼ 30 A, and a sacrificial charge of 150 pC (250 pC total emitted from cathode) with normalized emittance growth of < 20 nm rad due to space charge. This implies a maximum achievable brightness approximately an order of magnitude greater than existing free electron laser injector designs. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

A GPU-based compressible combustion solver for applications exhibiting disparate space and time scales

High-speed chemically active flows pose significant computational challenges due to their disparate space and time scales, with stiff chemistry often dominating simulation time. While modern scientific computing programs achieve exascale performance by leveraging graphics processing units (GPUs), existing GPU-based compressible combustion solvers face critical limitations in memory management, load balancing, and handling the highly localized nature of chemical reactions. To this end, we present a high-performance compressible reacting flow solver built on the AMReX framework and optimized for multi-GPU settings. Here, our approach addresses three GPU performance bottlenecks: memory access patterns through column-major storage optimization, computational workload variability via a bulk-sparse integration strategy for chemical kinetics, and multi-GPU load distribution for adaptive mesh refinement applications. The solver adapts existing matrix-based chemical kinetics formulations to multi-grid contexts. Using representative combustion applications, including 2D and 3D detonations and a 3D jet-in-crossflow configuration, we demonstrate 1.4–5× performance improvements over initial implementations on an in-house cluster of NVIDIA H100 GPUs, and near-ideal weak scaling on the Frontier supercomputer (Oak Ridge Leadership Computing Facility) with up to 1024 AMD Instinct MI250X GPUs. Roofline analysis reveals substantial improvements in arithmetic intensity for both convection (∼ 10 ×) and chemistry (∼ 4 ×) routines, confirming efficient utilization of GPU memory bandwidth and computational resources.

42 ENGINEERING↗

Unalakleet Microgrid Optimization for Tribal Community Resilience

The Unalakleet Microgrid Optimization Project aimed to strengthen the reliability and efficiency of the isolated electric power system that serves the Tribal community of Unalakleet, Alaska. The community relies entirely on a local wind-diesel microgrid, consisting of four 475 kW diesel generators and six 100 kW wind turbines, to provide electricity to approximately 745 residents and Tribal facilities. Because Unalakleet is not on a road system and is located nearly 400 miles from the nearest major power grid, maintaining a resilient and efficient local energy system is critical. The scope of this project included upgrading a portion of the transmission line between the wind farm and the power plant to increase voltage and reduce line losses, along with modernizing the Supervisory Control and Data Acquisition (SCADA) system to improve monitoring, control, and data management of the power system. These upgrades were designed to increase wind energy utilization, reduce diesel fuel consumption by tens of thousands of gallons annually, and improve overall grid stability. By allowing more of the community’s electricity to be supplied by local renewable wind resources, the project was designed to lower operating costs, reduce dependence on imported fuel, and strengthen the long-term resilience of the power system. These improvements represent an important step toward the community’s long-term energy vision of expanding renewable generation, incorporating energy storage, and eventually achieving “diesels-off” operation, where essential Tribal loads are powered primarily by local renewable resources.

17 WIND ENERGY↗

Impact Analysis of Utility-Scale Energy Storage on the ERCOT Grid in Reducing Renewable Generation Curtailments and Emissions

This paper explores the solutions for minimizing renewable energy (RE) curtailment in the Texas Electric Reliability Council of Texas (ERCOT) grid. By utilizing current and future planning data from ERCOT and the System Advisor Model from the National Renewable Energy Laboratory, we examine how future renewable energy (RE) initiatives, combined with utility-scale energy storage, can reduce CO2 emissions while reshaping Texas’s energy mix. The study projects the energy landscape from 2023 to 2033, considering the planned phase-out of fossil fuel plants and the integration of new wind/solar projects. By comparing emissions under different load scenarios, with and without storage, we demonstrate storage’s role in optimizing RE utilization. The findings of this paper provide actionable guidance for energy stakeholders, underscoring the need to expand wind and solar projects with strategic storage solutions to maximize Texas's RE capacity and substantially reduce CO2 emissions.

14 SOLAR ENERGY↗

Record acceleration of the two-dimensional Ising model using a high-performance wafer-scale engine

The versatility and wide-ranging applicability of the Ising model, originally introduced to study phase transitions in magnetic materials, have made it a cornerstone in statistical physics and a valuable tool for evaluating the performance of emerging computer hardware. Here, we present a novel implementation of the two-dimensional Ising model on Cerebras Wafer-Scale Engine (WSE) – a revolutionary processor that is opening new frontiers in computing. In our deployment of the checkerboard algorithm, we optimized the Ising model to take advantage of the unique WSE architecture. Specifically, we employed a compressed bit representation storing 16 spins on each int16 word, and efficiently distributed the spins over the processing units enabling seamless weak scaling and limiting communications to only immediate neighboring units. Our implementation can handle up to 754 simulations in parallel, achieving an aggregate of over 61.8 trillion flip attempts per second for Ising models with up to 200 million spins. This represents a gain of up to 148 times over previously reported single-devices with a highly optimized implementation on NVIDIA V100 and up to 88 times in productivity compared to NVIDIA H100. Our findings highlight the significant potential of the WSE in scientific computing, particularly in the field of materials modeling.

Ising model↗

Behind-the-Meter Energy Storage and Generation in Support of Electrified Rental Car Centers

Electrification of rental car centers at major airports is expected to generate tens of MW in additional power loads. The magnitude of these loads poses challenges including high utility costs, expensive and lengthy distribution capacity upgrades, and disruptions to traditional operation. Behind-the-meter stationary battery storage and onsite photovoltaic generation offer a viable solution to these challenges without impacting the operation and business model of rental car companies, defined by minimal fleet inventory and short vehicle dwell time. Using data-driven syn-thetic charging loads for the rental car center at the Dallas/Fort Worth airport in the United States, we show that optimally-designed and controlled behind - the- meter resources can reduce the lifecycle cost of electrified rental centers by an average 41 % and reduce peak grid demand by 64 %, deferring the need for distribution upgrades or potentially avoiding it altogether.

battery storage↗

Hydrogen Production from Polyethylene Pyrolysis

Hydrogen is anticipated to play a pivotal role in the future of clean energy and decarbonization efforts, serving as an energy storage medium, a power generation source, and a clean fuel for transportation. While most hydrogen is produced from carbonaceous fossil feedstocks like natural gas, petroleum, and coal, there is growing interest in using refuse-derived fuels such as waste plastics and municipal solid waste (MSW) as alternative feedstocks. Thermochemical processes such as pyrolysis and catalytic cracking can convert nonrecyclable plastics and organic MSW components to produce hydrogen with lower life cycle greenhouse gas emissions when coupled with CO 2 capture. Such approaches not only address waste-management challenges but also reduce methane emissions from landfills. Furthermore, waste feedstocks are low cost and can support meeting demands for hydrogen across various industries. In this work we examined production of hydrogen from high-density polyethylene (HDPE) as a model polymer using pyrolysis. Analytical studies of pyrolysis utilizing gas chromatography–mass spectrometry (GC/MS) provide insights into conversion pathways for plastic waste, potentially reducing the environmental footprint of traditional hydrogen production methods. This work generates a baseline methodology for hydrogen production from plastic pyrolysis with and without a catalyst and the necessary product distribution baseline from key single plastics. The effect of pyrolysis temperature on the conversion of HDPE was evaluated both with and without a catalyst(s), and the product distributions measured via GC/MS were identified and hydrogen formation was quantified. These results will help guide future research efforts to optimize catalysts and processes for more efficient hydrogen production and mixed plastic waste management.

Catalysts↗

Improved energies and local energies with weighted variational Monte Carlo

Neural network parametrizations have increasingly been used to represent the ground and excited states in variational Monte Carlo (VMC) with promising results. However, traditional VMC methods only optimize the wave function in regions of peak probability. The wave function is uncontrolled in the tails of the probability distribution, which can limit the accuracy of the trained wave function. To improve the approximation accuracy in the probability tails, this paper interprets VMC as a gradient flow in the space of wave functions, followed by a projection step. From this perspective, arbitrary probability distributions can be used in the projection step, allowing the user to prioritize accuracy in different regions of state space. Motivated by this theoretical perspective, the paper tests a weighted VMC method on the antiferromagnetic Heisenberg model for a periodic spin chain. Compared to traditional VMC, weighted VMC reduces the error in the ground state energy by a factor of 2, and it reduces the errors in the local energies away from the mode by large factors of 10 2 –10 4 .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Xyce™ Parallel Electronic Simulator Users' Guide (V.7.9)

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been designed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: • Capability to solve extremely large circuit problems by supporting large-scale parallel computing platforms (up to thousands of processors). This includes support for most popular parallel and serial computers. • A differential-algebraic-equation (DAE) formulation, which better isolates the device model package from solver algorithms. This allows one to develop new types of analysis without requiring the implementation of analysis-specific device models. • Device models that are specifically tailored to meet Sandia’s needs, including some radiation-aware devices (for Sandia users only). • Object-oriented code design and implementation using modern coding practices. Xyce is a parallel code in the most general sense of the phrase — a message passing parallel implementation — which allows it to run efficiently a wide range of computing platforms. These include serial, shared-memory and distributed-memory parallel platforms. Attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows.

42 ENGINEERING↗

Xyce™ Parallel Electronic Simulator Users’ Guide, Version 7.10

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been designed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: • Capability to solve extremely large circuit problems by supporting large-scale parallel computing platforms (up to thousands of processors). This includes support for most popular parallel and serial computers. • A differential-algebraic-equation (DAE) formulation, which better isolates the device model package from solver algorithms. This allows one to develop new types of analysis without requiring the implementation of analysis-specific device models. • Device models that are specifically tailored to meet Sandia’s needs, including some radiation-aware devices (for Sandia users only). • Object-oriented code design and implementation using modern coding practices. Xyce is a parallel code in the most general sense of the phrase — a message passing parallel implementation — which allows it to run efficiently a wide range of computing platforms. These include serial, shared-memory and distributed-memory parallel platforms. Attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows.

97 MATHEMATICS AND COMPUTING↗