Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical connectivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Communication Network Layer State Estimation Measurement Model for a Cyber-Secure Smart Grid

Network communication has been proven to be a very important tool and a key factor in the recent development and progress of the power grid operation. It is also considered as the foundation for the smart grid because information and communication are integrated into electricity distribution to achieve reliable and accurate knowledge of the power grid. In previous years, absorbing energy from substations and delivering it to customers was the only type of interaction we knew between utility companies and customers. Presently, the growing connections of small distributed generation units caused by the cost reduction of most of the technologies used in generation and storage of electrical energy, along with the potential benefits of renewable energy have pushed many researchers to look into the improvement of information and communication technologies (ICT) in order to ensure a bidirectional flow of power and data. Moreover, the evolution of information and communication technologies and its applications to smart grid have converted the smart grid into a cyber-physical system where vulnerabilities and additional security challenges such as cyber-threats and cyber-attacks have emerged. Previously, we have demonstrated that using machine learning-based processing on data gathered from communication networks and the power grid was a promising solution for detecting cyber threats by implementing a co-simulation of cyber-security for cross-layer strategy. Since the majority of the challenges observed can only be solved in the network communication layer, we present in this work a physics-based state estimation model of the communication network system towards enhanced cyber-physical security of the smart grid. Information integration with the previously developed machine learning model is developed, providing a enhanced cyber-physical security application for the smart grid. Easy-to-implement model, without hard-to-derive parameters, highlight potential aspects of the model for real-life applications.

Mathieu, Reynold↗

FY 2021 Isolated Grids and Grid-Connected Turbine Reference Systems; Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

For individuals, businesses, and communities focused on building resilient electrical grid infrastructure, wind energy can provide an affordable, accessible, and compatible distributed energy resource option that also enhances the capabilities of local grid operations. The Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) project is a multi-year distributed wind research effort, driven through a partnership between four Department of Energy National Laboratories and industry to develop and improve the planning, design, and operation of wind-centered microgrids to complement solar, energy storage, and other distributed energy resources for grid-tied and isolated operation (U.S. Department of Energy, 2021). This report documents the application of methods developed through the initial three years of the MIRACL project to two real-world distributed wind reference systems. Specifically, the methods demonstrated in this report include 1) a market valuation framework to comprehensively value the services distributed wind can provide and 2) a resilience framework that enables stakeholders to characterize distribution system resilience and compare grid investment decisions from a resilience perspective. Additional methods mentioned in this report include distributed hybrid system design methods for grid resilience, advanced control co-simulation platforms, and power hardware-in-the-loop (PHIL) models. Preliminary results from these additional methods are presented in this report and will be demonstrated and/or applied to the reference systems in the coming year. The purpose of applying these methods to reference systems is to drive technology transfer of the theories, methodologies, and technologies developed under the MIRACL project and increase the number of referenceable case studies available to stakeholders interested in additional value-added capabilities of wind systems beyond bulk energy supply (i.e. kilowatt-hours).

17 WIND ENERGY↗

Black start demonstrations of small hydropower plants with energy storage

The U.S. has at least 500 municipal, electric co-operative, and publicly owned utilities with hydropower plants. These are mostly grid-connected to support the national grid. However, due to small size (at most 10 MW) and low ramping capacity, many of these hydropower plants lack the capability to form local grids to provide backup power to critical loads (during grid outage) and rural areas. Energy storage, such as Li-Ion batteries or ultracapacitors, can be used to enable these capabilities. Because this technology is relatively new, proof-of-concept demonstrations are needed to de-risk the approach before it can be deployed at scale. Two field demonstrations have been performed to validate this approach, namely, a 375 kVA / 1.24 kWh ultracapacitor with Idaho Falls Power’s 3.6 MW Old Lower (OL), 8.9 MW Lower Bulb (LB), and 8.9 MW City Bulb (CB) hydropower plants; and a 250 kVA / 320 kWh Li-Ion battery with Fall River Electric Cooperative’s 5.5 MW Felt hydropower plant. The Idaho Falls Power demonstration showed the resilience benefits of hybridization, and the Fall River Electric demonstration showed what the minimal requirements are to retrofit a hydropower plant for black start. These demonstrations are funded by the U.S. Department of Energy Water Power Technologies Office HydroWIRES Initiative.

13 HYDRO ENERGY↗

Electrical switching of a p-wave magnet

Magnetic states with zero magnetization but non-relativistic spin splitting are outstanding candidates for the next generation of spintronic devices. Their electronvolt (eV)-scale spin splitting, ultrafast spin dynamics and nearly vanishing stray fields make them particularly promising for several applications. A variety of such magnetic states with non-trivial spin textures have been identified recently, including even-parity d-wave, g-wave or i-wave altermagnets and odd-parity p-wave magnets. Achieving voltage-based control of the non-uniform spin polarization of these magnetic states is of great interest for realizing energy-efficient and compact devices for information storage and processing. Spin-spiral type II multiferroics are optimal candidates for such voltage-based control, as they exhibit an inversion-symmetry-breaking magnetic order that directly induces ferroelectric polarization, allowing for symmetry-protected cross-control between spin chirality and polar order. Here we combine photocurrent measurements, first-principles calculations and group-theory analysis to provide direct evidence that the spin polarization of the spin-spiral type II multiferroic NiI 2 exhibits odd-parity character connected to the spiral chirality. The symmetry-protected coupling between chirality and polar order enables electrical control of a primarily non-relativistic spin polarization. Our findings represent an observation of p-wave magnetism in a spin-spiral type II multiferroic, which may lead to the development of voltage-based switching of non-relativistic spin polarization in compensated magnets.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Motivation and Design of the OCPP Security Service

Pacific Northwest National Laboratory is conducting in-depth research aimed at exploring how zero trust security principles can be effectively applied to electric vehicle charging infrastructure. This investigation seeks to enhance the resilience and reliability of these systems against cyber threats, ensuring secure and uninterrupted access to charging services for electric vehicle users and electric supply. Zero trust is a security concept centered on the belief that system operators should not automatically trust users or systems based on their location, whether inside or outside the organization, but instead must verify everything trying to connect to their systems before granting access. A key aspect of the project is to demonstrate and validate zero trust approaches targeted to electric vehicle (EV) charging infrastructure. It has been observed that both open-source and commercial solutions often overlook the specific protocols employed in managing EV charging stations and proceeded with a general, protocol-agnostic approach. While these strategies effectively block non-authorized routes to the charging infrastructure, they do not tackle the situations where attackers may exploit legitimate access channels, such as the inattentive operator model posited by the Idaho National Laboratory. To address this gap, this paper proposes and discusses a new security service targeted to the Open Charge Point Protocol (OCPP), which is the de facto protocol for the management of charging stations and serves a critical role in the broader adoption of electric vehicles. The design and architecture of the proposed OCPP security service are discussed in detail, outlining how it aims to safeguard charging station management system (CSMS) functions. The service is particularly important in scenarios where the charging station operator (CSO), responsible for the maintenance and operation of charging stations, and the charging network provider (CNP), which manages the charging network's accessibility and billing, are separate entities. This distinction is crucial because CSOs and CNPs often have different priorities, objectives, and operational responsibilities, which may not always align perfectly. For instance, a CSO might prioritize uptime and customer satisfaction, while a CNP might focus on maximizing revenue and network utilization. Such misalignment can create security vulnerabilities, as each entity might implement different policies and standards, potentially leaving gaps in the overall security posture.

33 ADVANCED PROPULSION SYSTEMS↗

Real time trajectory optimization for hybrid energy management utilizing connected information technologies

The disclosure is directed to solving a full trajectory optimization problem in real-time for a hybrid electric vehicle (HEV) such that future driving conditions and energy usage may be fully considered in determining optimal engine energy usage and battery energy usage in real-time during a trip. An electronic control unit of the HEV may be configured to: receive route information for a route to be driven by the HEV; and after receiving the route information, iterating the operations of: measuring a current state of charge (SOC) of the battery; using at least the measured SOC and an initial co-state value stored in a memory, performing a process to iteratively update the co-state value to obtain an updated co-state value; using at least the updated co-state value, computing an updated control value; and applying the updated control value to control a usage of the battery and the internal combustion engine.

Huang, Mike X.↗

Ion Transport in Charged Membranes: Linking Electric-Field-Driven Mechanisms to Pore Size via Perturbation Analysis

Ion-exchange membranes are a critical component in electrochemical systems. Nevertheless, the understanding and modeling of ion transport within these porous structures have been limited by particular complexity reductions, either ignoring the dimensionality of their porous network architecture or imposing geometric assumptions (i.e., overlapping double layers). Before addressing this morphology-transport gap, a framework that relates the driving forces of transport to the geometry of a single pore is required. In this work, our modeling domain consists of a two-dimensional single pore with charged walls, connecting two identical electrolyte reservoirs. Using the Poisson-Nernst-Planck equations and regular perturbation theory, we decouple the electric fields and analyze the driving forces of ion transport, specifically electromigration and induced electroosmosis within the pore. These processes are described as analytical functions of the interaction aspect ratio, ?, defined as the ratio of the pore radius to the Debye length. Using this parameter, our study (i) describes the interplay between electromigrative and electroosmotic mechanisms that set ionic conductivity, (ii) identifies a dimensionless group of intrinsic electrolyte properties that indicates the predominant driving force, and (iii) provides a qualitative, confinement-dependent perspective on selectivity in ion-conducting membranes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transport Cost for Carbon Removal Projects With Biomass and CO2 Storage

Strategies to remove carbon from the atmosphere are needed to meet global climate goals. Promising strategies include the conversion of waste biomass to hydrogen, methane, liquid fuels, or electricity coupled with CO 2 capture and storage (CCS). A key challenge for these projects is the need to connect geographically dispersed biomass supplies with geologic storage sites by either transporting biomass or CO 2 . We assess the cost of transport for biomass conversion projects with CCS using publicly available cost data for trucking, rail, and CO 2 pipelines in the United States. We find that for large projects (order of 1 Mt/yr CO 2 or greater), CO 2 by pipeline is the lowest cost option. However, for projects that send most of the biomass carbon to storage, such as gasification to hydrogen or electricity production, biomass by rail is a competitive option. For smaller projects and lower fractions of carbon sent to storage, such as for pyrolysis to liquid fuels, CO 2 by rail is the lowest cost option. Assessing three plausible example projects in the United States, we estimate that total transport costs range from $24/t-CO 2 stored for a gasification to hydrogen project traversing 670 km to $\$ 36$/t for a gasification to renewable natural gas project traversing 530 km. In general, if developers have flexibility in choosing transport mode and project type, biomass sources and storage sites can be connected across hundreds of kilometers for transport costs in the range of $20-40/t-CO 2 stored. Truck and rail are often viable modes when pipelines cannot be constructed. Distances of 1,000 km or more can be connected in the same cost range when shared CO 2 pipelines are employed.

09 BIOMASS FUELS↗

Operation of Grid Forming Converters as Self Excited Induction Generators Under Non-Ideal Loading Conditions

Self-excited induction generators offer a robust solution for power production for standalone as well as grid-connected systems. In general, self-excited induction generators require excitation capacitors which make use of the machine magnetization characteristics for voltage build up process as well as operation at a specific frequency. In this paper, a self-excited induction machine is modeled with both the electrical and mechanical dynamics. This modeled virtual machine's dynamics are utilized for voltage build up process for a standalone photovoltaic converter connected to a local load for a microgrid application. The modeled machine's parameters are used from the name plate rating from the manufacturer. However, in a microgrid the accommodation of unbalanced and/or nonlinear harmonic rich load is a necessity, therefore, in this work the virtual self-excitation capacitors of the modeled machine are varied based on the machine characteristics. With the objective of ensuring harmonic free point of common coupling voltage, the modeled virtual self-excitation capacitors are varied to accomplish change in terminal frequency and the virtual load torque is varied to obtain voltage magnitude change. To verify the efficacy, the overall system is modeled in MATLAB/Simulink and PLECS domain and most important case studies are presented.

grid forming converters (GFM)↗

Scaling and statistics of bottom-up synthesized armchair graphene nanoribbon transistors

Bottom-up assembled nanomaterials and nanostructures allow for the studies of rich and unprecedented quantum-related and mesoscopic transport phenomena. However, it can be difficult to quantify the correlations between the geometrical or structural parameters obtained from advanced microscopy and measured electrical characteristics when they are made into macroscopic devices. Here, we propose a strategy to connect the nanomaterial morphologies and the device performance through a Monte Carlo device model and apply it to understand the scaling trends of bottom-up synthesized armchair graphene nanoribbon (GNR) transistors. A new nanofabrication process is developed for GNR transistors with channel length down to 7 nm. Further, the impacts of the GNR spatial distributions and the device geometries on the device performance are investigated systematically through comparison of experimental data with the model. Through this study, challenges and opportunities of transistor technologies based on bottom-up synthesized GNRs are pinpointed, paving the way to the further improvement of the GNR device performance for future transistor technology nodes.

36 MATERIALS SCIENCE↗

Differential electron yield imaging with STXM

In this report total electron yield (TEY) imaging is an established scanning transmission X-ray microscopy (STXM) technique that gives varying contrast based on a sample's geometry, elemental composition, and electrical conductivity. However, the TEY-STXM signal is determined solely by the electrons that the beam ejects from the sample. A related technique, X-ray beam-induced current (XBIC) imaging, is sensitive to electrons and holes independently, but requires electric fields in the sample. Here we report that multi-electrode devices can be wired to produce differential electron yield (DEY) contrast, which is also independently sensitive to electrons and holes, but does not require an electric field. Depending on whether the region illuminated by the focused STXM beam is better connected to one electrode or another, the DEY-TXM contrast changes sign. DEY-STXM images thus provide a vivid map of a device's connectivity landscape, which can be key to understanding device function and failure. To demonstrate an application in the area of failure analysis, we image a 100 nm, lithographically-defined aluminum nanowire that has failed after being stressed with a large current density.

47 OTHER INSTRUMENTATION↗

Physics-based compact modeling of electro-thermal memristors: Negative differential resistance, local activity, and non-local dynamical bifurcations

Leon Chua's Local Activity theory quantitatively relates the compact model of an isolated nonlinear circuit element, such as a memristor, to its potential for desired dynamical behaviors when externally coupled to passive elements in a circuit. However, the theory's use has often been limited to potentially unphysical toy models and analyses of small-signal linear circuits containing pseudo-elements (resistors, capacitors, and inductors), which provide little insight into required physical, material, and device properties. Furthermore, the Local Activity concept relies on a local analysis and must be complemented by examining dynamical behavior far away from the steady-states of a circuit. In this work, we review and study a class of generic and extended one-dimensional electro-thermal memristors (i.e., temperature is the sole state variable), re-framing the analysis in terms of physically motivated definitions and visualizations to derive intuitive compact models and simulate their dynamical behavior in terms of experimentally measurable properties, such as electrical and thermal conductance and capacitance and their derivatives with respect to voltage and temperature. Within this unified framework, we connect steady-state phenomena, such as negative differential resistance, and dynamical behaviors, such as instability, oscillations, and bifurcations, through a set of dimensionless nonlinearity parameters. In particular, we reveal that the reactance associated with electro-thermal memristors is the result of a phase shift between oscillating current and voltage induced by the dynamical delay and coupling between the electrical and thermal variables. We thus, demonstrate both the utility and limitations of local analyses to understand non-local dynamical behavior. Critically for future experimentation, the analyses show that external coupling of a memristor to impedances within modern sourcing and measurement instruments can dominate the response of the total circuit, making it impossible to characterize the response of an uncoupled circuit element for which a compact model is desired. However, these effects can be minimized by proper understanding of the Local Activity theory to design and utilize purpose-built instruments.

Brown, Timothy D. (ORCID:0000000347068355)↗

Stability Analysis of Parallel Connected Bidirectional WPT System

This paper presents a stability analysis of parallel-connected bi-directional series-series resonant network wireless power transfer (WPT), optimized for Electric Vehicle (EV) charging and vehicle-to-grid (V2G) applications. The study addresses critical stability challenges in systems integrated with diverse distributed energy resources (DERs), including photovoltaics, fuel cells, wind turbines, energy storage systems, and the AC grid. The stability of such integrated DC grid systems is paramount for ensuring reliable operation, particularly under varying power flow conditions and dynamic interactions between parallel WPT systems. The analysis included system impedance characterization, state-space modeling, and open and closed-loop stability evaluations. The results demonstrated that the integration of a robust control architecture effectively mitigates instability risks and supports scalable, efficient operation. This work underscores the converter's adaptability and its potential for large-scale deployment in wireless EV charging infrastructures and integrated DC grid systems.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Secure and Privacy Aware Data Sharing Approach for Smart Electric Vehicles

The integration of smart electric vehicles (SEVs) into smart cities marks a significant step toward creating efficient, sustainable, and connected urban spaces. However, secure and private data sharing is a major challenge as SEVs connect with smart city systems. The interaction between SEVs and consumer electronic devices (CEDs) raises serious concerns about data security and privacy. Here, to address these challenges, this article presents how blockchain technology and federated learning (FL) can address these issues. The proposed approach provides a secure and privacy-aware framework for data exchange between SEVs and CEDs in smart cities. The experiment results demonstrate the effectiveness of the proposed framework for secure data sharing and maintaining system reliability in smart city environments. It also enables trust and promotes the widespread adoption of interconnected urban technologies.

Das, Debashis [Meharry Medical College, Nashville,↗

Sensitivity Analysis of a Polyphase Wireless Power Transfer System under Off-Nominal Conditions

Misaligned and/or variable coil airgaps cause coupling coefficient variation in wireless power transfer (WPT) systems, resulting in a decrease in the system’s transmitted power and efficiency. This paper presents sensitivity analyses of a three-phase, Y-Y connected, series-tuned WPT system in the frequency domain in terms of several different electric vehicle wireless charging off-nominal conditions (misalignments in Δ x and Δ y directions, change of airgap Δ z , and the roll Δψ, pitch Δθ, and yaw ΔΦ angles) as specified in Society of Automotive Engineers (SAE) J2954 Standard. Coil inductance matrices were obtained by measuring the self- and mutual inductances of the primary and secondary coil phase windings at variable airgap classes (from 5 cm to 30 cm) for five different charging positions as identified in SAE J2954. These 6 × 6 inductance matrices were used in sensitivity and Plexim/PLECS simulation analyses. The sensitivity of the WPT system was analyzed analytically using the input impedance and phase angle, voltage gain, current gain, quality factor, and coupling coefficient parameters of the series-tuned WPT system. The results were confirmed experimentally on a 50 kW WPT system.

42 ENGINEERING↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating a Microgrid Controller with a Local OpenADR Server

When military microgrids isolate themselves from the main electrical grid, they must locally balance electricity supply and demand. Since local generation may be limited, the current strategy is to shed all but the most critical loads by tripping smart circuit breakers, which must then be reset manually (e.g., ESTCP project EW-201350). This strategy is typically applied at the building level, meaning that entire buildings housing mission critical activities must be excluded from any load management, while those considered non-critical may lose service entirely. The remotely controlled switchgear needed to manage load in this way is very expensive ($\$30,000$-$\$50,000$ per building). While effective at shedding load, this strategy disrupts installation operation and risks damaging equipment during both disconnection and re-energization. With the goals of lowering costs, protecting equipment, and enhancing the agility of DoD microgrids, this report demonstrates the use of cybersecure automated demand response (ADR) technology to manage microgrid loads during grid-independent (a.k.a. "islanded") operation. This automated approach achieves load shedding and shifting through communication signals sent to equipment controllers rather than by cutting off the flow of electricity within the microgrid itself. Because it operates only on the base network, with no connection to external entities, this strategy avoids the main cybersecurity concern raised by past applications of ADR on military bases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and Verification of An Open-Circuit Electro-Hydraulic Actuator System with An Integrated Electro-Hydraulic Unit

This paper proposes an electro-hydraulic actuator (EHA) system, and two novel-designed electro-hydraulic units (EHU) consisting of a fixed-displacement hydraulic pump and a variable-speed electric motor. Both the novel EHU designs integrate an electric machine and a hydraulic machine in a single unit, featuring compactness and power density. However, they differ for salient aspects such as power and electric machine cooling system. The EHA system features an open circuit design, where hydraulic hoses connect the EHU with a tank, a valve manifold, and the hydraulic cylinder. In this way, the proposed EHA technology can be used to implement distributed hydraulic actuation in a vehicle without requiring changes to the hydraulic actuators or at the overall layout of the hydraulic components with respect to the original vehicle design. A dedicated test rig is developed to verify the performance of the proposed EHA system. The efficiency of the EHA is measured in a steady state and under a realistic duty cycle of a commercial compact loader. The measured efficiency of the system can reach 54% with up to 20kN load and 6kW power level.

42 ENGINEERING↗