Search NASA⌕ Search

SEARCH · Search NASA

Results for “filled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Gel-Filled Holders For Ultrasonic Transducers

In new technique, ultrasonic transducer embedded in rubbery, castable, low-loss gel to enable transducer to "look" into surface of test object or human body at any desired angle. Composed of solution of water and ethylene glycol in collagen matrix. Provides total contact of water bath, also used on bodies or objects too large for water baths, even if moving. Also provides look angles of poly(methyl methacrylate) angle block with potential of reduced acoustic impedance and refraction. Custom-tailored to task at hand, and gel sufficiently inexpensive to be discarded upon completion. Easy to couple ultrasound in and out of gel, minimizing losses and artifacts of other types of standoffs employed in ultrasonic testing.

Companion, John A.↗

Solute-Filled Syringe For Formulating Intravenous Solution

Prefilled syringe contains premeasured amount of solute in powder or concentrate form used to deliver solute to sterile interior of large-volume parenteral (LVP) bag. Predetermined amount of sterile water also added to LVP bag through sterilizing filter, and mixed with contents of syringe, yielding sterile intravenous solution of specified concentration.

Owens, Jim↗

Nature of fluid flows in differentially heated cylindrical container filled with a stratified solution

Semiconductor crystals such as Hg(1-x)Cd(x)Te grown by unidirectional solidification Bridgmann method have shown compositional segregations in both the axial and radial directions. Due to the wide separation between the liquidus and the solidus of its pseudobinary phase diagram, there is a diffusion layer of higher HgTe content built up in the melt near the melt-solid interface which gives a solute concentration gradient in the axial direction. Because of the higher thermal conductivity in the melt than that in the crystal there is a thermal leakage through the fused silica crucible wall near the melt-solid interface. This gives a thermal gradient in the radial direction. Hart (1971), Thorpe, Hutt and Soulsby (1969) have shown that under such condition a fluid will become convectively unstable as a result of different diffusivities of temperature and solute. It is quite important to understand the effects of this thermosolute convection on the compositional segregation in the unidirectionally solidified crystals. To reach this goal, we start with a simplified problem. We study the nature of fluid flows of a stratified solution in a cylindrical container with a radial temperature gradient. The cylindrical container wall is considered to be maintained at a higher temperature than that at the center of the solution and the solution in the lower gravitational direction has higher solute concentration which decrease linearly to a lower concentration and then remain constant to the top of the solution. The sample solution is taken to be salt water.

Wang, Jai-Ching↗

Weld-Fill Program

ROCKFILL is software that calculates key robot weld information. Its easy-to-use menu system enables robot operator to estimate better number of passes, amount of wire, arc time, and amount of heat put into particular weld. Designed to operate on work-cell personal computer of robot and requires no documentation or training. Written in C language.

Maslakowski, John E.↗

Metal-Filled Adhesives Amenable To X-Ray Inspection

Adhesive joints between metal parts made amenable to nondestructive radiographic inspection by incorporating radiopaque fillers that increase x-ray contrasts of joints. Adhesives can be epoxies, urethanes, acrylics, phenolics, or silicones, with appropriate curing agents and with such modifiers as polysulfides, polyamides, or butadiene rubbers.

Hermansen, Ralph D.↗

Circulatory filling pressures during transient microgravity induced by parabolic flight

Theoretical concepts hold that blood in the gravity dependent portion of the body would relocate to more cephalad compartments under microgravity. The result is an increase in blood volume in the thoraic and cardiac chambers. However, experimental data has been somewhat contradictory and nonconclusive. Early studies of peripheral venous pressure and estimates of central venous pressure (CVP) from these data did not show an increase in CVP under microgravity. However, CVP recorded in human volunteers during a parabolic flight revealed an increase in CVP during the microgravity state. On the STS 40 shuttle mission, a payload specialist wore a fluid line that recorded CVP during the first few hours of orbital insertion. These data revealed decreased CVP. When this CVP catheter was tested during parabolic flight in four subjects, two had increased CVP recordings and two had decreased CVP measurements. In 1991, our laboratory performed parabolic flight studies in several chronic-instrumented baboons. It was again noted that centrally recorded right atrial pressure varied with exposure to microgravity, some animals having an increase, and others a decrease.

Latham, Ricky D.↗

Improved Net-Level Filling And Finishing Of Large Castings

Improved method of vacuum casting of large, generally cylindrical objects to net sizes and shapes reduces amount of direct manual labor by workers in proximity to cast material. Original application for which method devised is fabrication of solid rocket-motor segments containing solid propellant, wherein need to minimize exposure of workers to propellant material being cast. Improved method adaptable to other applications involving large castings of toxic, flammable, or otherwise hazardous materials.

Johnson, Erik P.↗

Substances To Fill Lighter-Than-Air Balloons

Various combinations of solid and liquid chemicals proposed as sources of hydrogen and other gases for inflating lighter-than-air balloons. In all cases energy used to propel balloon upward or downward comes from temperature differences in planet's atmosphere itself. Phase changes and/or reversible chemical reactions used to vary quantities of gases in balloons as functions of pressure and temperature and, as functions of altitude: provides means to control altitude of balloon.

Jones, Jack A.↗

A Study of Supernova Remnants with Center-Filled X-Ray Morphology

The proposed study entails use of archival data, primarily from past and active X-ray observatories, to study the properties of a class of supernova remnants (SNRs) which display a centrally-bright X-ray morphology. Several models which have been proposed to explain the morphology are being investigated for comparisons with measured characteristics of several remnants: nonthermal emission from a central synchrotron nebula; thermal emission enhanced by slow evaporation of cool clouds in the hot SNR interior; and relic thermal emission from the SNR interior after the remnant has entered the radiative phase of evolution, thus causing the shell emission to cease.

Slane, Patrick O.↗

Attenuation of Weather Radar Signals Due to Wetting of the Radome by Rainwater or Incomplete Filling of the Beam Volume

A search of scientific literature, both printed and electronic, was undertaken to provide quantitative estimates of attenuation effects of rainfall on weather radar radomes. The emphasis was on C-band (5 cm) and S-Band (10 cm) wavelengths. An empirical model was developed to estimate two-way wet radome losses as a function of frequency and rainfall rate for both standard and hydrophobic radomes. The model fits most of the published data within +/- 1 dB at both target wavelengths for rain rates from less than ten to more than 200 mm/hr. Rainfall attenuation effects remain under 1 dB at both frequencies regardless of radome type for rainfall rates up to 10 mm/hr. S-Band losses with a hydrophobic radome such as that on the WSR-88D remain under 1 dB up to 100 mm/hr. C-Band losses on standard radomes such as that on the Patrick AFB (Air Force Base) WSR-74C can reach as much as 5 dB at 50 mm/hr. In addition, calculations were performed to determine the reduction in effective reflectivity, Z, when a radar target is smaller than the sampling volume of the radar. Results are presented for both the Patrick Air Force Base WSR-74C and the WSR-88D as a function of target size and range.

Merceret, Francis J.↗

When Earth Songs Filled the Void of Space

Before the late 50's we had the planets, our Sun, the stars, galaxies, spectacular clouds of dust and very little else in our universe. There was evidence for a highly tenuous "sea" of dust in interstellar space, but little else. Space was empty above the ionized gases of our upper atmosphere, a little like there was no color in the world before the 40's. The clues were there to think otherwise, however, and in the late 50's and early 60's a few researchers dared to challenge the conventional ideas about space. It was a time of discovery and, with our new ability to fly in space, a time that launched a new science. Today that science makes it possible to literally see some of the plasmas that populate near-Earth space, which are now known to exist everywhere.

Gallagher, Dennis L.↗

When Earth Songs Filled the Void of Space

What we think about space changed dramatically during the 1950's and early 60's. This story, like perhaps most stones about big changes in how scientists think about nature, involves tribulation, risk talung, and a renewal of the scientific method. What do you think about space, that unimaginably large region between planets and stars? Some of the people, their ideas, and how science often works will be discussed during this presentation.

Gallagher, D. L.↗

Gravitational Effects of Flooding and Filling of Impact Basins on Mars

The presence of large impact basins and the low northern plains that might have contained ice or liquid water at an earlier stage of Mars evolution suggests that the global gravity field could have been different in the distant past than it is today. In addition, any significant change in the distribution of mass affects the moments of inertia and consequently and could conceivably change the position of the pole and the length of day. Similar effects could have been produced by large erosional processes, such as the removal of crustal material from the Arabia Terra region and subsequent re-deposition in the Chryse region of the northern plains. We have endeavored to estimate the magnitudes of material that might have been involved in these processes and their possible effect on the gravity and dynamics of Mars. We have used present-day topography and gravity field as a starting point, recognizing that both the result of the processes that we are trying to study rather than the state at the times of interest.

Smith, David E.↗

Ventricular filling slows epicardial conduction and increases action potential duration in an optical mapping study of the isolated rabbit heart

INTRODUCTION: Mechanical stimulation can induce electrophysiologic changes in cardiac myocytes, but how mechanoelectric feedback in the intact heart affects action potential propagation remains unclear. METHODS AND RESULTS: Changes in action potential propagation and repolarization with increased left ventricular end-diastolic pressure from 0 to 30 mmHg were investigated using optical mapping in isolated perfused rabbit hearts. With respect to 0 mmHg, epicardial strain at 30 mmHg in the anterior left ventricle averaged 0.040 +/- 0.004 in the muscle fiber direction and 0.032 +/- 0.006 in the cross-fiber direction. An increase in ventricular loading increased average epicardial activation time by 25%+/- 3% (P < 0.0001) and correspondingly decreased average apparent surface conduction velocity by 16%+/- 7% (P = 0.007). Ventricular loading did not significantly alter action potential duration at 20% repolarization (APD20) but did at 80% repolarization (APD80), from 179 +/- 7 msec to 207 +/- 5 msec (P < 0.0001). The dispersion of APD20 was decreased with loading from 19 +/- 2 msec to 13 +/- 2 msec (P = 0.024), whereas the dispersion of APD80 was not significantly changed. These electrophysiologic changes with ventricular loading were not affected by the nonspecific stretch-activated channel blocker streptomycin (200 microM) and were not attributable to changes in myocardial perfusion or the presence of an electromechanical decoupling agent (butanedione monoxime) during optical mapping. CONCLUSION: Acute loading of the left ventricle of the isolated rabbit heart decreased apparent epicardial conduction velocity and increased action potential duration by a load-dependent mechanism that may not involve stretch-activated channels.

NASA Program Biomedical Research and Countermeasur↗

Chronic mitral regurgitation and Doppler estimation of left ventricular filling pressures in patients with heart failure

Previous studies relating Doppler parameters and pulmonary capillary wedge pressures (PCWP) typically exclude patients with severe mitral regurgitation (MR). We evaluated the effects of varying degrees of chronic MR on the Doppler estimation of PCWP. PCWP and mitral Doppler profiles were obtained in 88 patients (mean age 55 +/- 8 years) with severe left ventricular (LV) dysfunction (mean ejection fraction 23% +/- 5%). Patients were classified by severity of MR. Patients with severe MR had greater left atrial areas, LV end-diastolic volumes, and mean PCWPs and lower ejection fractions (each P <.01). In patients with mild MR, multiple echocardiographic parameters correlated with PCWP; however, with worsening MR, only deceleration time strongly related to PCWP. From stepwise multivariate analysis, deceleration time was the best independent predictor of PCWP overall, and it was the only predictor in patients with moderate or severe MR. Doppler-derived early mitral deceleration time reliably predicts PCWP in patients with severe LV dysfunction irrespective of degree of MR.

NASA Discipline Cardiopulmonary↗